Date:
Trade Name:
2/8/05
Softweld 99Ni
MSDS No.:
CAN-M393
Sizes: All
Supersedes: 2/25/02
M A T E R I A L S A F E T Y D A T A S H E E T
Conforms to Workplace Hazardous Materials Information System (WHMIS) Rev. November, 1988
Section I & II - Preparation and Product Information
The Lincoln Electric Company of Canada LP
179 Wicksteed Avenue
Toronto, Ontario M4G 2B9 CANADA
Phone: (416) 421-2600
I M P O R T A N T !
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal use of this
product are covered by Section VII; see it for industrial hygiene information.
CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes.
Ingredients: CAS No. Wt. %
Limestone and/or calcium carbonate 1317-65-3 1-5 10
Iron 7439-89-6 1-5 10*
Graphite 7782-42-5 1-5 2.0
Fluorides (as F) 7789-75-5 1-5 2.5
Strontium compounds (as Sr) 1633-05-2 1-5 10*
Silicates and other binders 1344-09-8 1-5 10*
Manganese and/or manganese alloys and compounds (as Mn) 7439-96-5 0.1-1 0.2
Mineral silicates 1332-58-7 0.1-1 5**
Cellulose and other carbohydrates 65996-61-4 0.1-1 10*
Titanium dioxides (as Ti) 13463-67-7 0.1-1 10
The term “hazardous” in “Hazardous Ingredients” should be interpreted as a term required and defined in the Hazardous Products Act and does
not necessarily imply the existence of any hazard.
For Welding Consumables and Related Products
Product Type:
Representative Classifications:
Prepared by The Lincoln Electric Company, Cleveland, Ohio, USA
(216) 481-8100, on the date shown above.
Covered Electrode
AWS ENi-CI
Section III - Hazardous Ingredients (1)
TLV
3
mg/m
(Route/Species)
oral/rat) reproductive
LD
50
LC50 mg/m
(Route/Species)
Not Available Not Available
Not Available Not Available
Not Available Not Available
4250 mg/kg
oral/rat
Not Available Not Available
1153 mg/kg
oral/rat
9 g/kg
oral/rat
590 g/kg LDLo
Not Available Not Available
Not Available Not Available
Not Available
Not Available
2.3 LCLo
inhalation/human
Not Available
3
Nickel core wire
7440-02-0
Notes: (*) Not listed. Nuisance value maximum is 10 milligrams per cubic
meter. TLV value for iron oxide is 5 milligrams per cubic meter.
60-100
1.5
(LDLo, LCLo) Lowest published toxic concentration.
50 mg/kg LDLo
intravenous/mouse
Not Available
(**) As respirable dust.
Section IV - Physical Data
Physical data such as odor, vapor pressure, density, evaporation rate and freezing or boiling points are not listed as they are not applicable to
this product and its use.
Section V - Hazard Data
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See CSA W117.2 Section 9.7 as referenced in
Section VIII. Product is inert, no special handling or spill procedures required.
Rev 7/04 (CONTINUED ON SIDE TWO)
Product: Softweld 99Ni
Date: 2/8/05
Acute Lethality Values: LC
specified length of time in an animal assay, is expected to cause the death of 50% of a defined animal population.
LD50 means the single dose of a substance that, when administered by a defined route in an animal assay, is expected to cause
the death of 50% of a defined animal population.
Threshold Limit Value: The ACGIH recommended general limit for Welding Fume NOS - (Not Otherwise Specified) is 5 mg/m
The TLV-TWA is the time-weighted average concentration for a normal 8-hour workday and a 40 hour workweek, to which nearly all workers may be
repeatedly exposed, day after day, without adverse effect. See Section VII for specific fume constituents which may modify this TLV. Threshold Limit
Values are figures published by the American Conference of Government Industrial Hygienists.
Effects of Overexposure: Electric arc welding may create one or more of the following health hazards:
Fumes and Gases can be dangerous to your health. Common entry is by inhalation. Other possible routes are skin contact and ingestion.
Short-term (acute) overexposure to welding fumes may result in discomfort such as metal fume fever, dizziness, nausea,
Long-term (chronic) overexposure to welding fumes can lead to siderosis (iron deposits in lung) and may affect
Electric Shock can kill. If welding must be performed in damp locations or with wet clothing, on metal structures or when in cramped
positions such as sitting, kneeling or lying, or if there is a high risk of unavoidable or accidental contact with workpiece, use the following
equipment: Semiautomatic DC Welder, DC Manual (Stick) Welder, or AC Welder with Reduced Voltage Control.
or dryness or irritation of nose, throat, or eyes. May aggravate pre-existing respiratory problems (e.g. asthma,
emphysema). Exposure to extremely high levels of fluorides can cause abdominal pain, diarrhea, muscular weakness, and
convulsions. In extreme cases it can cause loss of consciousness and death.
pulmonary function. Manganese overexposure can affect the central nervous system, resulting in impaired speech and
movement. Bronchitis and some lung fibrosis have been reported. Repeated exposure to fluorides may cause excessive
calcification of the bone and calcification of ligaments of the ribs, pelvis and spinal column. May cause skin rash. Nickel and its
compounds are on the IARC (International Agency for Research on Cancer) and NTP (National Toxicology Program) lists as posing a
carcinogenic risk to humans.
Arc Rays can injure eyes and burn skin. Skin cancer has been reported..
means the concentration of a substance in air that when administered by means of inhalation over a
50
3
.
Section VII - Reactivity Data
Hazardous Decomposition Products: Welding fumes and gases cannot be classified simply. The composition and quantity of both are
dependent upon the metal being welded, the process, procedure and electrodes used.
Other conditions which also influence the composition and quantity of the fumes and gases to which workers may be exposed include:
coatings on the metal being welded (such as paint, plating, or galvanizing), the number of welders and the volume of the worker area, the
quality and amount of ventilation, the position of the welder's head with respect to the fume plume, as well as the presence of contaminants
in the atmosphere (such as chlorinated hydrocarbon vapors from cleaning and degreasing activities.)
When the electrode is consumed, the fume and gas decomposition products generated are different in percent and form from the
ingredients listed in Section III. Decomposition products of normal operation include those originating from the volatilization, reaction, or
oxidation of the materials shown in Section III, plus those from the base metal and coating, etc., as noted above.
Reasonably expected fume constituents of this product would include: Primarily oxides of calcium, fluorides and strontium;
secondarily complex oxides of iron, manganese, nickel, potassium, silicon and sodium.
Section VI - Health Hazard Data and Toxicological Properties
Maximum fume exposure guideline for this product is 5.0 milligrams per cubic meter.
Gaseous reaction products may include carbon monoxide and carbon dioxide. Ozone and nitrogen oxides may be formed by the radiation
from the arc.
Determine the composition and quantity of fumes and gases to which workers are exposed by taking an air sample from inside the welder's
helmet if worn or in the worker's breathing zone. Improve ventilation if exposures are not below limits. See ANSI/AWS F1.1, F1.2, F1.3 and
F1.5, available from the American Welding Society, 550 N.W. LeJeune Road, Miami, FL 33126.
Section VIII - Preventive Measures and Precautions for Safe Handling and Use
Read and understand the manufacturer's instruction and the precautionary label on the product. Request Lincoln Safety Publication E205. See Canadian
Standards Association Standard CSA-W117.2 'Safety in Welding, Cutting, and Allied Processes' published by the Canadian Standards Association, 178
Rexdale Blvd., Rexdale, Ontario M9W1R3 for more details on many of the following:
Ventilation: Use enough ventilation, local exhaust at the arc, or both to keep the fumes and gases from the worker's breathing zone and the general area.
Train the welder to keep his head out of the fumes. Keep exposure as low as possible.
Respiratory Protection: Use respirable fume respirator or air supplied respirator when welding in confined space or general work area when local exhaust
or ventilation does not keep exposure below TLV.
Eye Protection: Wear helmet or use face shield with filter lens shade number 12 or darker. Shield others by providing screens and flash goggles.
Protective Clothing: Wear hand, head, and body protection which help to prevent injury from radiation, sparks and electrical shock. See W117.2.
At a minimum this includes welder's gloves and a protective face shield, and may include arm protectors, aprons, hats, shoulder protection, as well as dark
substantial clothing. Train the welder not to permit electrically live parts or electrodes to contact skin . . . or clothing or gloves if they are wet. Insulate from
work and ground.
Disposal Information: Discard any product, residue, disposable container, or liner as ordinary waste in an environmentally acceptable manner according
to Federal, State and Local regulations unless otherwise noted. No applicable ecological information available.
Section IX - Emergency and First Aid Procedures
Call for medical aid. Employ first aid techniques recommended by the Canadian Red Cross. IF BREATHING IS DIFFICULT give oxygen. IF NOT
BREATHING employ CPR (Cardiopulmonary Resuscitation) techniques. IN CASE OF ELECTRICAL SHOCK, turn off power and follow recommended
treatment. In all cases call a physician.