Lincoln Electric IM10017 User Manual

Operator’s Manual
RETURN TO MAIN MENU
RANGER ® 225
For use with machines having Code Numbers:
11597, 11734, 11790, 11797, 12093, 12199
Register your machine:
www.lincolnelectric.com/register
Authorized Service and Distributor Locator:
www.lincolnelectric.com/locator
Save for future reference
Date Purchased
Code: (ex: 10859)
Serial: (ex: U1060512345)
© Lincoln Global, Inc. All Rights Reserved.
Need Help? Call 1.888.935.3877
to talk to a Service Representative
Hours of Operation:
8:00 AM to 6:00 PM (ET) Mon. thru Fri.
After hours?
Use “Ask the Experts” at lincolnelectric.com A Lincoln Service Representative will contact you no later than the following business day.
For Service outside the USA:
Email: globalservice@lincolnelectric.com
THANK YOU FOR SELECTING
AT ALL
TIMES.
SPECIAL SITUATIONS
Additional precautionary measures
A QUALITY PRODUCT BY LINCOLN ELEC TRIC.
PLEASE EXAMINE CARTON AND EQUIPMENT FOR DAMAGE IMMEDIATELY
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
SAFETY DEPENDS ON YOU
Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly, think before you
act and be careful.
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
KEEP YOUR HEAD OUT OF THE FUMES.
DON’T get too close to the arc. Use
corrective lenses if necessary to stay a reasonable distance away from the arc.
READ and obey the Material Safety
Data Sheet (MSDS) and the warning label that appears on all containers of welding materials.
USE ENOUGH VENTILATION or
exhaust at the arc, or both, to keep the fumes and gases from your breathing zone and the general area.
IN A LARGE ROOM OR OUTDOORS, natural ventilation may be
adequate if you keep your head out of the fumes (See below).
USE NATURAL DRAFTS or fans to keep the fumes away from your
face.
If you de velop unusual symptoms, see your supervisor. Perhaps the welding atmosphere and ventilation system should be checked.
WEAR CORRECT EYE, EAR & BODY PROTECTION
PROTECT your eyes and face with welding helmet
properly fitted and with proper grade of filter plate (See ANSI Z49.1).
PROTECT your body from welding spatter and arc
flash with protective clothing including woolen clothing, flame-proof apron and gloves, leather leggings, and high boots.
PROTECT others from splatter, flash, and glare with
protective screens or barriers.
IN SOME AREAS, protection from noise may be
appropriate.
BE SURE protective equipment is in good condition.
Also, wear safety glasses in work area
DO NOT WELD OR CUT containers or materials which previously had
been in contact with hazardous substances unless they are properly cleaned. This is extremely dangerous.
DO NOT WELD OR CUT painted or plated parts unless special
precautions with ventilation have been taken. They can release highly toxic fumes or gases.
PROTECT compressed gas cylinders from excessive heat, mechanical
shocks, and arcs; fasten cylinders so they cannot fall.
BE SURE cylinders are never grounded or part of an electrical circuit. REMOVE all potential fire hazards from welding area. ALWAYS HAVE FIRE FIGHTING EQUIPMENT READY FOR
IMMEDIATE USE AND KNOW HOW TO USE IT.
SECTION A:
Diesel Engines
Gasoline Engines
WARNINGS
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACE­MAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
SAFETY
1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.
1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is
hot.
ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
FOR ENGINE POWERED EQUIPMENT.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporizing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1. Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as pos­sible to the area being welded.
2.d.5. Do not work next to welding power source.
3
SAFETY
ELECTRIC SHOCK CAN KILL.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage
two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
between the
ARC RAYS CAN BURN.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES CAN BE DANGEROUS.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases. When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep fumes
and gases away from the breathing zone. When welding
with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and within applicable OSHA PEL and ACGIH TLV limits using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
5. b. The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the specific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.
5.c. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating products.
3.j. Also see It ems 6.c. and 8.
5.d. Shielding gases used for arc welding can displace air and
injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
4
cause
SAFETY
WELDING AND CUTTING SPARKS CAN CAUSE FIRE OR EXPLOSION.
6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
CYLINDER MAY EXPLODE IF DAMAGED.
7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected to physical damage.
A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY POWERED EQUIPMENT.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention During Welding, Cutting and Other Hot Work”, available from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.
Refer to
http://www.lincolnelectric.com/safety
for additional safety information.
Welding Safety Interactive Web Guide for mobile devices
5
vi
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications.......................................................................................................A-1
Safety Precautions ........................................................................................................A-2
Machine Grounding.......................................................................................................A-2
Spark Arrester ...............................................................................................................A-2
Towing...........................................................................................................................A-2
Vehicle Mounting...........................................................................................................A-3
Pre-Operation Engine Service..............................................................................................A-3
Fuel, Oil, Battery Connections ......................................................................................A-3
Welding Cable Connections..........................................................................................A-4
Angle of Operation ........................................................................................................A-4
Lifting, Additional Safety Precautions............................................................................A-4
High Altitude Operation .................................................................................................A-4
Muffler Outlet Pipe ........................................................................................................A-4
Location and Ventilation................................................................................................A-5
Stacking ........................................................................................................................A-5
Connection of Wire Feeders .........................................................................................A-5
Connection of Tig Module .............................................................................................A-5
Additional Safety Precautions .......................................................................................A-5
Welding Operation Output, Auxiliary Power Receptacles, and Plugs .................................A-6
Motor Starting and Extension Cord Length Table ................................................................A-6
Electrical Device Used with the Ranger 225 ........................................................................A-7
Auxiliary Power While Welding, Standby Power Connections ............................................A-8
Premises Wiring ...................................................................................................................A-9
________________________________________________________________________________
Operation.........................................................................................................................Section B
Safety Precautions ...............................................................................................................B-1
General Description..............................................................................................................B-1
Welder Controls Function and Operation .............................................................................B-1
Range, Polarity Control Switch and Fuel Consumption .......................................................B-2
Start in/Shutdown Instructions.....................................................................................................B-3
Starting the Engine........................................................................................................B-3
Safety Precautions ........................................................................................................B-3
Stopping the Engine......................................................................................................B-3
Break-In Period .............................................................................................................B-3
Welding Process ..................................................................................................................B-4
Stick (Constant Current) Welding..................................................................................B-4
Scratch Start TIG (Constant Current) Welding .............................................................B-4
Wire Feed Welding Processes (Constant Voltage)......................................................B-5
Arc Gouging ..................................................................................................................B-5
Summary of Welding Processes ...................................................................................B-5
________________________________________________________________________________
Accessories ........................................................................................................Section C
Optional Equipment...............................................................................................C-1
Recommended Equipment....................................................................................C-2
________________________________________________________________________
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine Engine Maintenance ..........................................................................D-1,D2
Engine Adjustments...............................................................................................D-3
Slip Rings ..............................................................................................................D-3
Battery Maintenance .......................................................................................D-3
Engine Maintenance Parts..............................................................................D-3
________________________________________________________________________
Troubleshooting ..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide...................................................................................E-2, E-3
________________________________________________________________________
Wiring Diagrams, Connection Diagrams & Dimension Print.......................Section F
________________________________________________________________________
Parts List.................................................................................................................P-618
________________________________________________________________________
vi
A-1
INSTALLATION
TECHNICAL SPECIFICATIONS - RANGER® 225 ( K2857-1)
INPUT - GASOLINE ENGINE
Make/Model
Kohler
CH23S,
CH680
CH730
Description
2 cylinder
4 Cycle
Air-Cooled
Gasoline
Engine.
Aluminum Alloy
with Cast Iron
Liners,
Electronic
Ignition
RATED OUTPUT @ 104°F (40°C)- WELDER
RATED OUTPUT @ 104°F (40°C)- GENERATOR
Horsepower
23 HP @
3600 RPM
DC Constant Current 225A/25V/40% DC Constant Current 210A / 25V / 100% DC Constant Voltage 200A / 20V / 100%
Operating
Speed (RPM)
High Idle 3700
Full Load 3500
Low Idle 2200
Welding Output
Auxiliary Power
Displacement
cu. in.
(cu.cm.)
41.1(674)
44.2(724)
1
Starting
System
12VDC Battery
Electric Start
Group 58
Battery (435 cold Cranking
Amps)
A-1
Capacities
Fuel: 12 Gal (45.4 L) Lubricating Oil:
2.0 Qts. (1.9 L)
9,000 Watts Continuous, 60 Hz AC
10,500 Watts Peak, 60 Hz AC
120/240 Volts
RECEPTACLES AND CIRCUIT BREAKERS
RECEPTACLES
(2) 120VAC Duplex (5-20R)
(1) 120/240VAC Dual Voltage
Full KVA (14-50R)
AUXILIARY POWER CIRCUIT BREAKER
Two 20AMP for Two Duplex Receptacle
(1) 40AMP for Dual Voltage (2-pole)
BATTERY CHARGING CIRCUIT BREAKER
20AMP for Engine Battery
Charging Circuit
PHYSICAL DIMENSIONS
HEIGHT WIDTH DEPTH MODEL / WEIGHT
Codes 11797 and below
30.00** in. 21.50 in 42.25 in.
762.0 mm 546.0 mm 1073.0 mm
** Top of enclosure, add 6.00”(152mm) for exhaust.
514 lbs. (233kg.)
Code 12093
523 lbs. (237kg.)
ENGINE COMPONENTS
LUBRICATION VALVE LIFTERS FUEL SYSTEM GOVERNOR
Full Pressure Hydraulic Mechanical Fuel Pump Mechanical Governor
with Full Flow Filter Additional electric fuel lift pump
5% Regulation on K2382-4.
AIR CLEANER ENGINE IDLER MUFFLER ENGINE PROTECTION
Low noise Muffler: Top outlet Shutdown on low oil
Dual Element Automatic Idler can be rotated. Made from pressure.
long life, aluminized steel.
1
Output rating in watts is equivalent to volt - amperes at unity factor.Output voltage is within +/-10% at all loads up to rated capacity.
When welding available auxiliary power will be reduced.
RANGER® 225
A-2
INSTALLATION
A-2
SAFETY PRECAUTIONS
WARNING
Do not attempt to use this equipment until you have thoroughly read the engine manufacturerʼs manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground.
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
Use in open, well ventilated areas or vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
Do not operate with doors open or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
When this welder is mounted on a truck or trailer, itʼs frame must be electrically bonded to the metal frame of the vehicle. Use a #8 or larger copper wire connect­ed between the machine grounding stud and the frame of the vehicle.
Where this engine driven welder is connected to premises wiring such as that in your home or shop, itʼs frame must be connected to the system earth ground. See further connection instructions in the section enti­tled “Standby Power Connections”, as well as the arti­cle on grounding in the latest National Electrical Code and the local code.
In general, if the machine is to be grounded, it should be connected with a #8 or larger copper wire to a solid earth ground such as a metal water pipe going into the ground for at least ten feet and having no insulat­ed joints, or to the metal framework of a building which has been effectively grounded. The National Electrical Code lists a number of alternate means of grounding electrical equipment. A machine grounding stud marked with the symbol is provided on the front of the welder.
SPARK ARRESTER
See additional warning information at
front of this operatorʼs manual.
-----------------------------------------------------------
MACHINE GROUNDING
Because this portable engine driven welder or genera­tor creates itʼs own power, it is not necessary to con­nect itʼs frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.).
WARNING
To prevent dangerous electric shock, other equip­ment to which this engine driven welder supplies power must:
be grounded to the frame of the welder using a
grounded type plug, or be double insulated.
Do not ground the machine to a pipe that carries explosive or combustible material.
------------------------------------------------------------------------
Some federal, state, or local laws may require that gasoline engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this welder does not qualify as a spark arrester. When required by local regulations, the K1898-1 spark arrester must be installed and properly maintained.
CAUTION
An incorrect arrester may lead to damage to the engine or adversely affect performance.
------------------------------------------------------------------------
TOWING
The recommended trailer for use with this equipment for road, in-plant and yard towing by a vehicle Lincolnʼs K2635-1. If the user adapts a non-Lincoln trailer, he must assume responsibility that the method of attachment and usage does not result in a safety hazard nor damage the welding equipment. Some of the factors to be considered are as follows:
1. Design capacity of trailer vs. weight of Lincoln equipment and likely additional attachments.
2. Proper support of, and attachment to, the base of
the welding equipment so there will be no undue stress to the framework.
(1)
is
RANGER® 225
A-3
3. Proper placement of the equipment on the trailer to insure stability side to side and front to back when being moved and when standing by itself while being operated or serviced.
4. Typical conditions of use, i.e., travel speed; rough-
ness of surface on which the trailer will be operated; environmental conditions.
5. Conformance with federal, state and local laws
(1) Consult applicable federal, state and local laws regarding specific
requirements for use on public highways.
VEHICLE MOUNTING
INSTALLATION
(1)
WARNING
Improperly mounted concentrated loads may cause unstable vehicle handling and tires or other components to fail.
• Only transport this Equipment on serviceable vehicles which are rated and designed for such loads.
• Distribute, balance and secure loads so vehicle is stable under conditions of use.
• Do not exceed maximum rated loads for compo­nents such as suspension, axles and tires.
• Mount equipment base to metal bed or frame of vehicle.
• Follow vehicle manufacturerʼs instructions.
------------------------------------------------------------------------
PRE-OPERATION SERVICE
CAUTION
READ the engine operating and maintenance instructions supplied with this machine.
WARNING
• Stop engine while fueling.
• Do not smoke when fueling.
• Keep sparks and flame away from tank.
• Do not leave unattended while fueling.
• Wipe up spilled fuel and allow
GASOLINE
can cause fire or explosion.
------------------------------------------------------------------------
fumes to clear before starting engine.
• Do not overfill tank, fuel expan­sion may cause overflow.
GASOLINE FUEL ONLY
A-3
FUEL
Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel gauge while filling to prevent overfilling.
Stop fueling once the fuel gauge reads full. Do not top off tank. Be sure to leave filler neck empty to allow room for expansion.
FULL
WARNING
• Damage to the fuel tank may cause fire or explosion. Do not in the RANGER
-----------------------------------------------------------------------
OIL
LUBRICATION  SYSTEM  CAPACITY
Kohler CH20S, CH23S, CH680, CH730 - 2.0 Quarts (1.9 Liters)
The RANGER crankcase filled with SAE 10W-30 oil. Check the oil level before starting the engine. If it is not up to the full mark on the dip stick, add oil as required. Make cer­tain that the oil filler cap is tightened securely. Refer to the engine Ownerʼs Manual for specific oil recommen­dations.
the RANGER
(INCLUDING  FILTER)
®
225 is shipped with the engine
®
225 base or weld to
®
225 base.
drill holes
BATTERY CONNECTIONS
CAUTION
Use caution as the electrolyte is a strong acid that can burn skin and damage eyes.
------------------------------------------------------------------------
This welder is shipped with the negative battery cable disconnected. Make sure that the Engine Switch is in the “STOP” position and attach the disconnected cable securely to the negative battery terminal before attempting to operate the machine. If the battery is discharged and does not have enough power to start the engine, see the battery charging instructions in the Battery section.
NOTE: This machine is furnished with a wet charged battery; if unused for several months, the battery may require a booster charge. Be careful to charge the bat­tery with the correct polarity.
RANGER® 225
A-4
INSTALLATION
WELDING OUTPUT CABLES
With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces­sary. Loose connections will result in overheating of the output studs.
When welding at a considerable distance from the welder, be sure you use ample size welding cables. Listed below are copper cable sizes recommended for the rated current and duty cycle. Lengths stipulated are the distance from the welder to work and back to the welder again. Cable sizes are increased for greater lengths primarily for the purpose of minimizing cable voltage drop.
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
225 Amps
100% Duty Cycle
0-100 Ft. (0-31m)
100-150 Ft. (31-46m)
150-200 Ft. (46-61m)
1 AWG
1 AWG
1/0 AWG
ANGLE OF OPERATION
Internal combustion engines are designed to run in a level condition which is where the optimum perfor­mance is achieved. The maximum angle of operation for the engine is 15 degrees from horizontal in any direction. If the engine is to be operated at an angle, provisions must be made for checking and maintain­ing the oil at the normal (FULL) oil capacity in the crankcase in a level condition.
When operating at an angle, the effective fuel capacity will be slightly less than the specified 12 Gal. (45 L).
A-4
ADDITIONAL SAFETY PRECAUTION
WARNING
• Lift only with equipment of adequate lifting capacity.
• Be sure machine is stable when lifting.
• Do not lift this machine using lift bail if it is equipped with a heavy accessory such as trail­er or gas cylinder.
FALLING • Do not lift machine if lift bail is
EQUIPMENT can damaged.
cause injury. • Do not operate machine while
suspended from lift bail.
------------------------------------------------------------------------
HIGH ALTITUDE OPERATION
At higher altitudes, Welder output de-rating may be necessary. For maximum rating, de-rate the welder output 3.5% for every 1000 ft. (305m) above 3000 ft. (914m). If operation will consistently be at altitudes above 5,000 ft. (1525m), a carburetor jet designed for high altitudes should be installed. This will result in better fuel economy, cleaner exhaust and longer spark plug life. It will not give increased power. Contact your local authorized engine service shop for high altitude jet kits that are available from the engine manufacturer.
CAUTION
Do not operate with a high altitude jet installed at altitudes below 5000 ft. (1525m). This will result in the engine running too lean and result in higher engine operating temperatures which can shorten engine life.
------------------------------------------------------------------------
MUFFLER OUTLET PIPE
LIFTING
The RANGER® 225 weighs approximately 595lbs. (269.9kg) with a full tank of gasoline. A lift bail is mounted to the machine and should always be used when lifting the machine.
RANGER® 225
Using the clamp provided secure the outlet pipe to the outlet tube with the pipe positioned such that it will direct the exhaust in the desired direction. Tighten using a 9/16” socket or wrench.
A-5
INSTALLATION
LOCATION / VENTILATION
The welder should be located to provide an unrestrict­ed flow of clean, cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet. Also, locate the welder so that engine exhaust fumes are properly vented to an outside area.
STACKING
RANGER® 225 machines cannot be stacked.
CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS
WARNING
Shut off welder before making any electrical connections.
------------------------------------------------------------------------
WIRE FEED (CONSTANT VOLTAGE) CONNECTION OF LN-15 ACROSS-THE-ARC WIRE FEEDER
The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.
• Shut the welder off. Connect the electrode cable from the LN-15 to
“ELECTRODE” terminal of the welder. Connect
the the work cable to the “TO WORK” terminal of the welder.
• Connect Electrode leads appropriately to acquire desired polarity, either DC (-) or DC (+).
• Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.
• Set the “RANGE” switch to the “WIRE FEED-CV” position
• Place the Engine switch in the “Auto Idle” position when welding with MIG wire instead of self-shielded core wire, weld starts can be improved by setting the idle mode to “HIGH”.
• Adjust the wire feed speed at the LN-15 and adjust the welding voltage with the output “CONTROL” at the welder. when welding with MIG wire instead of self-shielded core wire, weld starts can be improved by setting the idle mode to “HIGH”
NOTE: LN-15 Control Cable model will not work with
Output “CONTROL” must be set above 3
.
the RANGER® 225.
A-5
Position the “RANGE” switch to the “WIRE FEED CV” position.
Attach the single lead from the LN-25 control box to the work using the spring clip on the end of the lead - it carries no welding current.
Place the engine switch in the “AUTO IDLE” posi­tion.
When welding with MIG wire instead of self­shielded core wire, weld starts can be improved by setting the idle mode to “HIGH”
Adjust wire feed speed at the LN-25 and adjust the welding voltage with the output “CONTROL” at the welder.
NOTE: The welding electrode is energized at all times, unless an LN-25 with built-in contactor is used. If the output “CONTROL” is set below “3”, the LN-25 contactor may not pull in.
CONNECTION OF THE LN-25 TO THE RANGER® 225
Shut the welder off. Connect the electrode cable from the LN-25 to
“ELECTRODE” terminal of the welder.
the Connect the work cable to the “TO WORK” termi­nal of the welder.
Attach working and electrode leads appropriately to acquire desired polarity, either DC (-) or DC (+).
CONNECTION OF K930-2 TIG MODULE TO THE RANGER® 225.
The TIG Module is an accessory that provides high frequency and shielding gas control for DC GTAW (TIG) welding. See IM528 supplied with the TIG Module for installation instructions.
NOTE: The TIG Module does not require the use of a high frequency bypass capacitor. However, if the RANGER® 225 is used with any other high frequency equipment, the bypass capacitor must be installed, order kit T12246.
.
INSTRUCTIONS
ADDITIONAL SAFETY PRECAUTIONS
Always operate the welder with the roof and case sides in place as this provides maximum protection from moving parts and assures proper cooling air flow.
Read and understand all Safety Precautions before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Ownerʼs Manual.
RANGER® 225
A-6
INSTALLATION
WELDER OPERATION
WELDER OUTPUT
• Maximum Open Circuit Voltage at 3700 RPM is 80 Volts RMS.
• Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For example, a 60% duty cycle represents 6 minutes of load and 4 minutes of no load in a 10 minute period. Duty Cycle for the RANGER® 225 is 100%.
RANGER® 225
Constant Current 210 Amps DC @ 25 Volts
Constant Voltage 200 Amps DC @ 20 Volts
AUXILIARY POWER
A-6
120/240 VOLT DUAL VOLTAGE RECEPTACLE
The 120/240 volt receptacle can supply up to 38 amps of 240 volt power to a two wire circuit, up to 38 amps of 120 volts power from each side of a three wire circuit (up to 76 amps total). Do not connect the 120 volt circuits in parallel. Current sensing for the automatic idle feature is only in one leg of the three wire circuit as shown in the following column.
GND
The RANGER® 225 can provide up to 9,000 watts of 120/240 volts AC, single phase 60Hz power for con­tinuous use, and up to 10,500 watts of 120/240 volts AC, single phase 60Hz power peak use. The front of the machine includes three receptacles for connecting the AC power plugs; one 50 amp 120/240 volt NEMA 14-50R receptacle and two 20 amp 120 volt NEMA 5­20R receptacles. Output voltage is within +/-10% at all loads up to rated capacity.
All auxiliary power is protected by circuit breakers. the 120V has 20 Amp circuit breakers for each duplex receptacle. The 120/240V Single Phase has a 40 Amp 2-pole Circuit Breaker that disconnects both hot leads simultaneously.
CAUTION
Do not connect any plugs that connect to the power receptacles in parallel.
-----------------------------------------------------------------------­Start the engine and set the “IDLER” control switch to the desired operating mode. Set the “CONTROL” to
10. Voltage is now correct at the receptacles for auxil­iary power.
120 V
240 V
120 V*
*Current Sensing for Automatic Idle. (Receptacle viewed from front of Machine)
120 V DUPLEX RECEPTACLES
The 120V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs.
The current rating of any plug used with the system must be at least equal to the current load through the associated receptacle.
MOTOR STARTING
Most 1.5 hp AC single phase motors can be started if there is no load on the motor or other load connected to the machine, since the full load current rating of a
1.5 hp motor is approximately 20 amperes (10 amperes for 240 volt motors). The motor may be run at full load when plugged into only one side of the duplex receptacle. Larger motors through 2 hp can be run provided the receptacle rating as previously stated is not exceeded. This may necessitate 240V operation only.
(Use the shortest length extension cord possible sized per the following table.)
RANGER® 225 Extension Cord Length Recommendations
Current
(Amps)
15 20 15 20 38
Voltage
Volts
120 120 240 240 240
Load
(Watts)
1800 2400 3600 4800 9000
Conductor size is based on maximum 2.0% voltage drop.
Maximum Allowable Cord Length in ft. (m) for Conductor Size
14 AWG 30 (9)
60 (18)
12 AWG 40 (19)
30 (9) 75 (23) 60 (18)
10 AWG 75 (23) 50 (15)
150 (46) 100 (30)
50 (15)
8 AWG 125 (38) 88 (27) 225 (69) 175 (53)
90 (27)
6 AWG 175 (53) 138 (42) 350 (107) 275 (84)
150 (46)
RANGER® 225
4 AWG 300 (91) 225 (69) 600 (183) 450 (137)
225 (69)
A-7
ELECTRICAL DEVICE USE WITH THE RANGER® 225.
Type Common Electrical Devices Possible Concerns
Resistive Heaters, toasters, incandescent NONE
light bulbs, electric range, hot pan, skillet, coffee maker.
Capacitive TV sets, radios, microwaves, Voltage spikes or high voltage
appliances with electrical control. regulation can cause the capaci-
Inductive Single-phase induction motors, These devices require large
drills, well pumps, grinders, small current inrush for starting. refrigerators, weed and hedge Some synchronous motors may trimmers be frequency sensitive to attain
INSTALLATION
TABLE lll
tative elements to fail. Surge protection, transient protection, and additional loading is recom­mended for 100% fail-safe oper-
ation. DO NOT RUN THESE
DEVICES WITHOUT ADDI­TIONAL RESISTIVE TYPE LOADS.
maximum output torque, but they SHOULD BE SAFE from any frequency induced failures.
A-7
Capacitive/Inductive Computers, high resolution TV sets, An inductive type line condition-
complicated electrical equipment. er along with transient and
surge protection is required, and
liabilities still exist. DO NOT
USE THESE DEVICES WITH A RANGER® 225
The Lincoln Electric Company is not responsible for any damage to electrical components improperly connected to the RANGER® 225.
RANGER® 225
A-8
INSTALLATION
AUXILIARY POWER WHILE WELDING
Simultaneous welding and power loads are permitted by following Table I. The permissible currents shown assume that current is being drawn from either the 120V or 240V supply (not both at the same time). Also, the “Output Control” is set at “10” for maximum auxiliary power.
TABLE I
SIMULTANEOUS WELDING AND POWER
Output Selector Permissible Power Permissible Auxiliary
Setting Watts (Unity Power Current in Amperes
Factor) @ 120V
Max. Stick or Wire
Feed Setting None 0 0
145 Stick Setting 3450 32
90 Stick Setting 6000 50
*-or- @ 240V
** 16
** 25
A-8
1. Install a double pole, double throw switch between the power company meter and the premises dis­connect.
Switch rating must be the same or greater than the customerʼs premises disconnect and service over­current protection.
2. Take necessary steps to assure load is limited to the capacity of the RANGER® 225 by installing a 40 amp 240V double pole circuit breaker. Maximum rated load for the 240V auxiliary is 38 amperes. Loading above 38 amperes will reduce output voltage below the allowable -10% of rated voltage which may damage appliances or other motor-driven equipment.
3. Install a 50 amp 120/240V plug (NEMA type 14-50) to the Double Pole Circuit Breaker using No. 8, 4 conductor cable of the desired length. (The 50 amp 120/240V plug is available in the optional plug kit.)
No Welding 9000 76
** 38
* Each duplex receptacle is limited to 20 amps.
**Not to exceed 40A per 120VAC branch circuit when
splitting the 240 VAC output.
STANDBY POWER CONNECTIONS
The RANGER® 225 is suitable for temporary, standby, or emergency power using the engine manufacturerʼs recommended maintenance schedule.
The RANGER® 225 can be permanently installed as a standby power unit for 240V-3 wire, single phase 38 ampere service.
WARNING
(Connections must be made by a licensed electri­cian who can determine how the 120/240V power can be adapted to the particular installation and comply with all applicable electrical codes.) The following information can be used as a guide by the electrician for most applications (refer also to the connection diagram shown in Figure 1.)
-------------------------------------------------------------------------
4. Plug this cable into the 50 amp 120/240V recepta­cle on the RANGER® 225 case front.
RANGER® 225
A-9
INSTALLATION
Figure 1
CONNECTION OF RANGER® 225 TO PREMISES WIRING
A-9
WARNING
Connection of RANGER® 225 to premises wiring must be done by a licensed electrician and must comply with the National Electrical Code and all other applicable electrical codes.
RANGER® 225
B-1
OPERATION
SAFETY PRECAUTIONS
Do not attempt to use this equipment until you have thoroughly read the engine manufacturerʼs manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground
• Always wear dry insulating gloves.
• Always operate the welder with the hinged door
closed and the side panels in place.
• Read carefully the Safety Precautions page
before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Instruction Manual.
------------------------------------------------------------------------
GENERAL DESCRIPTION
The RANGER® 225 is a twin-cylinder, gasoline dri­ven, multiprocess arc welder and AC power genera­tor. It is built in a heavy gauge steel case for durability on the job site.
Codes 11790 and above meet EPA evaporative emis­sion requirements.
B-1
WELDER CONTROLS - FUNCTION AND OPERATION
ENGINE SWITCH
The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine.
When placed in the “OFF” position, the ignition circuit is de-energized to shut down the engine.
When held in the “START” position, the engine starter motor is energized.
When in “HIGH IDLE” ( ) position, the engine will run continuously at high idle.
When in “AUTO IDLE” ( / ) position, the engine will run continuously and the idler operates as follows:
Welding
When the electrode touches the work, the welding arc is initiated and the engine accelerates to full speed.
After welding ceases (and no auxiliary power is being drawn), the engine will return to low idle after approximately 10 to 14 seconds.
Auxiliary Power
With the engine running at low idle and auxiliary power for lights or tools is drawn (approximately 100-150 watts or greater) from the receptacles, the engine will accelerate to high speed.  If no power is being drawn from the receptacles (and not welding) for 10-14 seconds, the idler reduces the engine speed to low idle.
RANGER® 225
B-2
OPERATION
RANGE” SWITCH
The “Range” switch is used to select one of four amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range.
Process Range Setting Current Range
STICK/TIG (constant current) (3 range settings)
WIRE FEED
(constant voltage)
(1 range setting)
90 Max. 145 Max. 225 MAX
15 to 25V
40 to 90 Amps
70 to 145 Amps
120 to 225 Amps
Up to 200 Amps
CAUTION
Never change the “RANGE” Switch setting while welding. This will damage the switch.
------------------------------------------------------------------------
CONTROL” DIAL
Provides a fine welding current adjustment within the Range Switch settings in the STICK mode and weld­ing voltage control with the Range switch set in the wire feed mode.
B-2
Low Idle - No Load
2400 RPM High Idle - No Load 3700 RPM DC CC Weld Output 210 Amps @ 25 Volts DC CV Weld Output 200 Amps @ 20 Volts Auxiliary Power 9000 Watts
RANGER® 225 APPROXIMATE FUEL CONSUMPTION
KOHLER
23 H.P. COMMAND (CH23S, CH680)
.40 Gallons/Hour
(1.50 Liters/Hour)
.7 Gallons/Hour
(2.8 Liters/Hour)
1.3 Gallons/Hour (4.9 Liters/Hour)
1.2 Gallons/Hour (4.5 Liters/Hour)
1.4 Gallons/Hour) (5.3 Liters/Hour)
23 H.P. COMMAND (CH730)
.41 Gallons/Hour
(1.6 Liters/Hour)
.9 Gallons/Hour
(3.5 Liters/Hour)
1.5 Gallons/Hour (5.7 Liters/Hour)
1.4 Gallons/Hour (5.2 Liters/Hour)
1.7 Gallons/Hour (6.4 Liters/Hour)
KOHLER
RANGER® 225