Radio Frequency Energy, Certifications, Recycling Information
CE Certification
This equipment complies with the requirements relating to electromagnetic compatibility, EN
55024 and EN55022 for ITE (Information Technolology Eqipment), EN61000-3-2/-3.
FCC Warning
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired
WEEE (Waste of Electrical and Electronic Equipment),
Recycling of Electronic Products
All EU countries
In 2006 the European Union introduced regulations (WEEE) for the collection and recycling of
all waste electrical and electronic equipment. It is no longer allowable to simply throw away
electrical and electronic equipment. Instead, these products must enter the recycling process.
Each individual EU member state has implemented the WEEE regulations into national law in
slightly different ways. Please follow your national law when you want to dispose of any
electrical or electronic products. More details can be obtained from your national WEEE
recycling agency.
LINDY No. 39399
1st Edition, January 2011
www.lindy.com
Fiber Optic DVI-D KVM Extender
User Manual English
MAX OUTPUT: 10mW
MULTI WAVE LENGTH: 1310/1550nm
This product contains invisible and/or visible laser beams. Under normal operation this
radiation is not harmful to eyes and skin. Avoid eye and skin exposure.
Under normal operation the laser transmitters should switch of when no fibre cable is connected
or when the cable is broken. If you experience any problems with this product please contact
LINDY. Under no circumstances must the product housing be opened.
LINDY No. 39399
www.lindy.com
WARNING!
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (JAN 2011)
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (JAN 2011)

User Manual English
Introduction
Thank you for purchasing the LINDY Fibre Optic DVI-D KVM Extender. This fibre optic extender
allows you to transmit up to DVI-D Single Link @ 1920x1200 or 1080p (without HDCP) and
USB mouse and keyboard signals up to a distance of 1000m/3000feet using standard
multimode 50/125µm SC Duplex fibre cable. In addition to extending DVI-D, keyboard and
mouse signals, the extender can also repeat IR remote commands/signals, with the use of the
optional IR Repeater Kit (LINDY No. 38006).
For larger distances of up to 5 kilometres please contact LINDY website or support team for
information about a single mode version.
Features & Specifications
Extends DVI-D and USB mouse & keyboard signals up to 1000m/3000feet
Compatible with USB and multi-protocol mice and keyboards at the receiver/user console.
Does not support USB HID functions for touch screens or similar.
Compatible with USB or PS/2 mouse and keyboard ports at the transmitter / PC
Uses standard inexpensive 50/125µm SC Duplex Multimode Fibre Cable
Total Bandwidth 6Gbit/s. over a single 2-core Fibre Optic Cable
Auto power save mode when source device is powered off
Auto Laser disable if fibre cable is broken or removed
Optional IR repeater function (order IR Repeater Kit separately, LINDY No. 38006)
Compatible with DVI 2.0 specification, supports DVI-D Single Link
Supports resolutions up to 1920x1200@60Hz or 1080p without HDCP
Supports connection of HDMI equipment using DVI-HDMI cables – however, HDCP is not
supported.
Uses EDID emulation for DVI-D video resolution setting
Maximum DVI-D and USB cable length up to 5m in and out
Dimensions: 16.5cm x 11cm x 3.5cm (WxDxH), each unit
Multi country wall mount power supply 100 - 240VAC / 5V DC ~2A
Package Contents
LINDY Fibre Optic DVI-D KVM Extender x 2 (1x Transmitter, 1x Receiver)
Multi-Country Power Adapter (5V DC) x 2
1x DVI-D cable, 2x PS/2 cable, 1x USB A/Mini-B cable – all 2m
This User Manual
User Manual English
Installation
1. Connect your DVI-D source to the Fibre Optic Transmitter (maximum cable length 5m).
2. For mouse and keyboard signals connect either the two PS/2 cables or the USB A/Mini-B
cable from the Fibre Optic Transmitter to your computer. The transmitter supports PS/2 as
well as USB connection for mouse and keyboard PC connection.
3. Remove the dust covers from the Fibre Optic Transmitter and Receiver ports and from your
SC Fibre Cable (maximum length 1000m). Connect one end of the SC duplex fibre cable to
the Transmitter and the other end to the Receiver. This must be set up as A to A and B to
B connection (see port labelling on the units) and NOT as a cross over connection as
provided by some SC Duplex Cables with pre-installed clamp on the connector. If you
have a cross over cable please swap the connectors over with each other on one end only.
Please ensure that the SC connectors are fully engaged before proceeding.
4. Use another DVI-D cable (maximum length 5m) to connect your DVI-D display device to the
DVI-D port on the Receiver.
5. Connect your USB (or multi protocol USB-PS/2) mouse and keyboard to the USB ports on
the receiver labelled with mouse and keyboard symbols.
6. If you are using the optional IR extender kit (LINDY No. 38006) please connect the IR
receiver to the receiver unit and the IR transmitter to the transmitter unit and place the IR
receiver and transmitter in appropriate position.
7. Plug the power supplies into the transmitter and receiver and power on.
8. Then power on your display and source to complete the installation
Please Note: The extender uses EDID emulation for the video signal resolution setting. The
highest supported resolution is 1920x1200@60Hz. If your monitor is only able to support
lower resolutions it may be necessary to set the video resolution on your signal source
(computer) before installing the extender.
Troubleshooting
If you have no image on your display
Check that the DC plugs and jacks used by external power supplies (both the extender units
and others) are firmly connected and that the Power LED is on.
Check that the SC fibre connectors are plugged in correctly and that the Link Status LED is
lit. If the Link LED is not lit then check your cable has a A:A and B:B configuration. If it still is
not lit, please try another SC cable to make sure it isn't broken.
Check that the DVI-D source and display are both powered on and active. Please note that
HDCP is not supported.
If Power and Link LEDs are on, reduce the length of DVI-D, USB and PS/2 cables.
If you cannot solve the problem please contact the LINDY Support team – you can find our
worldwide contact information always up to date on our website.