Lincoln Electric IM980 User Manual [en, de, es, fr]

Page 1
IM980
RETURN TO MAIN MENU
RED-D-ARC
EX350ie (CE)
For use with machines having Code Numbers:
11526
November, 2008
(
OPERATOR’S MANUAL
Red-D-Arc Spec-Built Welding Equipment
This
RED-D-ARC
design specifications by Lincoln Electric.
Safety Depends on You
This welder is designed and built with safety in mind.
However, your overall safety can be increased by proper installation
... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
North America’s Largest Fleet of Welding Equipment
welder is built to
Page 2
i
SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause can­cer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
i
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
____________________________________________________
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in
position tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety guards guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.
___________________________________________________
1.b. Operate engines in open, well-ventilated areas
or vent the engine exhaust fumes
outdoors.
1.c. Do not add the fuel near an open flame welding
arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz­ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
and in good repair.Keep hands, hair, clothing and
to perform required maintenance. Remove
1.f. Do not put your hands near the engine fan. Do
not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND MAGNETIC FIELDS may be dangerous
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning
the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
EX350ie (CE) (RED-D-ARC)
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Mar ʻ95
Page 3
ii
SAFETY
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
skin or wet clothing. Wear dry, hole-free
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough
fumes and gases away from the breathing zone. When
welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
5. b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the spe­cific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors form phosgene, a highly toxic gas, and other irritating prod­ucts.
ventilation and/or exhaust at the arc to keep
vapors
to
3.j. Also see Items 6.c. and 8.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturerʼs instructions for this
equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employerʼs safety practices. MSDS forms are available from your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
AUG 06
EX350ie (CE) (RED-D-ARC)
Page 4
iii
SAFETY
iii
WELDING and CUTTING SPARKS can cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even been “cleaned”. For information, purchase “Recommended Safe Practices for the Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f. free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate cir­cuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
the welding sparks from starting a fire.
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode if damaged.
7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturerʼs recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batterymarch Park,PO box 9101, Quincy, Ma 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
EX350ie (CE) (RED-D-ARC)
Jan, 07
Page 5
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instruc­tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes:
Sûreté Pour Soudage A LʼArc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à lʼélectrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien sʼisoler de la masse quand on
soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état defonctionnement.
d.Ne jamais plonger le porte-électrode dans lʼeau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à soud­er parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions pour le porte-électrode sʼapplicuent aussi au pistolet de soudage.
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les zones où lʼon pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque dʼincendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de la masse. Un court-circuit accidental peut provoquer un échauffement et un risque dʼincendie.
8. Sʼassurer que la masse est connectée le plus prés possible de la zone de travail quʼil est pratique de le faire. Si on place la masse sur la charpente de la construction ou dʼautres endroits éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de lev­age, câbles de grue, ou autres circuits. Cela peut provoquer des risques dʼincendie ou dʼechauffement des chaines et des câbles jusquʼà ce quʼils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage. Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant dʼopérations de dégraissage, nettoyage ou pistolage. La chaleur ou les rayons de lʼarc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas forte­ment toxique) ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA Standard W 117.2-1974.
2. Dans le cas de travail au dessus du niveau du sol, se pro­téger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de nʼimporte quelle partie du corps.
3. Un coup dʼarc peut être plus sévère quʼun coup de soliel, donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi quʼun verre blanc afin de se protéger les yeux du rayonnement de lʼarc et des projections quand on soude ou quand on regarde lʼarc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de lʻarc.
c. Protéger lʼautre personnel travaillant à proximité au
soudage à lʼaide dʼécrans appropriés et non-inflamma­bles.
4. Des gouttes de laitier en fusion sont émises de lʼarc de soudage. Se protéger avec des vêtements de protection libres de lʼhuile, tels que les gants en cuir, chemise épaisse, pantalons sans revers, et chaussures montantes.
EX350ie (CE) (RED-D-ARC)
PRÉCAUTIONS DE SÛRETÉ POUR LES MACHINES À SOUDER À TRANSFORMATEUR ET À REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de lʼélectricité et aux recommendations du fabricant. Le dis­positif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, Iʼinstallation et lʼentretien du poste seront effectués par un électricien qualifié.
3. Avant de faires des travaux à lʼinterieur de poste, la debrancher à lʼinterrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
Mar. ʻ93
Page 6
v
SAFETY
Electromagnetic Compatibility (EMC)
Conformance Products displaying the CE mark are in conformity with European Community Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (89/336/EEC). It was manufactured in conformity with a national standard that implements a harmonized standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment. It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.
Introduction All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions are received by other equipment, electrical interference may result. Electrical emissions may affect many kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions may be required when a welding power source is used in a domestic establishment.
Installation and Use The user is responsible for installing and using the welding equipment according to the manufacturerʼs instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it could involve construction of an electromagnetic screen enclosing the power source and the work complete with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where they are no longer troublesome.
v
Note: The welding circuit may or may not be earthed for safety reasons according to national codes.
Changing the earthing arrangements should only be authorized by a person who is compe­tent to access whether the changes will increase the risk of injury, e.g., by allowing parallel welding current return paths which may damage the earth circuits of other equipment.
Assessment of Area Before installing welding equipment the user shall make an assessment of potential electromagnetic prob­lems in the surrounding area. The following shall be taken into account:
a) other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the
welding equipment;
b) radio and television transmitters and receivers;
c) computer and other control equipment;
d) safety critical equipment, e.g., guarding of industrial equipment;
e) the health of the people around, e.g., the use of pacemakers and hearing aids;
f) equipment used for calibration or measurement
g) the immunity of other equipment in the environment. The user shall ensure that other equipment being
used in the environment is compatible. This may require additional protection measures;
h) the time of day that welding or other activities are to be carried out.
EX350ie (CE) (RED-D-ARC)
L10093 3-1-96H
Page 7
vi
SAFETY
Electromagnetic Compatibility (EMC)
The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises.
Methods of Reducing Emissions
Mains Supply Welding equipment should be connected to the mains supply according to the manufacturerʼs recommenda­tions. If interference occurs, it may be necessary to take additional precautions such as filtering of the mains supply. Consideration should be given to shielding the supply cable of permanently installed welding equip­ment, in metallic conduit or equivalent. Shielding should be electrically continuous throughout its length. The shielding should be connected to the welding power source so that good electrical contact is maintained between the conduit and the welding power source enclosure.
Maintenance of the Welding Equipment The welding equipment should be routinely maintained according to the manufacturerʼs recommendations. All access and service doors and covers should be closed and properly fastened when the welding equip­ment is in operation. The welding equipment should not be modified in any way except for those changes and adjustments covered in the manufacturers instructions. In particular, the spark gaps of arc striking and stabilizing devices should be adjusted and maintained according to the manufacturerʼs recommendations.
vi
Welding Cables The welding cables should be kept as short as possible and should be positioned close together, running at orclosetofloorlevel.
Equipotential Bonding Bonding of all metallic components in the welding installation and adjacent to it should be considered. However, metallic components bonded to the work piece will increase the risk that the operator could receive a shock by touching these metallic components and the electrode at the same time. The operator should be insulated from all such bonded metallic components.
Earthing of the Workpiece Where the workpiece is not bonded to earth for electrical safety, not connected to earth because of its size and position, e.g., ships hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to users, or damage to other electrical equipment. Where necessary, the connec­tion of the workpiece to earth should be made by a direct connection to the workpiece, but in some countries where direct connection is not permitted, the bonding should be achieved by suitable capacitance, selected according to national regulations.
Screening and Shielding Selective screening and shielding of other cables and equipment in the surrounding area may alleviate prob­lems of interference. Screening of the entire welding installation may be considered for special applications. 1
_________________________
1
Portions of the preceding text are contained in EN 60974-10: “Electromagnetic Compatibility (EMC) prod­uct standard for arc welding equipment.”
L10093 3-1-96H
EX350ie (CE) (RED-D-ARC)
Page 8
viivii
Thank You
for selecting one of our QUALITY products. We want you to take
CUSTOMER ASSISTANCE POLICY
The business of our company is manufacturing and selling high quality welding equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask us for advice or information about their use of our products. We respond to our customers based on the best informa­tion in our possession at that time. We are not in a position to warrant or guarantee such advice, and assume no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customerʼs particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such informa­tion or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.
We are a responsive manufacturer, but the selection and use of specific products sold by us is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond our control affect the results obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing.
pride in operating this product ••• as much pride as we have in bringing this product to you!
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code (if available)______________________________________________________
Serial Number (if available)__________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you have recorded above.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
Page 9
viii
TABLE OF CONTENTS
Page
Installation .......................................................................................................Section A
Technical Specifications ........................................................................................A-1
Safety Precautions ..........................................................................................A-2
Select Suitable Location..................................................................................A-2
Stacking ..........................................................................................................A-2
Tilting...............................................................................................................A-2
Input and Grounding Connections ..................................................................A-2
Power Cord Connection ..................................................................................A-2
Connection of Wire Feeders to EX350ie (CE) ................................................A-2
Remote Control of Invertec .............................................................................A-3
Undercarriage Mountings................................................................................A-3
Parallel Operations..........................................................................................A-4
________________________________________________________________________
Operation .........................................................................................................Section B
Additional Safety Precautions ...............................................................................B-1
General Description and Duty Cycle......................................................................B-1
Operational Features and Controls.........................................................B-1 Thru B-3
Remote Control of the Output Control and Weld Terminals ..................................B-3
Auxiliary Power......................................................................................................B-4
Limitations..............................................................................................................B-4
Recommended Processes ....................................................................................B-4
________________________________________________________________________
viii
Accessories.....................................................................................................Section C
General Options / Accessories..............................................................................C-1
“CE” Version ........................................................................................................................
C-1
Field Installed Options/Accessories.......................................................................C-1
Ouick Disconnect Plugs.........................................................................................C-1
________________________________________________________________________
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
C
APACITOR DISCHARGE PROCEDURE..........................................................................D-1
ISUAL INSPECTION...................................................................................................D-1
V R
OUTINE MAINTENANCE ............................................................................................D-1
ERIODIC MAINTENANCE ...........................................................................................D-1
P
________________________________________________________________________
Section E ..............................................................................................Troubleshooting
Safety Precautions.................................................................................................E-1
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide ...........................................................................E-2 Thru E-3
Fault Codes ...........................................................................................................E-4
Displays .................................................................................................................E-5
________________________________________________________________________
Connection , Wiring Diagrams and Dimension Prints .................................Section F
________________________________________________________________________
Parts List .....................................................................................................P-584 Series
________________________________________________________________________
Page 10
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS -
EX350ie (CE) (RED-D-ARC)
INPUT AT RATED OUTPUT
Product
Name
EX350ie
(CE)
50/60 Hz
Ordering
Informatiion
K1757-3
Input AC
Voltage
200-220/ 380-400/ 415-440/
Rated DC Output
Amps/Volts/Duty Cycle
50/0Hz
350A / 34V / 60%
3 Phase
320A / 38V/ 60%
1 Phase
275A /31V / 100%
1 Phase
300A / 32V / 100%
3 Phase
Output Range
(continuous)
AMPS
5-425
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Voltage
200 220 380 400 415 440
Phases
3 3 3 3 3 3
Input Amps
300Amps @
32Volts(100%)
41 37 28 22 22 21
Input Amps
350Amps @
34Volts(60%)
48 48 28 27 26 24
Recommended
Line Cord
AWG
6 6 8 8 8 8
Maximum Fuse size
80A 80A 50A 50A 50A 50A
Note 2
Note 2
Open
Circuit
80 VDC
Notes
Voltage
200
220 380 400 415 440
Note 1. Not rated is indicated by 4-xʼs in the box on the rating plate. Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
Phases
1
1 1 1 1 1
Input Amps
275 Amps @
31Volts(100%)
Not
Recommended
64 44 40 38 35
Input Amps
320 Amps @
33Volts(60%)
Not
Recommended
82 55 50 48 45
Recommended
Line Cord
AWG
---
4 6 8 8 8
Maximum Fuse size
---
125A
80A 80A 80A 80A
Notes
Note 1
Note 2
Note 2
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select the output cable size based upon the following chart. Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE CURRENT LENGTH UP 61m (200 FT) 61-76m (200-250 FT)
100% 275 1/0 1/0
60% 350 1/0 2/0
PHYSICAL DIMENSIONS
Height Width Depth
14.8”(373mm) 12.5”(317mm) 27.8” *(706mm*) 86.5 Lbs.(37.4 Kg)
Weight with Cord
TEMPERATURE RANGES
OPERATING TEMPERATURE RANGE
-20°C to +40°C
* Overall Length Including Handle, 27.8” (706mm)
STORAGE TEMPERATURE RANGE
-40°C to +40°C
EX350ie (CE) (RED-D-ARC)
Page 11
A-2
L o r e m ip su
m dol or s i
t a m et c o ns
ec t e t ue r ad
i p i s c i n g
e l it , e d di am
no n um my n
i bh eui s m
od ti nc i dunt
u t
l a o r e e t d o l o r e ma
gna al i qu
am e r a t
L o re m i p s
um dol or s i t a
met c o ns e
c tetu e r a di
p i s c i ng
e l it , e d di am
no nu mmy n
i b h eui s mo
d t i nc i du nt u
t
l a o r e e t d ol or e m
ag na a l i q u a
m e r at
L o r e m i p s
um dol o r s i t a
me t c on s e c te
tu er a di pi s
c i n g
e li t , e d di a m
non u mm y ni
bh eu i s m o d t
i nc i du nt u t
l a o r e e t d ol o r e ma
gna al i q ua
m e r at
L o r e m i p s
u m d ol or s
i t am e t c o n s
e c t et u e r a
di p i s c i ng
e l it , e d d i a m n
o n u mm
y n i b h e ui s mo
d t i nc i d unt u
t
l a o re e t d o l o r e m
ag na al i qua
m er at
L o r e m i p s
um do l o r s i t
a met c on s
ec te tu er a d i
p i s c i ng
e li t, e d di a m no
n u mm y ni
bh e ui s m
o d ti nc i d unt u
t
la o r e e t d ol or e m
a g n a a l i qua
m e r a t
L o r e m i p s
um d o l or s i t a
m et c ons e c te
t ue r adi pi
s c i n g
e l i t , e d di a m
n o num m y ni
bh e ui s mo d ti
nc i d u n t ut
l a o r e e t do l o r e m
agn a a l i q ua
m e r at
L o r e m i p s
um do l o r s
i t am et c o n s e
c t etue r a d i pi
s c i ng
e l it , e d di am
no nu m my
n i b h eui s m od t
i n c i d unt u
t
la o r e e t d ol or e m
ag na a l i
q ua m e r at
L o r e
m i p s um d o
l or s i t a m et c o ns e
c t etue r a d
i p i s c i n g
e l it , e d
di a m n onu
mm y n i bh eui s m od
t i n c i du n t
ut
la o r e e t d o
l o r e m ag n a
al i q u am e r at
L o r e m
i p s um d ol o r
s i t a me t c on
s ec tetue r a d i p i s c
i n g
e li t , e d di
am n on u mm
y ni bh e u i s
m od t i nc i dun t ut
l a
o r e e t do l or
e m a gna a
l i q ua m e r at
L o re m i p s
u m d o l or s i t am
et c o ns e c te tuer
a di pi s c i ng
e l it , e d di am
no nu mm y n i bh
eu i s m o d t i nc
i du nt u t
l a o re e t do l o r e m
agn a al i q uam e
r a t
L o re m ip s
u m d ol or s i t a m e
t c o ns ec t e t u er a
di pi s c i ng
e l it , e d d i am
n o num my n i b h e
u i s mo d t i n c i du nt
u t
l a o r e e t d o l o r e
m a gna al i qu a m e
r a t
L o r e m i p s
u m do l o r s i t a
m et c on s e c t e t u
e r adi p i s c i ng
e lit , e d d i am
n on um my n
i b h eui s m o d t i nc
i d unt u t
la o r e e t d ol o r e m
ag n a a l i q ua
m e r a t
L o r e m i p s
um d o l or s
i t am et c o ns
ec te tue r ad
i pi s c i n g
e l it , e d di a m
n onum m
y n i b h e ui s mo
d t i nc i d u n
t u t
l a o r e e t d ol o r e m
ag na a l i q
ua m er a t
L o re m ips
u m d o l o
r s i t a me
t c o n s e
c t e t u e r
a d i p i s c i n
g
e l it, e d d ia
m n o n u m
my n i b h
e u i s mo d
t i n c i d u
n t u t
l ao r ee t do lo r
e m a g n a
a l i q u a m
e r a t
L ore m i
ps u m d ol o
r s i t a m e t
c o n s e c
t e t u e r a d
i p i s c i n g
e lit, e d d ia
m n o n u mmy
n i b h e
u i s mo d
t i n c i d u n t
u t
la o re e t do lo r
e ma g n a
a l i q u a m e
r a t
L o re
m ip su m d o l
o r s i t a m e
t c o n s e c t e
t u e r a d i
p i s c i n g
e lit, e d d
iam n o n u m
my n i b h e
u i s mo d t
i n c i d u n t
u t
la or ee t d olor
e ma g n a
a l i q u a m e
r a t
Lo
re m ip su m do
l o r s i t a me
t c o n s e c t e
t u e r a d i p
i s c i n g
el it, e
d d i a m n o n
u mm y n i b h
e u i s mo d t
i n c i d u n t u
t
l a or ee
t d o lor e ma g n
a a l i q u a m e
r a t
L o r e m
i p s u m dol
or s i t a m e t c
o ns ec te tue
r a di pi s c i ng
e li t, e d di
am no nu
m m y ni bh e
ui s m od ti nc
i d u n t u t
la o r e e t d o l or
e m a g n a a
l i q uam e r
a t
L o r e m
ip s u m dol
o r s i t am e
t c on s e c t e tu
e r a di pi s c i
ng
e li t , e d
d i a m no nu m
m y ni b h e
ui s mo d t i nc
i d u nt ut
la o r e e t dol
or e ma gn a al
i qu am er
a t
INSTALLATION
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• TURN THE INPUT POWER OFF AT THE DISCONNECT SWITCH BEFORE ATTEMPTING TO CONNECT OR DIS-
CONNECT INPUT POWER LINES, OUTPUT CABLES, OR CONTROL CABLES.
• Only qualified personnel should perform this installation.
• Connect the green/yellow lead of the power cord to ground per appropriate National Electrical Code.
----------------------------------------------------------------------
SELECT SUITABLE LOCATION
The EX350ie (CE) will operate in harsh environments. Even so, it is important that simple preventative mea­sures are followed in order to assure long life and reli­able operation.
• The machine must be located where there is free cir­culation of clean air such that air movement in the back, out the sides and bottom will not be restricted.
• Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown.
• Keep machine dry. Shelter from rain and snow. Do
not place on wet ground or in puddles.
CAUTION
• DO NOT MOUNT OVER COMBUSTIBLE SURFACES.
Where there is a combustible surface directly under stationary or fixed electrical equipment, that surface shall be covered with a steel plate at least .06”(1.6mm) thick, which shall extend not less than 5.90”(150mm) beyond the equipment on all sides.
------------------------------------------------------------------------
STACKING
EX350ie (CE) cannot
TILTING
Place the machine directly on a secure, level surface or on a recommended undercarriage. The machine may topple over if this procedure is not followed.
INPUT AND GROUNDING CONNECTIONS
• Only a qualified electrician should connect the
EX350ie (CE). Installation should be made in accor­dance with the appropriate National Electrical Code, all local codes and the information detailed below.
• When received directly from the factory, multiple
voltage machines are internally connected for 440VAC. If 440VAC is the desired input, then the machine may be connected to the power system without any setup required inside the machine.
be stacked.
A-2
• Initial 200VAC - 415VAC operation will require an Input voltage panel setup.
• Open the access panel on the rear of the machine.
For 200 or 230: Position the large switch to 200-230. For higher voltages: Position the large switch to ≥ 380.
• Move the "A" lead to the appropriate terminal.
POWER CORD CONNECTION
A 5 meter power cord is wired into the machine. Follow the power cord connection instructions.
CAUTION
Incorrect connection may result in equipment damage.
------------------------------------------------------------------------
!
WA
!
RN
WA
Lo r em e l i t,
IN
l i a e
ps
or
R
d e
u d e
m i t
a L d
do
m or o e
e
l
n
l
N
o
G
or m
l
o
i
r
t
e
l
s
nu
, a
i
ed d
ps
i
o
m
t
m
am
r
a
e
um
my
gna
e
IN
i t
a
et
d
Lor
n
d
m n
c
al
o
ol
i
bh
el
l
o
o
e
or
i o
ns
qu r
m i
e
nu
s
l t,
eu
m
aor
e
a
i
i
ed
p
t mmy
c m
i
ame
s
s
te
agn
G
m
e
u
d
e tue
et d
m d
od r
i a
at
a
t c
ni
m
r
a
ti a
ol
ol
b
o
L
n
l
no
h
i
o
d
o
ns
quam
o
c
eui
r
i
r
i
r
pi e
nu
s
du e
el
ec
ma
s
m i
i
i
t
mm
s
l
c
nt
t,
ame
tetu mo
ao
i ng
er e
ps
gn
ut d d r
y
at
e
d
e
um
a
t
ni
r
e
c
ti
al
ad i t
a
bh eu
nc d
do
on
m
i q
!
i
o
i
pi
no
dun
s
ua
l
l
o
or
e
s
L
r
c
c
m
i
or
e
nu
s
s
te
i
t u
e
n
m
mod
em
i
e
t
g
tu
mm
l
t
r
i
am
agn l t
a
er , ed a
t
i
t ps or
y
a
ATT
et c
i
nc
n
a
di
e
u
d
a
i
e
m d
i
b
Lor
pi i
du
o
l t
am
h
i
ns
q
s
d
eu
n
c
ua
em
o
el
ol
!
no
i
ec
t u
n
l o
i
or
l
m
i
t,
g
s
r
i
t
aor
t
e
e
nu
m
s
e e
p
t
A
d
s
i
m
u
o
r
t m
e
u
at
er
d d
am a
e
m
my
i
gna
t t d
am
i
a nc
do
e
di
n
V
ol
t
n
i
al
p d
l
E
c
i
o
o
bh
i
onu
u
o
s
r
r
i
e m
s
nt u
ns
q
c
P
i u
e
n
i t
L
ec
m
am
u
g
I
a
or
ag
t
i
my
s
m
te
NTI
el
m
em
er
n
SO DE
et c
tue
n
o
a a
i
RE
l t
a
, e
d t
L
ao
i
i
t
bh
r
p
o
on
L
l
ad
i
d
i
s
r
r
q
n
o
em
e
e
u
di
s
u
c
e
l
e
m do
r
i
i
ec
i
am
l
u
p
t,
d
em
t
a
e
i
aor
d
i
i unt
s
s
m n
ed
p
t
l
e m
c
i
ol
e
s
t
tue
i
l
e
l
,
u
n
o
ut
o
a
or
r
d
i
o
et
at
m
g
d
r
e
p
i
o
e m
num
a
s
Lor
r
t
do
d
s
d
m
r
O
C
i
a
i
L
nc
t
e
u
o
am
d
n
d
em
e
ag
o
l
l
et
m
i
o
m
o i p
l
du
o
i
i
r
r
r
l
a
t
i
na
y
e m
n
e
s
e
,
et
a
s
i
d
n
m
d
n
c
umm
ed
ps
or
m
i
l
t
a
i t
i
o
o
c
n
i
t
A
b
am
N
ag
u
ee
l
um
o
,
g
l
l
n
a
l
d
h
i
t
o
i
o
ns
q
e
p
i
e
o
o
n
t d
y
a
ua
e
r
r
do
L
d
s
a a
m
ec
e
n
r
ui
t
ni
or
c
s
o
e
u
m e
n
u
s
b
d
te
l
l
i
m
o
e
UC
or
e
m
el
l
o
mo
t
h e
i
m
on
i
n
qua
m
r
tue
t
a
i
a
e
s
l
a
r
s
t,
at
my
i
ma
ao
d
d t
u
m
d
e ui
me
i
g
ed
p
t
r
mm
c
m
o
o
ad
s
s
n
am
r
i
t
n
etue
L
mo
ee
l
um d
n
er
di
l
g
a
o
o
c
o
t
n
na
y
o
i
i
et
pi
r
r
t do
r
a
e
d
at
c
i
d
a
e
e
n
n
b
m
u
s
r
ti
s
m
o
l
c
i
l
al
a
i
o
u
nt u
c
b
l
h i
t, e
n
o
i
ma
nc
n
q
l
i
i
l
aor
h e
t
i
o
mmy
n
o
di
n
q
ps
on
s
u
e
r
g
r
a
s
u
i p
d
e
s
t
d
ION
e
e
a
u
a
ui
e
um
m
i
um
g
u s
di
i
m
c
m
c
et d
t
m
i
s
n
c
n
a
te
s
am
e
t
agn
mo
i
t ng
m
e
e
m
a
d
me
tu
u
t n
e
r
o
ol
t
y
t
a
er
d ti
c
u
i
o
a
l
n
r
a a
b
or
t
o
t c
n
a
o
o
e
d
l
adi
L
r
i
h i
e m
nu
b
s
nc
t
n
q
or
r
o
l
h e
i
t
i
ns
e
qu
s
u
e
t am
i
e
a
i
m
p d
n
e
m
a
ag
l
u
i
d
e
i
u
am
my
ui
s
c
t
c
l , e
m
i
c
nt
c
a
i
s
i
s
i
na
p
te
p
t
i
et c
d
or
n
mo
ni
e
mo
d
s
u
i
e
g
t
u
e
a
s
ee
um d
ue
di
t
t
r
b
u
a
n
c
on
r
d l h
i
t
a
t
a
q
r
e
i
d
t
d
ti
a
n
m
s
u
e
Lo
t
r
nc
u
o
e
ol
am e
g
u
di
t
i
a
l
t
c
n
i
r
o
n
i
o
s
p
e
e
d
t
o
d
e
r
m
r
i
m
c
l
un
e m
s
nu
i
t
l
s
t, e
i
u
c
o
i
r
p
i
ao
i
d
at
i
t ut
t
e
d
mm
p
n
am
i
u
r
ti
ag
s
d
s
g
r
a
e um d
di
n
c
nc
e
n
d
y
et
i
t
n
t do
a
i
am
i
pi
n
du
u g
c
i
a
s
bh
ol
t
o
l
no
nt u
c
i
l
ns
qu or o
i ng
e
r e
n
s
e am e
u
t
u
c i
i
m
s
t a
mm
te m
agna
L
tu
m
od r
L
o
a
y
er
et
or
t
r
ni
t
a
e
e
a
em
el
i
c
n
bh
m
l
di
o
i
l
c
i
l t, e
i
t
ns
q
i
i
p
ao
l
du
e
, a
uam
ps
i
i
s
e
ec
p
u
d di
o
r
n
c
e
u
i
L
d
s
s
i
t
r
tet
ng
et
m
L
or
m
e
u
ut
a
e
d
el
d
o
e
em
ue
m
od
m
r
dol
i
at
r
ol
t
a
i
no
e
t
e
r
ti
l ,
i
o
d
a
a
m
or
d
e
m
l
p
nc
r
o
i
o
o
d
e
nu
s
t
d
s
r
l ,
i
m
ee
l
a
um
n
di
i
l
p
i
d
o
i
o
t a m
e
p
i
o
o
unt
s
r
agn
t
r
a
d
s
dol
m
d
c
e
r
n
me
m
s
i
e
u
n
y
ut
o
u
d
i
ma
e
g
a a
m
n
l
t
t
or
ni
m
o
i
on
t
a
c
r
a
b
e
o
my
l
d
s
m
d
h
i
m g
umm
ns
q
ma
i t
o
o
ua
e
n
am
e
ec
l
no
ui
l
a
o
o
g
t
m
n
s
na
te
y
r
r
et
c
m
i
a e
n
b
er n
tu
s
o
c
al
l
od
u
i
h
i
b
a
i
ma
e
n
q
o
t mmy
h e
t
i
r n
qu
s
u
e
t
a
a
i s
nc
e
a
u
me
di
e
g
a
u
c
m
i
c m e
i
i
p
n
s
s
du te
t
i
mo
e
a
m
s
t
n
tu
e
nt u
c
t
r
c
i
i
u
a
o
at
e
r
ng
d t
b
a
o
r
e
d
l
h
i
t
i
a
t
n
q
r
nc
d
t
s
u
e
i
a
i
n
i
pi
e
d
a
u
d c
un
s
c m
i
i
s
c
i p
t
d
i
t u
e mo
ng
i
u
e
s
t
t
u
n
c
r a
e d
i
t
n
t
r
u
g t i a
t n d c
i
i
p
d
i
u
s
n
c i
t n u g t
A
A M
P S
V
V O
L T S
A
OU TP
LIN
U T
W
C
ELD
OLN
ELEC
TER M I N
A
TRI
L S
C
S
W
EL
A
INVERTE
R
EC
N
I N
T
G
R E M O
T E
C V
3
50-PRO
P O W E
R
O N
O F F
Single Phase Input
Connect green/yellow lead to ground per National Electrical Code. Connect blue and brown leads to power. Wrap black lead with tape to provide 600V insulation.
Three Phase Input
Connect green/yellow lead to ground per appropriate National Electric Code. Connect blue, black and brown leads to power.
CONNECTIONS OF WIRE FEEDERS TO
LN-10 Connection Instructions
• Turn the Invertec power switch "off".
• Connect the K1505 control cable from the LN-10 to the
14-pin MS-style connector
.
• Connect the electrode cable to the output terminal of polarity required by the electrode. Connect the work lead to the other terminal.
• Set the meter polarity switch on the front of the Invertec to coincide with wire feeder polarity used.
• See the LN-10 manual for details on accessing Control DIP Switch
BLACK GREEN/YELLOW BLUE
BROWN
EX350ie
EX350ie (CE) (RED-D-ARC)
Page 12
A-3
,,
Output Terminals Always Hot.
Power source contactor switch must be in the "ON" position or use a K848 Junper Plug Kit.
INSTALLATION
LN-15 Connection Instructions
• Turn the
EX350ie (CE)
power switch "off".
• Connect the electrode cable to the output terminal of polarity required by electrode. (See Figures below)
ACROSS THE ARC MODEL
Output Terminals
RANGER 9, RANGER 300 DLX COMMANDER 300
EX350ie (CE)
COMMANDER 500 RANGER 2V35050 RANGER 305G
TWIST-MATE
Always Hot.
Power source contactor switch must be in the "ON" position or use a K848 Junper Plug Kit.
Electrode Cable
semiautomatic wire feeder K1870-1
Work Clamp
CONTROL CABLE MODEL
EX350ie (CE)
Electrode Cable
• Set the meter polarity switch on the front of the
to coincide with wire feeder polarity used.
(CE)
EX350ie
LN-25 Connection Instructions
• Turn the
EX350ie (CE)
power switch "off".
• Connect the electrode cable to the output terminal of polarity required by electrode. Connect the work lead to the other terminal.
• LN-25 with Remote Control options can be used with the EX350ie (CE)
. The 6-Pin (K444-1) and 14-pin (K444-2) remotes can be connected directly to the 6-pin & 14-pin MS-style connector. The 42 Volt Remote Voltage and Output Control (K624-2) Kit can be connected to the EX350ie (CE)
14-pin MS-style connector using Remote Control Cable assembly K627- [ ]. LN-25s with a K431-1 remote kit can be connected to the
EX350ie (CE)
14-pin MS-style connector using a K432 cable and K876 adapter. (See connection diagram S19899). Or the K432 cable could be modified with a K867 Universal Adapter Plug (See connection diagram S19405) to connect it to
EX350ie (CE)
the
14-pin MS-style connector.
A-3
• If a remote control such as K857 is to be used with the LN-742, the remote can be connected directly to the EX350ie (CE) or use a K864 adapter to connect the LN-742 and the remote to the nector
Cobramatic Connection Instructions
• Turn the EX350ie (CE) power switch "off"
• Connect the control cable from the Cobramatic to
• Connect the electrode cable to the output terminal
• Set the meter polarity switch on the front of the
• If a remote control such as K857 is to be used
CONNECTION OF WIRE FEEDERS TO EX350ie (CE)
Wire feeders other than these listed may be used pro­vided that the auxiliary power supply capacity of the EX350ie (CE) is not exceeded. K867 Universal Adapter Plug may be required. See connection dia­gram S24985 on page F-4.
REMOTE CONTROL OF INVERTEC
Remote Control K857, Hand Amptrol K963 and Foot Amptrol K870.
NOTE: MOUNTING SCREWS CA
6-pin MS-style connector
on the front of the
14-pin MS-style con-
.
the
14-pin MS-style connector
.
of the polarity required by electrode. Connect the work lead to the other terminal.
Invertec to coincide with wire feeder polarity used.
with the Cobramatic, the remote can be connected directly to the
6-pin MS-style connector
on the front of the Invertec or use a K864 adapter to connect the cobramatic and the remote to the style connector
.
14-pin MS-
UNDERCARRIAGE MOUNTINGS
MOUNTING HOLE LOCATIONS
CHES INSIDE THE MACHINE.
0.5 IN
N NOT PROTR
3.50
UDE MORE THAN
LN-742 Connection Instructions
• Turn the EX350ie (CE) power switch "off"
• Either a K591 or a K593 Input cable assembly is required to connect the LN-742 to the EX350ie (CE).
• Connect the control cable from the LN-742 to the 14-pin MS-style connector
.
• Connect the electrode cable to the output terminal of the polarity required by electrode. Connect the work lead to the other terminal.
• Set the meter polarity switch on the front of the Invertec to coincide with wire feeder polarity used. The wire feeder will now display the welding volt­age.
EX350ie (CE) (RED-D-ARC)
11.8
1/4-20 NUT (4 PLACES)
10.00
4
5.50
4/01
M19527
Page 13
A-4
PARALLEL OPERATION
The EX350ie (CE) are operable in parallel in CC mode. For best results, the currents of each machine should be reasonably well shared. As an example, with two machines set up in parallel for a 400 amp procedure, each machine should be set to deliver approximately 200 amps, not 300 amps from one and 100 amps from the other. This will minimize nuisance shutdown conditions. In general, more than two machines in parallel will not be effective due to the voltage requirements of procedures in that power range.
To set machine outputs, start with output control pots and arc control pots in identical positions. Use the output control pots to balance the currents and main­tain the desired current. The arc control pots should be kept identical on the two machines.
INSTALLATION
A-4
EX350ie (CE) (RED-D-ARC)
Page 14
B-1 SAFETY PRECAUTIONS
OPERATION
OPERATIONAL FEATURES and CONTROLS:
B-1
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or electrode with skin or wet clothing.
• Insulate yourself from work and ground.
• Always wear dry insulating gloves.
------------------------------------------------------------------------
FUMES AND GASES can be danger­ous.
• Keep your head out of fumes.
• Use ventilation or exhaust to remove fumes from breathing zone.
------------------------------------------------------------------------
WELDING SPARKS can cause fire or explosion.
• Keep flammable material away.
• Do not weld on closed containers.
------------------------------------------------------------------------
ARC RAYS can burn eyes and skin.
• Wear eye, ear and body protection.
------------------------------------------------------------
See additional warning information at
front of this operator
-----------------------------------------------------------
ʼs manual.
UPPER CONTROL PANEL
1. AMPS Meter
• Prior to STICK or TIG operation (current flow), the meter displays preset current value (either 2 amps or +/- 3% (e.g. 3 amps on 100), whichever is greater).
• Prior to CV operation, the meter displays four dashes indicating non-presettable AMPS.
• During welding, this meter displays actual average amps.
• After welding, the meter holds the actual current value for 5 seconds. Output adjustment while in the "hold" period results in the "prior to operation" characteristics stated above. The displays blink indicating that the machine is in the "Hold" period.
2. VOLT METER
• Prior to CV operation (current flow), the meter dis­plays desired preset voltage value (+/- .5V).
• Prior to STICK or TIG operation, the meter dis­plays the Open Circuit Voltage of the Power Source or four dashes if the output has not been turned on.
• During welding, this meter displays actual average volts.
• After welding, the meter holds the actual voltage value for 5 seconds. The displays blink indicating that the machine is in the "Hold" period.
• Output adjustment while in the "hold" period results in the "prior to operation" characteristics stated above.
GENERAL DESCRIPTION
PRODUCT DESCRIPTION & DUTY CYCLE
The EX350ie (CE) offers multi mode CV and CC DC welding and is rated at 350 amps, 34 volts at a 60% duty cycle with 3 phase input. It is also rated at 320 amps with single phase input. It is rated at 275 amps, 100% duty cycle.
EX350ie (CE) (RED-D-ARC)
3. OUTPUT CONTROL
• Output control is conducted via a single turn poten­tiometer.
• Adjustment is indicated by the meters as stated above.
• When in TIG modes, this control sets the maxi­mum welding current. Full depression of a foot or hand Amptrol results in the preset level of current.
4. WELD TERMINALS-REMOTE , ON
• Two status lights indicate the location of trigger control as determined by the "WELD TERMINALS" push button.
• If trigger control is local "weld terminals on", the ON display will be lit.
• If trigger control is remote "weld terminals remotely controlled", the REMOTE display will be lit.
• The unit will power up in "pre-determined pre­ferred" trigger modes.
STICK = ON TIG and CV = ON or REMOTE depending if remote output controls are connected to the machine.
Page 15
B-2
REMOTE
ON
REMOTE
LOCAL
WELD TERMINALS
OUTPUT
CONTROL
SELECT
SELECT
MPS
A
OLTS
V
OPERATION
5. THERMAL
• This status light indicates when the power source has been driven into thermal overload. If the out­put terminals were "ON", the "ON" light will blink indicating that the output will be turned back on once the unit cools down to an acceptable temper­ature level. If the unit was operating in the "REMOTE" mode, the trigger will need to be opened before or after the thermal has cleared and closed after the machine has cooled down to an acceptable temperature to establish output.
6. CONTROL-REMOTE , LOCAL
• Two status lights indicate the location of output control as pre-determined by the power sources auto-configure system.
• The LOCAL display will be lit when control is at the power source.
• The REMOTE display will be lit when a remote pot/control is detected.
These Output Control configurations can be over­ridden (switched) with the CONTROL push button. When changed, the unit will power up in the config­uration it was in when it was last powered down.
B-2
CC-STICK SOFT: The Stick Soft process features
continuous control ranging from 5 to 425 amps. This mode was intended for most SMAW applications, and Arc Gouging.
• Arc Gouging: Setting the output of the Stick Soft mode to 425 amps and/or setting the arc control to
9.5 or above will enable the arc-gouging mode. The actual output current will depend on the size of carbon used. The recommended maximum size carbon is 5/16"(7.9mm).
• The Hot Start control regulates the starting current at arc initiation. Hot Start can be adjusted from min­imum (0), with no additional current added at arc start, to maximum (10), with double the preset cur­rent or 425 amps (max of machine) added for the first second after arc initiation.
• The Arc Control regulates the Arc Force to adjust the short circuit current. The minimum setting (-10) will produce a "soft" arc and will produce minimal spatter. The maximum setting (+10) will produce a "crisp" arc and will minimize electrode sticking.
CC-STICK CRISP: The Stick Crisp mode features continuous control from 5 to 425 amps. This mode was intended primarily for pipe welding applications.
Hidden Middle Control Panel – Process Set Up Panel
The middle control panel is removable to allow for upgrades (see Field Installed Options/Accessories).
Additionally, this panel is hidden by an access door to reduce appeared complexity and provide protection to the controls.
7. WELD MODE SELECT
The Mode Control button selects the following weld­ing modes desired.
1
5
6
7
11
12
FIGURE 1
MPS
CONTROL
REMOTE
LOCAL
SELECT
• The Hot Start control regulates the starting current at arc initiation. Hot Start can adjust starting current up or down by 25% of the preset value. The recom­mended setting for Hot Start is 5 where the initial current is equal to the preset current.
• Arc Gouging: Setting the output of the stick crisp mode to 425 amps and/or setting the arc control to
9.5 or above will enable the arc-gouging mode. The actual output current will depend on the size of car­bon used. The recommended maximum size car­bon is 5/16”(7.9mm)
2
OLTS
3
WELD TERMINALS
REMOTE
ON
OUTPUT
SELECT
4
8
9
EX350ie (CE) (RED-D-ARC)
10
Page 16
B-3
• The Arc Control regulates the Arc Force to adjust the short circuit current. The minimum setting (-10) will produce a "soft" arc and will produce minimal spatter. The maximum setting (+10) will produce a "crisp" arc and will minimize electrode sticking.
TIG GTAW: The TIG mode features continuous control from 5 to 425 amps. The TIG mode can be run in either the TIG touch start or high frequency assisted start mode.
• The Hot Start control selects the starting mode
desired. A setting of less than 5, the TIG lift start mode is selected. The OCV is controlled below 10v and the short circuit "TIG touch" current is maintained at 25 amps independent of the preset current. When the tungsten is lifted, an arc is initiated and the output is regulated at the preset value. Hot start settings between 0 and 5 regulate the arc initiation current. A setting of 5 results in the most positive arc initiation. A setting of 0 reduces hot start.
• Hot Start settings between 5 and 10, select high fre-
quency assisted starting TIG mode. In this range, the OCV of the machine is controlled between 50 and 70 volts. If using the Lincoln K930-1 TIG Module, set the Hot start to 10 for maximum OCV.
• The Arc Control is not used in the TIG mode.
OPERATION
B-3
CV-INNERSHIELD: The CV-INNERSHIELD mode
features continuous control from 10 to 45 volts. This mode was designed for self-shielded flux cored wires that require tight voltage control.
• The Hot Start control is not used in the CV-FLUX CORED mode.
• The Arc Control regulates pinch effect. At the mini­mum setting (-10), minimizes pinch and results in a soft arc. At the maximum setting (+10), maximizes pinch effect and results in a crisp arc. Most self­shielded wires work well at an Arc Control setting of 5.
8. HOT START and ARC CONTROL features have
different functions depending on the welding Mode that is active. Each feature is described under the welding mode heading. (See Item 6 for specified
Mode Operation)
LOWER CASE FRONT
The output studs, line switch and remote connector are located on the lower case front.
9. Both STUDS contain "Twist-Mate" connector
inserts.
• The Negative stud is configured to accept the pass through gas system.
TIG SOLENOID OPTION
The Solenoid only operates when the EX350ie (CE) is in the TIG mode. If the Weld Terminals are in “Remote” then the solenoid will open when the arc start switch is closed. The solenoid will close after the arc switch has been opened and the post flow time expired.
If the Weld Terminals are turned “ON”, then the solenoid will open when the electrode is touch to the work. The electrode needs to remain in contact with the work to allow for gas coverage before attempting to start the arc. The solenoid will close after the arc has been broken and the post flow time expired.
CV-WIRE: The CV-WIRE mode features continuous control from 10 to 45 volts. The mode was intended for most GMAW, FCAW, and MCAW applications.
• The Hot Start control is not used in the CV-WIRE mode.
• The Arc Control regulates pinch effect. At the mini­mum setting (-10), minimizes pinch and results in a soft arc. Low pinch settings are preferable for welding with gas mixes containing mostly inert gases. At the maximum setting (+10), maximizes pinch effect and results in a crisp arc. High pinch settings are prefer-
2
able for welding FCAW and GMAW with CO
.
EX350ie (CE) (RED-D-ARC)
10. The ON-OFF switch is a 3-phase circuit breaker
rated at 100 amps per leg.
11. The METER POLARITY switch is located above
the output connectors. The switch provides a work connection for wire feeder voltmeters. Place the switch in the position of the electrode polarity indi­cated by the decal. The switch does not change
the welding polarity.
12. 6-PIN MS-style connector for remote control.
REMOTE CONTROL of the OUTPUT CON­TROL and WELD TERMINALS
The EX350ie (CE) has auto sensing of remote output controls. If after connecting or removing a remote, the EX350ie (CE) did not configured the way you would like the local or remote control settings can be changed by pushing the OUTPUT CONTROL or WELD TERMINAL button. (A user cannot select between the 6 and 14-pin MS-style connector.)
CV modes
• The remote will default to the 14-pin MS-style con­nector remote if a remote is connected. If no remote is connected to the 14-pin MS-style connec­tor then the remote will default to the 6-pin MS-style connector if a remote is connected to it.
• In all of the CV modes, the WELD TERMINAL con­trol will default to REMOTE.
Page 17
B-4
TIG mode
• The remote will default to the 6-pin MS-style if a remote control is connected to the 6-pin MS-style and to the 14-pin MS-style connectors. If a remote is not connected to the 6-pin MS-style connector then the remote will default to the 14-pin MS-style connector if a remote is connected.
• If a remote control is connected to any of the amphenols the WELD TERMINAL control will default to REMOTE. If there are not any remote control devices attached the WELD TERMINAL control will default to ON.
OPERATION
B-4
Types of Remote WELD TERMINAL Control
• The EX350ie (CE) Weld Terminals can be con­trolled from each of the amphenol connectors. The circuit has a nominal OCV of 15VDC and requires a dry contact closure (less than 100 ohms) to activate the output of the EX350ie (CE).
• 14 Pin Amphenols the Weld Terminals are con­trolled from pins C (lead 2) and pin D (lead 4). Pin C is positive.
• 6 Pin Amphenol the Weld Terminals are controlled from pin D (lead 2) and pin E (lead 4). In the 6-pin amphenol pin D is positive.
CC-Stick modes
• The remote will default to only the 6-pin amphenol if a remote is connected to it.
• The WELD TERMINAL control will default to ON with or without a remote connected.
Types of Remote OUTPUT CONTROL
• The EX350ie (CE) Output Control can be controlled by either a potentiometer connected between 77 & 75 with the wiper connected to 76 or a 0V to 10V DC supply connected between 76 & 75. (76 needs to be positive)
• 14-pin MS-style connector lead 75 is pin G, lead 76 is pin F and lead 77 is pin E.
• 6-pin MS-style connector lead 75 is pin C, lead 76 is pin B and lead 77 is pin A.
Potentiometer Control
• The total resistance should be between 2000 ohms (2K) and 10,000 ohms (10K)
• The machine output will be at minimum when lead 76 (wiper) is at the end of the potentiometer that is connected to 75. The machineʼs output will increase as the wiper of the potentiometer is moved to the end that is connected to 77. (Note: In TIG mode, moving the lead 76 (wiper) to lead 77 would produce the current that has been set by the EX350ie (CE) front panel Output Control.)
• Remotes of this type offered by Lincoln Electric are the K857, K812 and K870.
AUXILIARY POWER
• 42VAC and 24VAC power is available from the 14­pin MS-style connector. These supplies are intend­ed to supply power for auxiliary equipment like wire feeders.
• 42 VAC supply is rated at 5.5 amps and is protect­ed by a 10 amp breaker located by the amphenol.
• 24 VAC supply is rated at 5.5 amps and is protect­ed by a 10 amp breaker located by the amphenol.
LIMITATIONS
• The EX350ie (CE) is not recommended for processes other than those listed.
• The EX350ie (CE) can only be used with the rec­ommended equipment and options.
RECOMMENDED PROCESSES
Properly equipped, the EX350ie (CE) supports GMAW, FCAW, SMAW, GTAW and CAC-A processes for a variety of materials, including mild steel, stainless steel, cored wires, and aluminum
Voltage Control
• The supply should be an isolated supply. (Not ref­erenced to earth ground, any auxiliary power from the EX350ie (CE) or the welding output) should be capable of supplying at least 20mA.
• 0 volts supplied to 76 will set the EX350ie (CE) to minimum output for the mode that has been select­ed while 10 volts supplied to 76 will set the EX350ie (CE) to the maximum output for the mode. (Note: In TIG mode, 10 volts supplied to lead 76 would produce the current that has been set by the EX350ie (CE) front panel Output Control.)
The supply
EX350ie (CE) (RED-D-ARC)
Page 18
C-1
ACCESSORIES
C-1
OPTIONS / ACCESSORIES
• The EX350ie (CE) provides the hardware to
and connect to 24 or 42 wire feeders.
K857 Remote Output Control K814 Arc Start Switch K812 Hand Operated Amptrol K870 Foot Operated Amptrol K428-2, K446, K449-3 LN-25 K617 (-1 or -2) K618 (-1 or -2) LN-742 K1559-1, K1564-1 LN-10 K1499-1, K1521-1 DH-10 K1587-1 Cobramatic
Welding Cable Connectors:
• K852-70 1/0-2/0 cable
• K852-95 2/0-3/0 cable
FIELD INSTALLED OPTIONS
• K1762-2 TIG Gas Control Kit
power
QUICK DISCONNECT PLUGS
A quick disconnect system is used for the welding cable connections. The K852-70 is designed to accept a welding cable size of 1/0 to 2/0.
1. Remove 25mm (1 in.) of welding cable insulation.
2. Slide rubber boot onto cable end. The boot end may be trimmed to match the cable diameter. Soap or other lubricant will help to slide the boot over the cable.
WELDING CABLE
25 mm
1 in.
TRIM
BOOT
3. Slide the copper tube into the brass plug.
4. Insert cable into copper tube.
SET SCREW
• K1764-1 Undercarriage
• K1838-1 Valet Style Undercarriage
COPPER TUBE
BRASS PLUG
5. Tighten set screw to collapse copper tube. Screw must apply pressure against welding cable. The top of the set screw will be well below the surface of the brass plug after tightening.
6. Slide rubber boot over brass plug. The rubber boot must be positioned to completely cover all electrical surfaces after the plug is locked into the receptacle.
EX350ie (CE) (RED-D-ARC)
Page 19
D-1
R
MAINTENANCE
D-1
SAFETY PRECAUTIONS
WARNING
----------------------------------------------------------------------
­ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
EXPLODING PARTS can cause injury.
Failed parts can explode or cause other
parts to explode when power is applied.
Always wear a face shield and long
sleeves when servicing.
------------------------------------------------------------------------
See additional warning information
throughout this operatorʼs manual.
------------------------------------------------------------
CAPACITOR DISCHARGE PROCEDURE
1. Obtain a power resistor (25 ohms, 25 watts).
2. Hold resistor body with electrically insulated glove. DO NOT TOUCH TERMINALS. tor terminals across the two studs in the position shown. Hold in each position for 1 second. Repeat for all four capacitors.
Connect the resis-
RESISTOR
VISUAL INSPECTION
Clean interior of machine with a low pressure air stream. Make a thorough inspection of all compo­nents. Look for signs of overheating, broken leads or other obvious problems. Many problems can be uncovered with a good visual inspection.
ROUTINE MAINTENANCE
1. Every 6 months or so the machine should be cleaned with a low pressure airstream. Keeping the machine clean will result in cooler operation and higher reliability. Be sure to clean these areas:
• All printed circuit boards
• Power switch
• Main transformer
• Input rectifier
• Auxiliary Transformer
• Reconnect Switch Area
• Fan (Blow air through the rear louvers)
2. Examine the sheet metal case for dents or breakage.
Repair the case as required. Keep the case in good con­dition to insure that high voltage parts are protected and correct spacings are maintained. All external sheet metal screws must be in place to insure case strength and electrical ground continuity.
PERIODIC MAINTENANCE
Overload Protection
The machine is electrically protected from producing high output currents. Should the output current exceed 430A, an electronic protection circuit will reduce the current to approximately 100A. The machine will continue to produce this low current until the protection circuit is reset. Reset occurs when the output load is removed.
CAPACITO TERMINALS
3. Use a DC voltmeter to check that voltage is not present across the terminals on all four capacitors.
EX350ie (CE) (RED-D-ARC)
Thermal Protection
Thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating. If excessive operating temperature should occur, the thermostat will prevent output voltage or current. The meter will remain energized during this time.
Thermostats are self-resetting once the machine cools sufficiently. If the thermostat shutdown was caused by excessive output or duty cycle and the fan is operating normally, the Power Switch may be left on and the reset should occur within a 15 minute period.
Page 20
E-1
TROUBLESHOOTING
HOW TO USE TROUBLESHOOTING GUIDE
WARNING
Service and Repair should only be performed by Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
__________________________________________________________________________
E-1
This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled “PROBLEM (SYMP­TOMS)”. This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting.
Step 2. POSSIBLE CAUSE.
The second column labeled “POSSIBLE CAUSE” lists the obvious external possibilities that may contribute to the machine symptom.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the Possible Cause, generally it states to contact your local Authorized Field Service Facility.
If you do not understand or are unable to perform the Recommended Course of Action safely, contact your local Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
EX350ie (CE)(RED-D-ARC)
Page 21
E-2
PROBLEMS
(SYMPTOMS)
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E-2
Major physical or electrical damage is evident when the sheet metal covers are removed.
Input fuses keep blowing, or input breaker keeps tripping
Machine will not power up (No lights)
1. Contact your local authorized Field Service facility for technical assistance.
1. Make certain that the fuses or breakers are properly sized. See installation section of the manual for recommended fuse and breaker sizes.
2. Welding procedure is drawing too much output current, or duty cycle is too high. Reduce output current, duty cycle or both.
3. There is internal damage to the power source. Contact an autho­rized Service facility.
1. Make certain that the power switch is in the "ON" position.
2. The circuit breaker in the recon­nect area may have opened. Reset. Check input voltage sec­tion below.
3. Input voltage selection made improperly. Power down, check input voltage reconnect accord­ing to diagram on reconnect cover.
4. The 6 amp breaker may have opened. Check for overload on 42VAC or 24VAC supply from the 14 pin MS-style connector.
I
f all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Authorized Field Service Facility.
Machine wonʼt weld, canʼt get any output.
1. If the displays show an Err ### see the fault section for correc­tive action.
2. If the displays are not lit refer to machine will not power up sec­tion.
3. If the thermal symbol is lit refer to the thermal section.
4. If the output terminals are in Remote control switch to "ON" and check for output voltage. If output voltage is now present check for correct remote control connection and operation.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
EX350ie (CE) (RED-D-ARC)
Page 22
E-3
PROBLEMS
(SYMPTOMS)
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E-3
Thermal symbol is lit
Wire feeder wonʼt work. Apparently no power to wire feeder
1. Check for proper fan operation. If fan is not operating correctly the CB 2 breaker may have opened. Check for an overload on the 115VAC. Blow air in rear louvers to remove dirt from around fan.
2. Check for material blocking intake or exhaust louvers.
3. Blow air in the rear louvers to clear dirt from the fan.
1. Check circuit breakers by the wire feeder receptacles on the rear of the machine. Reset
2. Check the control cable between the power source and the wire feeder for continuity.
I
f all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
EX350ie (CE) (RED-D-ARC)
Page 23
E-4
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-4
Fault Codes
Code Description Corrective Action 31 Primary over current. If condition persists The machine needs to
contact an authorized be turned off and back Field Service Shop
on to reset the machine.
32 CAP bank A under voltage. Check input power Self-clearing as 33 CAP bank B under voltage. reconnect to make sure condition ceases. 34 CAP bank A over voltage. the machine is connected 35 CAP bank B over voltage. for the input power being 37 Soft start Failed. supplied. Cycle power. 39 Glitch on the primary over Check the machine Self-clearing as
current fault interrupt; possibly ground. condition ceases. caused by noise or a signal level If problem persists (misc. hardware fault #1) contact an authorized
Field Service Shop
43 CAP delta; CAP A and B are out Check input power
of balance. reconnect to make sure
the machine is connected for the input power being supplied.
44 Main CPU problem. The DSP Check the machine
has detected a problem with the ground. CPU.
47 Glitch on the CAP/heart beat If problem persists
interrupt; possibly caused by contact an authorized noise or a signal level right at Field Service Shop the trip threshold. (misc. hardware fault #2)
48 The main contactor opened If condition persists Self-clearing
unexpectedly. (misc. hardware contact an authorized fault #3) Field Service Shop
"bad The selected weld mode does If condition persists Press the Mode nodeʼ not exist in the weld table that is contact an authorized Select button to “####”
presently loaded in the machine. Field Service Shop select a different
mode
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
EX350ie (CE) (RED-D-ARC)
Page 24
E-5
Observe all Safety Guidelines detailed throughout this manual
TROUBLESHOOTING
Displays Description
E-5
Scrolling dash
Appears at power up while the machine is going through its self configu­ration
"Err" "####" Fault code display. The first fault to occur will be displayed for three
seconds. The display will cycle through fault codes for all faults that persist after the initial three-second period are displayed for 1 sec­ond each.
"----" "----" Weld mode is changing
"----" "####" A constant voltage weld mode is selected, machine output is off.
The numeric value in the right display is the work point.
"####" "----" A constant current weld mode is selected, machine output is off.
The numeric value in the left display is either the work point or a work point limit, depending on the weld mode and remote configura­tion.
"####" "####"(on steady) Machine output is on. Left display is current, right display is voltage.
If actively welding, the displays are arc current and arc voltage. If not actively welding, the display will show work point.
"####" "####" (blinking) Weld just finished – the average arc voltage and current will be
blinked for 5 seconds following a weld. If the work point changes during this 5 second period, the display will revert to the above mode.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
EX350ie (CE) (RED-D-ARC)
Page 25
F-1
DIAGRAMS
2) K963 HAND AMPTROL
3) K870 FOOT AMPTROL
TO: 1) K857 REMOTE CONTROL
CABLE RECEPTACLE (6 SOCKET)
TO: 1) LN-7 WIRE FEEDERS
CABLE RECEPTACLE (14 SOCKET)
F-1
S19309
4-19-96D
TO: 1) LN-25 WIRE FEEDERS
CABLE RECEPTACLE (6 SOCKET)
TURN THE POWER SWITCH OF THE WELDING POWER
SOURCE "OFF" BEFORE INSTALLING PLUGS ON CABLES
OR WHEN CONNECTING OR DISCONNECTING PLUGS TO
WELDING POWER SOURCE.
REMOTE CONTROL ADAPTERS
STRAIGHT PLUG (14 PIN)
TO POWER SOURCE
K864
EX350ie (CE) (RED-D-ARC)
STRAIGHT PLUG (14 PIN)
TO POWER SOURCE
K876
Page 26
F-2
LN-7
CONTROL
BOX
LN-7
CONTROL
BOX
N.C.
N.C.
DIAGRAMS
K291 OR K404
K291 OR K404
2
4
2
32
32
4
21
21
31
31
INPUT CABLE
INPUT CABLE
GREEN
GREEN
757677
757677
GND
GND
K775 OPTIONAL
REMOTE CONTROL
K775 OPTIONAL
REMOTE CONTROL
F-2
S19404
S19404
12-10-93A
2
4
2
828142
828142
SPARE
SPARE
service this machine.
service this machine.
Only qualified persons should install, use or
Only qualified persons should install, use or
Before connecting the wire feeder.
Before connecting the wire feeder.
using the disconnect switch at the fuse box
using the disconnect switch at the fuse box
Turn off input power to the Welding Power Source
Turn off input power to the Welding Power Source
SHOCK
SHOCK
ELECTRIC
ELECTRIC
CAN KILL
WARNING
WARNING
CAN KILL
41
41
14 PIN
AMPHENOL
14 PIN
AMPHENOL
31
31
32
32
4
K867 PLUG TO LN-7 - CONNECTION DIAGRAM
21
21
K867 UNIVERSAL
K867 UNIVERSAL
757677
757677
GND
GND
ADAPTER PLUG
ADAPTER PLUG
N.D.
N.D.
-
WORK
WORK
-
TO
TO
ELECTRODE CABLE
TO LN-7
ELECTRODE CABLE
TO LN-7
EX350ie (CE) (RED-D-ARC)
+
+
POWER SOURCE
POWER SOURCE
WITH 115VAC
WITH 115VAC
AUXILIARY POWER
AUXILIARY POWER
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE.
N.D. SPLICE LEADS AND INSULATE.
N.D. SPLICE LEADS AND INSULATE.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
Page 27
F-3
DIAGRAMS
LN-25 WITH
K431 OPTION
F
E
N.C.
K432 REMOTE
B
D
A
CONTROL CABLE
C77
N.D.
S19405
1-25-91
F-3
2
2182814241
service this machine.
Only qualified persons should install, use or
Before connecting the wire feeder.
using the disconnect switch at the fuse box
Turn off input power to the Welding Power Source
SHOCK
ELECTRIC
WARNING
CAN KILL
31
GND
14 PIN
AMPHENOL
32
4
SPARE
K867 PLUG TO LN-25 - CONNECTION DIAGRAM
WORK
-
TO
ELECTRODE CABLE
TO LN-25
75
76
K867 ADAPTER
+
POWER SOURCE
N.E.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
N.D. REMOVE 6 PIN PLUG FROM K432 CABLE IN ORDER TO CONNECT K867 PLUG.
LABEL EACH LEAD (A THRU F) AS THEY ARE REMOVED FROM 6 PIN PLUG.
N.E. SPLICE LEADS AND INSULATE.
EX350ie (CE) (RED-D-ARC)
Page 28
F-4
DIAGRAMS
N.D.
N.C.
NOT USED ON POWER SOURCE
24 VAC / 5.5 AMP
CONNECT TOGETHER FOR WELDING OUTPUT
24 VAC / 5.5 AMP
42 VAC / 5.5 AMP
REMOTE OUTPUT CONTROL
MIN.
115 VAC / 2 AMP
POWER SOURCE FRAME CONNECTION
10K
WIRE FEEDER VOLTMETER CONNECTION
CONNECTS TO (WORK TERMINAL) OF POWER SOURCE
F-4
3-1-00
TO
WIRE FEEDER
S24985
2
4
82
81
service this machine.
Only qualified persons should install, use or
Before connecting the wire feeder.
using the disconnect switch at the fuse box
Turn off input power to the Welding Power Source
SHOCK
ELECTRIC
WARNING
CAN KILL
41
SPARE
14 PIN
31
42
AMPHENOL
32
21
GND
77
76
75
K867 UNIVERSAL
ADAPTER PLUG
K867 UNIVERSAL ADAPTER / INVERTEC - CONNECTION DIAGRAM
WORK
-
TO
ELECTRODE CABLE
+
POWER SOURCE
WITH 115VAC
AUXILIARY POWER
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE.
2
4
TO
K867
N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION
RELAY TO CLOSE LEADS 2 & 4.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.
EX350ie (CE) (RED-D-ARC)
Page 29
F-5
DIAGRAMS
LN-25 WITH
K431 OPTION
6 PIN
AMPHENOL
K432 REMOTE
CONTROL CABLE
F-5
S19899
1-25-91
service this machine.
Only qualified persons should install, use or
Before connecting the wire feeder.
using the disconnect switch at the fuse box
Turn off input power to the Welding Power Source
SHOCK
ELECTRIC
WARNING
CAN KILL
14 PIN
AMPHENOL
K876 ADAPTER
K876 ADAPTER TO LN-25 - CONNECTION DIAGRAM
WORK
-
TO
ELECTRODE CABLE
TO LN-25
+
POWER SOURCE
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE.
N.C. FOR POWER SOURCES WITH 6 PIN AMPHENOL, K432 CABLE CAN BE CONNECTED DIRECTLY.
EX350ie (CE) (RED-D-ARC)
Page 30
F-6
LN-7
CONTROL
BOX
14 PIN
AMPHENOL
DIAGRAMS
K857
K480-7 INPUT CABLE
6 PIN
AMPHENOL
REMOTE CONTROL
K963
HAND AMPTROL
K870
FOOT AMPTROL
OR
OR
F-6
S19901
4-19-96D
service this machine.
Only qualified persons should install, use or
Before connecting the wire feeder.
using the disconnect switch at the fuse box
Turn off input power to the Welding Power Source
ADAPTER
K864
WARNING
SHOCK
ELECTRIC
CAN KILL
14 PIN
AMPHENOL
K864 ADAPTER TO LN-7 & REMOTE CONTROL - CONNECTION DIAGRAM
WORK
-
TO
ELECTRODE CABLE
TO LN-7
+
WITH 115VAC
POWER SOURCE
AUXILIARY POWER
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
N.C. K480-7 INPUT CABLE CAN BE CONNECTED DIRECTLY IF REMOTE CONTROL IS NOT REQUIRED.
REVERSE ELECTRODE AND WORK CABLE AT POWER SOURCE.
N.D. K864 ADAPTER CANNOT BE USED WITH AN LN-25.
EX350ie (CE)(RED-D-ARC)
Page 31
F-7
DIAGRAMS
F-7
EX350ie (CE) (RED-D-ARC)
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside
the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
Page 32
F-8
DIMENSION PRINT
F-8
27.82
21.60
3.44
5.50
UDE MORE THAN
10.00
N NOT PROTR
MOUNTING HOLE LOCATIONS
NOTE: MOUNTING SCREWS CA
3.50 1/4-20 NUT (4 PLACES)
CHES INSIDE THE MACHINE.
0.5 IN
4/01
M19527
4
11.8
9
4.7 1
EX350ie (CE) (RED-D-ARC)
0
2.44
13.1
1
Page 33
NOTES
EX350ie (CE) (RED-D-ARC)
Page 34
WARNING
Spanish
AVISO DE
PRECAUCION
Do not touch electrically live parts or
electrode with skin or wet clothing.
Insulate yourself from work and
ground.
No toque las partes o los electrodos
bajo carga con la piel o ropa moja­da.
Aislese del trabajo y de la tierra.
Keep flammable materials away.
Mantenga el material combustible
fuera del área de trabajo.
Wear eye, ear and body protection.
Protéjase los ojos, los oídos y el
cuerpo.
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
Japanese
Chinese
Korean
Arabic
Ne laissez ni la peau ni des vête-
ments mouillés entrer en contact avec des pièces sous tension.
Isolez-vous du travail et de la terre.
Berühren Sie keine stromführenden
Teile oder Elektroden mit Ihrem Körper oder feuchter Kleidung!
Isolieren Sie sich von den
Elektroden und dem Erdboden!
Não toque partes elétricas e elec-
trodos com a pele ou roupa molha­da.
Isole-se da peça e terra.
Gardez à l’écart de tout matériel
inflammable.
Entfernen Sie brennbarres Material!
Mantenha inflamáveis bem guarda-
dos.
Protégez vos yeux, vos oreilles et
votre corps.
Tragen Sie Augen-, Ohren- und Kör-
perschutz!
Use proteção para a vista, ouvido e
corpo.
READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.
LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.
LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER­STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.
Page 35
Keep your head out of fumes.
Use ventilation or exhaust to
remove fumes from breathing zone.
Turn power off before servicing.
Do not operate with panel open or
guards off.
WARNING
Los humos fuera de la zona de res-
piración.
Mantenga la cabeza fuera de los
humos. Utilice ventilación o aspiración para gases.
Gardez la tête à l’écart des fumées.
Utilisez un ventilateur ou un aspira-
teur pour ôter les fumées des zones de travail.
Vermeiden Sie das Einatmen von
Schweibrauch!
Sorgen Sie für gute Be- und
Entlüftung des Arbeitsplatzes!
Mantenha seu rosto da fumaça.
Use ventilação e exhaustão para
remover fumo da zona respiratória.
Desconectar el cable de ali-
mentación de poder de la máquina antes de iniciar cualquier servicio.
Débranchez le courant avant l’entre-
tien.
Strom vor Wartungsarbeiten
abschalten! (Netzstrom völlig öff­nen; Maschine anhalten!)
Não opere com as tampas removidas.
Desligue a corrente antes de fazer
serviço.
Não toque as partes elétricas nuas.
No operar con panel abierto o
guardas quitadas.
N’opérez pas avec les panneaux
ouverts ou avec les dispositifs de protection enlevés.
Anlage nie ohne Schutzgehäuse
oder Innenschutzverkleidung in Betrieb setzen!
Mantenha-se afastado das partes
moventes.
Não opere com os paineis abertos
ou guardas removidas.
Spanish
AVISO DE
PRECAUCION
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
Japanese
Chinese
Korean