TO AVOID ELECTRICAL SHOCK THAT CAN CAUSE SEVERE INJURY OR DEATH, ALWAYS UNPLUG
LIQUIDIZER / MIXER BEFORE PROCEEDING WITH ALL MAINTENANCE OR CLEANING PROCEDURES!
IN ORDER TO AVOID DAMAGE TO PEOPLE AND THE APPLIANCE, READ AND FOLLOW THE
MANUFACTURER’S INSTRUCTIONS FOR THE CLEANING OF THE LIQUIDIZER / MIXER.
LIMITED ONE (1) YEAR WARRANTY
Lincoln Foodservice Products, LLC (“Lincoln”) warrants, to the original purchaser for use in the United States of
America, that each new item of Redco Insta Blend, Insta Prep or Insta Juice manufactured by it (“Warranted
Product”) is free of defects in material and workmanship under normal use and conditions.
The exclusive remedy available under this Limited Warranty is that Lincoln will, free of charge, but at its option,
subject to, and in accordance with the terms and conditions of this Limited Warranty, repair or replace, for the
original purchaser for use in the United States of America, any Warranted Products or part thereof that proves to be
defective with the same or a similar item or part, it is returned to Lincoln in accordance with the procedure set out
on the warranty card.
This Limited Warranty applies only to original parts of Warranted Products sold for use in the United States of
America and does not apply to any Warranted Products located outside the United States of America, regardless of
where sold, or to any item or part thereof that has been subjected to accident, casualty, alteration, misuse, or abuse
or if the date of manufacture is altered or removed.
THE OBLIGATION OF LINCOLN IS LIMITED TO THE ABOVE AND, EXCEPT AS EXPRESSLY STATED
HEREIN, LINCOLN MAKES NO GUARANTEES OR WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING,
WITHOUT LIMITATION, WARRANTIES OF FITNESS OR MERCHANTABILITY, WITH RESPECT TO
WARRANTED PRODUCTS. LINCOLN SHALL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES OF ANY KIND, NO ONE IS AUTHORIZED TO MAKE ANY GUARANTEES OR
WARRANTIES, EXPRESSED OR IMPLIED, ON BEHALF OF LINCOLN.
SOME STATES DO NOT ALLOW LIMITATIONS OF IMPLIED WARRANTIES, OR THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTLY DAMAGES IN CONNECTION WITH THE SALE OF
CONSUMER PRODUCTS, CONSEQUENTLY, IF YOU ARE A CONSUMER, AS THAT TERM IS LEGALLY
DEFINED, THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
TABLE OF CONTENTS
Limited Warranty……………………………………………………………………………………………………………….. 2
General Information / Specifications…………………………………………………………………………………………. 3
Operating Instructions………………………………………………………………………………………………………….. 4
Maintenance…………………………………………………………………………………………………………………..… 5
Shock Hazard / Warnings……………………………………………………………………………………………………… 6
Parts Lists with Diagrams……………………………………………………………………………………………………… 8
Schematics……………………………………………………………………………………………………………………. 12
InstaBlend - 16000 Series Ops Manual
2
MODELS
This manual describes the operation and maintenance of the 16900, 16901, 16902, 16903 and 16904 portable
liquidizers, mixers and liquidizer/mixers.
The model reference and its specifications are shown on the identification plate located on the front of the unit.
The InstaBlend has been designed and manufactured in accordance with the following standards:
Standards for machine safety: UL 1097, UL 763, UL 94
Standards for Hygiene and Food equipment materials: ANSI-NSF 8 and ANSI-NSF 51.
For best results and a long service life, follow the instructions given in this manual.
POSITIONING
The InstaBlend is not permanently fixed in one location. It can be carried to the required location/area for use
where there is a suitable wall receptacle. Each unit is supplied with a wall for convenient storage.
InstaBlend - 16000 Series Ops Manual
3
OPERATION
Plug the appliance into a proper electrical outlet.
MODELS 16900, 16901, 16902, 16903
STARTING
Pressing the “Start” button (B) together with the
“Safety” button (D) will cause the machine to
start. The machine will not start if the “Safety”
button is not actuated. Releasing the “Start”
button will cause the machine to stop operating.
CONTINUOUS OPERATION
For continuous operation, while the machine is
running, press the “Lock” button (C). After the
“Lock” button is depressed, the “Start” button
may be released and the machine will continue to
operate. Pressing the “Start” button again will
shut off the machine.
Models 16902 and 16903 – The Speed Control
(A) may be adjusted to change the speed of the
blade or mixer.
MODEL 16904
STARTING
Pressing the “Start” button (1) together with the
“Safety” button (2) will cause the machine to
start. The machine will not start if the “Safety”
button is not actuated. After the machine has
started, the “Safety” button may be released and
the machine will continue to operate. Releasing
the “Start” button will cause the machine to shut
off.
BEST RESULTS
Best results are achieved by introducing the arm of the machine into the bowl, up to 2/3 of the arm’s length.
For optimum operation, it is better if the foot of the machine does not touch the bottom of the bowl.
In order to prevent splashed food from getting inside the motor unit, it is recommended not to incline the appliance
more than 30°.
InstaBlend - 16000 Series Ops Manual
4
MAINTENANCE
TO AVOID ELECTRICAL SHOCK THAT CAN CAUSE SEVERE INJURY OR DEATH, ALWAYS UNPLUG
LIQUIDIZER / MIXER BEFORE PROCEEDING WITH ANY CLEANING OR MAINTENANCE PROCEDURES!
IN ORDER TO AVOID DAMAGE TO PEOPLE AND THE APPLIANCE, READ AND FOLLOW THE
MANUFACTURER’S INSTRUCTIONS FOR THE CLEANING OF THE LIQUIDIZER / MIXER.
DO NOT USE THE FOLLOWING PRODUCTS:
• Abrasive cleaners such as Ammonia, Lye, etc.
• Solvents
• Metal Scourers
• Gritty Detergents
These products would score, scratch and damage the metallic and plastic surfaces of the appliance.
WARNING
!
!
CLEANING PROCEDURE
All parts of the machine that come into contact with the food product should be cleaned immediately after each use.
Place up to 2/3 of the length of the mixer arm into hot water (95° F to 115° F) and switch on for a few seconds. The
mixer and blade must be cleaned with hot water and a mild detergent, leaving the blade with warm water to remove
any residue. Allow the mixer arm and blade to air dry.
The motor set must be cleaned with a damp cloth. Under no circumstances must water enter the motor set. If
water accidentally enters the motor set, dry the motor set carefully before switching on the machine.
After cleaning, place the machine in its wall support.
Models 16900, 16901, 16902, 16903:
The Liquidizer/Mixer arm may be removed for cleaning. To remove the Liquidizer/Mixer arm, turn the
Liquidizer/Mixer clockwise until the arm separates from the motor set. To reassemble, reverse the procedure.