Quality Program Certified by
ABS Quality Evaluations, Inc.
to ISO 9001 Requirements.
CERTIFICATE NUMBER: 30273
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation
... and thoughtful operation on
your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT READING THIS MANUAL AND THE
SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And,
most importantly, think before
you act and be careful.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
i
SAFETY
i
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents
are known to the State of California to cause cancer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
1.c. Do not add the fuel near an open flame
welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporizing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.
1.d. Keep all equipment safety guards, covers and devices in
position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving
parts when starting, operating or repairing equipment.
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fi elds m ay interf ere wi th some pa cemak ers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
Route the electrode and work cables together - Secure
2.d.1.
them with tape when possible.
2.d.2. Never coil the e lectrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
ii
SAFETY
ii
ELECTRIC SHOCK can
kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES
can be dangerous.
5.a. Welding ma y produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases. When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and within applicable OSHA PEL and
ACGIH TLV limits using local exhaust or mechanical
ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required.
Additional precautions are also required when welding
on galvanized steel.
5. b. The operation of welding fume control equipment is affected
by various factors including proper use and positioning of
the equipment, maintenance of the equipment and the specific welding procedure and application involved. Worker
exposure level should be checked upon installation and
periodically thereafter to be certain it is within applicable
OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
form phosgene, a highly toxic gas, and other irritating products.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
vapors
OPERATORʼS MANUAL
to
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employer’s safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
iii
SAFETY
iii
WELDING and CUTTING
SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f.
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains
or cables until they fail.
6.h. Also see item 1.c.
the welding sparks from starting a fire.
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode
if damaged.
7.a. Use on ly com pr essed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Re ad and foll ow the inst ru ctions o n c ompressed gas
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Ins tall equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturer’s
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention
During Welding, Cutting and Other Hot Work”, available
from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma
022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Refer to http://www.lincolnelectric.com/safety for additional safety information.
NOTES
OPERATORʼS MANUAL
Thank You
iviv
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln
Electric for advice or information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customerʼs particular purpose,
with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any
warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control
of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in
applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com
for any updated information.
CUSTOMER ASSISTANCE POLICY
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.
Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet
accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
Your Product”. Please complete the form and submit your registration.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WEB SITE at www.lincolnelectric.com. Choose “Support” and then “Register
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
INSTALLATION
A-1A-1
TECHNICAL SPECIFICATIONS
180 Amp unit (K3018-1)
INPUT – SINGLE PHASE ONLY
Standard Voltage/FrequencyInput Current
230 V 60 Hz
208 V 60 Hz20 Amps @ rated output
120 V 60 Hz
RATED OUTPUT
Voltage/Duty
230 V 30% 130 Amps20
208 V 30%130 Amps17.6
120 V 20%90 Amps19.5
CycleCurrentVoltage at Rated Amperes
OUTPUT
Welding Current RangeOpen Circuit VoltageWire Speed Range
(208V / 230V) 30-180 Amps34 V50 - 500 in/min.
(120V) 30-140 Amps33 V(1.3 - 12.7 m/min.)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Voltage/Frequency Fuse or Breaker Size
230V / 208V 60 Hz40 Amp 20 Lincoln Electric
120V 60 Hz20 Amp
2
1
Input Amps Power Cord
20 Lincoln Electric
Part Number:
Part Number:
M22590
M22589
OPERATORʼS MANUAL
PHYSICAL DIMENSIONS
HeightWidthDepthWeight
14.08 in10.37 in18.78 in66 Ibs
357.6 mm263.4 mm477.6 mm30 kg
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
2
Requirements for maximum output: In order to utilize the maximum output capability of the machine, a branch circuit
capable of 30 amps @ 120 volts, 60Hz is required.
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Only qualified personnel should perform
this installation.
• Only personnel that have read and understood the POWER MIG® 180 DUAL
Operating Manual should install and operate this equipment.
• Machine must be plugged into a receptacle
which is grounded per any national, local
or other applicable electrical codes.
• The POWER MIG® 180 DUAL power switch
is to be in the OFF (“O”) position when
installing work cable and gun and when
connecting power cord to input power.
SELECT SUITABLE LOCATION
Locate the POWER MIG® 180 DUAL in a dry location
where there is free circulation of clean air into the louvers in the back and out the front of the unit. A location that minimizes the amount of smoke and dirt
drawn into the rear louvers reduces the chance of dirt
accumulation that can block air passages and cause
overheating.
STACKING
POWER MIG® 180 DUAL cannot be stacked.
TILTING
Each machine must be placed on a secure, level surface, directly or on recommended cart. The machine
may topple over if this procedure is not followed.
Read entire operation section before
operating the
WIRE FEEDER WELDERS.
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live
parts or electrode with skin or
wet clothing. Insulate yourself
from work and ground.
• Always wear dry insulating
gloves.
FUMES AND GASES can be
dangerous.
• Keep your head out of fumes.
• Use ventilation or exhaust to
remove fumes from breathing
zone.
WELDING SPARKS can
cause fire or explosion.
• Keep flammable material away.
• Do not weld on closed containers.
ARC RAYS can burn eyes
and skin.
• Wear eye, ear and body protection.
PRODUCT DESCRIPTION (PRODUCT
CAPABILITIES)
This small portable wire feed welder is capable of MIG
welding on steel, stainless steel, and aluminum. The
wire feed welder is also capable of flux-cored welding
on mild steel.
MIG welding stands for Metal Inert Gas welding and
requires a shielding gas to protect the weld until it
cools. Appropriate shielding gas based on the type of
material you are welding can be purchased separately
from your local welding gas distributor. MIG welding
is ideal for welding on thinner and clean materials
when a very clean excellent cosmetic looking weld is
required. An example would be automotive body panels.
Self Sheilding Flux-cored Welding does not require a
separate shielding gas to protect the weld since the
welding wire has special additives known as flux to
protect the weld until it cools. Flux-cored welding is
ideal for medium to thicker material and if welding on
painted or rusty steel. Flux-cored welding is also ideal
in outdoor applications where windy conditions might
blow the MIG shielding gas away from the weld. Fluxcored welding produces a good looking weld but does
not produce an excellent weld appearance as MIG
welding does.
Your machine includes the necessary items to weld
with either the MIG or the flux-cored welding process
on steel. To weld on stainless steel optional stainless
steel welding wire can be purchased separately. This
machine can weld aluminum using .035”(0.9mm)
diameter 4043 aluminum welding wire. Since aluminum welding wire is soft an optional aluminum
spool gun is recommended for best results. A welding
Procedure Decal is located inside machine door to
help provide suggested settings for welding.
OPERATORʼS MANUAL
Observe all safety information throughout
this manual.
output voltage of the machine. Along with wire feed
speed (WFS) this control sets a weld procedure.
Refer to the procedure decal on the inside wire
drive compartment door to set a correct welding
procedure based on type of material and thickness
being welded.
3. WIRE FEED SPEED CONTROL (WFS) – The knob
sets the speed that the machine feeds wire. Along
with arc voltage this control sets a weld procedure.
Refer to the procedure decal on the inside wire
drive compartment door to set a correct welding
procedure based on type of material and thickness
being welded.
See Figure B.2
4. GUN TRIGGER – Pressing the trigger activates the
wire drive to feed wire and energizes the output of
the machine. Press the trigger to weld and release
the trigger to stop welding.
FIGURE B.1
FIGURE B.2
5. WELDING GUN – Delivers wire and welding cur-
5c
rent to the weld.
a. Gun Liner – wire travels through the liner from
the wire drive. The gun liner will feed .025” to
.035” (0.6mm to 0.9mm) wire. The 180A machine
can weld with .045”(1.1mm) wire if an optional
5b
5a
.035"(0.9mm)
NR-211-MP
.045”(1.1mm) liner is installed in the gun.
b. Contact Tip – provides electrical contact to the
5
PRESS
WIRE SPOOL
wire.
c. Nozzle – When flux-cored welding the black noz-
4
zle protects the mounting threads on the gun.
When MIG welding the copper nozzle funnels the
6
7
shielding gas to the weld.
6. WORK CLAMP & CABLE – Clamps to the work
piece being welded and completes the electrical
welding circuit.
7. GUN TRIGGER CONNECTOR RECEPTACLE –
Plug the 4 pin gun trigger connector into this receptacle.
POWER MIG® 180 DUAL
B-3
OPERATION
B-3
See Figure B.3
8. WELDING GUN CONNECTOR BUSHING &
THUMBSCREW – Provides electrical power to the
welding gun. The thumbscrew holds the welding
gun into the connector block. (Front of Machine,
Side Door and Wire Drive Cover have been
removed for clarity of Items 8 and 9).
9. OUTPUT TERMINALS –These connections allow
for changing the welding polarity of the machine
depending on whether you are MIG welding or fluxcored welding.
See Figure B.4
10. WIRE SPOOL SPINDLE AND BRAKE – Holds a
4 inch diameter spool. Use the 2 inch I.D. spindle
adapter included with the machine to use 8 inch
diameter spools. The Wing Nut sets the brake
friction to prevent the spool from over rotating
when the trigger is released.
FIGURE B.3
8
9
FIGURE B.4
OPERATORʼS MANUAL
See Figure B.5
11. WIRE DRIVE & COMPONENTS – Feeds wire
from the wire spool through the drive and through
the welding gun to the weld.
a. Top and Bottom Drive Roll – Drives the wire
through the drive system. The drive roll has a
groove to match the specific wire type and diameter. Refer to Table B.1 for available drive rolls.
b. Inner & Outer Wire Guide – Guides the wire
between the Top and Bottom Drive Roll and
through the wire drive. The inner guide has a
groove to match a particular wire diameter.
Refer to Table B.1 for available wire guides.
c. Drive Roll Tension Thumbscrew – Turning
clockwise increases the force on the drive rolls
and turning counterclockwise decreases the
force.
12. SPOOL GUN SWITCH - Pre-Installed switch per-
mits either spool gun welding with the Magnum
100SG or standard welding with the Magnum
PRO 100L.
SPOOL GUN SWITCH
FIGURE B.5
TOP DRIVE ROLL
PRESSURE ARM
TENSION ADJUSTOR DOWN
INNER WIRE GUIDE REMOVED
LOWER DRIVE ROLL REMOVED
WIRE SPOOL
.035" (0.9mm)
NR-211-MP
OUTER WIRE GUIDE REMOVED
POWER MIG® 180 DUAL
B-4
OPERATION
TABLE B.1
DRIVE ROLL AND WIRE GUIDES
B-4
Wire Diameter &
Drive Roll
Type
.025”(0.6mm) MIG wire
.025”/.030” (0.6mm/0.8mm)
Smooth Drive Roll
.030”(0.8mm) MIG wire
.035”(0.9mm) MIG wire
.030”(0.8mm) flux-cored
.035”(0.9mm) flux-cored
.045”(1.1mm) flux-cored
.035”(0.9mm) Smooth Drive Roll
.030”/.045” (0.8mm/1.1mm)
Knurled Drive Roll
.030”/.045” (0.8mm/1.1mm)
Knurled Drive Roll
(See Figure B.6 for the following Items.)
12. CIRCUIT BREAKER – If the rated input current of
the machine is exceeded this circuit breaker will
trip. Press to reset.
13. GAS INLET – Shielding gas connects to this inlet.
14. POWER CORD CONNECTION - Ensure power
cord is diconnected from input voltage supply prior
to connecting or removing the cord from the
machine. Connect the circular connector present
on either input cord (120V or 230V) to the receptacle on the back of the machine. The power cord
connector is secured to the receptacle by rotating
the connectorʼs coupling ring clockwise, until the
coupling ring latches on to the receptacle. Use
only the appropriate (120V or 230V) power cords
supplied by the Lincoln Electric Company.
Drive Roll Part
Number
KP2529-1
KP2529-2
KP2529-3
KP2529-3
12
Inner Wire Guide
.025”-.035”
(0.6mm-0.9mm)
Steel Wire Guide
.045”(1.1mm)
Steel
Wire Guide
FIGURE B.6
13
14
Inner Wire Guide
Part Number
KP2531-1
KP2531-2
SETTING UP AND MAKING A FLUX-CORED WELD
A. ITEMS NEEDED FOR
FLUX CORED WELDING
1. 035”(0.9mm) Contact Tip
.035
2. .025”-.035”(0.6mm-0.9mm) wire
guide
INNER WIRE GUIDE
.025-.035 (.6-.9mm)
3. Knurled Drive Roll
4. .035”(0.9mm) NR-211MP FluxCored Wire
.035 NR-211MP
E
R
I
F
L
W
U
D
X
E
-
C
R
O
POWER MIG® 180 DUAL
5. Black Flux Cored gun nozzle
6. Welding Gun
7. Work Cable & Clamp
B-5
OPERATION
B-5
B. CONNECT LEADS AND CABLES ON
THE MACHINE
(See Figure B.7)
1. Open the case side door
2. Slide the connector end of the gun and cable
through the hole in the machine front and into the
gun connector bushing on the wire drive.
3. Make sure the gun connector end is seated fully
into the wire drive and tighten the thumbscrew to
secure the gun connector.
4. Plug the gun trigger lead connector into the 4 pin
gun trigger receptacle on the machine front.
5. Wire Drive Polarity. Flux cored welding requires
negative (-) polarity. Connect the short power
cable from the wire drive to the negative (-) output
terminal and tighten the Wing Nut.
6. Work Lead Connection. Slide the lugged end of
the work cable through the hole in the machine
front and place on the positive (+) output terminal
and tighten Wing Nut.
LOCATE COMPONENTS
TO CONNECT TO THE
FRONT OF MACHINE
SLIDE
CONNECTOR
END HERE
(4 PIN)
LEAD CONNECTOR
GUN AND CABLE
OPEN LATCH DOOR
TERMINAL END
(FITS ON STUD INSIDE
SEE FIGURE BELOW)
WORK CLAMP
THUMB SCREW TO
TIGHTEN CONNECTOR
BUSHING
CONNECTOR
END ATTACH
(4 PIN)
TRIGGER RECEPTACLE
PLUGGED IN
FIGURE B.7
CASE SIDE DOOR
ALL COMPONENTS SHOWN CONNECTED
(FRONT AND SIDE DOOR IS REMOVED
FOR CLARITY)
WORK CLAMP
SHORT POWER
CABLE NEGATIVE "-"
OUTPUT TERMINAL
WORK LEAD
CONNECTION
POSITIVE "+"
OUTPUT TERMINAL
OPERATORʼS MANUAL
C. LOAD WIRE SPOOL
(See Figure B.8)
1. Locate the 4"(102mm) diameter spool of
.035”(0.9mm) NR-211MP flux-cored wire and
place onto wire spool spindle. Orient the spool so
that the wire feeds off the top of the spool.
2. Secure spool in place by tightening the wing nut
against the against the spacer that holds the wire
spool on the spindle.
3. Open the top drive roll pressure arm by rotating
the tension adjustor arm down and pivoting the
drive roll pressure arm up.
4. Remove the outer wire guide.
4a. Slide gun out of drive slightly.
5. Remove the lower drive roll and inner wire guide.
6.
Install the .025”-.035”(0.6mm-0.9mm) inner wire guide.
7. Install the .030”/.045”(0.8mm/1.1mm) knurled lower drive
roll.
FIGURE B.8
TOP DRIVE ROLL PRESSURE ARM
TENSION ADJUSTOR DOWN
INNER WIRE GUIDE REMOVED
LOWER DRIVE ROLL REMOVED
WIRE SPOOL
.035" (0.9mm)
NR-211-MP
OUTER WIRE
GUIDE REMOVED
8. Carefully unwind and straighten the first six inches of
welding wire from the spool. Do not let the end of the
wire go to prevent the wire from unspooling.
POWER MIG® 180 DUAL
B-6
OPERATION
B-6
(See Figure B.9)
9. Feed the wire through the wire drive inlet along the
inner wire guide groove and into the wire drive outlet
on the gun side.
10. Close the top drive roll pressure arm and secure by
pivoting the tension adjustor back to the up position.
11. Re-install the outer wire guide.
(See Figure B.10)
12. Remove the nozzle from the gun and contact tip
and straighten the gun out flat.
13. Turn the machine power to on and depress the gun
trigger to feed the wire through the gun liner until
the wire comes out of the threaded end of the gun
several inches. (See figure B.11)
14. When trigger is released spool of wire should not
unwind. Adjust wire spool brake accordingly.
WARNING
MOVING PARTS AND ELECTRICAL
CONTACT CAN CAUSE INJURY OR BE
FATAL.
•When the gun trigger is depressed drive
rolls, spool of wire and electrode are
ELECTRICALLY LIVE (HOT).
• Keep away from moving parts and
pinch points.
• Keep all Doors, Covers, panels and
guards securely in place.
DO NOT REMOVE OR CONCEAL WARNING LABELS.
FEED WIRE
APPROXIMATELY 4.00"
FROM THE GUN TUBE END
DEPRESS TRIGGER
TO ACTIVATE WIRE,
WHICH FEEDS THE WIRE
THRU THE LINER.
TOP DRIVE ROLL
PRESSED AGAINST
LOWER DRIVE ROLL
FIGURE B.10
FIGURE B.11
ON/OFF
SWITCH
FIGURE B.9
TENSION ADJUSTOR
LOCKED IN POSITION
LOWER DRIVE ROLL
BE SURE WIRE
IS IN GROOVE
WIRE SPOOL
.035" (0.9mm)
NR-211-MP
.035"(0.9mm)
NR-211-MP
WIRE SPOOL
DIRECTION
OF WIRE
.035"(0.9mm)
NR-211-MP
WIRE SPOOL
PLUG IN POWER
INPUT CORD
ROTAT ION
6. Install the black flux cored welding nozzle to the
1
gun.
17. Trim the wire stickout to 3/8”(9.5mm) from the contact tip. (See Figure B.12)
18. Close the case side door. The machine is now
ready to weld.
19. Read "Learn to Weld" (LTW1) that is included with
the machine or watch the "How to Weld" DVD
included with the machine.
20. Based on the thickness of the material you are
going to weld and the type and diameter of the
welding wire set the voltage and the wire feed
speed per the procedure decal attached to the
inside of the wire drive compartment door.
POWER MIG® 180 DUAL
TRIM WIRE
STICKOUT
3/8"(9.5mm)
from the Contact Tip
WORK CLAMP AND CABLE
FIGURE B.12
INSTALL .035 CONTACT TIP
INSTALL BLACK FLUX-CORED NOZZLE
B-7
OPERATION
SETTING UP AND MAKING A MIG WELD
B-7
A. ITEMS NEEDED FOR MIG WELDING
1. 025”(0.6mm) Contact Tip
.025
2. 025”-035”(0.6mm-0.9mm) Inner wire guide
INNER WIRE GUIDE
.025-.035
.025-.035
3. .025”(0.6mm) Drive Roll
6. Welding Gun
7. Work Cable & Clamp
OPERATORʼS MANUAL
8. Gas Regulator & Gas Line
.025
4. .025”(0.6mm) SuperArc L-56 Solid MIG Wire
L-56 MIG
WIRE
5. Brass gun nozzle
9. Bottle of 75/25 Ar/
CO2shielding gas (or 100%
shielding gas) (note this requires a
adapter which is sold separately.
MALE END
CO
2
100%
(REQUIRES ADAPTER
SOLD SEPARATELY)
FEMALE END
CO2regulator
75/25
MIXES
CO
2
POWER MIG® 180 DUAL
B-8
B. INSTALL SHIELDING GAS
OPERATION
B-8
FIGURE B.13
MIG welding requires an appropriate bottle of shielding
gas. For mild steel either a cylinder bottle of Ar/CO
or
2
100% CO2can be used. Refer to the following instruc-
tions to properly connect shielding gas to the machine.
WARNING
CYLINDER may explode if damaged. Keep cylinder upright and
chained to support
• Keep cylinder away from areas
where it may be damaged.
• Never lift welder with cylinder
attached.
• Never allow welding electrode to
touch cylinder.
• Keep cylinder away from welding
or other live electrical circuits.
1. Secure the cylinder to a wall or other stationary
support to prevent the cylinder from falling
over. Insulate the cylinder from the work circuit
and earth ground. Refer to Figure B.13.
2. With the cylinder securely installed, remove the
cylinder cap. Stand to one side away from the
outlet and open the cylinder valve very slightly
for an instant. This blows away any dust or dirt
which may have accumulated in the valve outlet.
MALE END
CO
100%
FEMALE END
75/25
MIXES
2
REGULATOR
ADAPTER
PLASTIC
WASHER
S19298
3. Attach the flow regulator to the cylinder valve and
tighten the union nut securely with a wrench.
NOTE: If connecting to 100%
CO2cylinder, a
CO
2
regulator adapter is required. Purchase separately
S19298
CO2adapter be sure to install plastic washer
included in the fitting on the bottle side.(See Figure
B.13 )
4. Refer to Figure B.13. Attach one end of inlet gas hose
to the outlet fitting of the flow regulator and tighten the
union nut securely with a wrench. Connect the other
end to the machine Solenoid Inlet Fitting (5/8-18
female threads — for CGA — 032 fitting). Make certain the gas hose is not kinked or twisted.
SHIELDING GAS
1. For
2. Set gas flow rate for 30 to 40 cubic feet per hour (14
3. Keep the cylinder valve closed, except when using
CO2, open the cylinder very slowly. For argonmixed gas, open cylinder valve slowly a fraction of a
turn. When the cylinder pressure gauge pointer stops
moving, open the valve fully.
to 18 I/min.) under normal conditions, increase to as
high as 40 to 50 CFH (18 to 23.5 I/min.) for out of
postion welding.
the machine.
WARNING
BE SURE TO KEEP YOUR FACE AWAY FROM
THE VALVE OUTLET WHEN “CRACKING” THE
VALVE. Never stand directly in front of or behind
the flow regulator when opening the cylinder
valve. Always stand to one side.
2. Slide the connector end of the gun and cable
through the hole of the machine front and into the
gun connector bushing on the wire drive.
3. Make sure the gun connector end is seated fully
into the wire drive and tighten the thumbscrew to
secure the gun.
4. Plug the gun trigger lead connector into the 4 pin
gun trigger receptacle on the machine front.
5. Wire Drive Polarity. MIG welding requires Positive
(+) polarity. Connect the short power cable from
the wire drive to the positive (+) output terminal and
tighten the thumbscrew.
LOCATE COMPONENTS
TO CONNECT TO THE
FRONT OF MACHINE
SLIDE
CONNECTOR
END HERE
(4 PIN)
LEAD CONNECTOR
GUN AND CABLE
FIGURE B.14
OPEN LATCH DOOR
TERMINAL END
(FITS ON STUD INSIDE
SEE FIGURE BELOW)
WORK CLAMP
THUMB SCREW TO
TIGHTEN CONNECTOR
BUSHING
CASE SIDE DOOR
ALL COMPONENTS SHOWN CONNECTED
(FRONT AND SIDE DOOR IS REMOVED
FOR CLARITY)
WORK LEAD
CONNECTION
NEGATIVE "-"
OUTPUT TERMINA
B-9
OPERATORʼS MANUAL
6. Work Lead Connection. Slide the lugged end of the
work cable through the hole in the machine front
and place on the negative (-) output terminal and
tighten thumbscrew.
D. LOAD WIRE SPOOL
(See Figure B.15)
1. Locate the 4"(102mm) diameter spool of
.025”(0.6mm) L-56 solid MIG wire and place onto
wire spool spindle. Orient the spool so that the wire
feeds off the top of the spool.
2. Secure spool in place by tightening the wing nut
against the against the spacer that holds the wire
spool on the spindle.
3. Open the top drive roll pressure arm by rotating the
tension adjustor arm down and pivoting the idle roll
pressure arm up.
4. Remove the outer wire guide.
CONNECTOR
END ATTACH
(4 PIN)
TRIGGER RECEPTACLE
PLUGGED IN
FIGURE B.15
TOP DRIVE ROLL PRESSURE ARM
TENSION ADJUSTOR DOWN
WORK CLAMP
WIRE SPOOL
.025" (0.6mm)
L
-
5
SHORT POWER
CABLE POSITIVE "+"
OUTPUT TERMINAL
G
I
M
6
D
S
I
L
O
4a. Slide gun out of drive slightly.
5. Remove the lower drive roll and inner wire guide.
6. Install the .025”-.035”(0.6mm-0.9mm) inner wire guide.
7. Install the .025”(0.6mm) smooth grooved lower drive roll.
8. Carefully unwind and straighten the first six inches
of welding wire from the spool. Do not let the end
of the wire go to prevent the wire from unspooling.
POWER MIG® 180 DUAL
INNER WIRE GUIDE REMOVED
LOWER DRIVE ROLL REMOVED
OUTER WIRE
GUIDE REMOVED
B-10
OPERATION
(See Figure B.16)
9. Feed the wire through the wire drive inlet along the
inner wire guide groove and into the wire drive outlet on the gun side.
TOP IDLER ROLL
PRESSED AGAINST
LOWER DRIVE ROLL
FIGURE B.16
TENSION ADJUSTOR
LOCKED IN POSITION
B-10
10. Close the top drive roll pressure arm and secure
by pivoting the tension adjustor back to the up
position.
SLIDE WIRE
INTO GUN
CONNECTOR
SIDE
11. Re-install the outer wire guide.
(See Figure B.17)
12. Remove the nozzle from the gun and contact tip
and straighten the gun out flat.
13. Turn the machine power to on and depress the
gun trigger to feed the wire through the gun liner
until the wire comes out of the threaded end of the
gun several inches. (See Figure B.18)
14. When trigger is released spool of wire should not
unwind. Adjust wire spool brake accordingly.
WARNING
MOVING PARTS AND ELECTRICAL
CONTACT CAN CAUSE INJURY OR
BE FATAL.
•When the gun trigger is depressed
drive rolls, spool of wire and electrode are ELECTRICALLY LIVE (HOT).
• Keep away from moving parts and
pinch points.
• Keep all Doors, Covers, panels and
guards securely in place.
16. Install the brass gas MIG welding nozzle to the gun.
17. Trim the wire stickout to 3/8”(9.5mm) from the nozzle
end. (See Figure B.19)
REMOVED NOZZLE
REMOVED CONTACT TIP
LAY CABLE AND GUN STRAIGHTEN
IN THIS POSITION
FEED WIRE
APPROXIMATELY 4.00"
FROM THE GUN TUBE END
DEPRESS TRIGGER
TO ACTIVATE WIRE,
WHICH FEEDS THE WIRE
THRU THE LINER.
FIGURE B.17
FIGURE B.18
ON/OFF
SWITCH
WORK CLAMP AND CABLE
DRIVE ROLL
BE SURE WIRE
IS IN GROOVE
WIRE SPOOL
.025" (0.6mm)
L
-
5
6
S
O
L
WIRE SPOOL
.025" (0.6mm)
L
-
DIRECTION
OF WIRE
G
I
M
I
D
WIRE SPOOL
.025" (0.6mm)
L
G
-
I
5
6
M
S
O
D
L
I
PLUG IN POWER
INPUT CORD
G
I
5
6
M
S
O
D
L
I
ROTATION
18. Close the case side door. The machine is now ready
to weld.
19. Read "Learn to Weld" (LTW1) that is included with
the machine or watch the "How to Weld" DVD included with the machine.
20. Based on the thickness of the material you are going
to weld and the type and diameter of the welding
wire set the voltage and the wire feed speed per the
procedure decal attached to the inside of the wire
drive compartment door.
POWER MIG® 180 DUAL
TRIM WIRE
STICKOUT
3/8"(9.5mm)
from the Brass Nozzle
FIGURE B.19
INSTALL .025 CONTACT TIP
INSTALL BRASS NOZZLE
B-11
OPERATION
SETTING UP AND MAKING A ALUMINUM WELD USING SPOOL GUN
1. Disconnect Magnum 100L Gun.
2. Install optional K2532-1 Magnum 100SG spool gun
per instructions included with gun.
3. Set Gun selector toggle switch to Spool Gun position. (See Figure B.20)
4. Connect a bottle of 100% Argon shielding Gas per
previous section.
5. Follow the MIG welding steps in the previous section.
FIGURE B.20
B-11
OPERATORʼS MANUAL
WARNING
6. Turn machine on and make weld per recommended
settings on Procedure Decal inside machine door.
POWER MIG® 180 DUAL
C-1
K2525-1 - Spot Timer Kit
Timer kit, when turned on, allows you to set a fixed
weld time so that when the gun trigger is pulled the
machine will weld for a fixed time period up to 10 seconds. Ideal for making consistent spot welds when
welding on thin sheet metal.
K2528-1 - 045 Innershield Kit (For 230V models)
Includes everything needed to weld with .045 diameter Innershield wire. Includes an .035/.045
Magnum™ 100L gun liner, .045 Contact Tip, gasless
nozzle, knurled drive roll, .035-.045 inner wire guide,
and a 10 lb. (4.5kg) spool of .045"(0.9mm)
Innershield® NR®-212 wire.
K2532-1 - Magnum 100SG Spool Gun
Designed to easily feed small 4" diameter (1lb. spools
of) .030 or .035 aluminum wire. Includes gun, adapter
kit, three extra .035 contact tips, gas nozzle, and
spool of Superglaze 4043 .035" diameter welding
wire. Packaged in a convenient carry case.
ACCESSORIES
C-1
K2377-1 - Small Canvas Cover
Protect your machine when not in use. Made from
attractive red canvas that is flame retardant, mildew
resistant and water repellent. Includes a convenient
side pocket to hold welding gun.
For additional Optional and Miscellaneous Parts
(See Parts Pages)
POWER MIG® 180 DUAL
C-2
ACCESSORIES
K520—Utility Cart
Heavy duty cart stores and transports welder, 150
cubic foot shielding gas cylinder, welding cables and
accessories. Includes stable platforms for welder and
gas bottle platform, lower tray for added storage
capacity and adjustable height handle.
For mounting welding machines to K520 carts that do not have slotted mounting holes.
Drill 9/32” holes (3 places) into the cart top as shown and attach the welding machine to the
cart with the proper hardware shown.
C-2
1/4"-20 X 1/2" Hex Head Cap Screw
(2 Required)
OPERATORʼS MANUAL
1/4"-20 X 1"
Thread Forming Screw
(1 Required)
8-1/16"
3-11/16"
3-3/4"
9/32" DRILL
3 PLACES
1/4"-20
Flange Nut
(2 Required)
3-13/32"
4"
16"
POWER MIG® 180 DUAL
C-3
ACCESSORIES
K2275-1 - Welding Cart
Lightweight cart stores and transports welder, 80
cubic foot shielding gas cylinder, welding cables and
accessories. Includes an angled top shelf for easy
access to controls, lower tray for added storage
capacity, a sturdy fixed handle and convenient cable
wrap hanger.
For mounting welding machines to K2275-1 carts that do not have slotted mounting holes.
Drill 9/32” holes (3 places) into the cart top as shown and attach the welding machine to the
cart with the proper hardware shown.
C-3
1/4"-20 X 1/2" Hex Head Cap Screw
(2 Required)
1/4"-20 X 1"
Thread Forming Screw
(1 Required)
1/4"-20 Flange Nut
(2 Required)
7-9/16"
3-3/16"
1-1/4"
9/32" DRILL
3 PLACES
2-15/16"
1-1/2"
13-1/2"
POWER MIG® 180 DUAL
D-1
MAINTENANCE
D-1
MAINTENANCE
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Disconnect input power by removing plug from receptacle before
working inside POWER MIG® 180
DUAL.
Use only grounded receptacle. Do not touch electrically “hot” parts inside POWER MIG® 180
DUAL.
• Have qualified personnel do the maintenance
and trouble shooting work.
No user serviceable parts inside! Do not attempt to
perform service in the power source (fixed) side of the
POWER MIG® 180 DUAL. Take the unit to an authorized Lincoln Service Center if you experience problems. NO maintenance is required.
In extremely dusty locations, dirt may clog the air passages causing the welder to run hot with premature
tripping of thermal protection. If so, blow dirt out of the
welder with low pressure air at regular intervals to
eliminate excessive dirt and dust build-up on internal
parts.
GUN AND CABLE MAINTENANCE
FOR MAGNUM™ 100L GUN
Gun Cable Cleaning
Clean cable liner after using approximately 300 lbs
(136 kg) of solid wire or 50 lbs (23 kg) of flux-cored
wire. Remove the cable from the wire feeder and lay it
out straight on the floor. Remove the contact tip from
the gun. Using low pressure air, gently blow out the
cable liner from the gas diffuser end.
CAUTION
Excessive pressure at the start may cause the dirt
to form a plug.
Flex the cable over its entire length and again blow
out the cable. Repeat this procedure until no further
dirt comes out.
Contact Tips, Nozzles, and Gun Tubes
1. Dirt can accumulate in the contact tip hole and
restrict wire feeding. After each spool of wire is
used, remove the contact tip and clean it by pushing a short piece of wire through the tip repeatedly.
Use the wire as a reamer to remove dirt that may
be adhering to the wall of the hole through the tip.
2. Replace worn contact tips as required. A variable
or “hunting” arc is a typical symptom of a worn contact tip. To install a new tip, choose the correct size
contact tip for the electrode being used (wire size is
stenciled on the side of the contact tip) and screw it
snugly into the gas diffuser.
3. Remove spatter from inside of gas nozzle and from
tip after each 10 minutes of arc time or as required.
OPERATORʼS MANUAL
WIRE FEED COMPARTMENT
1. When necessary, vacuum accumulated dirt from
gearbox and wire feed section.
2. Occasionally inspect the incoming guide tube and
clean inside diameter if necessary.
3. Motor and gearbox have lifetime lubrication and
require no maintenance.
FAN MOTOR
Has lifetime lubrication — requires no maintenance.
WIRE REEL SPINDLE
Requires no maintenance. Do not lubricate shaft.
POWER MIG® 180 DUAL
4. Be sure the gas nozzle is fully screwed onto the
diffuser for gas shielded processes. For the
Innershield®process, the gasless nozzle should
screw onto the diffuser.
5. To remove gun tube from gun, remove gas nozzle
or gasless nozzle and remove diffuser from gun
tube. Remove both collars from each end of the
gun handle and separate the handle halves.
Loosen the locking nut holding the gun tube in
place against the gun end cable connector.
Unscrew gun tube from cable connector. To install
gun tube, screw the locking nut on the gun tube as
far as possible. Then screw the gun tube into the
cable connector until it bottoms. Then unscrew (no
more than one turn) the gun tube until its axis is
perpendicular to the flat sides of the cable connector and pointed in the direction of the trigger.
Tighten the locking nut so as to maintain the proper
relationship between the gun tube and the cable
connector. Replace the gun handle, trigger and diffuser. Replace the gas nozzle or gasless nozzle.
D-2
MAINTENANCE
OVERLOAD PROTECTION
Output Overload
The POWER MIG® 180 DUAL is equipped with a circuit breaker and a thermostat which protects the
machine from damage if maximum output is exceeded. The circuit breaker button will extend out when
tripped. The circuit breaker must be manually reset.
Thermal Protection
The POWER MIG® 180 DUAL has a rated output duty
cycle as defined in the Technical Specification page. If
the duty cycle is exceeded, a thermal protector will
shut off the output until the machine cools to a reasonable operating temperature. This is an automatic function of the POWER MIG® 180 DUAL and does not
require user intervention. The fan continues to run
during cooling.
Electronic Wire Drive Motor Protection
The POWER MIG® 180 DUAL has built-in protection for
wire drive motor overload.
Set ScrewBrass Cable
Connector
Liner Assembly
(Liner bushing to be sealed tight
against brass cable connector)
FIGURE D.2
Liner trim length
D-2
1-1/4”(31.8 mm)
Liner Trim Length
Gas Diffuser
Gas Nozzle or
Gasless Nozzle
CHANGING LINER
NOTICE: The variation in cable lengths prevents the
interchangeability of liners. Once a liner has been cut
for a particular gun, it should not be installed in another gun unless it can meet the liner cutoff length
requirement. Refer to Figure D.2.
1. Remove the gas nozzle from the gun by unscrewing counter-clockwise.
2. Remove the existing contact tip from the gun by
unscrewing counter-clockwise.
3. Remove the gas diffuser from the gun tube by
unscrewing counter-clockwise.
4. Lay the gun and cable out straight on a flat surface.
Loosen the set screw located in the brass connector at the wire feeder end of the cable. Pull the liner
out of the cable.
5. Insert a new untrimmed liner into the connector end
of the cable. Be sure the liner bushing is stenciled
appropriately for the wire size being used.
6. Fully seat the liner bushing into the connector.
Tighten the set screw on the brass cable connector.
At this time, the gas diffuser should not be installed
onto the end of the gun tube.
8. Screw the gas diffuser onto the end of the gun tube
and securely tighten.
9. Replace the contact tip and nozzle.
GUN HANDLE PARTS
The gun handle consists of two halves that are held
together with a collar on each end. To open up the
handle, turn the collars approximately 60 degrees
counter-clockwise until the collar reaches a stop. Then
pull the collar off the gun handle. If the collars are difficult to turn, position the gun handle against a corner,
place a screwdriver against the tab on the collar and
give the screwdriver a sharp blow to turn the collar
past an internal locking rib. See Figure D.3.
¢
Counter-clockwise
7. With the gas nozzle and diffuser removed from the
gun tube, be sure the cable is straight, and then
trim the liner to the length shown in the Figure D.2.
Remove any burrs from the end of the liner.
POWER MIG® 180 DUAL
FIGURE D.3
E-1
TROUBLESHOOTING
HOW TO USE TROUBLESHOOTING GUIDE
WARNING
Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician and
machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical
Shock, please observe all safety notes and precautions detailed throughout this manual.
This Troubleshooting Guide is provided to help you
locate and repair possible machine malfunctions.
Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled “PROBLEM (SYMPTOMS)”. This column describes possible symptoms
that the machine may exhibit. Find the listing that
best describes the symptom that the machine is
exhibiting.
Step 2. POSSIBLE CAUSE.
The second column labeled “POSSIBLE CAUSE” lists
the obvious external possibilities that may contribute
to the machine symptom.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the
Possible Cause, generally it states to contact your
local Lincoln Authorized Field Service Facility.
If you do not understand or are unable to perform the
Recommended Course of Action safely, contact your
local Lincoln Authorized Field Service Facility.
OPERATORʼS MANUAL
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER MIG® 180 DUAL
E-2
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-2
PROBLEMS
(SYMPTOMS)
Major physical or electrical damage
is evident.
No wire feed, weld output or gas
flow when gun trigger is pulled. Fan
does NOT operate.
No wire feed, weld output or gas
flow when gun trigger is pulled.
Fan operates normally.
POSSIBLE
CAUSE
OUTPUT PROBLEMS
“Do not Plug in machine or turn it on”.
Contact your local Authorized Field
Service Facility.
1. Make sure correct voltage is
applied to the machine.
2. Make certain that power switch
is in the ON position.
3. Make sure circuit breaker is
reset.
1. The thermostat may be tripped
due to overheating. Let machine
cool. Weld at lower duty cycle.
2. Check for obstructions in air
flow. Check Gun Trigger connections. See Installation section.
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service
Facility.
PROBLEMS
(SYMPTOMS)
No wire feed when gun trigger is
pulled. Fan runs, gas flows and
machine has correct open circuit
voltage (33V) – weld output.
3. Gun trigger may be faulty.
POSSIBLE
CAUSE
FEEDING PROBLEMS
1. If the wire drive motor is running
make sure that the correct drive
rolls are installed in the machine.
2. Check for clogged cable liner or
contact tip.
3. Check for proper size cable liner
and contact tip.
4. Check if the spool gun switch,
located in the wire drive compartment, is set to the desired location.
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service
Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER MIG® 180 DUAL
E-3
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-3
PROBLEMS
(SYMPTOMS)
Low or no gas flow when gun
trigger is pulled. Wire feed, weld
output and fan operate normally.
PROBLEMS
(SYMPTOMS)
Arc is unstable – Poor starting.
POSSIBLE
CAUSE
GAS FLOW PROBLEMS
1. Check gas supply, flow regulator
and gas hoses.
2. Check gun connection to
machine for obstruction or leaky
seals.
POSSIBLE
CAUSE
WELDING PROBLEMS
1. Check for correct input voltage
to machine.
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service
Facility.
OPERATORʼS MANUAL
RECOMMENDED
COURSE OF ACTION
2. Check for proper electrode
polarity for process.
3. Check gun tip for wear or damage and proper size – Replace.
4. Check for proper gas and flow
rate for process. (For MIG only.)
5. Check work cable for loose or
faulty connections.
6. Check gun for damage or
breaks.
7. Check for proper drive roll orientation and alignment.
8. Check liner for proper size.
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service
Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER MIG® 180 DUAL
F-1
DIAGRAMS
F-1
WARNING
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The
specific diagram for a particular code is pasted inside the machine on one of the enclosure panels.
POWER MIG® 180 DUAL
Loading...
+ 64 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.