Lincat LCG, LPG, LRG, LCG/S, LPG/S Installation, Operating and Servicing Instructions

...
Please make a note of your product details for future use:
Date Purchased:_________________________ Model Number:__________________________ Serial Number:__________________________ Dealer:_________________________________ _______________________________________
Installation, Operating and Servicing Instructions
Lynx 400 Electric Contact Grills LCG, LPG, LRG, LCG/S, LPG/S, LRG/S, LCG2, LPG2, LRG2
IS 315 ECN 3607 Page 1 of 7
CONTENTS
Important Information
2
Warnings and Precautions
3
Technical Data
3
Checklist of Enclosures
3
Installation and Commissioning
3-5
Operating Instructions
5
Cleaning
6
Servicing, Maintenance and Component Replacement
6
Fault Finding
6
Spare Parts List
6
Service Information and Guarantee
7
IMPORTANT INFORMATION
Read these instructions carefully before using this product, paying particular attention to all sections that carry warning symbols, caution symbols and notices. Ensure that these are understood at all times.
WARNING!
This symbol is used whenever there is a risk of personal injury.
CAUTION!
This symbol is used whenever there is a risk of damaging your Lincat product.
NOTE:
This symbol is used to provide additional information, hints and tips.
KEEP THIS MANUAL FOR FUTURE REFERENCE
IS 315 ECN 3607 Page 2 of 7
WARNINGS AND PRECAUTIONS
TECHNICAL DATA
Model
Height
Width (mm)
Depth (mm)
Weight (kg)
LCG, LPG, LRG
165
293
400
20.0
LCG/S, LPG/S, LRG/S
293
20.0
LCG2, LPG2, LRG2
623
40.0
CHECK LIST OF ENCLOSURES
Warranty card
Instructions manual
Scraper (/S models only)
INSTALLATION AND COMMISSIONING
This appliance must be installed, commissioned and serviced by a qualified person in accordance with national and local regulations in force in the country of installation.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person.
Ensure that the plug/socket is accessible at all times. Strip plastic coating and clean the appliance before use. During operation parts may become hot - avoid accidental contact. Disconnect this appliance before servicing, maintenance or cleaning.
This appliance must be earthed.
An equipotential bonding terminal is provided to allow cross bonding with other equipment.
IS 315 ECN 3607 Page 3 of 7
If replacing the plug connect the terminals as follows: Green and Yellow wire Earth E Blue wire Neutral N Brown wire Live L
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed. Install this appliance on a level surface ensuring all vents are unobstructed. Any partitions, walls or furniture must be of non-combustible material. Minimum distances A 100mm B 1000mm – see Fig 1.
Fig 1
IS 315 ECN 3607 Page 4 of 7
Power Ratings
Model
kW
Amps
LCG, LPG, LRG, LCG/S, LPG/S, LRG/S
2.25
9.8
LCG2, LPG2, LRG2
2 x 2.25
2 x 9.8
OPERATING INSTRUCTIONS
Only qualified or trained personnel should use this appliance. Connect the appliance to an electrical supply. The green neon indicates power to
the appliance. Turn the control knob to the desired setting – the amber neon illuminates and
extinguishes when temperature is reached. The amber neon will periodically illuminate as the element cycles. /S models have a mechanical timer – this does not control the elements. This appliance is fitted with a safety thermostat, which will cut power to the
appliance under fault conditions. If the green neon illuminates but the appliance does not heat up, the safety thermostat may need re-setting. Push the red button on the back of the appliance (Fig 2 – B). This re-set cannot be activated until the appliance is cool.
Fig 2
IS 315 ECN 3607 Page 5 of 7
CLEANING
SERVICING, MAINTENANCE AND COMPONENT REPLACEMENT
Part Number
Description
Used on
CO239
Conduit assembly
All
EL225
Base element
EL226
Top element
FE35
Foot
HA78
‘D’ Handle
KN240
Thermostat knob
KN273
Timer knob
/S models
NE42
Amber neon
All
NE43
Green neon
PL202
Mains cable
SP81
Spring
TH46
Control thermostat
TH86
Safety thermostat
TI38
Timer
/S models
FAULT FINDING
SPARE PARTS LIST
Do not use a water jet or steam cleaner, and do not immerse this appliance. Clean all panels with warm water and mild detergent, do not use abrasive
materials. Dry with a soft cloth.
Periodically it may be necessary to re-tension the upper plate lifting mechanism. This is achieved by removing the rear cover and adjusting the 4 screws. (Fig 2 – A).
All other servicing, maintenance and component replacement on this appliance should be carried out by one of our recommended service engineers.
Please refer to the Service Help Desk number on the final page of this manual.
IS 315 ECN 3607 Page 6 of 7
Product code
All available on serial plate
Type number
Serial number
SERVICE INFORMATION
For help with the installation, maintenance and use of your Lincat equipment, please contact our service department:
UK: 01522 875520
For non-UK customers, please contact your local Lincat dealer
All service work, other than routine cleaning should be carried out by one of our authorised service agents. We cannot accept responsibility for work carried out by other persons.
To ensure your service enquiry is handled as efficiently as possible, please tell us: Brief details of the problem
Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance, during normal working hours, Monday to Friday, 08:30 to 17:00.
GUARANTEE
This unit carries a comprehensive UK mainland 2 year warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights.
The guarantee does not cover:
Accidental damage, misuse or use not in accordance with the manufacturer’s
instructions
Consumable items (such as filters, glass, bulbs, slot toaster elements and door
seals.)
Damage due to incorrect installation, modification, unauthorised service work or
damage due to scale, food debris build-up, etc.
The manufacturer disclaims any liability for incidental, or consequential damages.
Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work.
Service calls to equipment under warranty will be carried out in accordance with the conditions of sale. Unless otherwise specified, a maximum of 15 minutes of administrative time, not spent directly carrying out servicing work, is provided for within the warranty. Any requirement for staff attending the call to spend greater time than 15 minutes due to administrative requirements, such as on health and safety risk assessments, will be chargeable at the prevailing rate.
IS 315 ECN 3607 Page 7 of 7