Lincoln 1117-000-A, 1131-000-A, 1130-000-A, 1133-000-A, 1132-000-A, 116-000-A User Manual
SERVICE MANUAL
(DOMESTIC)
IMPINGER ADVANTAGE DIGITAL SERIES
MODEL 1116-000-A, 1117-000-A,
1130-000-A, 1131-000-A, 1132-000-A, 1133-000-A
WITH PUSH BUTTON CONTROLS
Lincoln Foodservice Products, LLC
1111 North Hadley Road
Fort Wayne, Indiana 46804
United States of America
Phone : (800) 374-3004
U.S. Fax: (888) 790-8193 • Int’l Fax: (260) 436-0735
Technical Service Hot Line
(800) 678-9511
www.lincolnfp.com
1100AdvDigSvc REV: 3/20/08
SEQUENCE OF OPERATION
IMPINGER II ADVANTAGE
SERIAL NUMBER 2038616 AND ABOVE
(OVENS WITH PUSH BUTTON CONTROLS)
MODEL 1116-000-A NAT. GAS 120VAC 60 HZ. 1 PHASE
MODEL 1117-000-A LP GAS 120VAC 60 HZ. 1 PHASE
POWER SUPPLY Electrical power is supplied to the oven by a three-conductor cordset. Voltage
from the black conductor to the white conductor is 120VAC.
Black conductor is hot
White conductor is neutral.
Green conductor is ground.
CONTROL BOX AUTO
COOL DOWN
MAIN FAN CIRCUIT Power is permanently supplied, through a 10 amp fuse, and through a normally
BURNER CIRCUIT Closing the main power switch supplies 120VAC to the burner blowe r motor.
IGNITION CONTROL The ignition control operates on both 24VAC and 120VAC. When the control is
TEMPERATURE CONTROL Closing the main power switch supplies 120VAC to the primary of the oven
CONVEYOR DRIVE Closing the main power switch supplies 120VAC to the conveyor motor and to
When the temperature in the control box reaches 120°F ± 3° (48.9°C ± 1.7°),
the cooling fan thermostat will switch power to the control box cooling fan. The
thermostat will interrupt power to the cooling fan when the control box
temperature falls to 100°F ± 3° (37.8°C ± 1.7°).
closed control box hi-limit thermostat, to the normally open main power switch.
Power is also supplied to the normally open cooling fan thermostat. Closing the
main power switch supplies 120VAC to the main fan motor, the cooling fan
motor, the primary of the control transformer, the conveyor motor and to the
ignition control.
120VAC is also supplied, through the normally closed oven cavity hi-limit
thermostat, the main fan centrifugal switch (this switch closes when the main
fan reaches approx. 1600 RPM), to the primary of the burner transformer.
energized by 24VAC from the transformer, 120VAC is switched by the ignition
control to the hot surface igniter for 45 seconds for the hot surface igniter warm
up. The igniter glows red, 24VAC is switched to the gas valve, which opens,
and ignition should now occur.
control transformer. Secondary voltage, 24VAC, is supplied to the oven control.
The oven control is set to desired temperature. The thermocouple will provide
varying millivolts to the oven control. The oven control supplies 120VAC to the
temperature regulation valve at intermittent intervals to maintain the desired
temperature. The display on the oven control will indicate when the temperature
regulation valve is energized.
NOTE: The display also indicates oven temperature
the primary of the control transformer. Secondary voltage, 24VAC, is supplied to
the oven control. Setting the oven control to the desired time outputs voltage,
through a reversing switch, to the conveyor motor.
NOTE: The conveyor system uses a hall effect sensor and magnet to prove
operation of the conveyor motor. If the conveyor motor is not running, “BELT
JAM” is indicated on the display.
2
Impinger II – Advantage Digital Service Manual - Domestic
SEQUENCE OF OPERATION
IMPINGER II ADVANTAGE
SERIAL NUMBER 2038616 AND ABOVE
(OVENS WITH PUSH BUTTON CONTROLS)
1130-000-A 208VAC 60 HZ. 1 PHASE
1131-000-A 240VAC 60 HZ. 1 PHASE
1132-000-A 208VAC 60 HZ. 3 PHASE
1133-000-A 240VAC 60 HZ. 3 PHASE
POWER SUPPLY Electrical power to be supplied to the oven by a three conductor service for single
phase and a four conductor service for three phase.
Black conductor is hot.
Red conductor is hot.
Orange conductor is hot (used for three phase only).
Green conductor is ground.
CONTROL BOX AUTO
COOL DOWN
MAIN FAN CIRCUIT Power is permanently supplied through the 10 amp fuses, through the normally
TEMPERATURE CONTROL Closing the main power switch supplies 208/240VAC to the primary of the control
CONVEYOR DRIVE Closing the main power switch supplies 208/240VAC to the conveyor motor and
When the temperature in the control box reaches 120°F ± 3° (48.9°C ± 1.7°), the
cooling fan thermostat will switch power to the control box cooling fan. The
thermostat will interrupt power to the cooling fan when the control box
temperature falls to 100°F ± 3° (37.8°C ± 1.7°).
closed control box hi-limit thermostat, to the normally open main power switch.
Power is also supplied to the normally open cooling fan thermostat. Closing the
main power switch supplies 208/240VAC to the main fan motor, the cooling fan
motor, the primary of the control transformer, the conveyor motor and to the oven
control.
transformer. Secondary voltage, 24VAC, is supplied to the oven control. The oven
control is set to desired temperature. The thermocouple will provide varying
millivolts to the oven control. The oven control supplies 208/240VAC to the coil of
the heater relay at intermittent intervals to maintain the desired temperature. The
display on the oven control will indicate when the heater relay is energized.
NOTE: The display also indicates oven temperature.
to the primary of the control transformer. Secondary voltage, 24VAC, is supplied
to the oven control. Setting the oven control to the desired time outputs voltage,
through a reversing switch, to the conveyor motor.
NOTE: The conveyor system uses a hall effect sensor and magnet to prove
operation of the conveyor motor. If the conveyor motor is not running, “BELT
JAM” is indicated on the display.
Impinger II – Advantage Digital Service Manual - Domestic
3
SCHEMATIC DIAGRAM
MODEL 1116-000-A, 1117-000-A
SERIAL NUMBER 2038616 AND ABOVE
4
Impinger II – Advantage Digital Service Manual - Domestic
SCHEMATIC DIAGRAM
MODEL 1130-000-A, 1131-000-A
SERIAL NUMBER 2038616 AND ABOVE
Impinger II – Advantage Digital Service Manual - Domestic
5
SCHEMATIC DIAGRAM
MODEL 1132-000-A, 1133-000-A
SERIAL NUMBER 2038616 AND ABOVE
6
Impinger II – Advantage Digital Service Manual - Domestic
TROUBLESHOOTING GUIDE
GAS OVENS
SERIAL NUMBER 2038616 AND ABOVE
(OVENS WITH PUSH BUTTON CONTROLS)
MODEL 1116-000-A NAT. GAS 120VAC 60 HZ.
MODEL 1117-000-A LP GAS 120VAC 60 HZ.
SYMPTOM POSSIBLE CAUSE EVALUATION
Oven fan will not run Incoming power supply Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
Fuse, 10 Amp Check, replace if necessary.
Fuse holder Check, replace if necessary.
Hi-limit thermostat,
control box
Switch, main power Check co ntinuity between switch terminals.
Main fan motor Check for 120VAC at motor. If no voltage is
Capacitor Check for shorts or grounds.
No control box cooling Incoming power Chec k circuit breakers, reset if required. Check
Switch, main power Check co ntinuity between switch terminals.
Cooling fan Check for 120VAC at cooling fan. If no voltage is
No automatic control box
cooling
Cooling fan thermostat Check the cooling fan thermostat. (Thermostat
Cooling fan Check for 120VAC at cooling fan. If no voltage is
Oven will not heat Gas supply Check for adequate gas supply to oven.
Manual gas shut off valve. Check to see that the manual gas shut off valve is
Incoming power supply Check circuit breakers, reset if required. Check
Check for voltage on both sides of switch.
Terminals are normally closed. If open, reset and
test oven for proper operation. If thermostat will
not hold, and control box temperature is not
exceeding 140°F (60°C), replace thermostat.
Replace switch as needed.
present, trace wiring back to main power switch.
WITH POWER OFF: Check for opens, shorts or
grounds. Turn fan blade to check for locked rotor.
WARNING: Capacitor has a stored charge,
discharge before testing.
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
Replace switch as needed.
present, trace wiring back to power switch. If
voltage is present, and motor does not run, check
for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
closes at 120°F and opens at 100°F). With the
cooling fan thermostat pre-heated, check for
continuity. If switch is open, replace cooling fan
thermostat.
present, trace wiring back to cooling fan
thermostat. If voltage is present, and motor does
not run, check for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
open. Also check flexible gas line connection for
any damage.
Impinger II – Advantage Digital Service Manual - Domestic
7
Main fan If not operating, refer to “Oven fan will not run”.
Centrifugal switch of main fan
motor
Check for 120VAC at wire #5 (input to centrifugal
switch, located at 6-pin connector in raceway near
the main fan motor) to neutral. If no voltage is
present, trace wiring back to the main power
switch. If voltage is present, check for 120VAC at
wire #22 (output of centrifugal switch) to neutral. If
no voltage is present at #22, and the motor is
running, replace the main fan motor.
Hi-limit thermostat,
oven cavity
Terminals are normally closed. If open, reset
thermostat and retest. If thermostat will not hold
for maximum oven temperature, and oven is not
exceeding temperature setting, check for proper
location of capillary bulb in its spring holder. If the
capillary checks okay, replace the hi-limit
thermostat.
Burner blower motor Check for 120VAC supplied to burner blower
motor at wire #13 to neutral. If no voltage is
present, trace wiring back to the main power
switch. If voltage is present, and the motor is not
running, check for opens, shorts or grounds.
WITH POWER OFF: Turn motor to check for
locked rotor.
Burner transformer Check for 120VAC supplied to the primary of the
burner transformer. If no voltage is present, trace
wiring back to the oven cavity hi-limit thermostat.
If voltage is present, check for 24VAC at
transformer secondary. If there is primary voltage
but no secondary voltage, replace burner
transformer.
Centrifugal switch of burner
blower motor
Check for 24VAC at motor connector, wire #13 to
neutral. If voltage is not present, trace wiring back
to transformer. If voltage is present, check for
voltage at wire #14 to neutral. If no voltage is
present at wire #14, and motor is running, replace
burner blower motor.
Ignition control Check for 24VAC at ignition control terminals
marked “24V”, if no voltage is present, trace wiring
back to centrifugal switch. Check for 120VAC to
ignition control at terminal “L1” to neutral. If no
voltage is present, trace wiring back to main
power switch. When 24VAC is supplied to the
ignition control, the ignition control switches
120VAC to the hot surface igniter If 24VAC and
120VAC are supplied to ignition control, but there
is no voltage at the hot surface igniter, replace the
ignition control.
Hot surface igniter If 120VAC is present at hot surface igniter
terminals, visually check to see that the igniter is
heating (igniter may be viewed through the port in
the end of burner tube). The igniter should glow
bright red. If the igniter does not heat, replace the
hot surface igniter.
Ignition control After 45 seconds of hot surface igniter pre-heat,
the ignition control will switch 23VAC to the gas
control valves. Check for 24VAC output from
ignition control across terminals marked “valve”
and “valve gnd”. If no voltage is present, replace
ignition control.
Gas control valves When 24VAC is supplied to the gas control
8
Impinger II – Advantage Digital Service Manual - Domestic
valves, the valve should open. Check for gas
pressure at the manifold tap located just before
the burner. If there is no pressure, check the
incoming gas supply to be sure all manual valves
are open and flexible gas hose is properly
connected. If gas is present, and the gas control
valve is energized, but there is no gas pressure at
the burner manifold, replace the gas control
valves.
Flame will not stay lit Hot surface igniter Six seconds after the gas valve opens, ignition
must occur. If flame is not detected, the ignition
control will shut off and lock out. To reset the
ignition control, turn off the power switch for 45
seconds, then turn the switch on to re-try ignition.
The ignition control requires a minimum of 0.8 DC
microamps to prove flame. To check flame
sensing operation, connect a digital multimeter
(capable of measuring DC microamps) between
the “ground” terminal on ignition control and the
ground lead.
NOTE: This is a current measurement and the
meter must be connected in series
If these readings are not achieved, replace hot
surface igniter.
NOTE: The DC microamp test must be conducted
with the oven in low flame (bypass) operation. Set
the temperature control to the lowest setting.
Power supply If there is sufficient microamp current, but the
flame will not stay lit, check for proper polarity of
the 120VAC power supply.
Ignition control If there is sufficient microamp current, and the
120VAC polarity is correct, but the flame will not
stay lit, replace the ignition control.
NOTE: Check for proper ground connection on
ignition control.
NOTE: Flame should be on at
this time
Low flame is on,
but no main flame
Control transformer Check for 120VAC supply to the primary of the
control transformer. If no voltage is present, trace
wiring back to the main power switch. If voltage is
present, check for 24VAC at the transformer
secondary. If there is primary voltage, but no
secondary voltage, replace the control
transformer.
Oven control Check for 24VAC supply to control. If no voltage is
present, trace wiring back to control transformer. If
24VAC is present, check for a read-out on the
display. If there is 24VAC supplied, but there is no
read-out on the control display, replace the oven
control.
If there is a read-out on the control, set the control
to maximum temperature (see installation
operations manual for temperature adjustment).
With the control set at maximum temperature,
check for 120VAC at the temperature regulation
valve. If there is voltage at the temperature
regulation valve, proceed to “Temperature
regulation valve” for next check. If there is no
voltage at the temperature regulation valve, trace
wiring back to the oven control. If there is no
Impinger II – Advantage Digital Service Manual - Domestic
9
voltage output at the oven control, check the read-
out on the control. If the control reads “PROBE
FAIL”, this indicates that the thermocouple has
failed or become disconnected from the oven
control.
Thermocouple Check to be sure that the thermocouple is
securely connected to the oven control. If the
thermocouple is connected to the oven control,
and the control indicates “PROBE FAIL”,
disconnect the thermocouple from the oven
control and measure the resistance of the
thermocouple. The thermocouple should read
approx. 11Ω. If these readings are not achieved,
replace the thermocouple. If these readings are
correct, proceed.
Oven control If the thermocouple checks good, but the oven
control display indicates that there is a
thermocouple failure, replace the oven control. If
the oven control indicates a temperature reading
but the oven will not heat, proceed.
Thermocouple WITH POWER ON AND THERMOCOUPLE
ATTACHED TO THE OVEN CONTROL: Measure
the DC millivolt output of the thermocouple. Refer
to the thermocouple chart (located in the
“Removal” section of the manual) for proper
millivolt readings. If these readings are not
achieved, replace thermocouple.
Oven control If the thermocouple checks good, but there is no
120VAC output to the temperature regulation
valve, replace the oven control. If there is 120VAC
output to the temperature regulation valve,
proceed.
Temperature regulation valve Check for 120VAC supplied to temperature
regulation valve. If voltage is present, listen for
valve to open and close. Also check for opens or
shorts in the operating coil. Replace temperature
regulation valve as needed.
Intermittent heating Thermal/overload of main fan
and burner blower motors
The main fan motor and burner blower motor are
equipped with internal thermal protection and will
cease to operate if overheating occurs. As the
motors overheat and then cool, this will cause the
heating system to cycle on and off intermittently.
Improper ventilation or lack of preventive
maintenance may cause this problem. Also, most
of the problems listed under “Oven will not heat”
can cause intermittent failure.
Conveyor will not run Power supply Check for incoming voltage at line 1 to neutral.
There should be a reading of 120VAC. If not
present, check circuit breakers.
Fuse, 10 Amp Check, replace if necessary.
Fuse holder Check, replace if necessary.
Hi-limit thermostat, control box Check for voltage on both sides of switch.
Terminals are normally closed. If open, reset and
test oven for proper operation. If thermostat will
not hold, and control box temperature is not
exceeding 140°F (60°C), replace thermostat.
Power switch Check continuity between switch terminals.
Replace switch as needed.
Control transformer Check for 120 VAC supply to the primary of the
control transformer. If no voltage is present, trace
10
Impinger II – Advantage Digital Service Manual - Domestic
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.