Lincoln 1922 Installation Manual

INSTALLATION & OPERATING
INSTRUCTIONS
for
DUAL TECHNOLOGY FINISHER
MODEL 1920 SERIES
TO BE SERVICED ONLY BY AUTHORIZED PERSONS
DTFopsman P/N: 2810282 REV: 1/5/07
IMPORTANT WARNING AND SAFETY INFORMATION
FOR YOUR SAFETY, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTER
ATION, SERVICE OR MAINTENANCE
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS THOUROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
Minimum clearances must be maintained from all walls and combustible materials.
Keep the Finisher area free and clear of combustible material.
Adequate clearance for air openings to the control chamber is required.
Do not obstruct the ventilation holes in the control box and front of the Finisher as these provide
cooling air for the controls.
The Finisher is to be operated only on the type of electricity as shown on the specification plate.
This manual should be retained for future reference.
The electrical wiring diagram is located under the control box cover.
WARRANTY
Lincoln warrants to the original purchaser for use of each Dual Technology Finisher as follows: any part which proves to be defective in materials or workmanship within the warranty period will, subject to the terms of this warranty, be repaired or replaced at Lincoln’s option. Repair or replacement is to be done by the assigned Lincoln Authorized Service Agency. Any claims under this warranty must be presented in writing to Lincoln through the assigned Authorized Service Agency, promptly and within the warranty period.
Defective parts of the original equipment are warranted for one year from the date of purchase and the cost of repair or replacement labor shall be at the expense of Lincoln for one year from the date of purchase. (Purchase date must be within 24 months of the manufacturing date for the warranty to be in effect.) If the date of purchase cannot be verified, then warranty shall not exceed 18 months from the date of manufacture.
This warranty shall not apply if the Finisher or any part is subjected to accident, casualty, alteration, misuse, abuse, faulty installation, or if the date of manufacture is altered or removed.
The obligation of Lincoln is limited to the above and except as expressly stated herein, Lincoln makes no guarantee or warranty, express or implied, including without limitation warranties of fitness of merchant ability with respect to the Dual Technology Finisher and Lincoln has no other liability with respect thereto including without limitation, liability for incidental, special, or consequential damages.
The following items are not covered by warranty: Any item that is defective because of utility services (power surges, high and low voltage or improper connections); conveyor belt; replacement of fuses; adjustments and calibrations for temperatures speed and airflows.
DTF – 1920 Series Ops Manual - Domestic
2
PURCHASERS RESPONSIBILITY
It is the responsibility of the purchaser:
1. To see that the electric services for the Finisher are installed on site in accordance with the manufacturers specification.
2. To unload, uncrate, and install the Finisher in its proper location in accordance with this installation operation manual.
3. To see that the electric services are connected properly by a qualified installer of your choice. All such connections must be in accordance with applicable code requirements. Refer to page 5 for specific code references.
TABLE OF CONTENTS
Safety Information…………………………………………………………………………………………. 2 Warranty……………………………………………………………………………………………………. 2 Purchasers Responsibility……………………………………………………………………………..…. 3 Utility Specification………………………………………………………………………………………… 4 Exterior Dimensions………………………………………………………………………………………. 4 Components……………………………………………………………………………………………….. 5 Electrical Grounding Instructions………………………………………………………………………… 5 Spacing…………………………………………………………………………………………………….. 5 Ventilation………………………………………………………………………………………………….. 5 General Information……………………………………………………………………………………….. 5 Uncrating…………………………………………………………………………………………………… 5 Disassembly & Assembly Instructions………………………………………………………………….. 6 Start-Up / Shut Down…………………………………………………………………………………….. 7 Cleaning Instructions……………………………………………………………………………………… 7 Operator Maintenance……………………………………………………………………………………. 8 Preventive Maintenance………………………………………………………………………………….. 8 Information Of Use………………………………………………………………………………………… 8 How To Obtain Service…………………………………………………………………………………… 8 Finger Assembly…………………………………………………………………………………………… 9 Conveyor Removal………………………………………………………………………………………… 10 Conveyor Reassembly……………………………………………………………………………………. 11 Concepts…………………………………………………………………………………………………… 12
UTILITY SPECIFICATION
Model Input Rate Voltage Current Phase Hz No. of Wires Agency Listing
1921 9 Kw 208 VAC 25 Amps 3 60 3 Wires + G UL, CUL, UL Class. 1922 9 Kw 240 VAC 21.7 Amps 3 60 3 Wires + G UL, CUL, UL Class.
NOTE: Do not install these unit(s) in any area with an ambient temperature in excess of 95°F /
35°C. Doing so will cause damage to the unit(s).
DTF – 1920 Series Ops Manual - Domestic
3
EXTERIOR DIMENSIONS – DUAL TECHNOLOGY FINISHER
9 25/32"
Conveyor Opening
2 5/8" High
23 9/16"
53 1/32"
23 9/32 "
COMPONENTS
U
ANGLE PLUG – 30 AMP, 250 VAC, 3 PHASE, NEMA 15-30P
4” LEG
14 5/32"
7 1/4"
15 27/32"19 29/32"
6 3/16"
DTF – 1920 Series Ops Manual - Domestic
4