Lincoln Electric IM894-B User Manual

®
RETURN TO MAIN MENU
VANTAGE 500 (CE)
IM894-B
March, 2010
For use with machines having Code Numbers:
Safety Depends on You
Lincoln arc welding and cutting equipment is designed and built wi th saf ety in mi nd. Ho wev er, you r ove r a ll sa fety can be increased by proper installation ... and thoughtful operation on your part. DO NOT INSTALL, OPER-
ATE OR REPAIR THIS EQUIP­MEN T WIT H O UT RE ADING THIS MANUAL AND THE SAFE­TY PRECAUTIONS CONTAINED THR O U GHOUT . A n d , m o st
importantly, think before you act and be careful.
11298, 11299, 11524, 11525, 11574, 11575
Equipped with VRD (VOLTAGE REDUCTION DEVICE) See Installation and Operation sections for an explanation.
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
OPERATOR’S MANUAL
Copyright © Lincoln Global Inc.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
i
SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause can­cer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
i
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
____________________________________________________
1.c. Do not add the fu el ne ar an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz­ing on con tact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. I n s om e cases it m ay be necessa ry to remove saf et y
gu a rds to per f orm req u ire d ma i nte n anc e . R emov e guards only when necessary and replace them when the ma i nten ance r e qui r ing th e ir rem o val is com plet e . Always use the greatest care when working near moving parts.
___________________________________________________
1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND MAGNETIC FIELDS may be dangerous
2.a. Elect ric curren t f lowing throu gh any conduc to r causes local ized Ele ctric an d Magnet ic Fields (EMF). Welding curre nt creat es EMF fiel ds aroun d weldin g cables and welding machines
2.b. EMF fi el ds may interfere with some pacemak er s, an d welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Nev er coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Mar ‘95
ii
SAFETY
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet cl othing. We ar dry, hole-fr ee
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding mu st be p erfo rmed u nder elec tric ally h azar dous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, elect rode reel, welding he ad, nozzle or semiaut omatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. N ev er simul ta neously to uch el ec tricall y “ hot” par ts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases. W he n w elding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
we lding with electrodes w hich requ ire s peci al ve ntil ation su ch as stai nles s or hard faci ng (s ee instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and within applicable OSHA PEL and ACGIH TLV limits using local exhaust or mechanical ventilation. In confined spaces or in some circum­st ance s, ou tdoors, a res pira tor m ay be require d. Additional precautions are also required when welding on galvanized steel.
5. b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the spe­cific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors form phosgene, a highly toxic gas, and other irritating prod­ucts.
5.d. Shielding gases used for arc welding can displace air and
cause injury or d ea th . A lw ay s u se enough ventilation, especially in confined areas, to insure breathing air is safe.
vapors
to
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the ma t eria l s afe t y data s h eet ( M SDS ) a n d fol l ow you r employer’s safety practices. MSDS forms are available from yo u r wel d ing d i str i but o r or f r om t h e man u fac t ure r .
5.f. Also see item 1.b.
Jan ‘09
iii
SAFETY
iii
WELDING and CUTTING SPARKS can cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
Re m embe r th a t we l din g spa r ks an d ho t materials from welding can easily go through small cracks an d op ening s to adj acent are as. Avoid wel din g n ear hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standar d Z49.1) and t he operating in formation for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even been “cleaned”. For information, purchase “Recommended Safe Practices for the Co n tain ers a nd P i pin g That H ave H eld H azar dous Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f. free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area incre ase the pos sibility of the welding cur rent passing through lifting chains, crane cables or other alternate cir­cuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
the welding sparks from starting a f ir e.
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode if damaged.
7.a. Us e o nly co m pre s sed gas cyl i nde r s containing the correct shielding gas for the pr o cess use d a n d p rop e rly oper atin g re g ulat ors d e sig n ed fo r t he gas a n d
pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Alw ay s k ee p cylinders in a n u pr ig ht position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. R ea d an d foll ow the instr uctio ns on c ompre ss ed g as cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Inst all equipment in accordance with the U.S. National Electrical Code, al l local codes and the manuf acturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Refer to http://www.lincolnelectric.com/safety for additional safety information.
Jan ‘09
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv­antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions pour le porte-électrode s’applicuent aussi au pistolet de soudage.
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de la mas se. Un co urt-cir cuit acc idental peut pro voquer u n échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible de la zone de travail qu’il est pratique de le faire. Si on place la masse sur la charpente de la construction ou d’autres endroits éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de lev­age, câbles de grue, ou autres circuits. Cela peut provoquer des risques d’incendie ou d’echauffement des chaines et des câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage. Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant d’opérations de dégraiss age, nettoya ge ou pistolage. La chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas fortement toxique) ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA Standard W 117.2-1974.
2. Dans le cas de travail au dessus du niveau du sol, se protéger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de n’importe quelle partie du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel, donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray­onnement de l’arc et des projections quand on soude ou quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de l‘arc.
c. Protéger l’aut re pe rs onnel travaillant à prox im ité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émi ses de l’arc de soudage. Se protéger avec des vêtements de protection libres de l’huile, tels que les gants en cuir, chemise épaisse, pan­talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les zones où l’on pique le laitier.
PRÉCAUTIONS DE SÛRETÉ POUR LES MACHINES À SOUDER À TRANSFORMATEUR ET À REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de l’électricité et aux recommendations du fabricant. Le dispositif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch­er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
Mar. ‘93
TThhaannkk YYoouu
vv
for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip­ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses­sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor­mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.
CUSTOMER ASSISTANCE POLICY
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
“Product Registration”. Please complete the form and submit your registration.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
vi
SAFETY
Electromagnetic Compatibility (EMC)
Conformance Products displaying the CE mark are in conformity with European Community Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (89/336/EEC). It was manufactured in conformity with a national standard that implements a harmonized standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment. It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.
Introduction All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions are received by other equipment, electrical interference may result. Electrical emissions may affect many kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions may be required when a welding power source is used in a domestic establishment.
Installation and Use The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it could involve construction of an electromagnetic screen enclosing the power source and the work complete with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where they are no longer troublesome.
vi
Note: The welding circuit may or may not be earthed for safety reasons according to national codes.
Changing the earthing arrangements should only be authorized by a person who is compe­tent to access whether the changes will increase the risk of injury, e.g., by allowing parallel welding current return paths which may damage the earth circuits of other equipment.
Assessment of Area Before installing welding equipment the user shall make an assessment of potential electromagnetic prob­lems in the surrounding area. The following shall be taken into account:
a) other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the
welding equipment;
b) radio and television transmitters and receivers;
c) computer and other control equipment;
d) safety critical equipment, e.g., guarding of industrial equipment;
e) the health of the people around, e.g., the use of pacemakers and hearing aids;
f) equipment used for calibration or measurement
g) the immunity of other equipment in the environment. The user shall ensure that other equipment being
used in the environment is compatible. This may require additional protection measures;
h) the time of day that welding or other activities are to be carried out.
L10093 3-1-96H
vii
SAFETY
Electromagnetic Compatibility (EMC)
Conformance Products displaying the CE mark are in conformity with European Community Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (89/336/EEC). It was manufactured in conformity with a national standard that implements a harmonized standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment. It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.
Introduction All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions are received by other equipment, electrical interference may result. Electrical emissions may affect many kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions may be required when a welding power source is used in a domestic establishment.
Installation and Use The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it could involve construction of an electromagnetic screen enclosing the power source and the work complete with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where they are no longer troublesome.
vii
Note: The welding circuit may or may not be earthed for safety reasons according to national codes.
Changing the earthing arrangements should only be authorized by a person who is compe­tent to access whether the changes will increase the risk of injury, e.g., by allowing parallel welding current return paths which may damage the earth circuits of other equipment.
Assessment of Area Before installing welding equipment the user shall make an assessment of potential electromagnetic prob­lems in the surrounding area. The following shall be taken into account:
a) other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the
welding equipment;
b) radio and television transmitters and receivers;
c) computer and other control equipment;
d) safety critical equipment, e.g., guarding of industrial equipment;
e) the health of the people around, e.g., the use of pacemakers and hearing aids;
f) equipment used for calibration or measurement
g) the immunity of other equipment in the environment. The user shall ensure that other equipment being
used in the environment is compatible. This may require additional protection measures;
h) the time of day that welding or other activities are to be carried out.
L10093 3-1-96H
viii
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications.......................................................................................................A-1
Machine Specification ...................................................................................................A-2
Safety Precautions ........................................................................................................A-3
VRD (Voltage Reduction Device)..................................................................................A-3
Location and Ventilation................................................................................................A-3
Stacking ........................................................................................................................A-3
Angle of Operation ........................................................................................................A-3
Lifting.............................................................................................................................A-3
High Altitude Operation .................................................................................................A-4
High Temperature Operation ........................................................................................A-4
Cold Weather Operation ......................................................................................................A-4
Towing..................................................................................................................................A-4
Vehicle Mounting..................................................................................................................A-4
Pre-Operation Engine Service..............................................................................................A-4
Oil..................................................................................................................................A-5
Fuel ...............................................................................................................................A-5
Engine Coolant..............................................................................................................A-5
Battery Connections......................................................................................................A-5
Muffler Outlet Pipe ........................................................................................................A-5
Spark Arrester ...............................................................................................................A-5
Remote Control .............................................................................................................A-5
Electrical Connections..........................................................................................................A-6
Machine Grounding ..............................................................................................................A-6
Welding Terminals................................................................................................................A-6
Welding Output Cables ........................................................................................................A-6
Cable Installation..................................................................................................................A-6
Auxiliary Power Receptacles and Plugs...............................................................................A-7
Standby Power Connections ................................................................................................A-7
Connection of Lincoln Electric Wire Feeders.................................................................A-7,A-8
________________________________________________________________________________
viii
Operation.........................................................................................................................Section B
Safety Precautions ..............................................................................................................B-1
General Description..............................................................................................................B-1
For Auxiliary Power ..............................................................................................................B-1
Engine Operation..................................................................................................................B-1
Add Fuel ...............................................................................................................................B-1
Break in Period.....................................................................................................................B-1
Welder Controls .............................................................................................................B-2,B-3
Engine Controls....................................................................................................................B-4
Fuel Consumption .........................................................................................................B-4
Starting and Stopping the Engine...........................................................................B-4,B-5
Welding Operation................................................................................................................B-5
Duty Cycle and Electrode Information...........................................................................B-5
Constant Current (Stick) Welding.........................................................................................B-5
Downhill Pipe (Stick) Welding .......................................................................................B-5
Tig Welding ...................................................................................................................B-6
Typical Current Ranges for Tungsten Electrodes .........................................................B-6
Wire Welding-CV...........................................................................................................B-7
Arc Gouging ..................................................................................................................B-7
Auxiliary Power.....................................................................................................................B-7
Simultaneous Welding and Power Loads .....................................................................B-7
Extension Cord Recommendations...............................................................................B-7
________________________________________________________________________________
Accessories.....................................................................................................Section C
Field Installed
________________________________________________________________________________
Options / Accessories ...............................................................................C-1
ix
TABLE OF CONTENTS
Maintenance......................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine Maintenance ............................................................................................D-1
Engine Service Items.............................................................................................D-1
Engine Oil Change..........................................................................................D-2
Engine Oil Filter Change.................................................................................D-2
Air Cleaner .....................................................................................................D-2
Service Instructions And Installation Tips for Engine Air Filter .......................D-3
Cooling System .....................................................................................................D-4
Fan Belt...........................................................................................................D-4
Fuel .................................................................................................................D-4
Bleeding the Fuel System ...............................................................................D-4
Fuel Filter ........................................................................................................D-5
Engine Adjustment ..........................................................................................D-5
Battery Maintenance .......................................................................................D-5
Servicing Optional Spark Arrestor ...................................................................D-5
Welder / Generator Maintenance ........................................................................D-6
Storage ...........................................................................................................D-6
Cleaning..........................................................................................................D-6
Brush Removal and Replacement ..................................................................D-6
________________________________________________________________________
Troubleshooting..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide.............................................................................E-2 thru E-6
________________________________________________________________________
Connection Diagrams, Wiring Diagrams and Dimension Print...................Section F
________________________________________________________________________
Parts List.................................................................................................................P-535
________________________________________________________________________
ix
A-1
INSTALLATION
TECHNICAL SPECIFICATIONS - VANTAGE® 500 (CE) (K2503-1, -2, -3, -4)
INPUT - DIESEL ENGINE
Make/Model Description Speed (RPM) Displacement Starting Capacities
cu. in. (ltrs.) System
A-1
Perkins 4 cylinder 135.6(2.2)
12VDC Battery & Oil:
404C-22T 37.2 HP High Idle 1575 starter
11298, 11299 1500 RPM
Perkins
404D-22T
11524, 11525 11574, 11575
Turbo Charged Full Load 1575 cold crank amps) water cooled Diesel Engine Low Idle 1200 (87.1 x 92.5mm) W / Built in Regulator
Bore x Stroke inch (mm)
3.43 X 3.64
(Group 34; 650
65 Amp Alternator
RATED OUTPUT @ 104° F (40° C) - WELDER
Welding Process
DC Constant Current
DC Pipe Current
Touch-Start™TIG
DC Constant Voltage
Arc Gouging
Welding Output
Current/Voltage/Duty Cycle
400A / 36V / 100%
450A / 38V / 60% 300A / 32V / 100% 250A / 30V / 100% 400A / 36V / 100%
450A / 38V / 60%
450A / 38V / 60%
Output Range
30 TO 500 AMPS
40 TO 300 AMPS 20 TO 250 AMPS
14 TO 40 VOLTS
90 TO 500 AMPS
RATED OUTPUT @ 40° C (104° F).- GENERATOR
Auxiliary Power
16,500 Watts Peak / 14,500 Watts Continuous, 50 Hz 400 Volts 3-Phase (Euro/UK)
6,900 Watts Peak
3,400 Watts Peak 3,400 Watts Peak
(3)
/ 6,900 Watts Continuous, 50 Hz 230 Volts 1-Phase (Euro)
(3)
/ 3,400 Watts Continuous, 50 Hz 230 Volts 1-Phase (UK)
(3)
/ 3,400 Watts Continuous, 50 Hz 115 Volts 1-Phase (UK)
Sound Levels (Sound power: 96 dB Lwa)
(1)
8.45Qts. (8L) (57 L)
Fuel: 15 gal.
Radiator
Coolant:
Fuel: 20 gal.
(75.7 L)
9.5 Qts. (9.0L)
Max. Weld OCV
@Rated Load RPM
60 Volts
(2)
60 Volts
ENGINE
LUBRICATION EMISSIONS FUEL SYSTEM GOVERNOR
Full Pressure with Full Flow Filter
(Codes 11298, 11299) EPA Tier Il
(Codes 11524, 11525, 11574, 11575) EPA Tier IV Interim Compliant
system, Electric shutoff solenoid, Indirect fuel injector.
Mechanical Fuel Pump, Auto air bleed Electronic
AIR CLEANER ENGINE IDLER MUFFLER ENGINE PROTECTION
Low noise Muffler: Shutdown on low oil
Single Element Automatic Idler Top outlet can be rotated. pressure & high engine
Made from long life, aluminized steel. coolant temperature
ENGINE WARRANTY:
2 years / 2000 hours, all non-electric components, 3 years major non-electric components. See Perkins warranty for details.
PHYSICAL DIMENSIONS
HEIGHT WIDTH DEPTH WEIGHT
(4)
35.94
913 mm 687 mm 1590 mm
(1) Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity.
When welding, available auxiliary power will be reduced.
(2) Reduced to less than (32V for Codes 11298, 11299
VRD (VOLTAGE REDUCTION DEVICE) is on.
(3) Maximum per circuit breaker rating.
(4) To Top of enclosure. Add 7.35 (186.7mm) to top of exhaust. Add 3.87”(98.3mm) to top of Lift Bail.
in. 27.05 in 62.59 in.
),
(30V for Codes 11524, 11525, 11574, 11575)in the CC-stick Mode when
1290 lbs. (586kg.)
VANTAGE®500 (CE)
A-2
MODEL NUMBERS K2503-1, -3 (UK) K2503-2, -4 (EUROPE)
Receptacles
Residual Current Device (RCD)
Circuit Breakers (Thermal/Magnetic)
Other Circuit Breakers
(5) Center-Tapped to ground.
INSTALLATION
MACHINE SPECIFICATIONS
400V (3 Ph) x 1 230V (1 Ph) x 1
115V x 1
14 Pin Connector
6 Pin Connector
4-pole, 25Amp
(30mA trip current)
3 Phase,25 Amp x 1
1 phase, 15 Amp x 1 for 230V
30 Amp x 2 for 115V
(5)
10A for Engine Battery Charging Circuit
10A for Wire Feeder Power
A-2
400V (3 Ph) x 1 230V (1 Ph) x 2
14 Pin Connector
6 Pin Connector
4-pole, 25Amp
(30mA trip current)
3 Phase,25 Amp x 1
1 phase, 15 Amp x 2
VANTAGE®500 (CE)
A-3
(
VRD)-VOLTAGE REDUCTION DEVICE
S
WITCH IS LOCATED IN THIS AREA.
REMOVE 4 FRONT PANEL SCREWS TO ACCESS (
VRD) SWITCH
INSTALLATION
A-3
SAFETY PRECAUTIONS
WARNING
Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or electrode with skin or wet clothing.
• Insulate yourself from work and ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
• Do not operate with doors open or guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information at
front of this operator’s manual.
Only qualified personnel should install, use, or service this equipment.
VRD (VOLTAGE REDUCTION DEVICE)
The VRD feature provides additional safety in the CC-Stick mode especially in an environment with a higher risk of electric shock such as wet areas and hot humid sweaty conditions.
The VRD reduces the OCV (Open Circuit Voltage) at the welding output terminals while not welding to less than 32V for (Codes 11298, 11299), 30V for(Codes 11524, 11525
, 11574, 11575)
put circuit is above 200 ohms.
DC when the resistance of the out-
FIGURE A.1
LOCATION AND VENTILATION
The welder should be located to provide an unrestrict­ed flow of clean, cool air to the cooling air inlets and to avoid restricting the cooling air outlets. Also, locate the welder so that the engine exhaust fumes are prop­erly vented to an outside area.
STACKING
VANTAGE® 500 (CE) machines cannot be stacked.
ANGLE OF OPERATION
Engines are designed to run in the level condition which is where the optimum performance is achieved. The maximum angle of continuous operation is 25 degrees in all directions, 35 degrees Intermittent (less than 10 minutes continuous) in all directions. If the engine is to be operated at an angle, provisions must be made for checking and maintaining the oil level at the normal (FULL) oil capacity in the crankcase.
The VRD requires that the welding cable connections be kept in good electrical condition because poor connections will contribute to poor starting. Having good electrical con­nections also limits the possibility of other safety issues such as heat-generated damage, burns and fires.
The machine is shipped with the VRD switch in the “Off” position. To turn it “On” or “Off”:
• Turn the engine “Off”.
• Disconnect the negative battery cable.
• Lower the control panel by removing 4 front panel screws.
• Place the VRD switch in the “On or “Off” position. (See Figure A.1)
With the VRD switch in the “On” position, the VRD lights are enabled.
(See Figure A.1)
VANTAGE®500 (CE)
When operating the welder at an angle, the effective fuel capacity will be slightly less than the amount specified.
LIFTING
The VANTAGE® 500 (CE) weighs approximately
1405 lbs.(63 8kg.) f o r (Codes 11298, 11299), 1440 lbs.(653kg.) for (Codes 11524, 11525, 11574,
11575) with a full tank of fuel 1290lbs. (586kg) less fuel. A lift bail is mounted to the machine and should always be used when lifting the machine.
A-4
INSTALLATION
WARNING
• Lift only with equipment of ade­quate lifting capacity.
• Be sure machine is stable when lift­ing.
• Do not lift this machine using lift bail if it is equipped with a heavy accessory such as trailer or gas cylinder.
FALLING • Do not lift machine if lift bail is
EQUIPMENT can damaged.
cause injury. • Do not operate machine while
suspended from lift bail.
------------------------------------------------------------------------
HIGH ALTITUDE OPERATION
At higher altitudes, output derating may be necessary. For maximum rating, derate the machine 1.0% for every 2000 ft. (610m) up to 6000 ft. (1828m) and 2.0% for every 2000 ft. (610m) over 6000 ft. (1828m). Due to new EPA and other local emissions regulations, modifications to the engine for high altitude are restricted within the United States. If required contact an authorized Perkins engine field service shop to determine if any adjustments can be made for oper­ation in higher elevations.
HIGH TEMPERATURE OPERATION
At temperatures above 104°F(40°C), Welder output derating is necessary. For maximum output ratings, derate the welder o utput 2 vo l ts for ev e r y 18°F(10°C ) above 104°F(40°C).
A-4
1. Design capacity of trailer vs. weight of Lincoln equipment and likely additional attachments.
2. Proper support of, and attachment to, the base of the welding equipment so there will be no undue stress to the framework.
3. Proper placement of the equipment on the trailer to insure stability side to side and front to back when being moved and when standing by itself while being operated or serviced.
4. Typical conditions of use, i.e., travel speed; roughness of sur­face on which the trailer will be operated; environmental con­ditions; like maintenance.
5. Conformance with federal, state and local laws.
(1) Consult applicable federal, state and local laws regarding specific requirements for use on public
highways.
(1)
VEHICLE MOUNTING
WARNING
Improperly mounted concentrated loads may cause unstable vehicle handling and tires or other components to fail.
• Only transport this Equipment on serviceable vehicles which are rated and designed for such loads.
• Distribute, balance and secure loads so vehicle is stable under conditions of use.
• Do not exceed maximum rated loads for compo­nents such as suspension, axles and tires.
• Mount equipment base to metal bed or frame of vehicle.
• Follow vehicle manufacturer’s instructions.
------------------------------------------------------------------------
Cold weather starting:
With a fully charged battery and the proper oil, the engine should start satisfactorily down to -15°F(­26C°). If the engine must be frequently started at or below 0°F (-18°C), it may be desirable to install cold­starting aides. The use of No. 1D diesel fuel is recom­mended in place of No. 2D at temperatures below 23°F (-5°C). Allow the engine to warm up before applying a load or switching to high idle.
Note: Extreme cold weather starting may require longer glow plug operation.
WARNING
Under no conditions should ether or other starting fluids be used with this engine!
------------------------------------------------------------------------
TOWING
Use a recommended trailer for use with this equipment for road, in-plant and yard towing by a vehicle(1). If the user adapts a non-Lincoln trailer, he must assume responsibility that the method of attachment and usage does not result in a safety hazard or damage the welding equipment. Some of the factors to be considered are as follows:
PRE-OPERATION ENGINE SERVICE
READ the engine operating and maintenance instruc­tions supplied with this machine.
WARNING
• Stop engine and allow to cool before fueling
• Do not smoke when fueling.
• Fill fuel tank at a moderate rate and do not over­fill.
• Wipe up spilled fuel and allow fumes to clear before starting engine.
• Keep sparks and flame away from tank.
------------------------------------------------------------------------
VANTAGE®500 (CE)
A-5
INSTALLATION
A-5
OIL
The VANTAGE® 500 (CE) is shipped with the engine crankcase filled with high quality SAE 10W-30 Oil that meets classification CG­4 or CH-4 for diesel engines. Check the oil level before starting the engine. If it is not up to the full mark on the dip stick, add oil as required. Check the oil level every four hours of running time during the first 50 running hours. Refer to the engine Operator’s Manual for specific oil recommendations and break-in information. The oil change interval is dependent on the quality of the oil and the operat­ing environment. Refer to the Engine Operator’s Manual for more
details on the proper service and maintenance intervals.
FUEL
DIESEL FUEL ONLY-Low sulphur fuel or ultra low sulphur
fuel in U.S.A. and Canada.
WARNING
• Fill the fuel tank with clean, fresh fuel. The capacity of the tank is 15 gals. (57 ltrs) for (Codes 11298, 11299), 20 gals. (75.5) for (Codes 11524, 11525, 11574, 11575). When the fuel gauge reads empty the tank contains approximately 2 gals. (7.6ltrs.) of reserve fuel.
NOTE: A fuel shut off valv e is located on the pre-fil-
ter/sediment filter. Which should be in the closed posi­tion when the welder is not used for extended periods of time.
------------------------------------------------------------------------
ENGINE COOLING SYSTEM
WARNING
MUFFLER OUTLET PIPE
Using the clamp provided secure the outlet pipe to the outlet tube with the pipe positioned such that it will direct the exhaust in the desired direction. Tighten using a 9/16"(14mm) socket or wrench.
SPARK ARRESTER
Some federal, state or local laws may require that gasoline or diesel engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this welder does not qualify as a spark arrester. When required by local regulations, a suitable spark arrester, such as the K903-1 must be installed and properly maintained.
WARNING
An incorrect spark arrestor may lead to damage to the engine or adversely affect performance.
------------------------------------------------------------------------
REMOTE CONTROL
The VANTAGE® 500 (CE) is equipped with a 6-pin and a 14-pin connector. The 6-pin connector is for connecting the K857 or K857­1 Remote Control or for TIG welding, the K870 foot Amptrol or the K936-3 hand Amptrol. When in the CC-STICK, ARC GOUGING or CV-WIRE modes and when a remote control is connected to the 6­pin Connector, the auto-sensing circuit automatically switches the OUTPUT control from control at the welder to remote control.
When in the DOWNHILL PIPE mode and when REMOTE CON­TROL is connected to the 6-Pin or 14-Pin Connector, the OUTPUT CONTROL is used to set the maximum current range of the OUT­PUT CONTROL of the REMOTE.
Air to cool the engine is drawn in the side and exhausted through radiator & case back. It is important that the intake and exhaust air is not restricted. Allow a minimum clearance of 1ft. (0.6m) from the case back and 16 in. (406mm) from either side of the base to a vertical surface.
------------------------------------------------------------------------
CAUTION
BATTERY CONNECTION
Use caution as the electrolyte is a strong acid that can burn skin and damage eyes.
------------------------------------------------------------------------
The VANTAGE® 500 (CE) is shipped with the negative battery cable disconnected. Make certain that the RUN-STOP switch is in the STOP position. Remove the two screws from the battery tray using a screwdriver or a 3/8"(10mm) socket. Attach the negative battery cable to the negative battery terminal and tighten using a 1/2"(13mm) socket or wrench.
NOTE: This machine is furnished with a wet charged battery; if unused for several months, the battery may require a booster charge. Be careful to charge the battery with the correct polarity. (See Battery in “Maintenance Section”)
Example: When the OUTPUT CONTROL on the welder is set to 200 amps the current range on the REMOTE CONTROL will be 40­200 amps rather than the full 40-300 amps. Any current range that is less than the full range provides finer current resolution for more fine tuning of the output.
When in TOUCH START TIG mode and when a Amptrol is connect­ed to the 6-Pin Connector, the OUTPUT dial is used to set the maxi­mum current range of the CURRENT CONTROL of the Amptrol.
The 14-pin connector is used to directly connect a wire feeder con­trol cable. In the CV-WIRE mode, when the control cable is con­nected to the 14-pin connector, the auto-sensing circuit automatical­ly makes the Output Control inactive and the wire feeder voltage control active.
WARNING
NOTE: When a wire feeder with a built in welding voltage con­trol is connected to the 14-pin connector, do not connect any­thing to the 6-pin connector.
------------------------------------------------------------------------
VANTAGE®500 (CE)
Loading...
+ 35 hidden pages