Lincoln Electric CLASSIC III 10156, CLASSIC III 10061, CLASSIC III 10033, CLASSIC III 10072 User Manual

CLASSIC ®III & CLASSIC ®III D
RETURN TO MAIN MENU
For Machines with Code Numbers 10033, 10061, 10072 or 10156
Safety Depends on You
Lincoln arc welding equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
IM529-A
Supersedes IM482
OPERATOR’S MANUAL
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
i
SAFETY
i
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause can­cer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame welding arc or when the engine is running. Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz­ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.
___________________________________________________
1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND MAGNETIC FIELDS may be dangerous
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Mar ‘95
ii
SAFETY
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth) ground.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
3.f.
Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
5.b.
Do not weld in locations near chlorinated hydrocarbon
coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors form phosgene, a highly toxic gas, and other irritating products.
5.c. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
5.d. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employer’s safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.e. Also see item 1.b.
Mar ‘95
vapors
to
iii
SAFETY
iii
WELDING SPARKS can cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even been “cleaned”. For information, purchase “Recommended Safe Practices for the Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f. free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate cir­cuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
Remember that welding sparks and hot
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode if damaged.
7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.
Mar ‘95
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv­antes:
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à l’électrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on
soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions pour le porte-électrode s’applicuent aussi au pistolet de soudage.
zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de la masse. Un court-circuit accidental peut provoquer un échauffement et un risque d’incendie.
8. S’assurer que la masse est connectée le plus prés possible de la zone de travail qu’il est pratique de le faire. Si on place la masse sur la charpente de la construction ou d’autres endroits éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de lev­age, câbles de grue, ou autres circuits. Cela peut provoquer des risques d’incendie ou d’echauffement des chaines et des câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage. Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant d’opérations de dégraissage, nettoyage ou pistolage. La chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas fortement toxique) ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA Standard W 117.2-1974.
2. Dans le cas de travail au dessus du niveau du sol, se protéger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de n’importe quelle partie du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel, donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi qu’un verre blanc afin de se protéger les yeux du ray­onnement de l’arc et des projections quand on soude ou quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de l‘arc.
c. Protéger l’autre personnel travaillant à proximité au
soudage à l’aide d’écrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de l’arc de soudage. Se protéger avec des vêtements de protection libres de l’huile, tels que les gants en cuir, chemise épaisse, pan­talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les
PRÉCAUTIONS DE SÛRETÉ POUR LES MACHINES À SOUDER À TRANSFORMATEUR ET À REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de l’électricité et aux recommendations du fabricant. Le dispositif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront effectués par un électricien qualifié.
3. Avant de faires des travaux à l’interieur de poste, la debranch­er à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
Mar. ‘93
for selecting a QUALITY product by Lincoln Electric. We want you
Thank You
to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Model Name & Number _____________________________________
Code & Serial Number _____________________________________
Date of Purchase _____________________________________
Whenever you request replacement parts for or information on this equipment always supply the information you have recorded above.
vv
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection. The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications.......................................................................................................A-1
General Description..............................................................................................................A-2
Design Features ...................................................................................................................A-2
Pre-Operation Installation.....................................................................................................A-3
Safety Precautions ........................................................................................................A-3
Exhaust Spark Arrester .................................................................................................A-3
Location/Ventilation.......................................................................................................A-3
Stacking ........................................................................................................................A-3
Angle of Operation ........................................................................................................A-3
Machine Grounding.......................................................................................................A-3
Lift Bail ..........................................................................................................................A-4
Trailers ..........................................................................................................................A-4
Polarity Control and Cable Sizes ..................................................................................A-4
Pre-Operation Service..........................................................................................................A-5
Oil..................................................................................................................................A-5
Fuel ...............................................................................................................................A-5
Cooling System .............................................................................................................A-5
Battery Charging ...........................................................................................................A-5
vi
Operation.........................................................................................................................Section B
Engine Operation .................................................................................................................B-1
Starting The Continental TM27 Engine ................................................................................B-1
Starting The Continental TMD27 Engine..............................................................................B-1
Stopping the engine .............................................................................................................B-1
Welder Operation .................................................................................................................B-2
Duty Cycle ............................................................................................................................B-2
Control of Welding Current...................................................................................................B-2
Idler Operation......................................................................................................................B-2
Auxiliary Power .............................................................................................................B-3
Carburetor Deicing Kit
Accessories ....................................................................................................................Section C
Optional Features (Field Installed) .......................................................................................C-1
Maintenance....................................................................................................................Section D
Safety Precautions ...............................................................................................................D-1
General Instructions..............................................................................................................D-1
Cooling System.....................................................................................................................D-1
Bearings................................................................................................................................D-1
Commutator and Brushes .....................................................................................................D-1
Idler Maintenance .................................................................................................................D-2
Nameplates...........................................................................................................................D-2
Engine Service Chart ............................................................................................................D-3
...............................................................................................B-3
Troubleshooting .............................................................................................................Section E
Safety Precautions ...............................................................................................................E-1
Welder Troubleshooting ........................................................................................................E-2
Electronic Idler Troubleshooting Guide .................................................................................E-3
Engine Troubleshooting Guide (TM27 Only) ................................................................E-4, E-5
Diagrams..........................................................................................................................Section F
Wiring Diagram (Classic III)..................................................................................................F-1
Wiring Diagram (Classic III D) ..............................................................................................F-2
Dimension Print ....................................................................................................................F-3
Parts Manual..............................................................................P232 Series (IIID), P302 Series (III)
A-1
INSTALLATION
TECHNICAL SPECIFICATIONS – CLASSIC III AND IIID
Machine
A-1
Product
Name
Classic III
Classic III D
Ordering
Information
K1428-2
@
CSA
w/o Wire Feed
Module
K1428-3
@
CSA
w/ Wire Feed
Module
K1433-1
@
CSA
w/o Wire Feed
Module
K1433-2
@
CSA
w/ Wire Feed
Module
@
Meets Canadian Standards
Description
300 Amp DC
Arc Welder
All Copper
Windings
Pure DC Power
Generator
Rated DC Output *
Amps / Volts / Duty Cycle
225A / 29V / 100%
300A / 32V / 50%
350A / 34V / 30%
* Based on a 10 min. period.
DC Current Range
(Fine Adjustment in Each Range)
40 - 350 Amps
220 - Max 160 - 240 120 - 190
80 - 130
Min - 90
40 - 350 Amps
220 - Max 160 - 240 120 - 190
80 - 130
Min - 90
Auxiliary
Power
3000 Watts,
60 Hz. AC
26 Amps @
115V
13 Amps @
230V
3000 Watts,
60 Hz. AC
26 Amps @
115V
13 Amps @
230V
Dimensions
& Weight
40.94 x 24.0 x 66.25in
(1040 x 610 x 1683 mm)
1406 lbs (638 kg)
40.94 x 24.0 x 66.25 in
(1040 x 610 x 1683mm)
1445 lbs (657 kg)
Engine
Product
Name
Classic III
Classic III D
Description Horsepower Operating
4 Cylinder
4 Cycle
Water-Cooled
Gasoline Engine
Cast Iron Cylinder,
Block/Crankcase
4 Cylinder
4 Cycle Water-Cooled Diesel Engine
Cast Iron Cylinder,
Block/Crankcase
45 HP
@ 1700 RPM
38.9 HP
@ 1700 RPM
Speeds
Full Load:
1725 RPM
High Idle:
1800 RPM
Low Idle:
1350 RPM
Displacement Ignition Capacities
Distributor Type
Electronic
164.7 Cu In (2.7 ltrs)
Diesel
Fuel:
15 Gals (57 Ltrs)
Lubricating Oil:
7.0 Qts (6.7 Ltrs)
Coolant:
9.3 Qts (8.8 Ltrs)
CLASSIC III AND IIID
A-2
INSTALLATION
A-2
GENERAL DESCRIPTION
The Classic®III and Classic®III D are heavy duty, engine driven, DC arc welding power sources capable of providing constant current output for stick welding or DC TIG welding. These welders are wound with all copper coils, rated at 300 amps/32 Volts, and provide other Classic features such as improved door latches and stainless hinges. With the addition of the optional
K623-1 Wire Feed Module™, the Classic III or Classic III D will provide constant voltage output for running the LN-7, LN-23P, or LN-25 wire feeders. (The Wire Feed Module is factory installed on the K1428-3 and K1433-2).
The Classic III D has Diesel Engine Protection. In the event of sudden low oil pressure or high coolant tem­perature, the engine immediately shuts down. The Classic III & Classic III D have a current range of 40­350 DC amps with output ratings as follows:
RATED OUTPUT DUTY CYCLE
225A @ 29V 300A @ 32V 350A @ 34V
These units are also capable of providing 3 kVA of 115/230 volts of 60 cycle AC auxiliary power.
100%
50% 30%
DESIGN FEATURES
Control Panel
Both the engine and the welder controls are located on one recessed panel at the exciter end of the machine. The welder controls consist of a five step “Current Range Selector” switch and a “Fine Current Adjustment” rheostat. Each welder is equipped with a “Start” button, an “Ignition” switch and an “Idler” con­trol switch. The diesel version comes with a “Glow Plug” feature for easier cold weather starting.
The control panels also contain an engine tempera­ture gauge (diesel only), a battery charging ammeter, an oil pressure gauge (oil pressure light on the gaso­line version), two three prong grounding type recepta­cles and circuit breakers for auxiliary power, and a choke control (gasoline version only).
All Copper Windings - For long life and dependable operation.
Engine Idler - Both the Classic III & III D are equipped with an electronic automatic engine idler. It automatically increases and decreases engine speed
when starting and stopping welding or using aux­iliary power. A built-in time delay permits changing
electrodes before the engine slows to its low idle speed. The “Idler” control switch on the panel locks the idler in full speed position when desired.
The Classic III unit uses the Continental TM27 industrial water-cooled Gasoline engine, while the
Classic III D uses the Continental TMD27®industrial water-cooled Diesel engine.
Auxiliary Power - 3.0 kVA of nominal 115/230V,
®
60Hz, AC. Output voltage is maintained within ± 10% at all loads up to rated capacity. (See Optional Features for Power Plug Kits.)
Welder Enclosure - The complete welders are rubber mounted on a rugged steel “C” channel base.
The output terminals are placed at the side of the machines so that they are protected by the door. The output terminals are labeled (+) and (-).
Cranking System - A 12 volt electric starter is stan­dard.
Air Cleaner - Heavy duty two stage dry type.
Muffler - A muffler and rain cap are standard.
Engine Hour Meter - A meter to record hours of oper-
ation. Diesel Engine Protection - The system shuts the diesel engine down in the event of sudden low oil pressure or high coolant temperature.
Carburetor Deicing Kit
Classic III Welders are equipped with a kit, that prevents carburetor icing when outside temperature is 60°F/15.5°C or lower.
CLASSIC III AND IIID
A-3
INSTALLATION
A-3
PRE-OPERATION INSTALLATION
WARNING
Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or electrode with skin or wet clothing.
• Insulate yourself from work and ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or vent exhaust outside.
------------------------------------------------------------------------
MOVING PARTS can injure.
• Do not operate with doors open or guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information at the
front of this operator’s manual.
-----------------------------------------------------------
Exhaust Spark Arrester
Some federal, state or local laws may require that engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard mufflers included with these welders do not qualify as spark arresters. When required by local regulations, suitable spark arresters must be installed and properly maintained.
CAUTION
Use of an incorrect arrester may lead to engine damage or performance loss. Contact the engine manufacturer for specific recommendations.
------------------------------------------------------------------------
Location / Ventilation
STACKING
Classic III and III D machines cannot be stacked.
ANGLE OF OPERATION
To achieve optimum engine performance the Classic III and III D should be run in a level position. The max­imum angle of operation for the TM27 and TMD27 engines is 60 degrees in a direction to cause the air intake manifold to be angled up, 45 degrees for the air intake manifold to be angled down, and 50 degrees for the welder control panel to be angled up or down. If the engine is to be operated at an angle, provisions must be made for checking and maintaining the oil level at the normal (FULL) oil capacity in the crankcase. When operating the welder at an angle, the effective fuel capacity will be less than the speci­fied 15 gallons (57 Ltrs.).
Machine Grounding
According to the United States National Electrical Code, the frame of this portable generator is not required to be grounded and is permitted to serve as the grounding means for cord connected equipment plugged into its receptacle.
Some state, local, or other codes or unusual operating circumstances may require the machine frame to be grounded. It is recommended that you determine the extent to which such requirements may apply to your particular situation and follow them explicitly. A machine grounding stud marked with the symbol is provided on the welding generator frame foot. (If an older portable welder does not have a grounding stud, connect the ground wire to an unpainted frame screw or bolt.) In general, if the machine is to be grounded, it should be connected with a #8 or larger copper wire to a solid earth ground such as a metal water pipe going into the ground for at least ten feet and having no insulated joints, or to the metal framework of a building which has been effectively grounded. The U.S. National Code lists a number of alternate means of grounding electrical equipment.
Always operate the welder with the doors closed. Leaving the doors open changes the designed air flow and may cause overheating.
The welder should be located to provide an unrestrict­ed flow of clean, cool air. Also, locate the welder so that engine exhaust fumes are properly vented to an outside area.
CLASSIC III AND IIID
A-4
INSTALLATION
A-4
Lift Bail
A lift bail is provided for lifting with a hoist.
WARNING
FALLING EQUIPMENT can cause
injury.
• Do not lift this machine using lift bale if it is equipped with a heavy accessory such as a trailer or gas cylinder.
• Lift only with equipment of adequate lifting capacity.
• Be sure machine is stable when lifting.
----------------------------------------------------------------------
Trailer (See Optional Features)
If the user adapts a non-Lincoln trailer, he must assume responsibility that the method of attachment and usage does not result in a safety hazard nor dam­age the welding equipment. Some of the factors to be considered are as follows:
Polarity Control and Cable Sizes
With the engine off, route the electrode and work cables through the strain relief bracket on the base and connect to the studs located below the fuel tank mounting rail. (See size recommendations below.) For positive polarity, connect the electrode cable to the terminal marked “+”. For Negative polarity, con­nect the electrode cable to the “-” stud. These con­nections should be checked periodically and tightened if necessary.
When welding at a considerable distance from the welder, be sure you use ample size welding cables.
RECOMMENDED COPPER CABLE SIZES
Cables Sizes for Combined Length of Electrode Plus Work Cable
Amps Duty Cycle Up to 200 ft. 200 to 250 ft.
225 100% 1 1/0 300 50% 1/0 2/0 350 30% 2/0 3/0
1. Design capacity of trailer vs. weight of Lincoln
equipment and likely additional attachments.
2. Proper support of, and attachment to, the base of
the welding equipment so there will be no undue stress to the framework.
3. Proper placement of the equipment on the trailer to
ensure stability side to side and front to back when being moved and when standing by itself while being operated or serviced.
4. Typical conditions of use, i.e., travel speed, rough-
ness of surface on which the trailer will be operated; environmental conditions, likely maintenance.
5. Conformance with federal, state and local laws.
(1)
Consult applicable federal, state and local laws regarding specific
requirements for use on public highways.
(1)
CLASSIC III AND IIID
Loading...
+ 23 hidden pages