Lincoln Electric IMT10106 User Manual [en, de, es, fr]

®
RETURN TO MAIN MENU
POWER MIG 180 DUAL
IMT10106
October, 2011
For use with machines having Code Numbers:
TABLE OF CONTENTS
Installation . . . . . . . . . . . . . . . . . . .Section A
Technical Specifications . . . . . . . . . . . . . .A-1
Safety Precautions . . . . . . . . . . . . . . . . . .A-1
Location . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Stacking . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Tilting . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Identify and Locate Components
Operation . . . . . . . . . . . . . . . . . . . .Section B
Safety and Product Description . . . . . . . . .B-1
Controls and Settings . . . . . . . . . . . . .B-2, B-3
Drive Roll and Wire Guides Table . . . . . . .B-4
Setting Up and Making a
Flux-Cored Weld . . . . . . . . . . .B-4 thru B-6
Setting Up and Making a MIG Weld and
Install Shielding Gas . . . . . . . .B-7 thru B-10
Setting Up and Making a Aluminum WeldB-11
Accessories . . . . . . . . . . . . . . . . . .Section C
Optional Accessories . . . . . . . . . . . . . . . . .C-1
Utility Carts . . . . . . . . . . . . . . . . . . . .C-2, C-3
Maintenance . . . . . . . . . . . . . . . . .Section D
Safety Precautions . . . . . . . . . . . . . . . . . .D-1
Wire Feed Compartment, Fan Motor, Wire Reel
Maintenance . . . . . . . . . . . . . . . . . . . . . .D-1
Gun And Cable Maintenance . . . . . . . . . .D-1
Overload Protection . . . . . . . . . . . . . . . . . .D-2
Component Replacement Procedures . . .D-2
Troubleshooting . . . . . . . . . . . . . .Section E
Safety Precautions . . . . . . . . . . . . . . . . . .E-1
How to Use Troubleshooting Guide . . . . . .E-1
Troubleshooting Guide . . . . . . . .E-2 thru E-3
Wiring Diagram and Dimension Print Section F
Parts Pages . . . . . . . . . . . . .P-673, P-202-AJ
. . . . . . . . .A-2
11828
ISO 9001
ANSI RAB
QMS
Quality Program Certified byP ABS Quality Evaluations, Inc.P
to ISO 9001 Requirements.
CERTIFICATE NUMBER: 30273
Safety Depends on You
Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READ­ING THIS MANUAL AND THE SAFETY PRECAUTIONS CON­TAINED THROUGHOUT. And,
most importantly, think before you act and be careful.
OPERATORʼS MANUAL
MANUAL DE OPERACIÓN
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
MANUEL DE LʼOPÉRATEUR
Copyright © Lincoln Global Inc.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
i
SAFETY
i
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause can­cer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz­ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.
___________________________________________________
1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND MAGNETIC FIELDS may be dangerous
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
Route the electrode and work cables together - Secure
2.d.1.
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
ii
SAFETY
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases. When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and within applicable OSHA PEL and ACGIH TLV limits using local exhaust or mechanical ventilation. In confined spaces or in some circum­stances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
5. b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the spe­cific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors form phosgene, a highly toxic gas, and other irritating prod­ucts.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
vapors
OPERATORʼS MANUAL
to
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
iii
SAFETY
iii
WELDING and CUTTING SPARKS can cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even been “cleaned”. For information, purchase “Recommended Safe Practices for the Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f. free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate cir­cuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
the welding sparks from starting a fire.
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode if damaged.
7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Refer to http://www.lincolnelectric.com/safety for additional safety information.
NOTES
OPERATORʼS MANUAL
Thank You
iviv
for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip­ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses­sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor­mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customerʼs particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.
CUSTOMER ASSISTANCE POLICY
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
Your Product”. Please complete the form and submit your registration.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
WEB SITE at www.lincolnelectric.com. Choose “Support” and then “Register
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
INSTALLATION
A-1A-1
TECHNICAL SPECIFICATIONS
180 Amp unit (K3018-1)
INPUT – SINGLE PHASE ONLY
Standard Voltage/Frequency Input Current
230 V 60 Hz 208 V 60 Hz 20 Amps @ rated output 120 V 60 Hz
RATED OUTPUT
Voltage/Duty
230 V 30% 130 Amps 20 208 V 30% 130 Amps 17.6 120 V 20% 90 Amps 19.5
Cycle Current Voltage at Rated Amperes
OUTPUT
Welding Current Range Open Circuit Voltage Wire Speed Range
(208V / 230V) 30-180 Amps 34 V 50 - 500 in/min.
(120V) 30-140 Amps 33 V (1.3 - 12.7 m/min.)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Voltage/Frequency Fuse or Breaker Size
230V / 208V 60 Hz 40 Amp 20 Lincoln Electric
120V 60 Hz 20 Amp
2
1
Input Amps Power Cord
20 Lincoln Electric
Part Number:
Part Number:
M22590
M22589
OPERATORʼS MANUAL
PHYSICAL DIMENSIONS
Height Width Depth Weight
14.08 in 10.37 in 18.78 in 66 Ibs
357.6 mm 263.4 mm 477.6 mm 30 kg
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
2
Requirements for maximum output: In order to utilize the maximum output capability of the machine, a branch circuit capable of 30 amps @ 120 volts, 60Hz is required.
Read entire installation section before starting installation.
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Only qualified personnel should perform this installation.
• Only personnel that have read and under­stood the POWER MIG® 180 DUAL Operating Manual should install and oper­ate this equipment.
• Machine must be plugged into a receptacle which is grounded per any national, local or other applicable electrical codes.
• The POWER MIG® 180 DUAL power switch is to be in the OFF (“O”) position when installing work cable and gun and when connecting power cord to input power.
SELECT SUITABLE LOCATION
Locate the POWER MIG® 180 DUAL in a dry location where there is free circulation of clean air into the lou­vers in the back and out the front of the unit. A loca­tion that minimizes the amount of smoke and dirt drawn into the rear louvers reduces the chance of dirt accumulation that can block air passages and cause overheating.
STACKING
POWER MIG® 180 DUAL cannot be stacked.
TILTING
Each machine must be placed on a secure, level sur­face, directly or on recommended cart. The machine may topple over if this procedure is not followed.
---------------------------------------------------
POWER MIG® 180 DUAL
A-2
IDENTIFY AND LOCATE COMPONENTS
INCLUDED COMPONENTS
• Wire Feeder Welder.
INSTALLATION
• .030 -.045(0.8-1.1mm) Knurled Drive Roll (Installed on Machine).
A-2
• Work Cable & Clamp.
• Magnum PRO 100L Welding Gun.
• 3 .035(0.9mm) Contact Tips (1 installed on the weld­ing gun).
• 3 .025(0.6mm) Contact Tips.
.035
.035
.025
.025
.025
• .025” -.035” (0.6 - 0.9mm) Inner Wire guide.
• .035” -.045” (0.9 - 1.1mm) Inner Wire Guide. (Installed on Machine).
• Outer Wire Guide (Installed on Machine).
INNER WIRE GUIDE .025-.035 (.6-.9mm)
INNER WIRE GUIDE .035-.045 (.9-1.1mm)
OUTER WIRE GUIDE
• Black Flux-cored Gasless Gun Nozzle.
• Copper MIG Gas Gun Nozzle. (Installed on welding
gun).
• Spool of .035(0.9mm) diameter NR-211MP Innershield Flux-cored Wire.
• Spool of .025(0.6mm) diameter L-56 MIG Wire.
NR-211 MP
L-56 MIG
WIRE
• Regulator • 2” Spindle Adapter
• Gas Hose (For 8” Reel of wire)
• Learn to Weld (LTW1 Manual) • DVD
• 120V Input Cord • Accessory Bag
REGULATOR
• .025-.030(0.6-0.9mm) Smooth Drive Roll. • .035(0.9mm) Smooth Drive Roll.
ACCESSORY BAG
POWER MIG® 180 DUAL
• 230V Input Cord
2" SPINDLE ADAPTER (FOR 8" REEL OF WIRE)
GAS HOSE
DVD
120V INPUT CORD
230V INPUT CORD
"LEARN TO WELD"
LTW1
B-1
OPERATION
B-1
Read entire operation section before operating the
WIRE FEEDER WELDERS.
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or electrode with skin or wet clothing. Insulate yourself from work and ground.
• Always wear dry insulating gloves.
FUMES AND GASES can be dangerous.
• Keep your head out of fumes.
• Use ventilation or exhaust to remove fumes from breathing zone.
WELDING SPARKS can cause fire or explosion.
• Keep flammable material away.
• Do not weld on closed contain­ers.
ARC RAYS can burn eyes and skin.
• Wear eye, ear and body protec­tion.
PRODUCT DESCRIPTION (PRODUCT CAPABILITIES)
This small portable wire feed welder is capable of MIG welding on steel, stainless steel, and aluminum. The wire feed welder is also capable of flux-cored welding on mild steel.
MIG welding stands for Metal Inert Gas welding and requires a shielding gas to protect the weld until it cools. Appropriate shielding gas based on the type of material you are welding can be purchased separately from your local welding gas distributor. MIG welding is ideal for welding on thinner and clean materials when a very clean excellent cosmetic looking weld is required. An example would be automotive body pan­els.
Self Sheilding Flux-cored Welding does not require a separate shielding gas to protect the weld since the welding wire has special additives known as flux to protect the weld until it cools. Flux-cored welding is ideal for medium to thicker material and if welding on painted or rusty steel. Flux-cored welding is also ideal in outdoor applications where windy conditions might blow the MIG shielding gas away from the weld. Flux­cored welding produces a good looking weld but does not produce an excellent weld appearance as MIG welding does.
Your machine includes the necessary items to weld with either the MIG or the flux-cored welding process on steel. To weld on stainless steel optional stainless steel welding wire can be purchased separately. This machine can weld aluminum using .035”(0.9mm) diameter 4043 aluminum welding wire. Since alu­minum welding wire is soft an optional aluminum spool gun is recommended for best results. A welding Procedure Decal is located inside machine door to help provide suggested settings for welding.
OPERATORʼS MANUAL
Observe all safety information throughout this manual.
------------------------------------------------------------
POWER MIG® 180 DUAL
COMMON WELDING ABBREVIATIONS
GMAW (MIG)
• Gas Metal Arc Welding
FCAW (Innershield or Outershield)
Flux Core Arc Welding
B-2
1
3
2
CONTROLS AND SETTINGS
This machine has the following controls:
OPERATION
B-2
See Figure B.1
1. POWER SWITCH – Turns power on and off to the
machine.
2. ARC VOLTAGE CONTROL – This knob sets the
output voltage of the machine. Along with wire feed speed (WFS) this control sets a weld procedure. Refer to the procedure decal on the inside wire drive compartment door to set a correct welding procedure based on type of material and thickness being welded.
3. WIRE FEED SPEED CONTROL (WFS) – The knob
sets the speed that the machine feeds wire. Along with arc voltage this control sets a weld procedure. Refer to the procedure decal on the inside wire drive compartment door to set a correct welding procedure based on type of material and thickness being welded.
See Figure B.2
4. GUN TRIGGER – Pressing the trigger activates the
wire drive to feed wire and energizes the output of the machine. Press the trigger to weld and release the trigger to stop welding.
FIGURE B.1
FIGURE B.2
5. WELDING GUN – Delivers wire and welding cur-
5c
rent to the weld. a. Gun Liner – wire travels through the liner from
the wire drive. The gun liner will feed .025” to .035” (0.6mm to 0.9mm) wire. The 180A machine can weld with .045”(1.1mm) wire if an optional
5b
5a
.035"(0.9mm) NR-211-MP
.045”(1.1mm) liner is installed in the gun.
b. Contact Tip – provides electrical contact to the
5
PRESS
WIRE SPOOL
wire.
c. Nozzle – When flux-cored welding the black noz-
4
zle protects the mounting threads on the gun. When MIG welding the copper nozzle funnels the
6
7
shielding gas to the weld.
6. WORK CLAMP & CABLE – Clamps to the work
piece being welded and completes the electrical welding circuit.
7. GUN TRIGGER CONNECTOR RECEPTACLE –
Plug the 4 pin gun trigger connector into this recep­tacle.
POWER MIG® 180 DUAL
B-3
OPERATION
B-3
(See Figure B.3)
8. WELDING GUN CONNECTOR BUSHING & THUMBSCREW – Provides electrical power to the
welding gun. The thumbscrew holds the welding gun into the connector block. (Front of Machine, Side Door and Wire Drive Cover have been removed for clarity of Items 8 and 9).
9. OUTPUT TERMINALS –These connections allow for changing the welding polarity of the machine depending on whether you are MIG welding or flux­cored welding.
(See Figure B.4)
10. WIRE SPOOL SPINDLE AND BRAKE – Holds a
4 inch diameter spool. Use the 2 inch I.D. spindle adapter included with the machine to use 8 inch diameter spools. The Wing Nut sets the brake friction to prevent the spool from over rotating when the trigger is released.
FIGURE B.3
8
9
FIGURE B.4
OPERATORʼS MANUAL
(See Figure B.5)
11. WIRE DRIVE & COMPONENTS – Feeds wire
from the wire spool through the drive and through the welding gun to the weld.
a. Top and Bottom Drive Roll – Drives the wire
through the drive system. The drive roll has a groove to match the specific wire type and diam­eter. Refer to Table B.1 for available drive rolls.
b. Inner & Outer Wire Guide – Guides the wire
between the Top and Bottom Drive Roll and through the wire drive. The inner guide has a groove to match a particular wire diameter. Refer to Table B.1 for available wire guides.
c. Drive Roll Tension Thumbscrew – Turning
clockwise increases the force on the drive rolls and turning counterclockwise decreases the force.
12. SPOOL GUN SWITCH - Pre-Installed switch per-
mits either spool gun welding with the Magnum 100SG or standard welding with the Magnum PRO 100L.
SPOOL GUN SWITCH
FIGURE B.5
TOP DRIVE ROLL
PRESSURE ARM
TENSION ADJUSTOR DOWN
INNER WIRE GUIDE REMOVED
LOWER DRIVE ROLL REMOVED
WIRE SPOOL .035" (0.9mm)
NR-211-MP
OUTER WIRE GUIDE REMOVED
POWER MIG® 180 DUAL
B-4
OPERATION
TABLE B.1
DRIVE ROLL AND WIRE GUIDES
B-4
Wire Diameter &
Drive Roll
Type
.025”(0.6mm) MIG wire
.025”/.030” (0.6mm/0.8mm)
Smooth Drive Roll
.030”(0.8mm) MIG wire
.035”(0.9mm) MIG wire
.030”(0.8mm) flux-cored .035”(0.9mm) flux-cored
.045”(1.1mm) flux-cored
.035”(0.9mm) Smooth Drive Roll
.030”/.045” (0.8mm/1.1mm)
Knurled Drive Roll
.030”/.045” (0.8mm/1.1mm)
Knurled Drive Roll
(See Figure B.6 for the following Items.)
12. CIRCUIT BREAKER – If the rated input current of
the machine is exceeded this circuit breaker will trip. Press to reset.
13. GAS INLET – Shielding gas connects to this inlet.
14. POWER CORD CONNECTION - Ensure power
cord is diconnected from input voltage supply prior to connecting or removing the cord from the machine. Connect the circular connector present on either input cord (120V or 230V) to the recepta­cle on the back of the machine. The power cord connector is secured to the receptacle by rotating the connectorʼs coupling ring clockwise, until the coupling ring latches on to the receptacle. Use only the appropriate (120V or 230V) power cords supplied by the Lincoln Electric Company.
Drive Roll Part
Number
KP2529-1
KP2529-2
KP2529-3
KP2529-3
12
Inner Wire Guide
.025”-.035”
(0.6mm-0.9mm)
Steel Wire Guide
.045”(1.1mm)
Steel
Wire Guide
FIGURE B.6
13
14
Inner Wire Guide
Part Number
KP2531-1
KP2531-2
SETTING UP AND MAKING A FLUX-CORED WELD
A. ITEMS NEEDED FOR
FLUX CORED WELDING
1. 035”(0.9mm) Contact Tip
.035
2. .025”-.035”(0.6mm-0.9mm) wire guide
INNER WIRE GUIDE .025-.035 (.6-.9mm)
3. Knurled Drive Roll
4. .035”(0.9mm) NR-211MP Flux­Cored Wire
.035 NR-211 MP
E
R
I
F
L
W
U
D
X
E
-
C
R
O
POWER MIG® 180 DUAL
5. Black Flux Cored gun nozzle
6. Welding Gun
7. Work Cable & Clamp
B-5
OPERATION
B-5
B. CONNECT LEADS AND CABLES ON
THE MACHINE
(See Figure B.7)
1. Open the case side door
2. Slide the connector end of the gun and cable through the hole in the machine front and into the gun connector bushing on the wire drive.
3. Make sure the gun connector end is seated fully into the wire drive and tighten the thumbscrew to secure the gun connector.
4. Plug the gun trigger lead connector into the 4 pin gun trigger receptacle on the machine front.
5. Wire Drive Polarity. Flux cored welding requires negative (-) polarity. Connect the short power cable from the wire drive to the negative (-) output terminal and tighten the Wing Nut.
6. Work Lead Connection. Slide the lugged end of the work cable through the hole in the machine front and place on the positive (+) output terminal and tighten Wing Nut.
LOCATE COMPONENTS TO CONNECT TO THE FRONT OF MACHINE
SLIDE CONNECTOR END HERE
(4 PIN) LEAD CONNECTOR
GUN AND CABLE
OPEN LATCH DOOR
TERMINAL END (FITS ON STUD INSIDE SEE FIGURE BELOW)
WORK CLAMP
THUMB SCREW TO TIGHTEN CONNECTOR BUSHING
CONNECTOR END ATTACH
(4 PIN) TRIGGER RECEPTACLE PLUGGED IN
FIGURE B.7
CASE SIDE DOOR
ALL COMPONENTS SHOWN CONNECTED (FRONT AND SIDE DOOR IS REMOVED FOR CLARITY)
WORK CLAMP
SHORT POWER CABLE NEGATIVE "-" OUTPUT TERMINAL
WORK LEAD CONNECTION POSITIVE "+" OUTPUT TERMINAL
OPERATORʼS MANUAL
C. LOAD WIRE SPOOL
(See Figure B.8)
1. Locate the 4"(102mm) diameter spool of .035”(0.9mm) NR-211MP flux-cored wire and place onto wire spool spindle. Orient the spool so that the wire feeds off the top of the spool.
2. Secure spool in place by tightening the wing nut against the against the spacer that holds the wire spool on the spindle.
3. Open the top drive roll pressure arm by rotating the tension adjustor arm down and pivoting the drive roll pressure arm up.
4. Remove the outer wire guide.
4a. Slide gun out of drive slightly.
5. Remove the lower drive roll and inner wire guide.
6.
Install the .025”-.035”(0.6mm-0.9mm) inner wire guide.
7. Install the .030”/.045”(0.8mm/1.1mm) knurled lower drive roll.
FIGURE B.8
TOP DRIVE ROLL PRESSURE ARM
TENSION ADJUSTOR DOWN
INNER WIRE GUIDE REMOVED
LOWER DRIVE ROLL REMOVED
WIRE SPOOL .035" (0.9mm)
NR-211-MP
OUTER WIRE GUIDE REMOVED
8. Carefully unwind and straighten the first six inches of
welding wire from the spool. Do not let the end of the wire go to prevent the wire from unspooling.
POWER MIG® 180 DUAL
B-6
OPERATION
B-6
(See Figure B.9)
9. Feed the wire through the wire drive inlet along the inner wire guide groove and into the wire drive outlet on the gun side.
10. Close the top drive roll pressure arm and secure by pivoting the tension adjustor back to the up position.
11. Re-install the outer wire guide.
(See Figure B.10)
12. Remove the nozzle from the gun and contact tip and straighten the gun out flat.
13. Turn the machine power to on and depress the gun trigger to feed the wire through the gun liner until the wire comes out of the threaded end of the gun several inches. (See figure B.11)
14. When trigger is released spool of wire should not unwind. Adjust wire spool brake accordingly.
WARNING
MOVING PARTS AND ELECTRICAL CONTACT CAN CAUSE INJURY OR BE FATAL.
•When the gun trigger is depressed drive rolls, spool of wire and electrode are ELECTRICALLY LIVE (HOT).
• Keep away from moving parts and
pinch points.
• Keep all Doors, Covers, panels and
guards securely in place. DO NOT REMOVE OR CONCEAL WARN­ING LABELS.
----------------------------------------------------------------------------
15. Install the .035”(0.9mm) contact tip
SLIDE WIRE INTO GUN CONNECTOR SIDE
REMOVED NOZZLE
REMOVED CONTACT TIP
LAY CABLE AND GUN STRAIGHTEN IN THIS POSITION
FEED WIRE APPROXIMATELY 4.00" FROM THE GUN TUBE END
DEPRESS TRIGGER TO ACTIVATE WIRE, WHICH FEEDS THE WIRE THRU THE LINER.
TOP DRIVE ROLL PRESSED AGAINST LOWER DRIVE ROLL
FIGURE B.10
FIGURE B.11
ON/OFF SWITCH
FIGURE B.9
TENSION ADJUSTOR LOCKED IN POSITION
LOWER DRIVE ROLL BE SURE WIRE IS IN GROOVE
WIRE SPOOL .035" (0.9mm)
NR-211-MP
.035"(0.9mm) NR-211-MP
WIRE SPOOL
DIRECTION OF WIRE
.035"(0.9mm) NR-211-MP
WIRE SPOOL
PLUG IN POWER INPUT CORD
ROTATION
16. In
stall the black flux cored welding nozzle to the
gun.
17. Trim the wire stickout to 3/8”(9.5mm) from the con­tact tip. (See Figure B.12)
18. Close the case side door. The machine is now ready to weld.
19. Read "Learn to Weld" (LTW1) that is included with the machine or watch the "How to Weld" DVD included with the machine.
20. Based on the thickness of the material you are going to weld and the type and diameter of the welding wire set the voltage and the wire feed speed per the procedure decal attached to the inside of the wire drive compartment door.
POWER MIG® 180 DUAL
TRIM WIRE STICKOUT 3/8"(9.5mm) from the Contact Tip
WORK CLAMP AND CABLE
FIGURE B.12
INSTALL .035 CONTACT TIP
INSTALL BLACK FLUX-CORED NOZZLE
B-7
5
OPERATION
SETTING UP AND MAKING A MIG WELD
B-7
A. ITEMS NEEDED FOR MIG WELDING
1. 025”(0.6mm) Contact Tip
.02
2. 025”-035”(0.6mm-0.9mm) Inner wire guide
INNER WIRE GUIDE .025-.035
.025-.035
3. .025”(0.6mm) Drive Roll
6. Welding Gun
7. Work Cable & Clamp
OPERATORʼS MANUAL
8. Gas Regulator & Gas Line
.025
4. .025”(0.6mm) SuperArc L-56 Solid MIG Wire
L-56 MIG
WIRE
5. Copper gun nozzle
9. Bottle of 75/25 Ar/
CO2shielding gas (or 100% shielding gas) (note this requires a adapter which is sold separately.
MALE END
CO
2
100%
(REQUIRES ADAPTER SOLD SEPARATELY)
FEMALE END
CO2regulator
75/25
MIXES
CO
2
POWER MIG® 180 DUAL
B-8
B. INSTALL SHIELDING GAS
OPERATION
B-8
FIGURE B.13
MIG welding requires an appropriate bottle of shielding gas. For mild steel either a cylinder bottle of Ar/CO
or
2
100% CO2can be used. Refer to the following instruc­tions to properly connect shielding gas to the machine.
WARNING
CYLINDER may explode if dam­aged. Keep cylinder upright and chained to support
• Keep cylinder away from areas where it may be damaged.
• Never lift welder with cylinder attached.
• Never allow welding electrode to
touch cylinder.
• Keep cylinder away from welding or other live electrical circuits.
-----------------------------------------------------------------------
WARNING
BUILDUP OF SHIELDING GAS may harm health or kill.
• Shut off shielding gas supply when not in use.
1. Secure the cylinder to a wall or other stationary support to prevent the cylinder from falling over. Insulate the cylinder from the work circuit and earth ground. Refer to Figure B.13.
2. With the cylinder securely installed, remove the cylinder cap. Stand to one side away from the outlet and open the cylinder valve very slightly for an instant. This blows away any dust or dirt which may have accumulated in the valve out­let.
MALE END
CO
100%
FEMALE END
75/25
MIXES
2
REGULATOR ADAPTER
PLASTIC WASHER
S19298
3. Attach the flow regulator to the cylinder valve and tighten the union nut securely with a wrench.
NOTE: If connecting to 100%
CO2cylinder, a
CO
2
regulator adapter is required. Purchase separately S19298
CO2adapter be sure to install plastic washer included in the fitting on the bottle side.(See Figure B.13 )
4. Refer to Figure B.13. Attach one end of inlet gas hose to the outlet fitting of the flow regulator and tighten the union nut securely with a wrench. Connect the other end to the machine Solenoid Inlet Fitting (5/8-18 female threads — for CGA — 032 fitting). Make cer­tain the gas hose is not kinked or twisted.
SHIELDING GAS
1. For
2. Set gas flow rate for 30 to 40 cubic feet per hour (14
3. Keep the cylinder valve closed, except when using
CO2, open the cylinder very slowly. For argon­mixed gas, open cylinder valve slowly a fraction of a turn. When the cylinder pressure gauge pointer stops moving, open the valve fully.
to 18 I/min.) under normal conditions, increase to as high as 40 to 50 CFH (18 to 23.5 I/min.) for out of postion welding.
the machine.
WARNING
BE SURE TO KEEP YOUR FACE AWAY FROM THE VALVE OUTLET WHEN “CRACKING” THE VALVE. Never stand directly in front of or behind the flow regulator when opening the cylinder valve. Always stand to one side.
-----------------------------------------------------------------------
POWER MIG® 180 DUAL
B-9
OPERATION
C. CONNECT LEADS AND CABLES ON
THE MACHINE
(See Figure B.14)
1. Open the case side door.
2. Slide the connector end of the gun and cable through the hole of the machine front and into the gun connector bushing on the wire drive.
3. Make sure the gun connector end is seated fully into the wire drive and tighten the thumbscrew to secure the gun.
4. Plug the gun trigger lead connector into the 4 pin gun trigger receptacle on the machine front.
5. Wire Drive Polarity. MIG welding requires Positive (+) polarity. Connect the short power cable from the wire drive to the positive (+) output terminal and tighten the thumbscrew.
LOCATE COMPONENTS TO CONNECT TO THE FRONT OF MACHINE
SLIDE CONNECTOR END HERE
(4 PIN) LEAD CONNECTOR
GUN AND CABLE
FIGURE B.14
OPEN LATCH DOOR
TERMINAL END (FITS ON STUD INSIDE SEE FIGURE BELOW)
WORK CLAMP
THUMB SCREW TO TIGHTEN CONNECTOR BUSHING
CASE SIDE DOOR
ALL COMPONENTS SHOWN CONNECTED (FRONT AND SIDE DOOR IS REMOVED FOR CLARITY)
WORK LEAD CONNECTION NEGATIVE "-" OUTPUT TERMINAL
B-9
OPERATORʼS MANUAL
6. Work Lead Connection. Slide the lugged end of the work cable through the hole in the machine front and place on the negative (-) output terminal and tighten thumbscrew.
D. LOAD WIRE SPOOL
(See Figure B.15)
1. Locate the 4"(102mm) diameter spool of .025”(0.6mm) L-56 solid MIG wire and place onto wire spool spindle. Orient the spool so that the wire feeds off the top of the spool.
2. Secure spool in place by tightening the wing nut against the against the spacer that holds the wire spool on the spindle.
3. Open the top drive roll pressure arm by rotating the tension adjustor arm down and pivoting the idle roll pressure arm up.
4. Remove the outer wire guide.
CONNECTOR END ATTACH
(4 PIN) TRIGGER RECEPTACLE PLUGGED IN
FIGURE B.15
TOP DRIVE ROLL PRESSURE ARM
TENSION ADJUSTOR DOWN
WORK CLAMP
WIRE SPOOL .025" (0.6mm)
L
-
5
SHORT POWER CABLE POSITIVE "+" OUTPUT TERMINAL
G
I
M
6
D
S
I
L
O
4a. Slide gun out of drive slightly.
5. Remove the lower drive roll and inner wire guide.
6. Install the .025”-.035”(0.6mm-0.9mm) inner wire guide.
7. Install the .025”(0.6mm) smooth grooved lower drive roll.
8. Carefully unwind and straighten the first six inches of welding wire from the spool. Do not let the end of the wire go to prevent the wire from unspooling.
POWER MIG® 180 DUAL
INNER WIRE GUIDE REMOVED
LOWER DRIVE ROLL REMOVED
OUTER WIRE GUIDE REMOVED
B-10
OPERATION
(See Figure B.16)
9. Feed the wire through the wire drive inlet along the inner wire guide groove and into the wire drive out­let on the gun side.
TOP IDLER ROLL PRESSED AGAINST LOWER DRIVE ROLL
FIGURE B.16
TENSION ADJUSTOR LOCKED IN POSITION
B-10
10. Close the top drive roll pressure arm and secure
by pivoting the tension adjustor back to the up position.
11. Re-install the outer wire guide.
(See Figure B.17)
12. Remove the nozzle from the gun and contact tip
and straighten the gun out flat.
13. Turn the machine power to on and depress the
gun trigger to feed the wire through the gun liner until the wire comes out of the threaded end of the gun several inches. (See Figure B.18)
14. When trigger is released spool of wire should not
unwind. Adjust wire spool brake accordingly.
WARNING
MOVING PARTS AND ELECTRICAL CONTACT CAN CAUSE INJURY OR BE FATAL.
•When the gun trigger is depressed drive rolls, spool of wire and elec­trode are ELECTRICALLY LIVE (HOT).
• Keep away from moving parts and pinch points.
• Keep all Doors, Covers, panels and guards securely in place.
DO NOT REMOVE OR CONCEAL WARNING LABELS.
-----------------------------------------------------------------------
15. Install the .025”(0.6mm) contact tip.
16. Install the Copper gas MIG welding nozzle to the gun.
SLIDE WIRE INTO GUN CONNECTOR SIDE
REMOVED NOZZLE
REMOVED CONTACT TIP
LAY CABLE AND GUN STRAIGHTEN IN THIS POSITION
FEED WIRE APPROXIMATELY 4.00" FROM THE GUN TUBE END
DEPRESS TRIGGER TO ACTIVATE WIRE, WHICH FEEDS THE WIRE THRU THE LINER.
FIGURE B.17
FIGURE B.18
ON/OFF SWITCH
DRIVE ROLL BE SURE WIRE IS IN GROOVE
WIRE SPOOL .025" (0.6mm)
L
-
5
6
S
O
L
WIRE SPOOL .025" (0.6mm)
L
-
DIRECTION OF WIRE
G
I
M
I
D
WIRE SPOOL .025" (0.6mm)
L
G
-
I
5
6
M
S
O
D
L
I
PLUG IN POWER INPUT CORD
G
I
5
6
M
S
O
D
L
I
ROTATION
17. Trim the wire stickout to 3/8”(9.5mm) from the nozzle
end. (See Figure B.19)
18. Close the case side door. The machine is now ready to weld.
19. Read "Learn to Weld" (LTW1) that is included with the machine or watch the "How to Weld" DVD includ­ed with the machine.
20. Based on the thickness of the material you are going
to weld and the type and diameter of the welding wire set the voltage and the wire feed speed per the procedure decal attached to the inside of the wire drive compartment door.
POWER MIG® 180 DUAL
WORK CLAMP AND CABLE
FIGURE B.19
TRIM WIRE STICKOUT 3/8"(9.5mm) from the Copper Nozzle
INSTALL .025 CONTACT TIP
INSTALL COPPER NOZZLE
B-11
OPERATION
SETTING UP AND MAKING A ALUMINUM WELD USING SPOOL GUN
1. Disconnect Magnum Pro 100L Gun.
2. Install optional K2532-1 Magnum 100SG spool gun per instructions included with gun.
3. Set Gun selector toggle switch to Spool Gun posi­tion. (See Figure B.20)
4. Connect a bottle of 100% Argon shielding Gas per previous section.
5. Follow the MIG welding steps in the previous sec­tion.
FIGURE B.20
B-11
OPERATORʼS MANUAL
6. Turn machine on and make weld per recommended settings on Procedure Decal inside machine door.
POWER MIG® 180 DUAL
C-1
K2525-1 - Spot Timer Kit
Timer kit, when turned on, allows you to set a fixed weld time so that when the gun trigger is pulled the machine will weld for a fixed time period up to 10 sec­onds. Ideal for making consistent spot welds when welding on thin sheet metal.
K2528-1 - 045 Innershield Kit (For 230V models)
Includes everything needed to weld with .045 diame­ter Innershield wire. Includes an .035/.045 Magnum™ 100L gun liner, .045 Contact Tip, gasless nozzle, knurled drive roll, .035-.045 inner wire guide, and a 10 lb. (4.5kg) spool of .045"(0.9mm) Innershield® NR®-212 wire.
K2532-1 - Magnum 100SG Spool Gun
Designed to easily feed small 4" diameter (1lb. spools of) .030 or .035 aluminum wire. Includes gun, adapter kit, three extra .035 contact tips, gas nozzle, and spool of Superglaze 4043 .035" diameter welding wire. Packaged in a convenient carry case.
ACCESSORIES
C-1
K2377-1 - Small Canvas Cover
Protect your machine when not in use. Made from attractive red canvas that is flame retardant, mildew resistant and water repellent. Includes a convenient side pocket to hold welding gun.
For additional Optional and Miscellaneous Parts (See Parts Pages)
POWER MIG® 180 DUAL
C-2
ACCESSORIES
K520Utility Cart
Heavy duty cart stores and transports welder, 150 cubic foot shielding gas cylinder, welding cables and accessories. Includes stable platforms for welder and gas bottle platform, lower tray for added storage capacity and adjustable height handle.
For mounting welding machines to K520 carts that do not have slotted mounting holes. Drill 9/32” holes (3 places) into the cart top as shown and attach the welding machine to the cart with the proper hardware shown.
C-2
1/4"-20 X 1/2" Hex Head Cap Screw (2 Required)
OPERATORʼS MANUAL
1/4"-20 X 1" Thread Forming Screw (1 Required)
8-1/16"
3-11/16"
3-3/4"
9/32" DRILL 3 PLACES
1/4"-20
Flange Nut
(2 Required)
3-13/32"
4"
16"
POWER MIG® 180 DUAL
C-3
ACCESSORIES
K2275-1 - Welding Cart
Lightweight cart stores and transports welder, 80 cubic foot shielding gas cylinder, welding cables and accessories. Includes an angled top shelf for easy access to controls, lower tray for added storage capacity, a sturdy fixed handle and convenient cable wrap hanger.
For mounting welding machines to K2275-1 carts that do not have slotted mounting holes. Drill 9/32” holes (3 places) into the cart top as shown and attach the welding machine to the cart with the proper hardware shown.
C-3
1/4"-20 X 1/2" Hex Head Cap Screw (2 Required)
1/4"-20 X 1" Thread Forming Screw (1 Required)
1/4"-20 Flange Nut (2 Required)
7-9/16"
3-3/16"
1-1/4"
9/32" DRILL 3 PLACES
2-15/16"
1-1/2"
13-1/2"
POWER MIG® 180 DUAL
D-1
MAINTENANCE
D-1
MAINTENANCE SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Disconnect input power by remov­ing plug from receptacle before working inside POWER MIG® 180 DUAL.
Use only grounded receptacle. Do not touch elec­trically “hot” parts inside POWER MIG® 180 DUAL.
• Have qualified personnel do the maintenance and trouble shooting work.
-----------------------------------------------------------------------
ROUTINE MAINTENANCE
POWER SOURCE COMPARTMENT
No user serviceable parts inside! Do not attempt to perform service in the power source (fixed) side of the POWER MIG® 180 DUAL. Take the unit to an autho­rized Lincoln Service Center if you experience prob­lems. NO maintenance is required.
In extremely dusty locations, dirt may clog the air pas­sages causing the welder to run hot with premature tripping of thermal protection. If so, blow dirt out of the welder with low pressure air at regular intervals to eliminate excessive dirt and dust build-up on internal parts.
GUN AND CABLE MAINTENANCE
FOR MAGNUM™ PRO 100L GUN
Gun Cable Cleaning
Clean cable liner after using approximately 300 lbs (136 kg) of solid wire or 50 lbs (23 kg) of flux-cored wire. Remove the cable from the wire feeder and lay it out straight on the floor. Remove the contact tip from the gun. Using low pressure air, gently blow out the cable liner from the gas diffuser end.
CAUTION
Excessive pressure at the start may cause the dirt to form a plug.
Flex the cable over its entire length and again blow out the cable. Repeat this procedure until no further dirt comes out.
Contact Tips, Nozzles, and Gun Tubes
1. Dirt can accumulate in the contact tip hole and restrict wire feeding. After each spool of wire is used, remove the contact tip and clean it by push­ing a short piece of wire through the tip repeatedly. Use the wire as a reamer to remove dirt that may be adhering to the wall of the hole through the tip.
2. Replace worn contact tips as required. A variable or “hunting” arc is a typical symptom of a worn con­tact tip. To install a new tip, choose the correct size contact tip for the electrode being used (wire size is stenciled on the side of the contact tip) and screw it snugly into the gas diffuser.
3. Remove spatter from inside of gas nozzle and from tip after each 10 minutes of arc time or as required.
OPERATORʼS MANUAL
WIRE FEED COMPARTMENT
1. When necessary, vacuum accumulated dirt from gearbox and wire feed section.
2. Occasionally inspect the incoming guide tube and clean inside diameter if necessary.
3. Motor and gearbox have lifetime lubrication and require no maintenance.
FAN MOTOR
Has lifetime lubrication — requires no maintenance.
WIRE REEL SPINDLE
Requires no maintenance. Do not lubricate shaft.
POWER MIG® 180 DUAL
4. Be sure the gas nozzle is fully screwed onto the diffuser for gas shielded processes. For the Innershield®process, the gasless nozzle should screw onto the diffuser.
5. To remove gun tube from gun, remove gas nozzle or gasless nozzle and remove diffuser from gun tube. Remove both collars from each end of the gun handle and separate the handle halves. Loosen the locking nut holding the gun tube in place against the gun end cable connector. Unscrew gun tube from cable connector. To install gun tube, screw the locking nut on the gun tube as far as possible. Then screw the gun tube into the cable connector until it bottoms. Then unscrew (no more than one turn) the gun tube until its axis is perpendicular to the flat sides of the cable connec­tor and pointed in the direction of the trigger. Tighten the locking nut so as to maintain the proper relationship between the gun tube and the cable connector. Replace the gun handle, trigger and dif­fuser. Replace the gas nozzle or gasless nozzle.
D-2
MAINTENANCE
OVERLOAD PROTECTION
Output Overload
The POWER MIG® 180 DUAL is equipped with a cir­cuit breaker and a thermostat which protects the machine from damage if maximum output is exceed­ed. The circuit breaker button will extend out when tripped. The circuit breaker must be manually reset.
D-2
1-1/4”(31.8 mm) Liner Trim Length
Gas Diffuser
Thermal Protection
The POWER MIG® 180 DUAL has a rated output duty cycle as defined in the Technical Specification page. If the duty cycle is exceeded, a thermal protector will shut off the output until the machine cools to a reason­able operating temperature. This is an automatic func­tion of the POWER MIG® 180 DUAL and does not require user intervention. The fan continues to run during cooling.
Electronic Wire Drive Motor Protection
The POWER MIG® 180 DUAL has built-in protection for wire drive motor overload.
CHANGING LINER
NOTICE: The variation in cable lengths prevents the interchangeability of liners. Once a liner has been cut for a particular gun, it should not be installed in anoth­er gun unless it can meet the liner cutoff length requirement. Refer to Figure D.2.
1. Remove the gas nozzle from the gun by unscrew­ing counter-clockwise.
2. Remove the existing contact tip from the gun by unscrewing counter-clockwise.
3. Remove the gas diffuser from the gun tube by unscrewing counter-clockwise.
4. Lay the gun and cable out straight on a flat surface. Loosen the set screw located in the brass connec­tor at the wire feeder end of the cable. Pull the liner out of the cable.
Gas Nozzle or
Set Screw Brass Cable
Connector
Liner Assembly (Liner bushing to be sealed tight against brass cable connector)
Gasless Nozzle
FIGURE D.2
Liner trim length
8. Screw the gas diffuser onto the end of the gun tube and securely tighten.
9. Replace the contact tip and nozzle.
GUN HANDLE PARTS
The gun handle consists of two halves that are held together with a collar on each end. To open up the handle, turn the collars approximately 60 degrees counter-clockwise until the collar reaches a stop. Then pull the collar off the gun handle. If the collars are diffi­cult to turn, position the gun handle against a corner, place a screwdriver against the tab on the collar and give the screwdriver a sharp blow to turn the collar past an internal locking rib. See Figure D.3.
5. Insert a new untrimmed liner into the connector end of the cable. Be sure the liner bushing is stenciled appropriately for the wire size being used.
6. Fully seat the liner bushing into the connector. Tighten the set screw on the brass cable connector. At this time, the gas diffuser should not be installed onto the end of the gun tube.
7. With the gas nozzle and diffuser removed from the gun tube, be sure the cable is straight, and then trim the liner to the length shown in the Figure D.2. Remove any burrs from the end of the liner.
POWER MIG® 180 DUAL
¢
Counter-clockwise
FIGURE D.3
E-1
TROUBLESHOOTING
HOW TO USE TROUBLESHOOTING GUIDE
WARNING
Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
__________________________________________________________________________
E-1
This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled “PROBLEM (SYMP­TOMS)”. This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting.
Step 2. POSSIBLE CAUSE.
The second column labeled “POSSIBLE CAUSE” lists the obvious external possibilities that may contribute to the machine symptom.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the Possible Cause, generally it states to contact your local Lincoln Authorized Field Service Facility.
If you do not understand or are unable to perform the Recommended Course of Action safely, contact your local Lincoln Authorized Field Service Facility.
OPERATORʼS MANUAL
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER MIG® 180 DUAL
E-2
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-2
PROBLEMS (SYMPTOMS)
Major physical or electrical damage is evident.
No wire feed, weld output or gas flow when gun trigger is pulled. Fan does NOT operate.
No wire feed, weld output or gas flow when gun trigger is pulled. Fan operates normally.
POSSIBLE CAUSE
OUTPUT PROBLEMS
“Do not Plug in machine or turn it on”. Contact your local Authorized Field Service Facility.
1. Make sure correct voltage is applied to the machine.
2. Make certain that power switch is in the ON position.
3. Make sure circuit breaker is reset.
1. The thermostat may be tripped due to overheating. Let machine cool. Weld at lower duty cycle.
2. Check for obstructions in air flow. Check Gun Trigger connec­tions. See Installation section.
RECOMMENDED COURSE OF ACTION
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
PROBLEMS (SYMPTOMS)
No wire feed when gun trigger is pulled. Fan runs, gas flows and machine has correct open circuit voltage (33V) – weld output.
3. Gun trigger may be faulty.
POSSIBLE CAUSE
FEEDING PROBLEMS
1. If the wire drive motor is running make sure that the correct drive rolls are installed in the machine.
2. Check for clogged cable liner or contact tip.
3. Check for proper size cable liner and contact tip.
4. Check if the spool gun switch,
located in the wire drive compart­ment, is set to the desired loca­tion.
RECOMMENDED COURSE OF ACTION
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER MIG® 180 DUAL
E-3
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-3
PROBLEMS (SYMPTOMS)
Low or no gas flow when gun trigger is pulled. Wire feed, weld output and fan operate normally.
PROBLEMS (SYMPTOMS)
Arc is unstable – Poor starting.
POSSIBLE CAUSE
GAS FLOW PROBLEMS
1. Check gas supply, flow regulator and gas hoses.
2. Check gun connection to machine for obstruction or leaky seals.
POSSIBLE CAUSE
WELDING PROBLEMS
1. Check for correct input voltage to machine.
RECOMMENDED COURSE OF ACTION
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
OPERATORʼS MANUAL
RECOMMENDED COURSE OF ACTION
2. Check for proper electrode polarity for process.
3. Check gun tip for wear or dam­age and proper size – Replace.
4. Check for proper gas and flow rate for process. (For MIG only.)
5. Check work cable for loose or faulty connections.
6. Check gun for damage or breaks.
7. Check for proper drive roll orien­tation and alignment.
8. Check liner for proper size.
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER MIG® 180 DUAL
F-1
ENHANCED DIAGRAM
DIAGRAMS
F-1
WARNING
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The
specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.
POWER MIG® 180 DUAL
Loading...