Lincat EB3FX, EB4FX, EB6FX, EB6TFX, EB3FX/PB AND EB3FX/TT User guide

Installation, Operating and Servicing Instructions
Waterboiler EB3FX, EB4FX, EB6FX, EB6TFX, EB3FX/PB AND EB3FX/TT
Date Purchased:_________________________
Model Number:__________________________
Serial Number:__________________________
Dealer:_________________________________
_______________________________________
IS590 ECN 3846 Page 1 of 12
CONTENTS
Important Information 2 Warnings and Precautions 3 Technical Data 3 Checklist of Enclosures 3 Installation and Commissioning 4 Operating Instructions 5 Cleaning 8 Descaling Servicing, 8 Maintenance and Component Replacement 9 Fault Finding 9 Spare Parts List 9 Accessories 9 Service Information and Guarantee 10
IMPORTANT INFORMATION
Read these instructions carefully before using this product, paying particular attention to all sections that carry warning symbols, caution symbols and notices. Ensure that these are understood at all times
WARNING!
This symbol is used whenever there is a risk of personal injury.
CAUTION!
This symbol is used whenever there is a risk of damaging your Lincat product.
NOTE:
This symbol is used to provide additional information, hints and tips.
KEEP THIS MANUAL FOR FUTURE REFERENCE
.
IS590 ECN 3846 Page 2 of 12
WARNINGS AND PRECAUTIONS
EB3FX
EB4FX
EB6FX
EB6TFX
EB3FX/PB
EB3FX/TT
This appliance must be installed, commissioned and serviced by a qualified person in accordance with national and local regulations in force in the country of installation.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person.
Ensure that the plug/socket is accessible at all times.
Strip plastic coating and clean the appliance before use.
During operation parts may become hot - avoid accidental contact.
Disconnect this appliance before servicing, maintenance or cleaning.
TECHNICAL DATA
Height (mm) 600 600 690 690 600 600 Width (mm) 250 250 250 250 250 250 Depth (mm) 525 525 525 525 525 525 Weight (kg) 15 15 18 18 15 16 Power rating(kW) 3 4.5 6 6 3 3 Current rating (A) 13 20 26 26 13 13
CHECK LIST OF ENCLOSURES
Warranty card Instructions manual Drip tray Drip tray insert Connection hose Silicone drain hose assembly
IS590 ECN 3846 Page 3 of 12
INSTALLATION AND COMMISSIONING
This appliance must be earthed.
If replacing the plug connect the terminals as follows: Green and Yellow wire Earth E Blue wire Neutral N Brown wire Live L
Means of isolation with at least 3mm contact separation in all poles must be incorporated into the fixed wiring of EB4FX, EB6FX and EB6TFX appliances.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed.
Only install this unit in locations where it can be overseen by trained personnel.
Inlet water pressure should be between 2 and 6 bar. (0.2MPa to 0.6MPa)
Ambient air temperature shall be between 5 and 30 deg C
Electrical supply
The EB3FX series are supplied with a 13 amp plug to BS1363.
The EB4FX is supplied with a bulkhead cable connector. Connect a 2.5mm2 3 core cable.
The EB6FX and EB6TFX are supplied with a bulkhead cable connector. Connect a
2
4mm
Means of isolation with at least 3mm contact separation in all poles must be incorporated into the fixed wiring of these appliances.
Water supply and waste connection (All)
Connect the supplied white water inlet hose to the inlet connection point on the base of the boiler and the other end to the mains supply via an accessible isolating tap with a ¾” BSP thread.
Use the hose set supplied with the appliance - any previous hose set is not to be re­used.
Ensure the metal overflow pipe protrudes through the metal base of the boiler.
Potable water. If solid particles are known to be in the supply, add an extra inline filter or strainer
3 core cable.
IS590 ECN 3846 Page 4 of 12