Lincoln Electric IM10108 User Manual

Page 1
TELESCOPIC EXTRACTION ARM
RETURN TO MAIN MENU
Safety Depends on You
Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READ­ING THIS MANUAL AND THE SAFETY PRECAUTIONS CON­TAINED THROUGHOUT. And,
most importantly, think before you act and be careful.
LTA 2.0-CW
IM10108
OPERATORS MANUAL
Copyright © Lincoln Global Inc.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 888.935.3878 FAX: 216.383.8823
Page 2
i
SAFETY
i
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause can­cer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz­ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.
___________________________________________________
1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND MAGNETIC FIELDS may be dangerous
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Nev er coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Page 3
ii
SAFETY
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases. When welding, keep your head out of the fume. Use enough
fumes and gases away from the breathing zone. When
welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and within applicable OSHA PEL and ACGIH TLV limits using local exhaust or mechanical ventilation. In confined spaces or in some circum­stances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
5. b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the spe­cific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors form phosgene, a highly toxic gas, and other irritating prod­ucts.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
ventilation and/or exhaust at the arc to keep
vapors
to
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
Page 4
iii
SAFETY
iii
WELDING and CUTTING SPARKS can cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even been “cleaned”. For information, purchase “Recommended Safe Practices for the Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f. free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate cir­cuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
the welding sparks from starting a fire.
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode if damaged.
7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Refer to http://www.lincolnelectric.com/safety for additional safety information.
Page 5
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv­antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions pour le porte-électrode s’applicuent aussi au pistolet de soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de n’importe quelle partie du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel, donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray­onnement de l’arc et des projections quand on soude ou quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de l‘arc.
c. Protéger l’autre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de l’arc de soudage. Se protéger avec des vêtements de protection libres de l’huile, tels que les gants en cuir, chemise épaisse, pan­talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de la masse. Un court-circuit accidental peut provoquer un échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible de la zone de travail qu’il est pratique de le faire. Si on place la masse sur la charpente de la construction ou d’autres endroits éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de lev­age, câbles de grue, ou autres circuits. Cela peut provoquer des risques d’incendie ou d’echauffement des chaines et des câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage. Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant d’opérations de dégraissage, nettoyage ou pistolage. La chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas fortement toxique) ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA Standard W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR LES MACHINES À SOUDER À TRANSFORMATEUR ET À REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de l’électricité et aux recommendations du fabricant. Le dispositif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch­er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
Page 6
Thank You
ixix
for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip­ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses­sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor­mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customer’s particular purpose, with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.
CUSTOMER ASSISTANCE POLICY
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
“Product Registration”. Please complete the form and submit your registration.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
Page 7
TABLE OF CONTENTS
Page
Installation .......................................................................................................Section A
Technical Specifications ........................................................................................A-1
Components ..........................................................................................................A-2
Safety Precautions.................................................................................................A-2
Installation..............................................................................................................A-2
Use ........................................................................................................................A-2
Installation Height ..................................................................................................A-3
Tools And Requirements .......................................................................................A-3
Unpacking..............................................................................................................A-3
Mounting................................................................................................................A-3
Attaching The Rope...............................................................................................A-4
Attaching The Hose To The Rotating Hinge..........................................................A-5
Attaching The Hose And Extraction Hood .............................................................A-5
Mounting Of The Extraction Hood .........................................................................A-5
Operation .........................................................................................................Section B
General Description...............................................................................................B-1
Manual Operation ..................................................................................................B-1
User Manual ..........................................................................................................B-1
Users .....................................................................................................................B-1
Intended Use .........................................................................................................B-1
Product Combinations ...........................................................................................B-2
Controls .................................................................................................................B-2
xx
Accessories.....................................................................................................Section C
General Options / Accessories..............................................................................C-1
Product Combinations ...........................................................................................C-1
Options And Accessories ......................................................................................C-1
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
Disposal.................................................................................................................D-1
Service, Maintenance And Repairs .......................................................................D-1
Periodic Maintenance............................................................................................D-2
Major Components ................................................................................................D-2
Troubleshooting..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide ..........................................................................................E-2
Parts Manual.................................................................................................Section P-1
Page 8
A-1
TECHNICAL SPECIFICATIONS
MODEL DESCRIPTION
INSTALLATION
INPUT
A-1
K1655-7
LTA 2.0-CW™ AIR HANDLING
PHYSICAL DIMENSIONS
COUNTERWEIGHT DIAMETER WEIGHT
14.3 lbs. (6.5 kg) 8 in. (203mm) 59.5 lbs (27kg)
TEMPERATURE RANGE RELATIVE HUMIDITY
410F (50C) to 1130F (450C) MAX. 80%
UNRESTRICTED AIR FLOW
Max: 942 CFM (1600 m3/h)
FIGURE A.1 - STATIC PRESSURE
STATIC PRESSURE
A (Pa)
1600
FIGURE A.2 - REACH
1200
800
400
0
0 400 800 1200 1600
STATIC PRESSURE
C (in. WG)
8
6
4
2
0
0 250 500 750 1000
D (CFM)
AIRFLOW
2000
B (m
AIRFLOW
TOP VIEW
A
3
/h)
A
FRONT VIEW
B
B
inch mm A 61 1550 B 98 2500
LTA 2.0-CW™
Page 9
A-2
INSTALLATION
A-2
COMPONENTS
The product consists of the following main compo­nents and elements:
A. Wall mounting bracket B. Counterweight casing C. Rotatable hood D. Hose 65 in. (1650 mm) E. Tube F. Hose 20 in. (500 mm) G. Rotating hinge H. Rope I. Counterweight J. Rubber gaskets (4) K. Extension arm
*Hardware (not shown)
F
E
D
J
C
K
A
B
G
H
I
READ ENTIRE INSTALLATION SECTION BEFORE STARTING INSTALLATION.
SAFETY PRECAUTIONS
CAUTION
NEVER USE THIS PRODUCT FOR:
• Oil mist
• Paint mist
• Extraction of hot gases (more than 113 tinuously)
• Explosive environments or explosive substances/gases
NOTE: This list is not all inclusive.
INSTALLATION
• The installation of this product is exclusively reserved to well authorized, trained and qualified engineers.
• During installation, always use Personal Protective Equipment (PPE) to avoid injury. This also applies for persons who enter the work area during installa­tion.
• Use sufficient climbing gear and safety guards when working on a higher level than 78.74 inches (2 meters) (local restrictions may apply).
• Never install the product in front of entrances and exits which must be used for emergency services.
• Mind any gas and water pipes and electric cables.
• Make sure the wall, ceiling or support system are strong enough to carry the product.
• Ensure the workspace is well illuminated.
• Use common sense. Stay alert and keep your atten­tion to your work. Do not install the product when you are under the influence of drugs, alcohol or medi­cine.
• Make sure that the workshop, in the vicinity of the product, contains sufficient approved fire extinguish­ers.
• Air containing particles such as chromium, nickel, beryllium, cadmium, lead etc., which is a health haz­ard, should never be recycled. This air must always be brought outside the working area.
0
F/450C con-
WARNING
ELECTRIC SHOCK CAN KILL
Only qualified personnel should perform
this installation.
• Turn the input power OFF and unplug the machine from the receptacle before working on this equipment.
Insulate yourself from the work and ground.
• Always connect the grounded according to the National Electrical Code and local codes.
machine
to a power supply
LTA 2.0-CW™
USE
• Inspect the product and check it for damage. Verify the functioning of the safety features.
• During use, always use Personal Protective Equipment (PPE) to avoid injury. This also applies for persons who enter the work area.
• Check the working environment. Do not allow unau­thorized persons to enter the working environment.
• Protect the product against water and humidity.
• Make sure the room is always sufficiently ventilated; this applies especially to confined spaces.
Page 10
A-3
INSTALLATION
A-3
INSTALLATION HEIGHT
The recommended installation height of the wall mounting bracket is 11.5 ft. (3500 mm). If the subject work bench is lower than the standard height of 3.0 ft. (900 mm), it is advisable to install the wall mounting bracket at a height of 9.8-10.6 ft. (3000-3250 mm). See Figure A.3.
TOOLS AND REQUIREMENTS
The following tools are needed to install and maintain the extraction arm.
• 17mm wrench
• 13mm wrench
• 10mm wrench (2)
UNPACKING
Check that the product is complete. See Components in this section.
If parts are missing or damaged, contact your supplier.
MOUNTING
The package contains no mounting hardware for the wall mounting brackets since the required mounting hardware depends on the wall type. Wall mounting brackets can be mounted on:
• A thin brick or concrete wall (min. thickness of 4 inches/100 mm), using four threaded rods M10.
NOTE: For this purpose, two square tubes
(30x30x3mm) need to be mounted to prevent bending.
NOTE: For central extraction systems, a tapered fan
flange is required.
CAUTION
USE CAUTION WHEN MOUNTING
• Check that the wall composition is strong enough before mounting the wall brackets.
• Before drilling,verify locations of existing gas, water and electrical conduits.
• Mount the wall mounting bracket to the wall.
A
B
A B C
inch
mm
8.3 210
5.9 150
0.5 12
• A thick brick or concrete wall, using four cotter bolts M10x120x60.
• Steel profile (e.g. H-profile), using four threaded rods M10.
FIGURE A.3 - INSTALLATION HEIGHT
30°
A
TOTAL HEIGHT
C
DF
B
WORK BENCH
HEIGHT
C (x4)
mm inch feet
3500 138.8 11.5
45°
G
E
A
900 35.4 3
B
450 17.7 1.5
C
1250 49.2 4.1
D
100 4.0 0.3
E
1800 70.9 5.9
F
800 31.5 2.6
G
LTA 2.0-CW™
Page 11
A-4
INSTALLATION
A-4
ATTACHING THE ROPE
• Pull the arm to the longest position.
• Guide the rope through the rotating hinge (D) and over the pulley (C), the counterweight pulley (B) and the other small pulley (A).
• Keep the counterweight in the highest position, which means just below the small pulleys. Securely fasten the rope to the counterweight by tying a knot (E). The rope should be threaded through the hole in the counterweight pulley. The knot must be large enough so the rope cannot slip back through the hole.
CAUTION
• Tying the counterweight too low will affect the reach of the extraction arm.
A BC D
ATTACHING THE COUNTERWEIGHT CASING
• Slide the counterweight casing (C) over the counter­weight.
• Using a 13mm wrench, fasten the casing to the wall mounting bracket (A) using 2 bolts M8x10 and 2 lock washers M8 (B).
• Securely tighten bolts.
A
B
C
E
LTA 2.0-CW™
Page 12
A-5
INSTALLATION
A-5
ATTACHING THE HOSE TO THE ROTATING HINGE
The rotating hinge and the tube are both provided with a rubber gaskets. To attach the shorter flexible hose proceed as follows:
• Remove the banding straps from the flexible hose.
• Fold back 2/3 of both rubber gaskets. (A+D).
• Place the flexible hose (C) over the collar (B) and the tube (E). To secure the hose, at least one metal ring of the hose should be applied over the ridges of the collar. The same goes for the tube.
• Fold back the gaskets and place them over the hose. Make sure the upper gasket overlaps the alu­minum rotating hinge approximately 0.4 in. (10 mm).
A
B
C
D
E
ATTACHING THE HOSE AND EXTRAC­TION HOOD
To mount the 65 in. (1650 mm) hose and the extrac­tion hood, proceed as follows:
• Make sure the extraction arm is fully extended.
• Place a rubber gasket over the tube and fold back 2/3.
• Place the flexible hose 65 in. (1650 mm) over the tube. To secure the hose, at least one metal ring of the hose should be applied over ridges of the tube.
• Fold back the gasket and place it over the hose.
MOUNTING OF THE EXTRACTION HOOD
• Place a gasket over the extraction hood and fold back 2/3.
• Mount the extraction hood to the extraction arm using a bolt M6x40, a nut M6 and 2 washers M6. Tighten using two 10mm wrenches.
• Place the flexible hose over the extraction hood. To secure the hose, at least one metal ring of the hose should be applied over the ridges of the hood.
• Fold back the rubber gasket and place it over the
hose.
LTA 2.0-CW™
Page 13
B-1
OPERATION
B-1
GENERAL DESCRIPTION
The LTA 2.0-CW™ is a wall-mounted telescopic extraction arm with a rotatable hood. Located in the hood is a throttle valve that can be fully opened, par­tially opened or completely closed to control airflow. The arm features a focus extraction spoiler which directs the air into the hood. The extraction arm is based on a telescopic tube, allowing it to be extended to give a 8.2 ft (2.5 m) working radius and com­pressed to 5 ft (1.5 m). The arm is fitted with a spring balance which enables it to be moved from a vertical to a horizontal position in one easy movement. If mounted on a column, the arm can be turned 300° due to the rotating hinge. The LTA 2.0-CW™ is often used in welding booths.
MANUAL OPERATION
The extracted welding fume enters the extraction arm via the rotatable hood. The arm discharges the pollut­ed air to a filter unit or directly to the atmosphere. The hood of the arm is fitted with a throttle valve, which can be controlled using the rotary knob(s). The throttle valve is mostly used when several extraction arms are integrated in a line installation; in such configurations closing the throttle valve prevents the loss of costly
heated air.
NOTE: If an automatic damper system is part of the
assembly, keep the manual damper open at all times.
WARNING
ELECTRIC SHOCK CAN KILL
The manufacturer does not accept any liability for damage to the product or personal injury caused by ignoring the safety instructions in this manual, or by negligence during installation, use, mainte­nance, and repair of the product mentioned on the cover of this document and any correspond­ing accessories. Specific working conditions or used accessories may require additional safety instructions. Immediately contact your supplier if you detect a potential danger when using the product.
USER MANUAL
• Everyone working on or with the product, must be familiar with the contents of this manual and must strictly observe the instructions therein. The man­agement should instruct the personnel in accor­dance with the manual and observe all instructions and directions given.
• Never change the order of the steps to perform.
• Always keep the manual with the product.
USERS
• The use of this product is exclusively reserved to well authorized, trained and qualified users. Temporary personnel and personnel in training can only use the product under supervision and respon­sibility of skilled engineers.
• Use common sense. Stay alert and keep your atten­tion on your work. Do not use the product when you are under the influence of drugs, alcohol or medi­cine.
• The product is not to be used by children or persons with reduced physical, sensory or mental capabili­ties, or lack of experience and knowledge.
INTENDED USE
This product has been designed exclusively for extracting gases and particles which are released during the most common welding processes. Using this product for other purposes is considered contrary to its intended use. The manufacturer accepts no lia­bility for any damage or injury resulting from such use. The product has been built in accordance with state-of-the art standards and recognized safety regu-
lations. Only use this product when in technically per­fect condition in accordance with its intended use and the instructions explained in the user manual.
The user of the product is always fully responsi­ble for observing the local safety instructions and regulations. Observe all applicable safety instruc­tions and regulations.
LTA 2.0-CW™
Page 14
B-2
OPERATION
B-2
PRODUCT COMBINATIONS
If the product is used in combination with other prod­ucts or machines, the safety instructions in the docu­mentation of these products also apply.
WARNING
RISK OF FIRE
NEVER USE THE PRODUCT FOR:
• Extracting flammable, glowing or burning particles or solids or liquids.
• Extracting of aggressive fumes (such as hydrochloric acid) or sharp parti­cles.
• Extracting dust particles which are released when welding surfaces treated with primer.
• Smoking cigarettes, cigars, oiled tissues, and other burning particles, objects, and acids.
WARNING
• Always use Personal Protective Equipment (PPE) to avoid injury. This also applies for persons who enter the work area.
------------------------------------------------------------------------
• Using the handle (B), position the hood of the extrac­tion arm in the desired position at approximately 6­20 inches (15-50 cm) from the source of fume.
NOTE: Retraction movement must happen slowly to
allow counterweight to descend.
• Open the throttle valve (A).
• Turn on the connected extraction fan; refer to the corresponding manual.
• Start welding.
• If desired, adjust the airflow by turning the rotary knob of the throttle valve (A).
NOTE: If an automatic damper system is part of the
assembly, keep the manual damper open at all times.
• Turn off the connected extraction fan approx. 20 sec­onds after finishing welding; refer to the correspond­ing manual.
CONTROLS
The LTA 2.0-CW™ is provided with a handle for easy positioning and a throttle valve for adjustment of the airflow. All movement of the arm is controlled from the hood.
A. Rotary knobs for adjustment of throttle valve. B. Handle for positioning of the extraction arm and
hood.
FIGURE B.1 - CONTROLS
B
A
LTA 2.0-CW™
Page 15
C-1
ACCESSORIES
GENERAL OPTIONS / ACCESSORIES
PRODUCT COMBINATIONS
In order to operate the extraction arm, selection of one of the following products is required:
• Single fan type SF 1400 + wall bracket type TMB.
• Single fan type FAN 2400 + wall bracket type TMB.
• Single fan type FAN 4200.
• Central fan +NCF (flange).
OPTIONS AND ACCESSORIES
The following products can be obtained as an option and/or accessory:
C-1
• WCS (welding cable sensor) + AD-200 or AD-8. (automatic damper)
• NCF (flange in case of duct connection).
• Lamp kit for wall mounted systems (K1669-1).
See IM627
• Automatic start/stop arc sensor (K1670-1).
See IM628
LTA 2.0-CW™
Page 16
D-1
MAINTENANCE
D-1
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or electrode with skin or wet clothing.
• Insulate yourself from work and ground.
• Always wear dry insulating gloves.
------------------------------------------------------------------------
MOVING PARTS can injure.
Do not operate with doors open or guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
DISPOSAL
After life of the product, dispose of it in accordance with federal, state and local regulations.
SERVICE, MAINTENANCE AND REPAIRS
• Observe the maintenance intervals given in this manual. Overdue maintenance can lead to high costs for repair and can render the guarantee null and void.
• During service, maintenance and repair jobs, always use Personal Protective Equipment (PPE) to avoid injury. This also applies for persons who enter the work area.
• Always use tools, materials, lubricants and service techniques which have been approved by the manu­facturer. Never use worn tools and do not leave any tools in or on the product.
• Safety features which have been removed for ser­vice, maintenance or repairs, must be put back immediately after finishing these jobs and it must be checked that they will still function properly.
• Use sufficient climbing gear and safety guards when working higher than 2 meters (local restrictions may apply).
• Ensure the workspace is well illuminated.
The product has been designed to function without problems for a long time with a minimum amount of maintenance. In order to guarantee this, some simple regular maintenance and cleaning activities are required which are described in this chapter. If you observe the necessary caution and carry out the maintenance at regular intervals, any problems occur­ring will be detected and corrected before they lead to a total breakdown. The indicated maintenance inter­vals can vary depending on the specific working and ambient conditions. Therefore it is recommended to thoroughly inspect the complete product once every year beside the indicated periodic maintenance. For this purpose contact your supplier. See Table D.1.
WARNING
RISK OF FIRE
PAST DUE MAINTENANCE CAN CAUSE FIRE.
------------------------------------------------------------------------
LTA 2.0-CW™
Page 17
D-2
MAINTENANCE
TABLE D.1 - PERIODIC MAINTENANCE
D-2
COMPONENT
Outside Arm Flexible Hoses
Inside Arm Arm Movement
Rotatable Arm
ACTION
Check and clean with a non-aggressive detergent. Check for cracks or damages. Replace if necessary.
Check and clean thoroughly. Check horizontal, vertical and diagonal arm
movement. If necessary, adjust the spring and friction.
See Figure F.2.
Check the function of the hood hinge. If necessary, adjust the friction. See Figure F.1.
Check the function of the throttle valve. See Figure B.1.
TABLE D.1 - MAJOR COMPONENTS
FREQUENCY
Every 3 mo.XEvery 6 mo.
X X
X
X X
LTA 2.0-CW™
Page 18
F-1
TROUBLESHOOTING
HOW TO USE TROUBLESHOOTING GUIDE
WARNING
Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.
__________________________________________________________________________
F-1
This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled “PROBLEM (SYMP­TOMS)”. This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting.
Step 2. POSSIBLE CAUSE.
The second column labeled “POSSIBLE CAUSE” lists the obvious external possibilities that may contribute to the symptom.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the Possible Cause.
If you do not understand or are unable to perform the Recommended Course of Action safely, contact the Lincoln Electric Automation Division at 888.935.3878
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Automation Division at 888.935.3878 for technical troubleshooting assistance before you
proceed.
LTA 2.0-CW™
Page 19
F-2
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
TROUBLESHOOTING
POSSIBLE
CAUSE
F-2
RECOMMENDED
COURSE OF ACTION
Rotatable hood does not stay in desired position or does not move with reasonable force.
Arm does not stay in desired hori­zontal/vertical/diagonal position or does not move with reasonable force.
Arm does not stay in retracted posi­tion.
Poor suction.
FIGURE F.1 - HOOD ADJUSTMENT
Too much or not enough friction in hood hinge.
1. Spring loose.
2. Too much or not enough friction in arm.
1. Counterweight gets stuck.
2. Rope broken.
1. Throttle valve closed.
2. Flexible hose(s) torn or loose.
3. Gasket(s) damaged or loose.
4. Fan.
5. Obstruction of air flow
FIGURE F.2 - ARM ADJUSTMENT
Adjust friction. See Figure F.1. A = vertical movement
B = horizontal movement
1. Tighten spring. See Figure F.2.
2. Adjust friction. See Figure F.2.
1. Extend the arm and retract it again slowly.
2. Replace rope.
1. Open throttle valve.
2. Mount correctly or replace.
3. Mount correctly or replace.
4. Check source.
5. Remove.
A
B
A
13
B
17
13
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Automation Division at 888.935.3878 for technical troubleshooting assistance before you
proceed.
LTA 2.0-CW™
Page 20
WARNING
Spanish
AVISO DE
PRECAUCION
Do not touch electrically live parts or electrode with skin or wet clothing.
Insulate yourself from work and ground.
No toque las partes o los electrodos bajo carga con la piel o ropa moja­da.
Aislese del trabajo y de la tierra.
Keep flammable materials away.
Mantenga el material combustible fuera del área de trabajo.
Wear eye, ear and body protection.
Protéjase los ojos, los oídos y el cuerpo.
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
Japanese
Chinese
Korean
Arabic
Ne laissez ni la peau ni des vête­ments mouillés entrer en contact avec des pièces sous tension.
Isolez-vous du travail et de la terre.
Berühren Sie keine stromführenden Teile oder Elektroden mit Ihrem Körper oder feuchter Kleidung!
Isolieren Sie sich von den Elektroden und dem Erdboden!
Não toque partes elétricas e electro­dos com a pele ou roupa molhada.
Isole-se da peça e terra.
Gardez à l’écart de tout matériel inflammable.
Entfernen Sie brennbarres Material!
Mantenha inflamáveis bem guarda­dos.
Protégez vos yeux, vos oreilles et votre corps.
Tragen Sie Augen-, Ohren- und Kör­perschutz!
Use proteção para a vista, ouvido e corpo.
READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.
LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.
LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRO­DENEINSATZ DES HERSTELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.
Page 21
Keep your head out of fumes.
Use ventilation or exhaust to remove fumes from breathing zone.
Turn power off before servicing.
Do not operate with panel open or guards off.
WARNING
Los humos fuera de la zona de res­piración.
Mantenga la cabeza fuera de los humos. Utilice ventilación o aspiración para gases.
Gardez la tête à l’écart des fumées.
Utilisez un ventilateur ou un aspira­teur pour ôter les fumées des zones de travail.
Vermeiden Sie das Einatmen von Schweibrauch!
Sorgen Sie für gute Be- und Entlüftung des Arbeitsplatzes!
Mantenha seu rosto da fumaça.
Use ventilação e exhaustão para remover fumo da zona respiratória.
Desconectar el cable de ali­mentación de poder de la máquina antes de iniciar cualquier servicio.
Débranchez le courant avant l’entre­tien.
Strom vor Wartungsarbeiten abschalten! (Netzstrom völlig öffnen; Maschine anhalten!)
Não opere com as tampas removidas.
Desligue a corrente antes de fazer serviço.
Não toque as partes elétricas nuas.
No operar con panel abierto o guardas quitadas.
N’opérez pas avec les panneaux ouverts ou avec les dispositifs de protection enlevés.
Anlage nie ohne Schutzgehäuse oder Innenschutzverkleidung in Betrieb setzen!
Mantenha-se afastado das partes moventes.
Não opere com os paineis abertos ou guardas removidas.
Spanish
AVISO DE
PRECAUCION
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
Japanese
Chinese
Korean
Arabic
LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
Page 22
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 888.935.3878 FAX: 216.383.8823
Loading...