Lincoln Electric K2376-1 User Manual

ENVIRONMENTAL SYSTEMS
60
5
0
H
z
1
PHASE
9
4 CFM
LO:
HI:
135 CFM
Miniflex
Portable Welding Fume Extractor
Lincoln Electric’s Miniflex is a portable, high vacuum, low volume system specifically designed for the removal and filtration of welding fumes. For light duty welding applications, the Miniflex excels in performance, design and ease of handling. It can be completely disassembled in a matter of minutes for cleaning and maintenance. With an automatic start/stop function, the unit automatically turns on and off during welding. And with its standard set of wheels and optional wall-mounting bracket, it can be easily moved around or positioned off the work floor, out of the welder’s working space.
Processes
Stick, TIG, MIG, Flux-Cored
Advantage Lincoln
• Excellent quality product at an affordable price.
• Well thought-out, user-friendly design.
• Five-stage filtration system for higher efficiency.
• LongLife-H™ filter technique separates and retains small particles for maximum efficiency.
• Main filter with spark arrestor surface area: 130 ft2(12 m2).
• Activated carbon filter (Optional) for improved filtration of odors.
• Final filter: HEPA H12 Class.
• Two powerful motors: 1.2 hp each.
• Multiple extraction capacity settings:
— Low: 94 CFM.
— High: 135 CFM.
• Cable sensor allows automatic start/stop capability.
• Low noise level: 70dB(A) with nozzle extraction installed.
• Unlike competitive models, standard wheels and handle make it easy to roll the Miniflex around the shop.
• Weight: 36 lbs. (16 kg).
• One-year warranty on Miniflex unit, 30 day warranty on all
consumables, such as filters, hoses, hose adapters.
Base Unit Includes
• 9 ft.(3 m) cord (AWG 14) with 15 amp plug (NEMA 5-15).
• 8 ft. (2.5 m) length x 1-3/4 in. (45 mm) O.D. extraction hose.
• LongLife-H main filter.
• HEPA filter.
• 2 spare sets of carbon brushes and seals for motors.
Extraction
Capacity
Input
TECHNICAL SPECIFICATIONS
Product Product Input Dimesions Net Weight
Name Number Power Input Current H x W in (mm) lbs (kg)
Miniflex K2376-1 115V/1/50/60 15A 28-3/4 x 16-1/2 36
(730 x 420) (16)
Publication E13.11 1/07
Web Update 5/08
www.lincolnelectric.com
A CLOSER LOOK
Ø 360 mm
420 mm
675 mm
730 mm
Weight and Design
Constructed out of synthetic components, the Miniflex is light­weight, at only 36 lbs. (16 kg), and impact resistant with a user­friendly design. With wheels and handle standard, the Miniflex can be easily rolled or carried around, unlike competitive models.
Five-Stage Filtration Process
The Miniflex has a five-stage filtration process. In stage one, as the air enters the system through an intake connection, it passes through a removable and washable metal pre-filter in which heavier particles and foreign material are captured. In stage two, the air passes through a second metal pre-separator to further reduce any large particle matter from reaching the LongLife-H main filter. In stage three, the air passes through the LongLife-H main filter where the welding fume particles are captured and deposited. In an optional stage four, after flowing through the LongLife-H filter, the air passes through the optional activated carbon filter to help prevent or neutralize the release of odors back into the environment. In the final stage (stage five), the air passes through a HEPA filter (also known as High Efficiency Particle Air).
LongLife-H filter
The unique design of the Miniflex's LongLife-H main filter has resulted in a very large filter surface area equaling 130 ft2(12 m2). With such a large surface area, the filter has an extended life. The LongLife-H filter is designed to dispose of extracted welding fume deposits at the time of filter disposal, preventing deposits from being released during welding.
Automatic Start/Stop for
less energy consumption,
convenience and longer
filter life.
14-1/4 in.
16-1/2 in.
26-1/2 in.
28-3/4 in.
Cable Sensor
At the top of the Miniflex unit is an automatic start/stop button and a manual button. When the Miniflex is being operated in automatic mode, the unit automatically switches on as welder begins to weld, and automatically switches off approximately 15 seconds after welder stops welding. The result is less energy consumption and non-continuous noise. For the automatic start/stop function to work, the welder’s work cable or power cable must be laid across the top of the Miniflex unit in the slotted groove with an integrated sensor.
When the Miniflex is being operated in manual mode, the unit is continuously running.
Reduced Noise
Smart noise insulation around the air exhaust significantly reduces noise without overheating the motors. 70dB(A) with nozzle extraction installed.
Two Parallel Motors
The Miniflex is powered by two 1.2 hp motors allowing for sufficient extraction capacity under all conditions. At the top of the Miniflex unit is a high/low button. In high mode, both motors are working at 100% capacity, extracting 135 CFM of air. In low mode, both motors are working at 50% capacity, extracting 94 CFM of air. With both motors increasing and decreasing speed, the result is a continuously balanced system with reduced maintenance. The motors parallel positioning design reduces noise.
Smart noise
insulator.
Stage 5
HEPA Filter (KP2390-2)
for higher
filtration
efficiency.
Stage 1
Pre-filter captures larger
particles and drops
particulate matter into
collection tray.
Two motors for better performance.
Stage 4
Activated
carbon filter.
(K2389-1 Optional)
Stage 3
LongLife-H Filter
(KP2390-1)
Stage 2
Pre-separator for
capturing medium
to heavy particulate
matter.
Intake Connection for
Extraction Hose.
Wheels standard
for easy portability.