Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation ...
and thoughtful operation on your
part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT
READING THIS MANUAL AND
THE SAFETY PRECAUTIONS
CONTAINED THROUGHOUT.
And, most importantly, think
before you act and be careful.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Page 2
i
SAFETY
i
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents
are known to the State of California to cause cancer, birth defects, and other reproductive harm.
The Above For Diesel Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you
purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available
from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
1.c. Do not add the fuel near an open flame
welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporizing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.
1.d. Keep all equipment safety guards, covers and devices in
position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving
parts when starting, operating or repairing equipment.
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fi elds m ay interf ere wi th some pacemak ers, a nd
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
Page 3
ii
SAFETY
ii
ELECTRIC SHOCK can
kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES
can be dangerous.
5.a. Welding ma y produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases. When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and within applicable OSHA PEL and
ACGIH TLV limits using local exhaust or mechanical
ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required.
Additional precautions are also required when welding
on galvanized steel.
5. b. The operation of welding fume control equipment is affected
by various factors including proper use and positioning of
the equipment, maintenance of the equipment and the specific welding procedure and application involved. Worker
exposure level should be checked upon installation and
periodically thereafter to be certain it is within applicable
OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
form phosgene, a highly toxic gas, and other irritating products.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
vapors
to
5.e. Read and understand the manufacturerʼs instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employerʼs safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
Page 4
iii
SAFETY
iii
WELDING and CUTTING
SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
Sparks and spatter are thrown from the welding arc. Wear oil
6.f.
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains
or cables until they fail.
6.h. Also see item 1.c.
the welding sparks from starting a fire.
though
they have
Preparation
for Welding and Cutting of
CYLINDER may explode
if damaged.
7.a. Use on ly com pr essed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Alway s keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to
physical damage.
• A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Re ad and foll ow the inst ru ctions o n c ompressed ga s
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturerʼs
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturerʼs recommendations.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention
During Welding, Cutting and Other Hot Work”, available
from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma
022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Refer to http://www.lincolnelectric.com/safety for additional safety information.
Page 5
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions
et les précautions de sûreté specifiques qui parraissent dans ce
manuel aussi bien que les précautions de sûreté générales suivantes:
Sûreté Pour Soudage A LʼArc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à lʼélectrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours
tout contact entre les parties sous tension et la peau nue
ou les vétements mouillés. Porter des gants secs et sans
trous pour isoler les mains.
b. Faire trés attention de bien sʼisoler de la masse quand on
soude dans des endroits humides, ou sur un plancher
metallique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande
partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état
defonctionnement.
d.Ne jamais plonger le porte-électrode dans lʼeau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder
parce que la tension entre les deux pinces peut être le
total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions
pour le porte-électrode sʼapplicuent aussi au pistolet de
soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger
contre les chutes dans le cas ou on recoit un choc. Ne jamais
enrouler le câble-électrode autour de nʼimporte quelle partie
du corps.
5. Toujours porter des lunettes de sécurité dans la zone de
soudage. Utiliser des lunettes avec écrans lateraux dans les
zones où lʼon pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de
prévenir tout risque dʼincendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de
la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque dʼincendie.
8. Sʼassurer que la masse est connectée le plus prés possible
de la zone de travail quʼil est pratique de le faire. Si on place
la masse sur la charpente de la construction ou dʼautres
endroits éloignés de la zone de travail, on augmente le risque
de voir passer le courant de soudage par les chaines de levage, câbles de grue, ou autres circuits. Cela peut provoquer
des risques dʼincendie ou dʼechauffement des chaines et des
câbles jusquʼà ce quʼils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles
galvanisées plombées, ou cadmiées ou tout autre métal qui
produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant
dʼopérations de dégraissage, nettoyage ou pistolage. La
chaleur ou les rayons de lʼarc peuvent réagir avec les vapeurs
du solvant pour produire du phosgéne (gas fortement toxique)
ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté,
voir le code “Code for safety in welding and cutting” CSA
Standard W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
3. Un coup dʼarc peut être plus sévère quʼun coup de soliel,
donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi quʼun verre blanc afin de se protéger les yeux du rayonnement de lʼarc et des projections quand on soude ou
quand on regarde lʼarc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de
lʻarc.
c. Protéger lʼautre personnel travaillant à proximité au
soudage à lʼaide dʼécrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de lʼarc de
soudage. Se protéger avec des vêtements de protection libres
de lʼhuile, tels que les gants en cuir, chemise épaisse, pantalons sans revers, et chaussures montantes.
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de
lʼélectricité et aux recommendations du fabricant. Le dispositif
de montage ou la piece à souder doit être branché à une
bonne mise à la terre.
2. Autant que possible, Iʼinstallation et lʼentretien du poste seront
effectués par un électricien qualifié.
3. Avant de faires des travaux à lʼinterieur de poste, la debrancher à lʼinterrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur
place.
Page 6
SAFETY
Electromagnetic Compatibility (EMC)
Conformance
Products displaying the CE mark are in conformity with European Community Council Directive of 15 Dec
2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility,
2004/108/EC. It was manufactured in conformity with a national standard that implements a harmonized
standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment.
It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.
Introduction
All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be
transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions
are received by other equipment, electrical interference may result. Electrical emissions may affect many
kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled
machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions
may be required when a welding power source is used in a domestic establishment.
Installation and Use
The user is responsible for installing and using the welding equipment according to the manufacturer’s
instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the
welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases
this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it
could involve construction of an electromagnetic screen enclosing the power source and the work complete
with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where
they are no longer troublesome.
vv
Note: The welding circuit may or may not be earthed for safety reasons according to national codes.
Changing the earthing arrangements should only be authorized by a person who is competent to access whether the changes will increase the risk of injury, e.g., by allowing parallel
welding current return paths which may damage the earth circuits of other equipment.
Assessment of Area
Before installing welding equipment the user shall make an assessment of potential electromagnetic problems in the surrounding area. The following shall be taken into account:
a) other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the
welding equipment;
b) radio and television transmitters and receivers;
c) computer and other control equipment;
d) safety critical equipment, e.g., guarding of industrial equipment;
e) the health of the people around, e.g., the use of pacemakers and hearing aids;
f) equipment used for calibration or measurement
g) the immunity of other equipment in the environment. The user shall ensure that other equipment being
used in the environment is compatible. This may require additional protection measures;
h) the time of day that welding or other activities are to be carried out.
Page 7
SAFETY
Electromagnetic Compatibility (EMC)
The size of the surrounding area to be considered will depend on the structure of the building and other
activities that are taking place. The surrounding area may extend beyond the boundaries of the premises.
Methods of Reducing Emissions
Mains Supply
Welding equipment should be connected to the mains supply according to the manufacturer’s recommendations. If interference occurs, it may be necessary to take additional precautions such as filtering of the mains
supply. Consideration should be given to shielding the supply cable of permanently installed welding equipment, in metallic conduit or equivalent. Shielding should be electrically continuous throughout its length. The
shielding should be connected to the welding power source so that good electrical contact is maintained
between the conduit and the welding power source enclosure.
Maintenance of the Welding Equipment
The welding equipment should be routinely maintained according to the manufacturer’s recommendations.
All access and service doors and covers should be closed and properly fastened when the welding equipment is in operation. The welding equipment should not be modified in any way except for those changes
and adjustments covered in the manufacturers instructions. In particular, the spark gaps of arc striking and
stabilizing devices should be adjusted and maintained according to the manufacturer’s recommendations.
vivi
Welding Cables
The welding cables should be kept as short as possible and should be positioned close together, running at
or close to floor level.
Equipotential Bonding
Bonding of all metallic components in the welding installation and adjacent to it should be considered.
However, metallic components bonded to the work piece will increase the risk that the operator could
receive a shock by touching these metallic components and the electrode at the same time. The operator
should be insulated from all such bonded metallic components.
Earthing of the Workpiece
Where the workpiece is not bonded to earth for electrical safety, not connected to earth because of its size
and position, e.g., ships hull or building steelwork, a connection bonding the workpiece to earth may reduce
emissions in some, but not all instances. Care should be taken to prevent the earthing of the workpiece
increasing the risk of injury to users, or damage to other electrical equipment. Where necessary, the connection of the workpiece to earth should be made by a direct connection to the workpiece, but in some countries
where direct connection is not permitted, the bonding should be achieved by suitable capacitance, selected
according to national regulations.
Screening and Shielding
Selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems of interference. Screening of the entire welding installation may be considered for special
applications
1.
_________________________
1
Portions of the preceding text are contained in EN 60974-10: “Electromagnetic Compatibility (EMC) product standard for arc welding equipment.”
Page 8
Thank You
viivii
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln
Electric for advice or information about their use of our products. We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customerʼs particular purpose,
with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any
warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control
of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in
applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com
for any updated information.
CUSTOMER ASSISTANCE POLICY
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.
Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet
accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
“Product Registration”. Please complete the form and submit your registration.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
Page 9
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.
2
Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the
magnitude of current increases.
Environmentally Hardened: -4°F to 104°F (-20°C to 40°C)
IP23 155º(F) Insulation Class
* Weight does not include input cord.
Thermal tests have been performed at ambient temperature. The duty cycle (duty factor) at 40°C has
been determined by simulation.
STORAGE TEMPERATURE RANGE
Environmentally Hardened: -40°F to 185°F (-40°C to 85°C)
POWER WAVE® C300 CE
Page 13
A-3
INSTALLATION
A-3
SAFETY PRECAUTIONS
Read this entire installation section before you
start installation.
WARNING
ELECTRIC SHOCK can kill.
• Only qualified personnel should
perform this installation.
• Turn the input power OFF at the
disconnect switch or fuse box before working on
this equipment. Turn off the input power to any
other equipment connected to the welding system
at the disconnect switch or fuse box before working on the equipment.
• Do not touch electrically hot parts.
• Always connect the POWER WAVE® C300 CE
grounding lug (located inside the reconnect
input access door) to a proper safety (Earth)
ground.
Both handles should be used when lifting POWER WAVE®
C300 CE. When using a crane or overhead device a lifting strap
should be connected to both handles. Do not attempt to lift the
POWER WAVE® C300 CE with accessories attached to it.
Do not weld with the POWER WAVE® C300 CE while the
machine is suspended by the handles.
WARNING
• Lift only with equipment of adequate lifting
capacity.
• Be sure machine is stable when lifting.
• Do not operate machine while suspended
when lifting.
The POWER WAVE® C300 CE will operate in harsh environments. Even so, it is important that simple preventative
measures are followed in order to assure long life and reliable operation.
• The machine must be located where there is free circulation of clean air such that air movement in the back, out
the sides and bottom will not be restricted.
• Dirt and dust that can be drawn into the machine should
be kept to a minimum. The use of air filters on the air
intake is not recommended because normal air flow may
be restricted. Failure to observe these precautions can
result in excessive operating temperatures and nuisance
shutdown.
• Keep machine dry. Shelter from rain and snow. Do not
place on wet ground or in puddles.
• Do not mount the POWER WAVE® C300 CE over combustible surfaces. Where there is a combustible surface
directly under stationary or fixed electrical equipment,
that surface shall be covered with a steel plate at least
.060” (1.6mm) thick, which shall extend not less than
5.90” (150mm) beyond the equipment on all sides.
TILTING
Place the machine directly on a secure, level surface or on a
recommended undercarriage. The machine may topple over if
this procedure is not followed.
INPUT AND GROUND CONNECTIONS
Only a qualified electrician should connect the POWER
WAVE® C300 CE. Installation should be made in accordance
with the appropriate National Electrical Code, all local codes
and the information in this manual.
MACHINE GROUNDING
The frame of the welder must be grounded. A ground terminal
marked with a ground symbol is located next to the input
power connection block.
See your local and national electrical codes for proper grounding methods.
HIGH FREQUENCY PROTECTION
The EMC classification of the POWER WAVE® C300 CE is
Industrial, Scientific and Medical (ISM) group 2, class A. The
POWER WAVE® C300 CE is for industrial use only. (See
Electromagnetic Compatibility EMC Safety Section).
Locate the POWER WAVE® C300 CE away from radio controlled
machinery. The normal operation of the POWER WAVE® C300 CE
may adversely affect the operation of RF controlled equipment,
which may result in bodily injury or damage to the equipment.
POWER WAVE® C300 CE
Page 14
A-4
INSTALLATION
INPUT CONNECTION
WARNING
Only a qualified electrician should
connect the input leads to the
POWER WAVE® C300 CE.
Connections should be made in
accordance with all local and
national electrical codes and the connection diagram located on the inside of the reconnect
access door of the machine. Failure to do so may
result in bodily injury or death.
A-4
WARNING
The POWER WAVE® C300 CE
ON/OFF switch is not intended as a
service disconnect for this equipment. Only a qualified electrician
should connect the input leads to
the POWER WAVE® C300 CE.
Connections should be made in accordance with
all local and national electrical codes and the connection diagram located on the inside of the
reconnect access door of the machine. Failure to
do so may result in bodily injury or death.
The supply cable provided with the Power Wave C300
CE is rated for 450 VAC (line-to-neutral). Replace the
supply cable in accordance with all national and local
codes when operating at higher voltages.
A 15 ft. (4.6m) power cord is provided and wired into
the machine.
Single Phase Input not supported.
Three Phase Input
Connect green/yellow lead to ground per National
Electric Code.
Connect grey, brown and black leads to power.
INPUT FUSE AND SUPPLY WIRE
CONSIDERATIONS
Refer to Specification Section for recommended fuse,
wire sizes and type of the copper wires. Fuse the
input circuit with the recommended super lag fuse or
delay type breakers (also called "inverse time" or
"thermal/magnetic" circuit breakers). Choose input
and grounding wire size according to local or national
electrical codes. Using input wire sizes, fuses or circuit breakers smaller than recommended may result in
"nuisance" shut-offs from welder inrush currents, even
if the machine is not being used at high currents.
Only a qualified electrician should
connect the input leads to the
POWER WAVE® C300 CE.
Connections should be made in
accordance with all local and
national electrical codes and the
connection diagram located on the inside of the
reconnect access door of the machine. Failure to
do so may result in bodily injury or death.
If the input power cord is damaged or needs to be
replaced an input power connection block is located in
the access panel under the wire spool.
ALWAYS CONNECT THE POWER WAVE
GROUNDING LUG (LOCATED INSIDE THE
ACCESS PANEL) TO A PROPER SAFETY (EARTH)
GROUND.
FIGURE A.1
INPUT VOLTAGE SELECTION
The POWER WAVE® C300 CE automatically adjusts
to work with different input voltages. No reconnect
switches settings are required.
POWER WAVE® C300 CE
Page 15
A-5
INSTALLATION
A-5
RECOMMENDED WORK CABLE
SIZES FOR ARC WELDING
A work cable is provided with the POWER WAVE®
C300 CE. This cable is appropriately sized for all of
the POWER WAVE® C300 CEʼs welding procedures.
If the work cable needs to be replaced a similar quality
of cable should be used as excessive voltage drops
caused by undersized welding cables can result in
unsatisfactory welding performance. Always use the
largest work cables that is practical, and be sure all
connections are clean and tight.
Note: Excessive heat in the weld circuit indicates
undersized cables and/or bad connections.
REMOTE SENSE LEAD SPECIFICATIONS
Since the POWER WAVE® C300 CE has the ability to
be in close proximity to the welding arc, the POWER
WAVE® C300 CE does not require the use of remote
sense leads.
SEMI-AUTOMATIC WELDING
POLARITY
The Fast Mate adapter is permanently wired for
Electrode Positive welding for all GMAW and FCAW
processes.
The polarity for GTAW and SMAW processes is
determined by connecting the electrode lead to either
the + or – output stud on the front of the machine
POWER WAVE® C300 CE
Page 16
A-6
INSTALLATION
CABLE CONNECTION
There is one circular connection on the front of the
machine.
(See Figure A.2---Table A.1)
FIGURE A.2
Function
TABLE A.1
PIN
A-6
Wiring
12 pin connector
for Push pull
guns; foot pedal;
remote controls;
Hand –amptrols.
CABLE INDUCTANCE AND ITS
EFFECTS ON WELDING
Whenever possible always weld in a direction
away from the work (ground) connection.
Excessive cable inductance will cause the welding
performance to degrade. There are several factors
that contribute to the overall inductance of the cabling
system including cable size, and loop area. The loop
area is defined by the separation distance between
the electrode and work cables, and the overall welding
loop length. The welding loop length is defined as the
total of length of the electrode cable (A) + work cable
(B) + work path (C) (see Figure A.3).
A
B
C
D
E
F
G
H
J
K
L
M
Remote Pot Common
Remote Pot +10VDC
ArcLink Peripheral Sense
To minimize inductance always use the appropriate
size cables, and whenever possible, run the electrode
and work cables in close proximity to one another to
minimize the loop area. Since the most significant factor in cable inductance is the welding loop length,
avoid excessive lengths and do not coil excess cable.
For long work piece lengths, a sliding ground should
be considered to keep the total welding loop length as
short as possible.
For additional Safety information regarding the electrode and work cable set-up, See the standard
“SAFETY INFORMATION” located in the front of this
Instruction Manual.
CANL
CANH
Remote Pot Wiper
Trigger
Trigger
Power Common
Power +
Motor Negative
Motor Positive
FIGURE A.3
A
B
POWER WAVE® C300 CE
C
WORK
Page 17
A-7
INSTALLATION
A-7
SHIELDING GAS CONNECTION
WARNING
CYLINDER may explode if
damaged.
• Keep cylinder upright and
chained to support.
• Keep cylinder away from areas where it may be
damaged.
• Never lift welder with cylinder attached.
• Never allow welding electrode to touch cylinder.
• Keep cylinder away from welding or other live
electrical circuits.
• BUILD UP OF SHIELDING GAS MAY
HARM HEALTH OR KILL.
• Shut off shielding gas supply when not
in use.
• See American National Standard Z-49.1, "Safety
in Welding and Cutting” Published by the
American Welding Society.
Customer must provide a cylinder of shielding gas, a
pressure regulator, a flow control valve, and a hose from
the flow valve to the gas inlet fitting of the wire drive unit.
Connect a supply hose from the gas cylinder flow valve
outlet to the 5/8-18 female inert gas fitting on the back
panel of the
POWER WAVE® C300 CE.
5. Attach one end of the inlet hose to the outlet fitting of
the flow regulator. Attach the other end to the welding
system shielding gas inlet. Tighten the union nuts with
a wrench.
6. Before opening the cylinder valve, turn the regulator
adjusting knob counterclockwise until the adjusting
spring pressure is released.
7. Standing to one side, open the cylinder valve slowly a
fraction of a turn. When the cylinder pressure gage
stops moving, open the valve fully.
8. The flow regulator is adjustable. Adjust it to the flow
rate recommended for the procedure and process
being used before making a weld.
MAXIMUM INLET PRESSURE IS 100 PSI. (6.9 BAR.)
Install the shielding gas supply as follows:
1. Secure the cylinder to prevent it from falling.
2. Remove the cylinder cap. Inspect the cylinder valves
and regulator for damaged threads, dirt, dust, oil or
grease. Remove dust and dirt with a clean cloth. DO
NOT ATTACH THE REGULATOR IF OIL, GREASE
OR DAMAGE IS PRESENT! Inform your gas supplier
of this condition. Oil or grease in the presence of high
pressure oxygen is explosive.
3. Stand to one side away from the outlet and open the
cylinder valve for an instant. This blows away any dust
or dirt which may have accumulated in the valve outlet.
4. Attach the flow regulator to the cylinder valve and
tighten the union nut(s) securely with a wrench. Note:
if connecting to 100% CO2cylinder, insert regulator
adapter between regulator and cylinder valve. If
adapter is equipped with a plastic washer, be sure it is
seated for connection to the CO2cylinder.
POWER WAVE® C300 CE
Page 18
A-8
INSTALLATION
A-8
LOADING SPOOLS OF WIRE
WARNING
• Keep hands, hair, clothing and tools away from
rotating equipment.
A K468 spindle adapter is required for 8" (203.2mm)
spools.
1. Squeeze the release bar on the retaining collar and
remove it from the spindle.
2.
Place the spindle adapter on the spindle, aligning
the spindle brake pin with the hole in the adapter.
3. Place the spool on the spindle and align the
adapter brake tab with one of the holes in the back
side of the spool. An indicator mark on the end of
the spindle shows the orientation of the brake tab.
Be certain the wire feeds off of the spool in the
proper direction.
PROCEDURE TO INSTALL DRIVE
ROLLS AND WIRE GUIDES
WARNING
• Turn the input power OFF at the
welding power source before installation or changing drive rolls and/or
guides.
• Do not touch electrically live parts.
• When inching with the gun trigger, electrode and
drive mechanism are "hot" to work and ground
and could remain energized several seconds
after the gun trigger is released.
• Do not operate with covers, panels or guards
removed or open.
• Only qualified personnel should perform maintenance work.
3. Remove the outer wire guide by turning the knurled
thumbscrews counter-clockwise to unscrew them
from the feed plate.
Rotate the triangular lock and remove the drive
4.
rolls. (See Figure A.5)
FIGURE A.5
4. Re-install the retaining collar. Make sure that the
release bar snaps out and that the retaining collar
fully engages the groove on the spindle.
Loading 16 to 44 lb. (7.3 – 20kg) Spools
1. Squeeze the release bar on the retaining collar and
remove it from the spindle.
2. Place the spool on the spindle, aligning the spindle
brake pin with one of the holes in the back side of
the spool. An indicator mark on the end of the spindle shows the orientation of the brake holding pin.
Be certain the wire feeds off of the spool in the
proper direction.
3. Re-install the retaining collar. Make sure that the
release bar snaps out and that the retaining collar
fully engages the groove on the spindle
5. Remove the inner wire guide.
6. Insert the new inner wire guide, groove side out,
over the two locating pins in the feed plate.
7. Install a drive roll on each hub assembly secure
with the triangular lock.
8. Install the outer wire guide by aligning it with the
pins and tightening the knurled thumbscrews.
9. Close the idle arm and engage the idle roll pressure
arm. Adjust the pressure appropriately.
GUN USED
The Magnum 350 PRO is the recommended gun for
the POWER WAVE® C300 CE. Refer to the Magnum
Proʼs operators manual for installation instructions.
POWER WAVE® C300 CE
Page 19
A-9
INSTALLATION
FEEDING ELECTRODE AND BRAKE
ADJUSTMENT
DRIVE ROLL PRESSURE SETTING
ELECTRIC SHOCK can kill.
• Turn the input power OFF at the welding power source before installation or
changing drive rolls and/or guides.
• Do not touch electrically live parts.
• When feeding with the gun trigger, unless
“COLD FEED” trigger mode is selected, the electrode and drive mechanism are always “HOT” to
work and ground and could remain “HOT” several seconds after the gun trigger is released.
• Do not operate with covers, panels or guards
removed or open
• Only qualified personnel should perform maintenance work.
The POWER WAVE® C300 CEʼs optimum drive roll
pressure varies with type of wire, surface condition,
lubrication, and hardness. Too much pressure could
cause birdnesting”, but too little pressure could cause
wire feed slippage with load and/or acceleration. The
optimum drive roll setting can be determined as follows:
A-9
PRESSURE ARM ADJUSTMENT
The pressure arm controls the amount of force the drive
rolls exert on the wire. Proper adjustment of pressure
arm gives the best welding performance.
Set the pressure arm as follows (See Figure A.6):
Aluminum wiresbetween 1 and 3
Cored wiresbetween 3 and 4
Steel, Stainless wiresbetween 4 and 6
FIGURE A.6
Cored wires
FLUX CORE
ARC WELDING
1
3
5
2
4
6
ALUMINUM
GAS METAL
ARC WELDING
Aluminum wires
Steel, Stainless wires
Turn the Reel or spool until the free end of the
1.
electrode is accessible.
2. While tightly holding the electrode, cut off the bent
end and straighten the first 6" (150 mm). Cut off
the first 1" (25 mm). (If the electrode is not properly
straightened, it may not feed or may jam causing a
"birdnest".)
3. Insert the free end through the incoming guide
tube.
4. Press the Cold Inch key and push the electrode
into the drive roll.
5. Feed the electrode through the gun.
6. Adjust the brake tension with the thumbscrew on
the spindle hub, until the reel turns freely but with
little or no overrun when wire feeding is stopped.
Do not over tighten.
POWER WAVE® C300 CE
Page 20
A-10
INSTALLATION
A-10
TIG WELDING
(Figure A.7)
When TIG (GTAW) welding with the Power Wave
C300CE, a torch with an integral gas valve is
required.
FIGURE A.7
(OPTIONAL)
FOOT AMPTROL
RECEPTACLE
TO REMOTE CONTROL
TIG TORCH
GAS HOSE
CONNECTION
TO GAS SUPPLY
POWER CABLE
STUD (-)
TO NEGATIVE
WORK PIECE
WORK CLAMP
STUD (+)
TO POSITIVE
SMAW WELDING
Most SMAW welding procedures use Electrode
Positive welding. For these applications, connect the
stick electrode holder to the positive (+) output stud
and connect the work clamp to the negative (-) output
stud.
Some SMAW welding procedures use Electrode
Negative Polarity. For these applications, connect the
stick electrode holder to the negative (-) output stud
and connect the work clamp to the positive (+) output
stud.
WORK CLAMP
WORK PIECE
POWER CABLE
TO POSITIVE
STUD (+)
TIG TORCH
TO NEGATIVE
STUD (-)
TO GAS SUPPLY
CONNECTION
GAS HOSE
TO REMOTE CONTROL
RECEPTACLE
FOOT AMPTROL
(OPTIONAL)
POWER WAVE® C300 CE
Page 21
B-1
OPERATION
B-1
SAFETY PRECAUTIONS
READ AND UNDERSTAND ENTIRE SECTION
BEFORE OPERATING MACHINE.
WARNING
• ELECTRIC SHOCK CAN KILL.
Unless using COLD FEED feature, when feeding with gun trigger, the electrode and drive
mechanism are always electrically energized and could
remain energized several seconds after the welding ceases.
• Do not touch electrically live part or electrode
with skin or wet clothing.
• Insulate yourself from work and ground.
• Always wear dry insulating gloves.
• Do not operate with covers, panels or guards
removed or open.
When the POWER WAVE® C300 CE is powered it
can take as long as 30 seconds for the machine to be
ready to weld. During this time period the user inter-
face will not be active.
DUTY CYCLE
The POWER WAVE® C300 CE is rated at 250 amps
at 26.5 volts with a 100% duty cycle. It is further rated
to provide 300 amps at 29 volts with a 40% duty cycle.
The duty cycle is based on a ten-minute period. A
40% duty cycle represents 4 minutes of welding and 6
minutes of idling in a ten-minute period.
POWER WAVE® C300 CE
Page 22
B-2
OPERATION
PRODUCT DESCRIPTION
The POWER WAVE® C300 CE is a high performance
multi-process machine with GMAW, FCAW, SMAW,
DC TIG, and pulse capability. It will offer a premier
welding performance solution for specific areas such
as aluminum, stainless, nickel where size and weight
are an issue.
The POWER WAVE® C300 CE will provide the following:
B-2
PROCESS LIMITATIONS
The software based weld tables of the POWER WAVE®
C300 CE limit the process capability within the output range
and the safe limits of the machine. In general the processes
will be limited to .025-.045 solid steel wire, .035-.045 stainless wire, .035-.052 cored wire, and .035 and 3/64
Aluminum wire. 1/16 Aluminum wire is not supported.
The following items will not be supported on this product,
but may be supported by other product in the product portfolio:
• Power - 300A @ 40%, 250A @ 100%.
• Multi Input Voltage with no reconnect - 200-600V,
50-60 Hz input.
• Three Phase Power.
• < 95% Power factor – optimizes available electrical
capacity.
• Environmentally Hardened - IP23 rated for operating
in difficult environments.
• Ethernet connectivity – allows access to the Power
Wave utilities software tools.
RECOMMENDED PROCESSES AND
EQUIPMENT
RECOMMENDED PROCESSES
The POWER WAVE® C300 CE is a high speed, multiprocess power source capable of regulating the current,
voltage, or power of the welding arc. With an output range of
5 to 300 amperes, it supports a number of standard
processes including synergic GMAW, GMAW-P, FCAW,
FCAW-SS, SMAW, GTAW and GTAW-P on various materials especially steel, aluminum and stainless steel.
• STT
• AC welding processes
WARNING
The POWER WAVE® C300 CE is not recommended for
pipe thawing.
• Maximum gun length is 25 ft (7.6m) for push-only
systems.
• Maximum gun length is 50 ft (15.2) for push-pull
systems.
• Maximum spool size is 12 in (305 mm) diameter.
• Maximum spool weight is 44 lb (20 kg).
• The Fast Mate Adapter is integral to the machine
and cannot be changed to other gun bushings
• Wire welding processes are limited to positive polarity only.
• Does not operate on single phase power
The following capabilities are supported:
• Push-pull (12-pin) connection - Panther™ and Cougar™.
• Spool gun connection (K2490-1 and K2519-1).
• Remote foot pedal (K870) or hand amptrol (K963-3) via a
12-pin connection.
• Standard MIG gun trigger connection, Integrated in Euro
Connector.
• The Gun bushing with Euro Connector installed. Cannot
be changed to other gun bushings.
• Watercooler, Integral CoolArc 50.
• Simple process to switch between different welding
processes.
POWER WAVE® C300 CE
Page 23
B-3
OPERATION
B-3
DESIGN FEATURES
Loaded with Standard Features
• Multiple process DC output range: 5 - 300 Amps.
• 208 – 575 VAC, 3 phase, 50-60Hz input power.
• New and Improved Line Voltage Compensation
holds the output constant over wide input voltage
fluctuations.
• Utilizes next generation microprocessor control,
based on the ArcLink® platform.
• State of the art power electronics technology, yields
superior welding capability.
• Electronic over current protection.
• Input over voltage protection.
• F.A.N. (fan as needed). Cooling fan runs when the
output is energized 15 seconds following the strike of
the welding arc and will continue to run 5 minutes
following the end of the weld.
• Thermostatically protected for safety and reliability.
• Recessed connection panel for protection against
accidental impact.
• Ethernet connectivity.
• Panel mounted Status and Thermal LED indicators
facilitate quick and easy troubleshooting.
• Potted PC boards for enhanced ruggedness/reliabili-
ty.
• Enclosure reinforced with heavy duty aluminum
extrusions for mechanical toughness.
• Push-Pull ready for welding aluminum.
• Remote control/Foot amptrol ready.
• Waveform Control Technology™ for good weld
appearance and low spatter, even when welding
nickel alloys.
• 8 memories for easily selecting procedures.
• Full sequence control for tailoring the weld from start
to end.
• Patented MAXTRAC™ 2 roll drive system.
• Patent pending drive rolls improve traction on solid
wire by up to 20%.
• The precision machined, rigid aluminum alloy frame
results in maximum drive roll clamping pressure.
• Patented split wire guides fully support the wire and
virtually eliminate birdnesting.
• No tools required to change the drive rolls and wire
guides.
• Patented dual spring pressure arms have sensitivity
for feeding soft wires without crushing them, and
have plenty of compression force for feeding solid
or stiff wires.
• All gear driven rolls for more feeding force.
• Brass-to-brass connections between the electrode
connection and the gun minimize voltage drop variations, resulting in consistent arc performance all
day, every day.
• Powerful, quiet motor with integrated tachometer for
accurate WFS regulation.
POWER WAVE® C300 CE
Page 24
B-4
CASE FRONT CONTROLS
7
14
6
13
5
12
11
4
10
3
9
2
8
1
1
2
3
4
5
OPERATION
FIGURE B.1
B-4
8
9
10
11
12
13
6
7
All operator controls and adjustments are located on
the case front of the Power Wave. (See Figure B.1)
1. LEFT DISPLAY- Shows wire feed speed or amper-
age,
2. LEFT KNOB- Adjusts value in left display.
3. MAIN DISPLAY- Shows detailed welding and diag-
nostic information.
4. LEFT BUTTON- Changes the Main display to
show the Weld Mode or UltimArc™ Control or
Memories.
5. ON/OFF SWITCH- Controls power to the Power
Wave C300CE.
14
9. RIGHT KNOB- Adjusts value in right display.
10. THERMAL LIGHT- Indicates when machine has
thermal fault.
11. SET-UP- Lights when machine is in set-up mode,
12. RIGHT BUTTON- Changes the Main display to
arc start, arc end and trigger options.
13. MAIN KNOB- Changes the values on the Main
display.
14. 12 PIN CONNECTOR- Connection for push pull
guns, remotes.
6. + OUTPUT STUD- Connection for electrode posi-
tive.
7. - OUTPUT STUD- Connection for electrode nega-
tive.
8. RIGHT DISPLAY- Shows voltage or trim.
POWER WAVE® C300 CE
Page 25
B-5
CASE BACK CONTROLS
3
2
1
4
OPERATION
FIGURE B.2
1
B-5
4
2
1. ETHERNET CONNECTOR
2. POWER CORD
3. GAS CONNECTION
4. CIRCUIT BREAKER
3
POWER WAVE® C300 CE
Page 26
B-6
OPERATION
INTERNAL CONTROLS
B-6
1
2
1
3
FIGURE B.3
2
3
1. SPINDLE BRAKE
2. WIRE DRIVE PRESSURE ARM
3.
COLD INCH / GAS PURGE SWITCH
POWER WAVE® C300 CE
Page 27
B-7
OPERATION
B-7
MAKING A WELD WITH WAVEFORM
TECHNOLOGY POWER SOURCES
WARNING
MAKING A WELD
The serviceability of a product or structure utilizing the
welding programs is and must be the sole responsibility of
the builder/user. Many variables beyond the control of The
Lincoln Electric Company affect the results obtained in
applying these programs. These variables include, but are
not limited to, welding procedure, plate chemistry and temperature, weldment design, fabrication methods and service requirements. The available range of a welding program may not be suitable for all applications, and the
build/user is and must be solely responsible for welding
program selection.
Choose the electrode material, electrode size, shielding gas,
and process (GMAW, GMAW-P etc.) appropriate for the material to be welded.
Select the weld mode that best matches the desired welding
process. The standard weld set shipped with the Power Wave
C300 encompasses a wide range of common processes that
will meet most needs. If a special weld mode is desired, contact the local Lincoln Electric sales representative.
All adjustments are made through the user interface. Because
of the different configuration options your system may not have
all of the following adjustments. Regardless of availability, all
controls are described in the following section ( See Figure B.4
Panel Controls Used)
WIRE FEED SPEED (WFS)
In synergic welding modes (synergic CV, GMAW-P), WFS is the
dominant control parameter. The user adjusts WFS according
to factors such as wire size, penetration requirements, heat
input, etc. The Power Wave then uses the WFS setting to
adjust the voltage and current according to settings contained in
the Power Wave.
In non-synergic modes, the WFS control behaves like a conventional power source where WFS and voltage are independent
adjustments. Therefore, to maintain proper arc characteristics,
the operator must adjust the voltage to compensate for any
changes made to the WFS.
AMPS
In constant current modes, this control adjusts the welding current.
VOLTS
In constant voltage modes, this control adjusts the welding voltage.
TRIM
In pulse synergic welding modes, the Trim setting adjusts the
arc length. Trim is adjustable from 0.50 to 1.50. 1.00 is the
nominal setting and is a good starting point for most conditions.
ULTIMARC
UltimArcTMControl allows the operator to vary the arc characteristics from “soft” to “crisp”. UltimArc™Control is adjustable
from –10.0 to +10.0 with a nominal setting of 0.0.
TM
CONTROL
DEFINITION OF WELDING MODES
NON-SYNERGIC WELDING MODES
• A Non-synergic welding mode requires all welding process
variables to be set by the operator.
SYNERGIC WELDING MODES
• A Synergic welding mode offers the simplicity of single knob
control. The machine will select the correct voltage and
amperage based on the wire feed speed (WFS) set by the
operator.
BASIC WELDING CONTROLS
WELD MODE
Selecting a weld mode determines the output characteristics of
the Power Wave power source. Weld modes are developed
with a specific electrode material, electrode size, and shielding
gas. For a more complete description of the weld modes programmed into the Power Wave at the factory, refer to the Weld
Set Reference Guide supplied with the machine or available at
www.powerwavesoftware.com.
POWER WAVE® C300 CE
Page 28
B-8
Arc Control
End Options
Weld Mode
Start Options
Memories
M
4T
Trigger Options
AMPS
OFF
AMPS
ON
LESS
MORE
OUTPUT
OUTPUT
+
+
Amps
A
Trim
V
Volts
Wire Feed Speed (WFS)
Wire Feed Speed (WFS)
Amps
OPERATION
B-8
CASE FRONT CONTROLS USED
Vol ts
V
A
+
+
Trim
Memories
Weld Mode
Arc Control
LESS
AMPS
4T
OUTPUT
ON
Trigger Options
MORE
AMPS
OUTPUT
OFF
M
Start Options
End Options
POWER WAVE® C300 CE
Page 29
B-9
OPERATION
SMAW (STICK) WELDING
SMAW is most often used for outdoor construction,
pipe welding and general repairs. The POWER
WAVE® C300 CE controls Amperage, Output Control
and Arc Force during SMAW welding.
During SMAW welding the wire drive remains idle.
BASIC OPERATION
B-9
CC STICK MODES
PROCESS
Stick Soft(7018)
Stick Crisp(6010)
Stick Pipe
MODE
1
2
3
OUTPUT
ON
V
200
A
+
LESS
AMPS
MORE
AMPS
OUTPUT
OFF
OFF
+
CONTROL OPTIONS
START OPTIONS
EFFECT / RANGE
START TIME:
0 TO 10 Seconds
If no remote control is installed,
this control sets the time for the
DESCRIPTION
weld output to ramp up or down
from a preset Start current to
the preset Weld current. Use
the WFS/AMP knob to adjust
Start current while the Start
Options LED is lit.
1
Stick
Soft 7018
M
4T
UltimArc™ Control
EFFECT / RANGE
ARC FORCE
(Soft)-10.0 to
(Crisp)+10.0
DESCRIPTION
Arc
Force adjusts the short circuit current for a soft arc, or for
a forceful, driving arc. Lower
values will provide less short
circuit and softer arc. Higher
settings will provide a higher
short circuit, a more forceful arc
and possibly more spatter.
POWER WAVE® C300 CE
END OPTIONS
No arc ending options are active for
SMAW
(Stick) Welding.
Page 30
B-10
OPERATION
NON-SYNERGIC GMAW AND FCAW
WELDING
In non-synergic modes, the WFS control is similar to a
conventional CV power source where WFS and voltage are independent adjustments. Therefore to maintain the arc characteristics, the operator must adjust
the voltage to compensate for any changes made to
the WFS.
B-10
UltimArc™Control, adjusts the apparent inductance of
the wave shape. The UltimArc™Control adjustment is
similar to the “pinch” function in that it is inversely proportional to inductance. Therefore, increasing
UltimArc™Control greater than 0.0 results in a crisper
arc (more spatter) while decreasing the
UltimArc™Control to less than 0.0 provides a softer
arc (less spatter).
put turns off.
gas flows after the welding out-
0 To 10.0 Seconds
Postflow Time
the time that shielding
Adjusts
wire for the next arc start.
and prepares the end of the
wire from sticking in the puddle
stops feeding. It prevents the
output continues after the wire
amount of time that the weld
0 To 0.25 Seconds
The burnback time is the
Burnback:
the Crater Procedure.
from the Weld Procedure to
machine will ramp up or down
During the Crater time, the
after the trigger is released.
time at the end of the weld
WFS and Volts for a specified
Crater ProcedureCrater Procedure controls the
(Crisp)+10.
0
effect in 4 Step trigger mode.
-ristics when short-arc welding.
(Soft)-10.0 to
still pulled. The option has no
Pinch controls the arc characte-
PINCH
0 To 120.0 Seconds
continue even if the trigger is
DESCRIPTION
EFFECT / RANGE
Spot Timer:
Adjusts the time welding will
UltimArc™ Control
EFFECT DESCRIPTION
END OPTIONS
M
4T
STD CV
Gas Shld
5
Procedure.
FCAW, (GS) STANDARD CV
7
to the preset Welding
FCAW, (SS) STANDARD CV
6
down from the Start Procedure
GMAW, POWER MODE
40
the machine will ramp up or
the weld. During the start time,
GMAW, STANDARD CV
5
fied time at the beginning of
PROCESS
WELD MODE
the WFS and Volts for a speciThe Start Procedure controls
Start Procedure
WELD MODE
lished.
is pulled until an arc is estabspeed from the time the trigger
.
Off, .076 To 3.81 in/min
Run-In sets the wire feed
Run-In WFS
:
andprior to feeding wire.
flowsafter the trigger is pulled
0 To 10 Seconds
that
Preflow Time
Adjusts the time
shielding gas
DESCRIPTION
EFFECT
START OPTIONS
AMPS
ON
AMPS
OFF
LESS
MORE
OUTPUT
OUTPUT
+
+
A
4.5020.0
V
WELD MODE
PROCESS
GMAW, STANDARD CV
GMAW, POWER MODE
FCAW, (SS) STANDARD CV
FCAW, (GS) STANDARD CV
BASIC OPERATION
4.50
A
+
LESS
AMPS
CONTROL OPTIONS
WELD MODE
5
40
6
7
M
MORE
AMPS
Gas Shld
5
STD CV
20.0
+
OUTPUT
OFF
OUTPUT
ON
EFFECT
Preflow Time
0 To 10 Seconds
Run-In WFS
Off, .076 To 3.81 in/min
Start Procedure
4T
V
START OPTIONS
:
DESCRIPTION
Adjusts the
flows
and
time
that
shielding
after the trigger is
prior to feeding wire.
Run-In sets the wire feed
speed from the time the trigger
.
is pulled until an arc is established.
The Start Procedure controls
the WFS and Volts for a specified time at the beginning of
the weld. During the start time,
the machine will ramp up or
down from the Start Procedure
to the preset Welding
Procedure.
gas
pulled
EFFECT / RANGE
PINCH
(Soft)-10.0 to
(Crisp)+10.
0
UltimArc™ Control
DESCRIPTION
Pinch controls the arc characte-
-ristics when short-arc welding.
POWER WAVE® C300 CE
EFFECT
Spot Timer:
0 To 120.0 Seconds
Crater Procedure
Burnback:
0 To 0.25 Seconds
Postflow Time
0 To 10.0 Seconds
END OPTIONS
DESCRIPTION
Adjusts the time welding will
continue even if the trigger is
still pulled. The option has no
effect in 4 Step trigger mode.
Crater Procedure controls the
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.
The burnback time is the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Adjusts
the time that shielding
gas flows after the welding out
put turns off.
-
Page 31
B-11
OPERATION
B-11
GMAW (MIG) SYNERGIC WELDING
In synergic welding modes, WFS is the dominant control
parameter. For each wire feed speed, a corresponding voltage is programmed into the machine at the factory. The
user adjusts WFS according to factors such as wire size,
material thickness, penetration requirements, etc. The
Power Wave then uses the WFS setting to select the appropriate voltage. The voltage selected will be a nominal voltage. The user can adjust the voltage higher or lower to
compensate for material condition or individual preference.
UltimArc™Control, adjusts the apparent inductance of the
wave shape. The UltimArc™Control adjustment is similar to
the “pinch” function in that it is inversely proportional to
inductance. Therefore, increasing UltimArc™Control
greater than 0.0 results in a crisper arc (more spatter) while
decreasing the UltimArc™Control to less than 0.0 provides
a softer arc (less spatter).
BASIC OPERATION
CONTROL OPTIONS
ELECTRODE AND GAS
Steel
Steel
Stainless
Stainless
Aluminum 4043
Aluminum 5356
CO
Ar(Mix)
Ar(Mix)
Ar/He/CO
Ar
Ar
WELD MODE
2
2
4.50
A
+
LESS
AMPS
.08 .09 1.0 1.2
93
94 15 11 21
61 29 31 41
63 --- --- ---
--- --- --- 71
--- --- 151 75
MORE
AMPS
WIRE SIZE
14 10 20
OUTPUT
OFF
Synergic CV programs feature an ideal voltage best
suited for most procedures. Use this voltage as a
starting point and adjust if needed for personal preferences.
When the voltage knob is rotated, the display will
show an upper or lower bar indicating if the voltage is
above or below the ideal voltage.
• Preset voltage above ideal
voltage. (upper bar displayed)
• Preset voltage at ideal
voltage. (no bar displayed)
• Preset voltage below ideal
voltage. (lower bar displayed)
OUTPUT
ON
V
START OPTIONS
DESCRIPTION
Adjusts the time
gas
flows
pulled and
Run-In sets the wire feed
speed from the time the trigger
is pulled until an arc is established.
The Start Procedure controls
the WFS, Volts at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.
that shielding
after the
trigger
prior to feeding.
is
20.0
+
EFFECT
Preflow Time:
0 To 10 Seconds
Run-in WFS:
Off, 0.76 to 3.81 m/min.
Start Procedure
EFFECT / RANGE
PINCH EFFECT
(-10.0 to +10.0)
UltimArc™ Control
DESCRIPTION
Pinch controls the arc characte-
-ristics when short-arc welding.
POWER WAVE® C300 CE
M
10
STEEL 1.0mm
CV CO2
-
4T
EFFECT
Spot Timer
0 to 120.0 Seconds
Crater Procedure
Burnback:
0 to 0.25 Seconds
Postflow Time
0 to 10 Seconds
END OPTIONS
DESCRIPTION
Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.
Crater Procedure controls the
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.
The burnback time is the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Adjusts the time that shielding
gas flows after the welding output turns off.
Page 32
B-12
gg
g
g
OPERATION
STEEL AND STAINLESS SYNERGIC GMAW-P (PULSED MIG) WELDING
When pulse welding, the power source primarily regulates the arc current, not the arc voltage. During a
pulsing cycle, arc current is regulated from a low
background level to a high peak level and then back
down to the low background level. The average arc
voltage increases and decreases as the average arc
current is increased or decreased. The peak current,
back ground current, rise time, fall time and pulse frequency all affect the average voltage. Since the average voltage for a given wire feed speed can only be
determined when all the pulsing waveform parameters
are known, a unitless value called “trim” is used for
adjusting the arc length.
Trim adjusts the arc length and ranges from 0.50 to
1.50 with a nominal value of 1.00. Increasing the trim
value increases the arc length. Decreasing the trim
value decreases the arc length.
Pulse welding modes are synergic; using wire feed
speed as the main control parameter. As the wire
feed speed is adjusted, the power source adjusts the
waveform parameters to maintain good welding characteristics. Trim is used as a secondary control to
change the arc length for material conditions or individual preference. (See
Figure B.5)
B-12
th Short
Arc LenArc Len
th Medium
Arc LengthLongTrim .50Trim 1.00
Trim 1.50
Trim .50
Arc Len
th Short
FIGURE B.5
Trim 1.00
Arc Len
ULTIMARC™CONTROL
(See Figure B.6)
UltimArc™Control adjusts the focus or shape of the arc.
UltimArc™Control is adjustable from -10.0 to +10.0 with
a nominal setting of 0.0. Increasing the arc control
increases the pulse frequency and background current
while decreasing the peak current.
Medium Frequencyand Width
Low Frequency, WideHigh Frequency, FocusedUltimArc™ Control-10.0 OFF
UltimArc™ Control+10.0
UltimArc™ Control
FIGURE B.6
Trim 1.50
th Medium
Arc Length Long
This results in a tight, stiff arc used for high speed sheet
metal welding. Decreasing the arc control decreases the
pulse frequency and background current while increasing
the peak current. This results in a soft arc good for out of
position welding.
UltimArc™ Control -1 0 .0
Low F requency, Wide
UltimArc™ Control
Med ium Frequency and Wi dth
The Power Wave utilizes adaptive control to compensate
for changes in the electrical stick-out(distance from the
contact tip to the work piece) while welding. The Power
Wave waveforms are optimized for a 5/8” to 3/4” stick out
OF F
UltimArc™ Control
High Frequency, Focused
The adaptive behavior supports a range of stick outs
from approximately 1/2” to 1-1/4”. At low or high wire
feed speeds, the adaptive range may be less due to
physical limitations of the welding process.
Run-in sets the wire feed
speed from the time the trigger
is pulled until an arc is established.
The Start Procedure controls
the WFS, Trim at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.
is
EFFECT / RANGE
ARC FOCUS
-10.0 (SOFT to
10.0 (STIFF)
UltimArc™ Control
DESCRIPTION
Arc Focus adjusts the arc from
a wide, soft arc good for out of
position work to a narrow, stiff
arc preferred for faster travel
speeds. The pulse frequency is
lower with a soft arc and higher
with a stiff arc.
EFFECT
Spot Timer
0 to 120.0 Seconds
Crater Procedure
Burnback:
0 to 0.25 Seconds
Postflow Time
0 to 10 Seconds
END OPTIONS
FUNCTION
Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.
Crater Procedure controls the
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.
The burnback time is the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Adjusts the time that shielding
gas flows after the welding out-
put turns off.
POWER WAVE® C300 CE
Page 34
B-14
OPERATION
B-14
ALUMINUM SYNERGIC GMAW-P
(PULSED MIG)AND GMAW-PP
(PULSE ON PULSE) WELDING
The POWER WAVE® C300 CE can produce top quality aluminum welds with excellent appearance, little
spatter and good bead shape. Push-pull guns are
available for consistent feeding when welding a long
distance away from the wire feeder.
PULSE-ON-PULSE WELDING
The Power Wave system offers both traditional pulse
and Pulse-on-Pulse™. Pulse-on-Pulse (GMAW-PP)
is an exclusive waveform for aluminum welding. Use
it to make welds with a "stacked dime" appearance,
similar to GTAW welds.( See Figure B.7)
FIGURE B.7
ALUMINUM GMAW-P AND GMAW-PP
ALUMINUM PULSE WELDING
Synergic GMAW-P (Pulsed MIG) welding is ideal for
low spatter, out of position and reduced heat input
applications. During pulse welding, the welding current continuously switches from a low level to a high
level and then back again. Each pulse sends a small
droplet of molten metal from the wire to the weld puddle.
Pulse welding controls the arc length with 'Trim'
instead of voltage. When trim (arc length) is adjusted,
the Power Wave automatically recalculates the voltage, current and time of each part of the pulse waveform for the best result. Trim adjusts the arc length
and ranges from 0.50 to 1.50, with a nominal value of
1.00 for a 3/4" (19mm) electrode stick-out. Trim values
greater than 1.00 increase the arc length, while values
less than 1.00 decrease the arc length.
(See Figure B.10)
FIGURE B.10
The pulsing frequency is adjustable. Changing the frequency modulation (or arc control) of the waveform
changes the ripple spacing. Faster travel speeds may
be achieved by using higher values of frequency modulation. ( See Figure B.8 and B.9p)
FIGURE B.8
Frequency Modulation = -10
Wide weld and ripple spacing, slow travel speed.
FIGURE B.9
Trim .50
Arc Length Short
Trim 1.00
Arc Length Medium
Trim 1.50
Arc L ength Long
Frequency Modulation = 10
Narrow weld and ripple spacing, fast travel speed.
POWER WAVE® C300 CE
Page 35
B-15
OPERATION
ALUMINUM GMAW-P (PULSED MIG)
AND GMAW-PP (PULSE ON PULSE)
WELDING
BASIC OPERATION
B-15
WELDMODES
ELECTRODE AND GAS
ALUMINUM 4043 Pulse
ALUMINUM 4043 Pulse -on-Pulse Ar
ALUMINUM 5356
ALUMINUM 5356 Pulse -on-Pulse Ar
Ar
Ar
WFS
AMPS
Less
Deposition
1.0 1.2
4.5
+
More
Deposition
Shorter
Arc
CONTROL OPTIONS
WIRE SIZE
--- 72
--- 99
76 152
101102
72
Aluminum1.2mm
Pulse 4043 Ar
M
0.0
+
VOLTS
TRIM
Longer
Arc
STARTOPTIONS
EFFECT
Preflow Time
0to10Seconds
RUN-IN WFS:
OFF, 0.76 to 3.81m/mm
Start Procedure
4T
DESCRIPTION
Adjusts the time that shielding
gas
flows
pulled
and
Run- in sets the wire feed
speed fromthetimethetriggeris pulleduntil an arc is estab-
lished.
The Start Procedure controls
the WFS. Trim at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
For Pulsechanges the pulsing frequency.
Whenthe frequency changes,
the Power Wave system automa tically adju st s the background current to mainta in a
similar heat input into the weld.
Low frequencies give more control over the puddle and high
frequencies minimize spatter.
For Pulse -On-Pulsemodes,
Arc controls changes the frequency modulation. The freque-
-ncy modulationcontrols the
spacingof theripples inthe
weld. Use low values for slow
travel speeds and wide welds,
andhigh values for fasttravel
speeds andnarrower welds.
modes, Arc Control
EFFECT
END OPTIONS
Spot Timer
0 to 120.0 Seconds
Crater Procedure
Burnback:
0to0.25Seconds
Postflow Time
0to10Seconds
FUNCTION
Adju st the time we lding will
continue e ven i f the trigger
is still pu lled. This op tion
has no effect in 4-Step
Trigger Mode.
Crater Procedurecontrols the
WFS and Volts for a specifiedtime attheendof the wel d
afterthetriggeris released.
Duringthe Cr ater time, themachine will ramp up ordown
fromthe Weld Procedure to
the Crater Procedure.
The burnbac k time i s the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from stickinginthe puddle
and prepares theendof the
wire forthenext arc start.
Adjusts the time that shielding
gas flows after the welding out-
put turns off.
POWER WAVE® C300 CE
Page 36
B-16
OPERATION
GTAW (TIG) WELDING
The POWER WAVE® C300 CE is excellent for
(Touch Start TIG) welding.
BASIC OPERATION
B-16
WFS
AMPS
WELD MODE
MODE
TOUCH START 3
UltimArc™ Control
No UltimArc™ Control are
active for Touch Start TIG.
50
+
CONTROL OPTIONS
3
TOUCH START TIG
M
OUTPUT
ON
OFF
+
The Start Procedure controls the
Amperage at a fixed level for the
set amount of time.
4T
No Arc starting Options are
active for Touch Start TIG
VOLTS
TRIM
OUTPUT
OFF
START OPTIONS
END OPTIONS
WELD MODE SEARCHING
The Weld Mode Search feature allows the selection of
a welding mode based on certain criteria (wire size,
process type, etc.).
SEARCHING FOR A WELD MODE
To search for a mode, turn the control knob until
“Weld Mode Search” is displayed. This will appear in
between the highest and the lowest weld mode numbers.
Once “Weld Mode Search” is displayed, pressing the
right pushbutton labeled “Begin” will start the search
process.
POWER WAVE® C300 CE
During the search process, pressing the right pushbutton typically acts as a “next” button and the left pushbutton typically acts as a “back” button.
Rotate the control knob then press the right pushbutton to select relevant welding details such as welding
process, wire type, wire size, etc.
When the final selection is made, the C300
TM
will
automatically change to the weld mode found by the
Weld Mode Search process.
Earlier products may not have this feature. To activate this feature, a software update may be needed
from www.powerwavesoftware.com
Page 37
B-17
OPERATION
B-17
SAVING A MEMORY:
To save the current machine settings to the selected
memory, press and hold the center knob for (2 sec-onds). After two seconds, the alphanumeric displays
will show “Memory # Save Memory” at which time
the center knob should be released. After saving to a
memory, a message will briefly appear indicating that
the selected memory has been saved.
1. Press the Left Push Button until Memory 'M'
LED is illuminated.
M
4T
CO2
CV
1.2mm
Steel
“M Led”
Job1
+
+
A
20.0
4.50
V
V
4T
“M Led”
4.50
A
+
20.0
+
Job1
Steel
CV
M
1.2mm
CO2
RECALLING A MEMORY
To recall the selected memory, press and hold center knob for (1 second). After recalling a memory, a
message will briefly appear indicating that the selected memory has been recalled. The Memory LED will
remain lit so that the user can quickly recall a different
memory if needed.
1. Press the Left Push Button until Memory 'M'
LED is illuminated.
M
4T
CO2
CV
1.2mm
Steel
“M Led”
Job1
+
+
A
15.5
5.00
V
V
4T
“M Led”
5.00
A
+
15.5
+
Job1
Steel
CV
M
1.2mm
CO2
2. Rotate center knob to cycle to desired memory
2. Rotate center knob to cycle to desired memory
location.
M
4T
Ar Mix
Pulse
1.0mm
Stainless
Job4
+
+
A
20.0 4.50
V
A
+
20.0 4.50
+
V
Job4
Stainless
Pulse
M
3. Press and hold center knob for 2 seconds. The active
procedure will be saved into the selected memory.
2Secondstosave Memory”
“Pressand Hold Knob
M
4T
RecalledMemory 4
+
+
A
20.0
4.50
V
4.50
A
+
Memory 4
Recalled
M
1.0mm
Ar Mix
20.0
+
4T
3. Press and hold center knob for 1 second. The
V
4T
location.
M
4T
Ar Mix
Pulse
1.0mm
Stainless
Job4
+
+
A
20.0 4.50
V
A
+
20.0 4.50
+
Job4
Stainless
Pulse
M
selected memory is now active.
1 second. Memory is active.
Press and Hold Knob for
M
4T
RecalledMemory 4
+
+
A
20.0
4.50
V
4.50
A
+
Memory 4
Recalled
M
1.0mm
Ar Mix
20.0
+
V
4T
V
4T
Press
“Press and Hold Knob
2 Seconds to save Memory”
2 SECONDS
POWER WAVE® C300 CE
Press and Hold Knob for
1 second. Memory is active.
1 SECOND
Press
Page 38
B-18
OPERATION
LIMITS
Limits allow the welder to adjust the welding procedure only within a defined range.
Each user memory may have a different set of limits.
For example, memory 1 can be set to limit the WFS to
200 through 300 in/min, and memory 2 can be set to
limit the WFS to 275 through 310 in/min, while memory 3 may not have any WFS limits.
Parameters are always constrained by machine limits.
When memory limits are enabled, the parameter will
flash whenever an attempt is made to exceed the
memory limit value. The parameter will not flash if an
attempt is made to exceed the machine limit.
B-18
Press the Left Push Button until Memory 'M' LED
is illuminated.
M
4T
Ar Mix
CV
1.2mm
Steel
“M Led”
Job1
+
+
A
V
V
4T
“M Led”
A
+
+
Job1
Steel
CV
M
1.2mm
Ar Mix
The system machine limits are:
Parameter
Wire Feed Speed
Voltage
Trim
UltimArc™Control
Preflow
Start Time
Run-In WFS
Crater Time
Burnback Time
Postflow Time
Range
Weld mode and wire
feeder dependent.
Weld mode dependent
0.50 to 1.50
-10.0 to 10.0
0.0 to 2.5
0.0 to 10.0
Off, 50 to 150
0.0 to 10.0
0.00 to 0.25
0.0 to 10.0
Limits may be set for:
• Wire Feed Speed/Amperage
• Voltage/Trim
• UltimArcTM Control
Units
in/min
Volts
--
Weld mode dependent
Seconds
Seconds
in/min
Seconds
Seconds
Seconds
Rotate center knob to cycle to desired memory.
M
4T
Ar Mix
Pulse
1.0mm
Stainless
Job4
+
+
A
V
A
+
+
V
Job4
Stainless
Pulse
M
Press and hold center knob for 5 seconds. The
Set Limits Menu will be active.
5 second. Limits is active.
Press and Hold Knob for
M
4T
Set LimitsMemory 4
+
+
A
V
A
+
1.0mm
Ar Mix
+
4T
V
Weld modes cannot be selected through the Limits
Setup menu, and must be chosen and saved to memory before entering the Limits Setup Menu.
POWER WAVE® C300 CE
Memory 4
Set Limits
M
PRESS
4T
Press and Hold Knob for
5 second. Limits is active.
5 SECONDS
Page 39
B-19
OPERATION
B-19
1. Rotate center knob to select parameter to be set
(WFS, Voltage, Trim).
M
4T
Weld WFS
Low 0.76
Hi=21.99
5.00
+
+
A
V
V
A
+
+
5.00
Hi=21.99
M
Weld WFS
2. Press the Left pushbutton to select the limit to
be set (High, Nominal, Low). The selected value
will blink.
M
4T
Weld WFS
Low 8.00
Hi=10.00
“M Led”
8.00
+
+
A
V
A
+
Low 0.76
4T
V
+
4. Press the left push button to confirm changes
(or press the right push button to cancel).
Confirm
√
Cancel
M
4T
Saved
Memory 4 limits
“M Led”
+
+
A
V
V
A
+
+
“M Led”
Memory 4 limits
√
Confirm
M
Saved
4T
Cancel
WELD MODE SEARCH
The Weld Mode search function allows for a particular
mode to be selected based on the process, wire type
and wire size.
1. Press the Left Push Button until Weld Mode
LED is illuminated.
M
4T
Weld Mode
STD Cv
Gas Shld
5
+
+
A
20.0
4.50
V
Hi=10.00
8.00
Weld WFS
Low 8.00
4T
“M Led”
M
3. Once all limits have been set, press and hold for
1 second, release the center knob to accept.
changes.
1 second. Accepts changes.
Press and Hold Knob for
M
4T
No
Yes
Limits?
Save
+
+
A
V
A
+
Save
Yes
M
+
Limits?
No
Press and Hold Knob for
1 second. Accepts changes.
1 SECOND
Press
V
4T
4.50
A
+
20.0
+
V
5
Gas Shld
Weld Mode
M
2. Press and hold the center knob for 1 second
release center knob. The Weld Mode search
menu will be active.
1 second. Weld Mode is active.
Press and Hold Knob for
M
4T
Pulse MIG GMAW-P
Select Process
+
+
A
V
A
+
Select Process
Pulse MIG GMAW-P
M
STD Cv
4T
V
+
4T
Press and Hold Knob for
1 second. Weld Mode is active.
POWER WAVE® C300 CE
1 SECOND
Press
Page 40
B-20
OPERATION
B-20
3. Rotate center knob to cycle to desired process.
M
4T
Power Mode
Select Process
+
+
A
V
V
A
+
M
Select Process
Power Mode
+
4T
4. Press the right Push Button to select the
process. If necessary, repeat steps 3 and 4 to
select wire type, wire size, and final selection.
M
4T
Power Mode
40
+
+
A
15.5
5.00
V
5.00
A
+
15.5
+
V
2-STEP 4-STEP- TRIGGER
OPERATION
The 2-Step - 4-Step switch changes the function of
the gun trigger. 2-Step trigger operation switches the
welding output ON-OFF in direct response to the trigger. 4-Step trigger operation provides 'trigger interlock' capability and gives the ability to control the
amount of time spent in the arc start and arc crater
steps.
Press the right push button on the case front to toggle
between 2-Step and 4-Step operation.
The 2-Step, 4-Step trigger has no effect when weld-
ing with SMAW.
4T
2-Step Trigger
2-Step trigger operation is the most common. When
the gun trigger is pulled, the welding system (power
40
Power Mode
M
4T
source and wire feeder) cycles through the arc starting sequence and into the main welding parameters.
The welding system will continue to weld as long as
the gun trigger is activated. Once the trigger is
released, the welding system cycles through the arc
ending steps
4-Step Trigger
4-Step trigger operation gives the welder additional
control in the welding sequence. 4-Step trigger allows
the welder to choose the arc start, weld and arc end
time. It may also be set-up to work as a trigger interlock.
POWER WAVE® C300 CE
Page 41
B-21
OPERATION
EXAMPLE 1 - 2 STEP TRIGGER: Simple operation
The simplest trigger operation occurs with a 2 Step
trigger and the Start, Crater and Burnback functions
all set to OFF. (See Figure B.11)
For this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the
gun trigger is pulled.
RUN-IN:
After preflow time expires, the power source regulates
to the welding output and wire is advanced towards
the work piece at the Run-In WFS. If an arc is not
established within 1.5 seconds, the wire feed speed
will jump to the welding wire feed speed
WELD:
The power source output and the wire feed speed
continue at the weld settings for as long as the trigger
is pulled.
POSTFLOW:As soon as the trigger is released, the
power source output and the wire feed speed are
turned OFF. Shielding gas continues until the post
flow timer expires.
B-21
OffRun-in
WFS
Weld
Off
Output
1.5 secmax.
SourcePower
Weld
Off
GasShielding
On
IdlePreflowRun-InWeldPostflowIdle
Arc Trigger
Trigger
Established
Released
Pulled
Burnback = OFFCrater =OFFStart =OFF2 Step Trigger
Shie lding
Gas
Powe r
Source
Output
On
Off
Wel d
Off
Wel d
Pulled
Trigger
IdlePrefl ow
Run-In
1.5 sec max.
FIGURE B.11
2 Step Trigger
Start = OFF
Crater = OFF
Burnback = OFF
Established
Arc
Released
Trigger
WeldPostflowIdle
WFS
Run-in
Off
POWER WAVE® C300 CE
Page 42
B-22
OPERATION
B-22
EXAMPLE 2 - 2 STEP TRIGGER: Improved Arc Start
and Arc End. Tailoring the arc start and arc end is a
common method for reducing spatter and improving
weld quality. This can be accomplished with the Start
and Burnback functions set to a desired values and
Crater set to OFF. (See Figure B.12)
For this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the
gun trigger is pulled.
RUN-IN:
After preflow time expires, the power source regulates
to the start output and wire is advanced towards the
work piece at the Run-In WFS. If an arc is not established within 1.5 seconds, the power source output
and wire feed speed skips to the weld settings.
FIGURE B.12
2 Step Trigger
Start = ON
Crater = OFF
Burnback = ON
UPSLOPE:
Once the wire touches the work and an arc is established, both the machine output and the wire feed
speed ramp to the weld settings throughout the start
time. The time period of ramping from the start settings to the weld settings is called UPSLOPE.
WELD:
After upslope, the power source output and the wire
feed speed continue at the weld settings.
BURNBACK:
As soon as the trigger is released, the wire feed
speed is turned OFF and the machine output continues for the burnback time.
POSTFLOW:
Next, the machine output is turned OFF and shielding
gas continues until the post flow timer expires.
Shieldi n
Gas
Pow er
Source
Output
WFS
g
Run-in
OCV
Weld
Sta rt
Weld
On
Off
Off
Off
Pulled
Trigger
IdlePreflow
Run-In
1.5 s ec max.
Released
Established
Arc
UpslopeWeldBurnbackPostflowIdle
Start
time
Trigger
Burnback Time
POWER WAVE® C300 CE
Page 43
B-23
OPERATION
EXAMPLE 3 - 2 STEP TRIGGER: Customized Arc
Start, Crater and Arc End. Sometimes it is advantageous to set specific arc start, crater and arc ending
parameters for the ideal weld. Many times when
welding aluminum crater control is necessary to make
a good weld. This is done by setting Start, Crater
and Burnback functions to desired values. (See
Figure B.13)
For this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the
gun trigger is pulled.
RUN-IN:
After preflow time expires, the power source regulates
to the start output and wire is advanced towards the
work piece at the Run-In WFS. If an arc is not established within 1.5 seconds, the power source output
and wire feed speed skips to the weld settings.
START & UPSLOPE:
As soon as the trigger is pulled, this starts preflow.
The Strike arc established, Start time, and Upslope
parameters are used at the beginning of the weld
sequence to establish a stable arc and provide a
smooth transition to the weld settings.
B-23
WELD:
After upslope, the power source output and the wire
feed speed continue at the weld settings.
CRATER & DOWNSLOPE:
As soon as the trigger is released, the wire feed
speed and power source output ramp to the crater
settings throughout the crater time. The time period of
ramping from the weld settings to the crater settings is
called DOWNSLOPE.
BURNBACK:
After the crater time expires, the wire feed speed is
turned OFF and the machine output continues for the
burnback time.
POSTFLOW:
Next, the machine output is turned OFF and shielding
gas continues until the post flow timer expires.
The 4 step trigger can be configured as a trigger interlock. Trigger interlock adds to the welderʼs comfort
when making long welds by allowing the trigger to be
released after an initial trigger pull. Welding stops
when the trigger is pulled a second time and then
released, or if the arc is interrupted. (See Figure B.14)
For this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the
gun trigger is pulled.
RUN-IN:
After preflow time expires, the power source regulates
to the welding output and wire is advanced towards
the work piece at the Run-In WFS. If an arc is not
established within 1.5 seconds, the wire feed speed
will jump to the welding wire feed speed.
WELD:
The power source output and the wire feed speed
continue at the weld settings. Welding continues when
the trigger is pulled a second time.
B-24
Shielding
Gas
Power
Source
Output
POSTFLOW:
As soon as the trigger is released for the second time,
the power source output and the wire feed speed are
turned OFF. Shielding gas flows until the post flow
timer expires.
Pulled
Trigger
dlePreflow StrikeWel
I
On
Off
We l d
1. 5 s e c ma x .
Start
Crat er
Off
Established
Arc
FIGURE B.14
4 Step Trigge r
Start = OFF
Crater = OFF
Burnback = OF F
Released
Trigger
Pulled
Trigger
d
Released
Trigger
Burnb ack PostflowIdle
WFS
We l d
Cra ter
Ru n-in
Off
POWER WAVE® C300 CE
Page 45
B-25
OPERATION
EXAMPLE 5 - 4 STEP TRIGGER: Manual control of
Start and Crater times with Burnback ON. The 4 step
trigger sequence gives the most flexibility when the
Start, Crater and Burnback functions are active. This
is a popular choice when welding aluminum because
extra heat may be needed during Start and less heat
desired during crater. With 4 step trigger, the welder
chooses the amount of time to weld at the Start, Weld
and Crater settings by using the gun trigger. Burnback
reduces the occurrence of wire to sticking into the
weld pool at the end of a weld and conditions the end
of the wire for the next arc start. ( See Figure B.15)
In this sequence,
PREFLOW:
Shielding gas begins to flow immediately when the
gun trigger is pulled.
RUN-IN:
After preflow time expires, the power source regulates
to the start output and wire is advanced towards the
work piece at the run-in WFS. If an arc is not established within 1.5 seconds, the power source output
and wire feed speed skips to the weld settings.
START:
The power source welds at the start WFS and voltage
until the trigger is released.
B-25
UPSLOPE:
During upslope, the power source output and the wire
feed speed ramp to the weld settings throughout the
start time. The time period of ramping from the start
settings to the weld settings is called UPSLOPE.
WELD:
After upslope, the power source output and the wire
feed speed continue at the weld settings.
DOWNSLOPE:
As soon as the trigger is pulled, the wire feed speed
and power source output ramp to the crater settings
throughout the crater time. The time period of ramping from the weld settings to the crater settings is
called DOWNSLOPE.
CRATER:
During CRATER, the power source continues to supply output at the crater WFS and voltage.
BURNBACK:
When the trigger is released, the wire feed speed is
turned OFF and the machine output continues for the
burnback time.
POSTFLOW:
Next, the machine output is turned OFF and shielding
gas continues until the post flow timer expires.
Cold Feed and Gas Purge are combined into a single spring centered toggle switch.
To activate Cold Feeding, hold the
switch in the UP position. The wire
drive will feed electrode but neither the power source
nor the gas solenoid will be energized. Adjust the
speed of cold feeding by rotating the WFS knob.
Cold feeding, or "cold inching" the electrode is useful
for threading the electrode through the gun.
Hold with toggle switch in the DOWN position to activate Gas Purge and let the shielding gas flow. The
gas solenoid valve will energize but neither the power
source output nor the drive motor will be turned on.
The Gas Purge switch is useful for setting the proper
flow rate of shielding gas. Flow meters should always
be adjusted while the shielding gas is flowing.
COLD FEED
GAS PURGE
POWER WAVE® C300 CE
Page 47
B-27
OPERATION
B-27
SETUP MENU FEATURES
The Setup Menu gives access to the Setup Configuration. Stored in the setup configuration are user parameters
that generally only need to be set at installation. The parameters are grouped as shown in the following table.
PARAMETER
P.1 through P.99
P.101 through P.199
P.501 through P.599
1. To access the set-up menu, press the Right and
2. After changing a parameter it is necessary to press
3. To exit the set-up menu at any time, press the
DEFINITION
Unsecured Parameters (always adjustable)
Diagnostic Parameters (always read only)
Secured Parameters (only accessible through a p.c. or palm application)
SET-UP FEATURES MENU
(See Figure B.16)
Left buttons of the Main Display panel simultane-
ously. Note that the set-up menu cannot be
accessed if the system is welding, or if there is a
fault (The status LED is not solid green).
Change the value of the blinking parameter by rotating the SET knob.
the Right hand button to save the new setting.
Pressing the Left button will cancel the change.
Right and Left buttons of the Main Display panel
simultaneously. Alternately, 1 minute of inactivity
will also exit the set-up menu.
FIGURE B.16 - SETUP MENU
SET Knob
button
button
Right
Left
Mode
Set-Up
LED
Main Display Panel
Mode Select
Mode Select
Main Display Panel
LED
Set-Up
Mode
Left
button
Right
button
SET Knob
POWER WAVE® C300 CE
Page 48
B-28
OPERATION
USER DEFINED PARAMETERS
ParameterDefinition
Exit Setup Menu
P. 0
This option is used to exit the setup menu. When P.0 is displayed, press the Left Button to exit
the setup menu.
P.1Wire Feed Speed Units
This option selects which units to use for displaying wire feed speed.
English = inches/minute wire feed speed units (default).
Metric = meters/minute wire feed speed units.
P.2Arc Display Mode
This option selects what value will be shown on the upper left display while welding.
Amps = The left display shows Amperage while welding (default).
WFS = The left display shows Wire Feed Speed while welding.
P.3Display Options
This setup parameter was previously named "Display Energy"
B-28
If the previous software revision had this parameter set to display energy, that selection will
remain.
This option selects the information displayed on the alphanumeric displayes while welding. Not
all P.3 selections will be available on all machines. In order for each selection to be included in
the list, the power source must support that feature. A software update of the power source may
be needed to include the features.
Standard Display = The lower displays will continue to show preset information during and after
a weld (default).
Show Energy = Energy is displayed, along with time in HH:MM:SS format.
Show Weld Score = The accumulative weld score result is shown.
P.4Recall Memory with Trigger
This option allows a memory to be recalled by quickly pulling and releasing the gun trigger. To
recall a memory, quickly pull and release the trigger the number of times that correspond to the
memory number. For example, to recall memory 3, quickly pull and release the trigger 3 times.
To recall memory 1, quickly pull and release the trigger the number of user memories plus 1.
Memories cannot be recalled while the system is welding.
Disabled = The gun trigger cannot be used to recall user memories (default).
Enabled = The gun trigger can be used to recall user memories.
POWER WAVE® C300 CE
Page 49
B-29
OPERATION
USER DEFINED PARAMETERS
ParameterDefinition
P.5Procedure Change Method
Selects how remote procedure selection (A/B) will be made. The selected procedure can be
changed locally at the user interface by pressing the 'A-Gun-B' button. The following methods
can be used to remotely change the selected procedure:
• Use an external switch wired to the procedure select input.
• Quickly releasing and re-pulling the gun trigger.
• Using a dual-schedule gun which incorporates a procedure select switch in the trigger mechanism (pulling the trigger more than half way changes the procedure from A to B).
The possible values for this parameter are:
• External Switch = Procedure selection may only be performed at the memory panel or an
external switch (e.g. K683).
• Quick Trigger = The selected procedure can be changed remotely by releasing and re-pulling
the trigger quickly while welding. This feature is disabled in 4-Step trigger mode. The external
procedure switch is disabled. To operate:
1. Select "GUN" on the memory panel.
2. Start the weld by pulling the gun trigger. The system will weld with procedure A settings.
3. While welding, quickly release then pull the gun trigger once. The system will switch to
procedure B settings. Repeat to switch back to procedure A settings. The procedure can
be changed as many times as needed during the weld.
4. Release the trigger to stop welding. The system will automatically return to procedure A
settings.
B-29
• Integral TrigProc = When using a Magnum DS dual-schedule gun (or similar) that incorporates a procedure switch in the gun trigger mechanism. While welding in 2-step, machine
operation is identical to the "External Switch" selection. When welding in 4-step, additional
logic prevents procedure A from being re-selected when the trigger is released at step 2 of the
4-step weld sequence. The machine will always operate in 2-step if a weld is made exclusively in procedure A, regardless of the 2/4 step switch position (this is intended to simplify tack
welding when using a dual-schedule gun in 4-step).
P.6Stall Factor Adjustment
This option allows the adjustment of the stall factor in Push/Pull operation. The stall factor controls the stall torque of the push motor when using a push-pull gun. The wire feeder is factoryset to not stall unless there is a large resistance to feeding wire. The stall factor can be reduced
to stall more easily and possibly prevent bird nesting. However, low stall factors can cause
motor stalling during normal welding conditions, which results in the wire burning back to the tip
or rapid tack welds. If you are experiencing bird nests, check for other feeding problems before
adjusting the stall factor. The default value for the stall factor is 75, with a range of 5 to 100.
POWER WAVE® C300 CE
Page 50
B-30
OPERATION
USER DEFINED PARAMETERS
ParameterDefinition
P.7Gun Offset Adjustment
This option adjusts the wire feed speed calibration of the pull motor of a push-pull gun. This
should only be performed when other possible corrections do not solve any push-pull feeding
problems. An rpm meter is required to perform the pull gun motor offset calibration. To perform
the calibration procedure do the following:
1. Release the pressure arm on both the pull and push wire drives.
2. Set the wire feed speed to 200 ipm.
3. Remove wire from the pull wire drive.
4. Hold an rpm meter to the drive roll in the pull gun.
5. Pull the trigger on the push-pull gun.
6. Measure the rpm of the pull motor. The rpm should be between 115 and 125 rpm. If necessary, decrease the calibration setting to slow the pull motor, or increase the calibration setting to speed up the motor.
The calibration range is -30 to +30, with 0 as the default value.
P.8TIG Gas Control
This option allows control over which gas solenoid actuates while TIG welding.
"Valve (manual)" = No MIG solenoid will actuate while TIG welding, gas flow is manually con
trolled by an external valve.
"Solenoid (auto) = This selection only applicable to PWC300. The MIG solenoid will turn on and
off automatically while TIG welding.
"Feeder Solenoid" = No applicable to PWC300. The internal (feeder) MIG solenoid will turn on
and off automatically while TIG welding.
"Pwr Src Solenoid" = Not applicable to PWC300. Any gas solenoid connected to the power
source will turn on and off automatically while TIG welding. This selection will not appear in the
list if the power source does not support a gas solenoid.
B-30
Notes: Preflow is not available while TIG welding. Postflow is available - the same postflow
time will be used in MIG and TIG. When machine output on/off is controlled via the upper right
knob, gas flow will not start until the tungsten touches the work. Gas flow will continue when the
arc is broken until the Postflow time expires. When machine output on/off is controlled via an
arc start switch or foot Amptrol, gas will begin flowing when the output is turned on and will continue flowing until the output is turned off and the Postflow time expires.
P.9Crater Delay
This option is used to skip the Crater sequence when making short tack welds. If the trigger is
released before the timer expires, Crater will be bypassed and the weld will end. If the trigger is
released after the timer expires, the Crater sequence will function normally (if enabled).
P.14Reset Consumable Weight
Use this option to reset the initial weight of the consumable package. Press the Right Button to
reset the consumable weight. This option will only appear with systems using Production
Monitoring.
POWER WAVE® C300 CE
Page 51
B-31
OPERATION
USER DEFINED PARAMETERS
ParameterDefinition
P.16Push-Pull Gun Knob Behavior
This option determines how the potentiometer on the Push/Pull torch will behave. Gun Pot
Enabled = The welding wire feed speed is always controlled by the potentiometer on the pushpull gun (default). The left front panel knob is only used to adjust Start and Crater wire feed
speed. Gun Pot Disabled = The wire feed speed is always controlled by the left front panel
knob. This setting is useful when the operator wishes to have wire feed speed settings recalled
from memories and not have the potentiometer "overwrite" the setting. Gun Pot Proc A = When
in procedure A, the welding wire feed speed is controlled by the potentiometer on the push-pull
gun. When in procedure B, the welding wire feed speed is controlled by the left front panel
knob. This setting allows a fixed wire feed speed to be selected in procedure.
P.17Remote Control Type
This setup parameter was previously named "Spool/Push-Pull".
This option selects the type of analog remote control being used. Digital remote control
devices (those with a digital display) are configured automatically. Not all P.17 selections will
be available on all machines. When P.17 is used to configure the remote control to function in a
specific process, the remote will be ignored in other processes. For example, if P.17 = TIG
Amp Control, the remote control will only function when TIG welding - the remote will be
ignored in other processes (MIG, stick and gouge).
B-31
Spool Gun = Use this setting while MIG welding with a spool gun that uses a potentiometer
used for wire feed speed control (this setting is backward compatible with "P.17 Gun Selection"
= Standard/Spool).
Push-Pull Gun = Use this setting wile MIG welding with a push-pull gun that uses a potentiometer for wire feed speed control (this setting is backward compatible with "P.17 Gun Selection" =
PushPull).
TIG Amp Control = Use this setting while TIG welding with a foot or hand current control device
(Amptrol). While TIG welding, the upper left knob on the User Interface sets the maximum current obtained when the TIG amp control is at its maximum setting.
Stick/Gouge Rem. = Use this setting while stick welding or gouging with a remote output control
device. While stick welding, the upper left knob on the User Interface sets the maximum current
obtained when the stick remote is at itʼs maximum setting. While gouging, the upper left knob
is disabled and the gouging current is set on the remote control.
All Mode Remote = This setting allows the remote control to function in all weld modes which is
how most machines with 6-pin and 7-pin remote control connections operate. This setting was
provided so that customers with a mix of Lincoln Electric equipment can have consistent
remote control behavior across all of their equipment. (N. American default)
Joystick MIG Gun = Use this setting while MIG welding with a push MIG gun with a joystick
control. Stick, TIG and gouge welding currents are set at the User Interface. (European
default)
P.20Display Trim as Volts Options
This option determines how trim is displayed.
False = The trim is displayed in the format defined in the weld set (default).
True = All trim values are displayed as a voltage.
POWER WAVE® C300 CE
Page 52
B-32
OPERATION
USER DEFINED PARAMETERS
ParameterDefinition
P.22Arc Start/Loss Error Time
This option can be used to optionally shut off output if an arc is not established, or is lost for a
specified amount of time. Error 269 will be displayed if the machine times out. If the value is set
to OFF, machine output will not be turned off if an arc is not established nor will output be
turned off if an arc is lost. The trigger can be used to hot feed the wire (default). If a value is set,
the machine output will shut off if an arc is not established within the specified amount of time
after the trigger is pulled or if the trigger remains pulled after an arc is lost. This is disabled
while welding in Stick, TIG or Gouge. To prevent nuisance errors, set Arc Start/Loss Error Time
to an appropriate value after considering all welding parameters (run-in wire feed speed, weld
wire feed speed, electrical stick out, etc). To prevent subsequent changes to Arc Start/Loss
Error Time, the setup menu should be locked out by setting Preference Lock = Yes using the
Power Wave Manager software.
P.80Sense From Studs
Use this option for diagnostic purposes only. When power is cycled, this option is automatically
reset to False.
False = Voltage sensing is automatically determined by the selected weld mode and other
machine settings (default).
True = Voltage sensing is forced to "studs".
B-32
P.81Sense Leads Selection
Used in place of DIP switches for configuration of the work and electrode sense leads. This
option will only appear in the list if the power source has a hardware selection option. 67 pos
polarity = An electrode sense lead is connected using positive polarity. This is used by most
GMAW welding procedures.
67 neg polarity = An electrode sense lead is connected using negative polarity. This is used by
most GTAW welding procedures and some Innershield procedures.
67 & 21 = An electrode sense lead and work sense lead are connected.
Hardware Config = The hardware determines the best remote sensing configuration. This is
applicable to MIG welding procedures only.
P.82Voltage Sense Display
Allows viewing of Voltage Sense Lead Selection to aid in troubleshooting. The configuration is
displayed as a text string on the lower display whenever the output is enabled. This parameter
is not saved on a power cycle, but will be reset to False.
P.99Show Test Modes?
Most power sources contain weld modes used for calibration and test purposes. By default, the
machine does not include test weld modes in the list of weld modes that are available to the
operator. To manually select a test weld mode, set this option to "Yes". When the power source
is turned off and back on again, the test modes will no longer appear in the mode list. Test weld
modes typically require the machine output to be connected to a grid load and cannot be used
for welding.
P.100View Diagnostic?
Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select
"Yes" to access the diagnostic options in the menu. Additional parameters will now appear in
the setup menu (P.101, P.102, etc).
POWER WAVE® C300 CE
Page 53
B-33
OPERATION
USER DEFINED PARAMETERS
ParameterDefinition
P.102View Fatal Logs
Used for viewing all the system fatal logs. Press the Right Button to enter the option. Rotate
Control Knob to select the desired fatal log to read. Press the Right Button again to enter that
log. Rotating the Control Knob will scroll through the log, displaying the log index number and
fatal code. Press the Left Button to back out to select another log. Press the Left Button again
to exit this option.
P.103View Software Version Information
Used for viewing the software versions for each board in the system. Press the Right Button to
enter the option. Rotate Control Knob to select the desired board to read. Press the Right
Button again to read the firmware version. Press the Left Button to back out to select another
board. Rotate the Control Knob to select another board, or press the Left Button to exit this
option.
P.104View Hardware Version Information
Used for viewing the hardware version for each board in the system. Press the Right Button to
enter the option. Rotate Control Knob to select the desired board to read. Press the Right
Button again to read the hardware version. Press the Left Button to back out to select another
board. Press the Left Button again to exit this option.
B-33
P.105View Welding Software Information
Used for viewing the Weld Set in the Power Source. Press the Right Button to read the Weld
Set version. Press the Left Button to back out and exit this option.
P.106View Ethernet IP Address
Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to
read the IP Address. Press the Left Button to back out and exit this option. The IP address cannot be changed using this option.
P.107View Power Source Protocol
Used for viewing the type of power source the feeder is connected to. Press the Right Button to
identify the power source as either LincNet or ArcLink. Press the Left Button to back out and
exit this
P.501Encoder Lockout
Locks one or both of the upper knobs (encoders), preventing the operator from changing wire
feed speed, amps, volts or trim. The function of each upper knob depends on the selected weld
mode. When a constant current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right
knob will always function as an on/off switch. This parameter can only be accessed using
PowerWave
P.502Memory Change Lockout
Determines if the memories can be overwritten with new contents.
No = Memories can be saved and limits can be configured (default).
Yes = Memories cannot be changed - saving is prohibited and limits cannot be re-configured.
This parameter can only be accessed using Power Wave Manager software.
POWER WAVE® C300 CE
Page 54
B-34
OPERATION
USER DEFINED PARAMETERS
ParameterDefinition
P.503Memory Button Disable
Disables the specified memory button(s). When a memory is disabled, welding procedures cannot be restored from or saved to that memory. If an attempt is made to save or restore a disabled memory, a message will be displayed on the lower display indicating the memory number
is disabled. In multi-head systems, this parameter disables the same memory buttons on both
feed heads. This parameter can only be accessed using Power Wave Manager software.
P.504Mode Select Panel Lock
Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel
selection is locked and an attempt is made to change that parameter, a message will be displayed on the lower display indicating the parameter is locked.
• All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are
unlocked.
• All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked.
• Start and End Options Locked = The Start and End parameters on the Mode Select Panel are
locked, all others are unlocked.
• Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel,
all others Mode Select Panel settings are unlocked.
• Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are
locked, all others are unlocked.
• Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the
Mode Select Panel are locked, all others are unlocked.
• Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the
Mode Select Panel are locked, all others are unlocked.
• This parameter can only be accessed using Power Wave Manager software.
B-34
P.505Setup Menu Lock
Determines if the setup parameters can be modified by the operator without entering a passcode.
No = The operator can change any set menu parameter without first entering the passcode
even if the passcode is non-zero (default).
Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change
any setup menu parameters.
This parameter can only be accessed using Power Wave Manager software.
P.506Set User Interface Passcode
Prevents unauthorized changes to the equipment. The default passcode is zero which allows
full access. A nonzero passcode will prevent unauthorized: changes to memory limits, saving
to memory (if P.502 = Yes), changes to setup parameters (if P.505 = Yes).
This parameter can only be accessed using Power Wave Manager software.
P.509UI Master Lockout
Locks all user interface controls, preventing the operator from making any changes. This parameter can only be accessed using Power Wave Manager software.
POWER WAVE® C300 CE
Page 55
B-35
OPERATION
USER DEFINED PARAMETERS
ParameterDefinition
P.507UI Clear All Memories
Allows the operator to quickly set all memories to the default weld mode and welding parameters. Presently, this option does not exist in any setup menu.
P.509UI Master Lockout
Locks all user interface controls, preventing the operator from making any changes. This parameter can only be accessed using Power Wave Manager.
B-35
POWER WAVE® C300 CE
Page 56
C-1
ACCESSORIES
C-1
OPTIONS / ACCESSORIES
K857 REMOTE OUTPUT CONTROL
Portable current control provides the
same dial range as the current control on
the welder. Consists of a 6-pin Amphenol
connector which plugs into the remote
control Amphenol. 25 foot cable length.
TIG OPTIONS
Lincoln Electric offers a full line of TIG
Torches. Contact your local Lincoln
Electric sales office for more information.
K870 FOOT AMPTROL*
Depress pedal to increase current.
Depressing pedal fully achieves
maximum set current. Fully raising
the pedal finishes the weld and
starts the Afterflow cycle.
WIRE FEEDER OPTIONS
K2490-1 MAGNUM®250LX SPOOL GUN
Air-Cooled, 25 ft. 280 amps,60% duty
cycle Feeds .025”-3/64” (0.6-1.2mm)
diameter aluminum wire on 2lbs. (0.9kg.)
spool.
The Magnum 250LX spool gun is a professional grade
solution for feeding small spools of aluminum and
steel wire.
K2519-1 CONTROL CABLE EXTENSION
Extend your spool gun reach with a 25 ft.
(7.5 m) control cable extension. Features
a 7-pin female MS-type connector on the
spool gun end and a 7-pin male MS-type
connector on the power source end.
PUSH PULL GUNS
K963-3 HAND AMPTROL*
Provides 25 ft (7.6m) of remote current control for TIG welding. (6-pin
plug connection).
K814 ARC START SWITCH (25FT., 7.6m)*
CUT LENGTH CONSUMABLES
TIG welding filler metals are available
for welding stainless steel, mild steel,
aluminum and copper alloys.
* Requires K2909-1
12 pin - 6 pin Remote Adapter Cable
Lincoln Electric offers both the Cougar™ pistol grip
and Panther™ gooseneck style push-pull guns for
feeding aluminum wire. Both Air and Water cooled
versions are available. Contact your local Lincoln
Electric sales office for more information.
K1738-1 SPOOL GUN HOLDER
K2378-1 CANVAS COVER
K2734-1 POWER WAVE® C300 CE CART
WELD FUME EXTRACTORS
Lincoln Electricʼs® WELD FUME
EXTRACTORS are portable, low
vacuum/high volume self-cleaning filtration system designed for heavy
duty extraction and filtration of welding fumes. Easily wheeled around
the shop-wide central systems servicing many welding stations.
POWER WAVE® C300 CE
Page 57
D-1
MAINTENANCE
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
•Do not operate with covers
removed.
•Turn off power source before
installing or servicing.
•Do not touch electrically hot
parts.
• Turn the input power to the welding power
source off at the fuse box before working in the
terminal strip.
• Only qualified personnel should install, use or
service this equipment.
Routine maintenance consists of periodically blowing
out the machine, using a low-pressure air stream, to
remove accumulated dust and dirt from the intake and
outlet louvers, and the cooling channels in the
machine.
D-1
PERIODIC MAINTENANCE
Calibration of the POWER WAVE® C300 CE is critical
to its operation. Generally speaking the calibration will
not need adjustment. However, neglected or improperly calibrated machines may not yield satisfactory
weld performance. To ensure optimal performance,
the calibration of output Voltage and Current should
be checked yearly.
CALIBRATION SPECIFICATION
Output Voltage and Current are calibrated at the factory. Generally the machine calibration will not need
adjustment. However, if the weld performance
changes, or the yearly calibration check reveals a
problem, use the calibration section of the
Diagnostics Utility to make the appropriate adjustments.
The calibration procedure itself requires the use of a
grid, and certified actual meters for voltage and current. The accuracy of the calibration will be directly
affected by the accuracy of the measuring equipment
you use. The Diagnostics Utility includes detailed
instructions, and is available on the Service
Navigator CD or at www.powerwavesoftware.com.
POWER WAVE® C300 CE
Page 58
E-1
TROUBLESHOOTING
HOW TO USE TROUBLESHOOTING GUIDE
WARNING
Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician and
machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical
Shock, please observe all safety notes and precautions detailed throughout this manual.
This Troubleshooting Guide is provided to help you
locate and repair possible machine malfunctions.
Simply follow the three-step procedure listed below.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled “PROBLEM (SYMPTOMS)”. This column describes possible symptoms
that the machine may exhibit. Find the listing that
best describes the symptom that the machine is
exhibiting.
Step 2. POSSIBLE CAUSE.
The second column labeled “POSSIBLE CAUSE” lists
the obvious external possibilities that may contribute
to the machine symptom.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the
Possible Cause, generally it states to contact your
local Lincoln Authorized Field Service Facility.
If you do not understand or are unable to perform the
Recommended Course of Action safely, contact your
local Lincoln Authorized Field Service Facility.
WARNING
ELECTRIC SHOCK can kill.
• Turn the input power OFF at the welding power source before installation or changing
drive rolls and/or guides.
• Do not touch electrically live parts.
• When inching with the gun trigger, electrode and drive mechanism are "hot" to work and
ground and could remain energized several seconds after the gun trigger is released.
• Welding power source must be connected to system ground per the National Electrical Code or any
applicable local codes.
• Only qualified personnel should perform maintenance work.
Observe all additional Safety Guidelines detailed throughout this manual.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER WAVE® C300 CE
Page 59
E-2
TROUBLESHOOTING
USING THE STATUS LED TO
TROUBLESHOOT SYSTEM PROBLEMS
Not all of the Power Wave C300 CE errors will be displayed
on the user interface. There are three status lights that contain error sequences that may not show up on the user interface. If a problem occurs it is important to note the condition
of the status lights. Therefore, prior to cycling power to
the system, check the power source status light for
error sequences as noted below.
There are two status lights located above the wire drive in
the wire feeder compartment. One of the status lights is for
the main control board ( labeled “status”, and one for the
wire drive module. The third status light is internal and is
located on the input control board.
TABLE E.1
Light
Condition
Main control board status light and Wiredrive Status Light
E-2
There is an audible beeper associated with this input control
boardʼs status light. So the error codes on the input board
can be detected through either the status light or the status
beeper.
Included in this section is information about the Status
Lights and some basic troubleshooting charts for both
machine and weld performance.
The status lights on the main control board and the wire
drive module are dual-color LEDʼs. Normal operation for
each is steady green. Where as the status light on the input
control board is one color. Normal operation is for the status
light to be off ( and the buzzer to be off).
Error conditions are indicated in the following Table E.1.
Meaning
Input control board
Steady Green
Blinking Green
Fast Blinking Green
Alternating Green and Red
Steady Red
Blinking Red
System OK. Power source is operational, and is communicating normally with all
healthy peripheral equipment connected to its ArcLink network.
Occurs during power up or a system reset, and indicates the POWER
WAVE® C300 CE is mapping (identifying) each component in the sys-
tem. Normal for first 1-10 seconds after power is turned on, or if the
system configuration is changed during operation.
Indicates Auto-mapping has failed
Non-recoverable system fault. If the Status lights are flashing any combination of red and green, errors are present. Read the error code(s)
before the machine is turned off.
Error Code interpretation through the Status light is detailed in the
Service Manual. Individual code digits are flashed in red with a long
pause between digits. If more than one code is present, the codes will
be separated by a green light. Only active error conditions will be
accessible through the Status Light.
Error codes can also be retrieved with the Diagnostics Utility (includ-
ed on the Service Navigator CD or available at www.power-
wavesoftware.com). This is the preferred method, since it can access
historical information contained in the error logs.
To clear the active error(s), turn power source off, and back on to
reset.
Not applicable.
Not applicable.
Not applicable.
Not applicable.
Not applicable.
Not applicable.
Not applicable.
Error Code interpretation -
Individual code digits are flashed
in red with a long pause between
digits. These error codes are three
digit codes that all start with a
number three.
Status LED off
Not applicable.
System OK
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER WAVE® C300 CE
Page 60
E-3
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
E-3
ERROR CODES FOR THE POWER WAVE®
The following is a partial list of possible error codes for the POWER WAVE® C300 CE. For a complete listing
consult the Service Manual for this machine.
MAIN CONTROL BOARD ( “STATUS” LIGHT)
Error Code #
Indication
36Thermal error
54 Secondary (Output) over current error
56 Chopper communication error
58 Primary Fault error
Other
WIRE DRIVE MODULE
81 Motor Overload
Indicates over temperature. Usually accompanied by Thermal LED.
Check fan operation. Be sure process does not exceed duty cycle
limit of the machine
The long term average secondary (weld) current limit has been
exceeded. NOTE: The long term average secondary current limit is
325 amps.
Indicates communication link between main control board and
chopper has errors. If cycling the input power on the machine does
not clear the error, contact the Service Department.
Review error code from input board status light or status beeper.
Most likely caused by an over power condition which caused an
under voltage on the primary bus. If cycling the input power on the
machine does not clear the error, contact the Service Department.
Error codes that contain three or four digits are defined as fatal
errors. These codes generally indicate internal errors on the Power
Source Control Board. If cycling the input power on the machine
does not clear the error, contact the Service Department.
Long term average motor current limit has been exceeded.
Typically indicates mechanical overload of system. If problem continues consider higher torque gear ratio (lower speed range).
82 Motor Overcurrent
Absolute maximum motor current level has been exceeded. This is
a short term average to protect drive circuitry.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER WAVE® C300 CE
Page 61
E-4
Error Code #
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
INPUT CONTROL BOARD
Indication
E-4
331 Peak input current limit
333 Under-voltage lockout
336 Thermal Fault
337 Pre-charge timeout
346 Transformer primary over current
Other
Input current limit has been exceeded. Typically indicates short
term power overload. If problem persists contact Service
Department.
+15 VDC supply on Input control board too low. Verify input voltage
is within the acceptable range. If problem persists contact service
department.
Thermostat on primary module tripped. Typically caused by bottom
fan not working.
Problem with start-up sequence. If problem persists contact Service
Department.
Transformer current too high. Typically indicates short term power
overload. If problem persists contact service department.
Contact the Service Department.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER WAVE® C300 CE
Page 62
E-5
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
TROUBLESHOOTING
POSSIBLE
CAUSE
Basic Machine Problems
E-5
RECOMMENDED
COURSE OF ACTION
Input fuses keep blowing
Machine will not power up (no lights)
1. Improperly sized input fuses.
2. Improper Weld Procedure requiring output levels in excess of
machine rating.
3. Major physical or electrical damage is evident when the covers
are removed.
1. No Input Power
2. Input voltage is too low or too
high.
1. Make sure fuses are properly
sized. See installation section of
this manual for recommended
sizes.
2. Reduce output current, duty
cycle, or both.
3. Contact your local authorized
Lincoln Electric Field Service
facility for technical assistance.
1. Make sure input supply disconnect has been turned ON. Check
input fuses. Make certain that the
Power Switch (SW1) on the
power source is in the “ON” position.
2. Make certain that input voltage is
correct, according to the Rating
Plate located on the rear of the
machine.
Machine wonʼt weld, canʼt get any
output.
This problem will normally be
accompanied by an error code. See
“Status Light” section of this document for additional information.
Input voltage is too low or too high.
1.
2. Thermal Error.
3. Secondary current limit has been
exceeded. (see error 54)
3a. Input control board fault (see
input control board error status).
1. Make certain that input voltage is
correct, according to the Rating
Plate located on the rear of the
machine.
2. See “Thermal LED is ON” sec-
tion.
3. Possible short in output circuit. If
condition persists, contact an
authorized Lincoln Electric Field
Service facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER WAVE® C300 CE
Page 63
E-6
PROBLEMS
(SYMPTOMS)
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E-6
Thermal LED is ON
Thermal LED is ON
“Real Time Clock” no longer functioning
General degradation of weld performance
Improper fan operation
Basic Machine Problems (Continued)
1. Improper fan operation.
2. Open thermostat circuit.
1. Control PC Board Battery.
Weld and Arc Quality Problems
1. Wire feed problem.
2. Cabling problems.
1. Check for proper fan operation.
Fan should run in a low speed
setting when the machine is idle
and in a high speed when the
output is triggered. Check for
material blocking intake or
exhaust louvers, or for excessive
dirt clogging cooling channels in
machine.
2. Check for broken wires, open
connections or faulty thermostats
in the thermostat circuit.
1. Replace the battery (Type:
BS2032)
1. Check for feeding problems. Make
sure proper gear ratio has been
selected.
2. Check for bad connections,
excessive loops in cable, etc.
3. Loss of, or improper Shielding
Gas.
4. Verify weld mode is correct for
process.
5. Machine calibration.
6. Wire feed problem.
NOTE: The presence of heat in the
external welding circuit indicates
poor connections or undersized
cables.
3. Verify gas flow and type are correct.
4.Select the correct weld mode for
the application.
5. The power source may require
calibration. (current, voltage,
WFS).
6. Check for feeding problems. Make
sure proper gear ratio has been
selected.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER WAVE® C300 CE
Page 64
E-7
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
Weld and Arc Quality Problems (Continued)
Wire burns back to tip at the end of
the weld.
TROUBLESHOOTING
POSSIBLE
CAUSE
1. Burnback Time
E-7
RECOMMENDED
COURSE OF ACTION
1. Reduce burnback time and/or
work point.
Machine output shuts down during a
weld.
Machine wonʼt produce full output.
Excessively long and erratic arc.
1. Secondary current limit has been
exceeded, and the machine shuts
down to protect itself.
2. System Fault
1. Input voltage may be too low, limiting output capability of the power
source.
2. Machine calibration.
1. Wire feed problem.
2. Loss of, or improper Shielding
Gas
1. Adjust procedure or reduce load
to lower current draw from the
machine.
2. A non-recoverable fault will interrupt welding. This condition will
also result in a status light blinking. See the Status Light section
for more information.
1. Make certain that the input voltage
is proper, according to the Rating
Plate located on the rear of the
machine.
2. Calibrate secondary current and
voltage.
1. Check for feeding problems. Make
sure proper gear ratio has been
selected.
2. Verify gas flow and type are correct
3. Machine calibration.
3. Calibrate secondary current and
voltage.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER WAVE® C300 CE
Page 65
E-8
PROBLEMS
(SYMPTOMS)
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
CAUSE
Ethernet
RECOMMENDED
COURSE OF ACTION
E-8
Cannot Connect
1. Physical connection.
2. IP address information.
3. Ethernet Speed
1. Verify that the correct patch cable
or cross over cable is being used
(refer to local IT department for
assistance).
1a. Verify the cables are fully insert-
ed into the bulk head connector.
1b. Th e LED under the PC board
ethernet connector will be lit
when the machine is connected
to another network device.
2. Use the appropriate PC utility to
verify the correct IP address information has been entered.
2a. Verify no duplicate the IP
addresses exist on the network.
3. Verify that the network device
connected to the Power Wave is
either a 10-baseT device or a
10/100-baseT device.
Connection Drops while welding
1. Cable Location
1. Verify Network cable is not located next to current carrying conductors. This would include input
power cables and welding output
cables.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER WAVE® C300 CE
Page 66
F-1
Enhanced Diagram
WIRING DIAGRAM
F-1
POWER WAVE® C300 CE
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the
machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
Page 67
F-2
DIMENSION PRINT
F-2
POWER WAVE® C300 CE
Page 68
NOTES
POWER WAVE® C300
Page 69
NOTES
POWER WAVE® C300
Page 70
WARNING
Spanish
AVISO DE
PRECAUCION
G Do not touch electrically live parts or
electrode with skin or wet clothing.
G Insulate yourself from work and
ground.
G No toque las partes o los electrodos
bajo carga con la piel o ropa mojada.
G Aislese del trabajo y de la tierra.
G Keep flammable materials away.
G Mantenga el material combustible
fuera del área de trabajo.
G Wear eye, ear and body protection.
G Protéjase los ojos, los oídos y el
cuerpo.
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
Japanese
Chinese
Korean
Arabic
G Ne laissez ni la peau ni des vête-
ments mouillés entrer en contact
avec des pièces sous tension.
G Isolez-vous du travail et de la terre.
G Berühren Sie keine stromführenden
Teile oder Elektroden mit Ihrem
Körper oder feuchter Kleidung!
G Isolieren Sie sich von den
Elektroden und dem Erdboden!
G Não toque partes elétricas e elec-
trodos com a pele ou roupa molhada.
G Isole-se da peça e terra.
G Gardez à l’écart de tout matériel
inflammable.
G Entfernen Sie brennbarres Material!
G Mantenha inflamáveis bem guarda-
dos.
G Protégez vos yeux, vos oreilles et
votre corps.
G Tragen Sie Augen-, Ohren- und Kör-
perschutz!
G Use proteção para a vista, ouvido e
corpo.
READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE
USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS
CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.
LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A
ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.
LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HERSTELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.
Page 71
G Keep your head out of fumes.
G Use ventilation or exhaust to
remove fumes from breathing zone.
G Turn power off before servicing.
G Do not operate with panel open or
guards off.
WARNING
G Los humos fuera de la zona de res-
piración.
G Mantenga la cabeza fuera de los
humos. Utilice ventilación o
aspiración para gases.
G Gardez la tête à l’écart des fumées.
G Utilisez un ventilateur ou un aspira-
teur pour ôter les fumées des zones
de travail.