Lincoln Electric IM687 User Manual

RETURN TO MAIN INDEX
Square Wave TIG 175 PRO
IM687
February, 2002
For use with machines having Code Numbers:
Safety Depends on You
Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT
INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
10732 10733
Date of Purchase: Serial Number: Code Number: Model: Where Purchased:
OPERATOR’S MANUAL
Copyright © 2002 Lincoln Global Inc.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
i
SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
For
For Diesel Engines: Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
Gasoline Engines: The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
i
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
1.b.Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame weld-
ing arc or when the engine is running. Stop the engine and allow it to cool before refuel­ing to prevent spilled fuel from vaporizing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in posi­tion and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.
___________________________________________________
1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND MAGNETIC FIELDS may be dangerous
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
SQUARE WAVE TIG 175 PRO
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Mar ‘95
ii
SAFETY
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
5.b.
Do not weld in locations near chlorinated hydrocarbon coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors form phosgene, a highly toxic gas, and other irritating products.
5.c. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
5.d. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.
vapors
to
5.e. Also see item 1.b.
Mar ‘95
SQUARE WAVE TIG 175 PRO
iii
SAFETY
iii
WELDING SPARKS can cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even been “cleaned”. For information, purchase “Recommended Safe Practices for the Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f. free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
Remember that welding sparks and hot
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode if damaged.
7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.
Mar ‘95
SQUARE WAVE TIG 175 PRO
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv­antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher met­allique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble de
soudage et la machine à souder en bon et sûr état defonc­tionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à soud­er parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions pour le porte-électrode s’applicuent aussi au pistolet de soudage.
zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de la masse. Un court-circuit accidental peut provoquer un échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible de la zone de travail qu’il est pratique de le faire. Si on place la masse sur la charpente de la construction ou d’autres endroits éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de levage, câbles de grue, ou autres circuits. Cela peut provoquer des risques d’incendie ou d’echauffement des chaines et des câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage. Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant d’opérations de dégraissage, nettoyage ou pistolage. La chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas fortement toxique) ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA Standard W 117.2-1974.
2. Dans le cas de travail au dessus du niveau du sol, se protéger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de n’importe quelle partie du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel, donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray­onnement de l’arc et des projections quand on soude ou quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de l‘arc.
c. Protéger l’autre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de l’arc de soudage. Se protéger avec des vêtements de protection libres de l’huile, tels que les gants en cuir, chemise épaisse, pan­talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les
PRÉCAUTIONS DE SÛRETÉ POUR LES MACHINES À SOUDER À TRANSFORMATEUR ET À REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de l’électricité et aux recommendations du fabricant. Le dispositif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch­er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
Mar. ‘93
SQUARE WAVE TIG 175 PRO
for selecting a QUALITY product by Lincoln Electric. We want you
Thank You
to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you!
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Model Name & Number _____________________________________
Code & Serial Number _____________________________________
Date of Purchase _____________________________________
Whenever you request replacement parts for or information on this equipment always supply the information you have recorded above.
vv
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
TABLE OF CONTENTS
Page
Installation ..........................................................................................................Section A
Technical Specifications ...............................................................................................A-1
Saftey Precautions
Select Suitable Location........................................................................................A-2
Grinding .................................................................................................................A-2
Stacking.................................................................................................................A-2
Lifting .....................................................................................................................A-2
Tilting .....................................................................................................................A-2
Enviromental Rating ..............................................................................................A-2
Machine Grounding and High F
Input Connections ........................................................................................................A-3
Input Reconnect Procedure .........................................................................................A-3
Output Connections .....................................................................................................A-4
Connections For Tig (GTAW) Welding............................................................A-4
Tig Torch Connections ....................................................................................A-4
Work Cable Connections ................................................................................A-4
Shielding Gas Connection ..............................................................................A-4
Remote Control Connection............................................................................A-5
Connections For Stick (SMAW) Welding .......................................................A-5
Stick Electrode Cable and Work Cable Connection .......................................A-5
.. ............................................................................................................................................... .A-2
REQUENCY INTERFERANCE PROTECTION ...................A-2,A-3
vivi
PERATION.........................................................................................................................................................Section B-1
O
Saftey Precautions.......................................................................................................B-1
Product Description......................................................................................................B-1
Included Equipment...............................................................................................B-1
GTAW (Tig Welding): ......................................................................................B-1
SMAW (Stick Welding):...................................................................................B-1
Installation and Startup: ..................................................................................B-1
Welding Capability.................................................................................................B-1
Controls and Settings ..........................................................................B-2 THRU B-3
Operating Steps.....................................................................................................B-3
Welding in Tig Mode .......................................................................................B-3
Remote Control Operation ..............................................................................B-3
Benefits of the square Wave Operation..........................................................B-3
Welding in Stick Mode ..........................................................................................B-4
Accessories
............................................................................................................................................... .......Section C
Optional Equipment .....................................................................................................C-1
Maintenance
......................................................................................................................................................Section D
Saftey Precautions.......................................................................................................D-1
Routine and Periodic Maintenance..............................................................................D-1
Troubleshooting
.............................................................................................................................................Section E
Saftey Precautions.......................................................................................................E-1
How To Use TroubleShooting Guide............................................................................E-1
Troubleshooting.................................................................................................E-2 to E-7
Diagrams
..............................................................................................................................................................Section F
Wiring Diagram 208/230 V Model...................................................................................................................F-1
Wiring Diagram 460/575 V Model...................................................................................................................F-2
Parts List................................................................................................................................................P373,P210,P66
A-1
INSTALLATION
TECHNICAL SPECIFICATIONS - SQUARE WAVE TIG 175 PR0 (K1478-3 & -4
INPUT - SINGLE PHASE ONLY
Standard
oltage
V
208/230/1/60 460/575/1/60
Duty Cycle
GTAW 25% Duty Cycle
40% Duty Cycle 60% Duty Cycle
100% Duty Cycle
Input Current at
Rated Output
59/53 AC/DC Stick & DC TIG - 72/65 AC TIG 27/22 AC/DC Stick & DC TIG - 33/27 AC TIG
RATED OUTPUT
Amps
150 125 110
90
V
olts at Rated Amperes
Code
Number
10732 10733
14.8 V AC/DC
14.5 V AC/DC
14.3 V AC/DC
14.1V AC/DC
A-1
SMAW 25% Duty Cycle
40% Duty Cycle 60% Duty Cycle
100% Duty Cycle
150 125 110
90
26.0 V AC/DC
25.0 V AC/DC
24.4 V AC/DC
23.6 V AC/DC
OUTPUT
Maximum Open
ype of Output
Output Current
Range
10-175 Amps
AC and DC
Circuit V
(STICK AND TIG)
AC OCV: 74 DC OCV: 59
oltage
RECOMMENDED INPUT WIRE AND FUSE SIZES
For AC/DC Stick and DC TIG Welding at
150A/25% Duty Cycle and for AC TIG Welding up
to 110A/25% Duty Cycle. Based on the 1996 U.S.
National Electrical Code
Type 75°C
Input
Voltage /
phase/
Frequency
208/1/60
230/1/60
460/1/60
575/1/60
(1)
The National Electrical Code permits operation at rated output and duty cycle from a 50 amp receptacle when supply lines and fuses are sized per this table.
Fuse
(Super Lag)
or Breaker
Size
100
100
50
40
Input
Ampere
Rating on
Nameplate
59
53
27
22
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
10 (5.2 mm2)
10 (5.2 mm2)
14 (2.1 mm2)
14 (2.1 mm2)
Copper
Ground Wire in
Conduit AWG
(IEC) Sizes
10 (5.2 mm2)
10 (5.2 mm2)
14 (2.1 mm2)
14 (2.1 mm2)
(Super Lag)
or Breaker
For AC TIG Welding at 150 A/25% Duty Cycle, Based on the 1996 U.S. National
Fuse
Size
125
125
60
50
Input
Ampere
Rating on
Nameplate
72
65
33
27
T
CC (Constant Current)
AC/DC
(1)
Electrical Code
Type 75°C
Copper Wire in
Conduit AWG
(IEC) Sizes
8 (8.2 mm2)
8 (8.2 mm2)
14 (2.1 mm2)
14 (2.1 mm2)
Type 75°C
Copper
Ground Wire in
Conduit AWG
(IEC) Sizes
8 (8.2 mm2)
8 (8.2 mm2)
14 (2.1 mm2)
14 (2.1 mm2)
PHYSICAL DIMENSIONS
Height Width Depth Weight
Power 19.53 in. 13.72 in. 24.94 in. Approx. 200 lbs. Source
Power Source 27.93 in. 19.22 in. 36.74 in. Approx. 230 lbs.
on
Undercarriage
496 mm 349 mm 633 mm 90.9 kgs.
709 mm 488 mm 933 mm 105 kgs.
SQUARE WAVE TIG 175 PRO
A-2
INSTALLATION
A-2
SAFETY PRECAUTIONS
Read entire installation section before starting installation.
WARNING
ELECTRIC SHOCK can kill.
Only qualified personnel should perform this installation.
• Turn the input power OFF at the disconnect switch or fuse box before working on this equipment.
• Do not touch electrically hot parts.
• Always connect the SQUARE WAVE TIG 175 PRO to a power supply grounded per the National Electrical Code and any local codes.
SELECT SUITABLE LOCATION
Place the welder where clean cooling air can freely cir­culate in through the rear louvers and out through the front and side louvers. Dirt, dust or any foreign mater­ial that can be drawn into the welder should be kept at a minimum. Failure to observe these precautions can result in excessive operating temperatures and nui­sance shut-downs.
GRINDING
Do not direct grinding particles towards the welder. An abundance of conductive material can cause mainte­nance problems.
MACHINE GROUNDING AND HIGH FRE­QUENCY INTERFERENCE PROTECTION
The welder must be grounded. See your local and national electrical codes for proper grounding methods.
The high frequency generator, being similar to a radio transmitter, can be blamed for radio, TV and electronic equipment interference problems. These problems may be the result of radiated interference. Proper grounding methods can reduce or eliminate radiated interference.
Radiated interference can develop in the following four ways:
1. Direct interference radiated from the welder.
2. Direct interference radiated from the welding leads.
3. Direct interference radiated from feedback into the power lines.
4. Interference from re-radiation of “pickup” by ungrounded metallic objects.
Keeping these contributing factors in mind, installing equipment per the following instructions should mini­mize problems.
STACKING
Square Wave TIG 175 PRO’s cannot
be stacked.
LIFTING AND MOVING
The Square Wave TIG 175 PRO should be lifted by two or more people or with a hoist. (It weighs approximate­ly 200 lbs./90.9 kg.) Its lifting handles are designed to
make lifting more convenient. An optional undercarriage is available
to easily move
the unit. Refer to the
Accessories section of this manual.
TILTING
Each machine must be placed on a secure, level sur­face, either directly or on a recommended undercar­riage. The machine may topple over if this procedure is not followed.
ENVIRONMENTAL RATING
The SQUARE WAVE TIG 175 PRO power source carries an IP21 environmental rating. It may be used in normal industri­al and commercial environments. Avoid using it in environ­ments which have falling water such as rain. Read and fol­low “Electric Shock Warnings” in the Safety section if weld­ing must be performed under electrically hazardous condi­tions such as welding in wet areas or on or in the workpiece.
1. Keep the welder power supply lines as short as pos­sible and enclose as much of them as possible in rigid metallic conduit or equivalent shielding for a distance of 50 feet (15.2m). There should be good electrical contact between this conduit and the welder case ground. Both ends of the conduit should be connected to a driven ground and the entire length should be continuous.
2. Keep the work and electrode leads as short as pos­sible and as close together as possible. Lengths should not exceed 25 ft (7.6m). Tape the leads together when practical.
3. Be sure the torch and work cable rubber coverings are free of cuts and cracks that allow high frequen­cy leakage.
4. Keep the torch in good repair and all connections tight to reduce high frequency leakage.
5. The work piece must be connected to an earth ground close to the work clamp, using one of the following methods:
SQUARE WAVE TIG 175 PRO
A-3
a) A metal underground water pipe in direct contact
with the earth for ten feet or more.
b) A 3/4” (19mm) galvanized pipe or a 5/8” (16mm)
solid galvanized iron, steel or copper rod driven at least eight feet into the ground.
INSTALLATION
A-3
INPUT RECONNECT PROCEDURE
On multiple input voltage welders, be sure the machine is connected per the following instructions for the volt­age being supplied to the welder.
CAUTION
The ground should be securely made and the ground­ing cable should be as short as possible using cable of the same size as the work cable, or larger. Grounding to the building frame electrical conduit or a long pipe system can result in re-radiation, effectively making these members radiating antennas.
6. Keep cover and all screws securely in place.
7. Electrical conductors within 50 ft (15.2m) of the welder should be enclosed in grounded rigid metal­lic conduit or equivalent shielding, wherever possi­ble. Flexible metallic conduit is generally not suit­able.
8. When the welder is enclosed in a metal building, the metal building should be connected to several good earth driven electrical grounds (as in 5 (b) above) around the periphery of the building.
Failure to observe these recommended installation procedures can cause radio or TV and electronic equipment interference problems and result in unsatis­factory welding performance resulting from lost high frequency power.
INPUT CONNECTIONS
Be sure the voltage, phase, and frequency of the input power is as specified on the rating plate, located on the rear of the machine.
208/230 volt models have a NEMA 6-50P plug attached to the input power cord and a NEMA 6-50R receptacle is included. Other voltage models have an input power cord but no plug or receptacle.
Failure to follow these instructions can cause immedi­ate failure of components within the welder.
___________________________________________
Multiple voltage models are shipped connected for the highest voltage. To change this connection refer to the following instructions.
WARNING
ELECTRIC SHOCK can kill.
• Turn the input power OFF at the disconnect switch or fuse box before working on this
For the lowest rated voltage connection (Refer to figure A.1):
1. Remove the sheet metal cover.
2. Disconnect lead H3 from the power switch and insu­late with the insulation from the H2 lead.
3. Connect lead H2 to the power switch where H3 was connected.
4. Tighten connections.
5. Replace sheet metal cover and all screws
For the highest rated voltage connection (Refer to figure A.1): The machine is normally shipped connected for the highest rated voltage, however verify the following:
equipment.
Have a qualified electrician provide input power supply to the receptacle or cord in accordance with all local and national electrical codes. Use a single phase line or one phase of a two or three phase line. Choose an input and grounding wire size according to local or national codes. Refer to the Technical Specifications page at the beginning of this section. Fuse the input circuit with the recommended super lag fuses or delay
1
type
circuit breakers. Using fuses or circuit breakers smaller than recommended may result in “nuisance” shut-offs from welder inrush currents even if not weld­ing at high currents.
1
Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magni­tude of the current increases.
SQUARE WAVE TIG 175 PRO
1. Remove the sheet metal cover.
2. Disconnect lead H2 from the power switch and insu­late with the insulation from the H3 lead.
3. Connect lead H3 to the line switch where H2 was connected.
4. Tighten connections.
5. Replace sheet metal cover and all screws.