Lincoln Impinger Conveyorized Oven 3270 User Manual

Global
Lincoln
3255/3270 Impinger® Conveyorized Oven
Models:
3255/3270 Impinger
3255 Natural Gas 3270 Natural Gas
3255 LP 3270 LP
Standard Features:
FastBake™ Technology
Quest EMS™ Energy Man agement
System
55” or 70” Baking Chamber
Stainless Steel Construction
Front-facing Digital Control Panel
Removable Large Front Panel for
Easy Aceess
Sandwich Door Standard
Stackable Up to Three (3) High
Available in Natural of LP Gas
Benefits:
New FastBake™ Technology
designed to bake up to 35% faster than other convey or ovens wi thout increased noise levels or loss of product quality!
Faster bake ti mes imp rove time o f
service.
Advanced A ir I mpingement
Technology enhances bake quality and uniformity.
Improved product flow during
cooking reduces operation costs.
Research and Applications suppo rt
for continued operational success.
Enodis Star serv ice sup por t is
committed to ongoing customer satisfaction.
The new Quest EMS™ unique
electronic control sy stem optimizes the gas/air mixture, low ering g as usage without compromising heat. Optimizing gas/air ratios not only improves e nergy efficiency but lowers emissions as well.
®
Conveyorized Oven
Lincoln Impinger® Conveyor Ovens are the premier continuous cook platforms for th e food service industry. Using the latest advanceme nts in air impingeme nt technology, Impinger® Ovens al low for rapid heating, cooking, baking, and crisping of foods, typically done two to four times fa ster than conventional ovens.
Easy to Operate:
Digital controls with si ngle on /off
power switch.
Microprocessor controlled bake time/
conveyor speed.
Improved view vacuum florescent
readout di splays s et tempe ratures in degrees (F° or C°), c onve yor belt speed, thermostat indicator light, and diagnostic messages for easy troubl e shooting.
All settings are automatically locked
out to eliminate accidental changes.
1111 North Hadley Road P.O. Box 1229 Fort Wayne, Indiana 46801-1229
Easy to Clean:
Front door for easy cleaning and
removal of finger assemblies.
Conveyor is re movable through the
right side opening.
Optional Features:
Flexible gas connector.
Cleaning kit (#1050)
Tel 1.888.417.5462 Fax 1.800.285.9511 E mail info@lincolnfp.com web www.lincolnfp.com
PENDING
www.lincolnfp.com
Global
Lincoln
Ventilation Requirements:
Ventilation is required. Local codes prevail. These are the “authority having jurisdiction” as stated by the National Fire Protection Association, Inc. in NFPA 96-1994. Consult the Impinger® 3255/3270 Installation and Operations Manual for ventilation recommendations.
Warranty:
All 3200 series Impinger® ovens installed in the United States and Canada come with a two (2) year parts and labor warranty starting from the date of start-up/check-out. All ovens installed in locations other than the US and Canada are warranted for one (1) year parts and ninety (90) days labor starting from the date of start-up/ check-out. Start-up/check-out must occur within eighteen (18) months of date of manufacture.
General Information | 3255 Natural Gas Ovens:
Burner Capacity
BTU/hr (MAX)
Single Oven 145,000 120 60 1 7 8”-14” 1”
Double Stack 290,000 120 60 1 14 8”-14” 1¼”
Triple Stack 435,000 120 60 1 21 8”-14” 1½”
Voltage Hertz Phase Amps
Gas Supply Pressure
Inches, Water
Column
Gas Pipe
Size (NPT)
General Information | 3255 Propane (LP) Gas Ovens:
Burner Capacity
BTU/hr (MAX)
Single Oven 145,000 120 60 1 7 11.5”-14” ¾”
Double Stack 290,000 120 60 1 14 11.5”-14” 1”
Triple Stack 435,000 120 60 1 21 11.5”-14” 1¼”
Voltage Hertz Phase Amps
Gas Supply Pressure
Inches, Water
Column
General Information | 3270 Natural Gas Ovens:
Burner Capacity
BTU/hr (MAX)
Single Oven 160,000 120 60 1 14 8”-14” 1”
Double Stack 320,000 120 60 1 28 8”-14” 1¼”
Triple Stack 480,000 120 60 1 42 8”-14” 1½”
Voltage Hertz Phase Amps
Gas Supply Pressure
Inches, Water
Column
General Information | 3270 Propane (LP) Gas Ovens:
Burner Capacity
BTU/hr (MAX)
Single Oven 160,000 120 60 1 14 11.5”-14” ¾”
Double Stack 320,000 120 60 1 28 11.5”-14” 1”
Triple Stack 480,000 120 60 1 42 11.5”-14” 1¼”
Voltage Hertz Phase Amps
Gas Supply Pressure
Inches, Water
Column
Gas Pipe
Size (NPT)
Gas Pipe
Size (NPT)
Gas Pipe
Size (NPT)
Lincoln
2.9”
(74mm)
57.4”
(1458mm)
2.7”
(69mm)
1.6”
(41mm)
5.5”
(140mm)
6”
(152mm)
55”
(1397mm)
(1270mm)
55”
(1397mm)
50”
(1270mm)
1.7”
(43mm)
8.7”
(221mm)
11.1”
(282mm)
21.6”
(550mm)
55”
(1397mm)
50”
(1270mm)
1.7”
(43mm)
8.7”
(221mm)
11.1”
(282mm)
21.6”
(550mm)
19.8”
(478mm)
55”
(1397mm)
CONVEYOR
91.1”
(2313mm)
92.9”
(2360mm)
CONVEYOR TO CONTROL BOX
74.9”
(1902mm)
CABINET TO CONTROL BOX
57.4”
(1458mm)
2.7”
(69mm)
1.6”
(41mm)
5.5”
(140mm)
6”
(152mm)
55”
(1397mm)
Technical Drawings | 3255:
Global
3255/3270 Impinger
®
Conveyorized Oven
NOTE: Specifications subject to change without notification.
Lincoln
Technical Drawings | 3270:
106.1”
(2695mm)
CONVEYOR
2.9”
(74mm)
6”
(152mm)
5.5”
(140mm)
1.5”
(38mm)
2.8”
(71mm)
57.4”
(1458mm)
69.9”
(1775mm)
50”
(1270mm)
69.9”
(1775mm)
50”
(1270mm)
11.2”
(284mm)
1.7”
(43mm)
8.8”
(223mm)
69.9”
(1775mm)
50”
(1270mm)
11.2”
(284mm)
1.7”
(43mm)
8.8”
(223mm)
21.7”
(551mm)
CONTROL BOX
109.7”
(2786mm)
106.1”
(2695mm)
CONVEYOR
70”
(1778mm)
17.5”
(445mm)
6”
(152mm)
5.5”
(140mm)
1.5”
(38mm)
2.8”
(71mm)
57.4”
(1458mm)
69.9”
(1775mm)
19.9”
(505mm)
Global
3255/3270 Impinger
®
Conveyorized Oven
NOTE: Specifications subject to change without notification.
1111 North Hadley Road P.O. Box 1229 Fort Wayne, Indiana 46801-1229
Tel 1.888.417.5462 Fax 1.800.285.9511 E mail info@lincolnfp.com web www.lincolnfp.com
©2008 Lincoln Foodservice Products, LLC. Printed in the U.S.A. 1180-2.5K-04/08-SP