Lincat D3H, D3H/75, D5H, C6H, D5H/75 Installation, Operating And Servicing Instructions

...
IS 282 ECN 3607 Page 1 of 8
Installation, Operating and Servicing Instructions
Seal Heated Merchandisers C6H, D3H and D5H – all models
Please make a note of your product details for future use:
Date Purchased:_________________________ Model Number:__________________________ Serial Number:__________________________ Dealer:_________________________________ _______________________________________
IS 282 ECN 3607 Page 2 of 8
CONTENTS
Important Information
2
Warnings and Precautions
3
Technical Data
3
Checklist of Enclosures
3
Installation and Commissioning
3-4
Operating Instructions
5-6
Cleaning
6-7
Servicing, Maintenance and Component Replacement
7
Fault Finding
7
Spare Parts List
7
Service Information and Guarantee
8
IMPORTANT INFORMATION
Read these instructions carefully before using this product, paying particular attention to all sections that carry warning symbols, caution symbols and notices. Ensure that these are understood at all times.
WARNING!
This symbol is used whenever there is a risk of personal injury.
CAUTION!
This symbol is used whenever there is a risk of damaging your Lincat product.
NOTE:
This symbol is used to provide additional information, hints and tips.
KEEP THIS MANUAL FOR FUTURE REFERENCE
IS 282 ECN 3607 Page 3 of 8
WARNINGS AND PRECAUTIONS
This appliance must be Installed, Commissioned and Serviced by a qualified person in accordance with national and local regulations in force in the country of installation.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person.
Ensure that the plug/socket is accessible at all times.
Strip plastic coating and clean the appliance before use. During operation parts may become hot - avoid accidental contact. Disconnect this appliance before servicing, maintenance or cleaning.
TECHNICAL DATA
D3H/75
D5H/75
D5H/100
C6H/75
C6H/100
Volume (l)
113.0
163.0
220.0
284.0
380.0
Width (mm)
750
750
1000
750
1000
Depth (mm)
350
500
500
650
650
Height (mm)
575
575
575
755
755
Weight (kg)
34.0
43.0
55.0
57.0
71.0
Power rating (kW)
0.8
1.5
2.0
1.5
2.0
CHECK LIST OF ENCLOSURES
Warranty card
Instructions manual
Shelves
Base plate(s)
Crumb tray
Water bath and lid
3mm Allen key
INSTALLATION AND COMMISSIONING
This appliance must be earthed.
IS 282 ECN 3607 Page 4 of 8
An equipotential bonding terminal is provided to allow cross bonding with other equipment.
If replacing the plug connect the terminals as follows: Green and Yellow wire Earth E Blue wire Neutral N Brown wire Live L
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed. Any
partitions, walls or furniture must be of non-combustible material. Minimum
distances A 100mm B 500mm – see Fig 1.
Fig 1
IS 282 ECN 3607 Page 5 of 8
OPERATING INSTRUCTIONS
Only qualified or trained personnel should use this appliance.
This appliance relies on the circulation of warm air passing through and around the
shelves. Ensure circulation is not obstruct by overloading product or by using
aluminium foil.
This appliance is intended for displaying pre-heated food – not for heating
food.
Fig 2
Identification (Fig 2)
1. Cable 2. On/Off switch 3. Light switch 4. Temperature controller 5. Crumb tray
/ Water bath
Ensure the base plates lie flat within the base and the shelves are secure. Close all
doors – front and rear. Connect to the electricity supply, switch on the light (3) then
switch on the ‘On/Off’ switch (2). C6 appliances are factory set to 85 Deg C. Press
and hold the ‘Set’ button to confirm this.
IS 282 ECN 3607 Page 6 of 8
D3 and D5 models have a manual temperature control (4). Turn to setting 5 and
wait 30 minutes before loading with pre-heated food. Adjust the temperature as
required.
C6 models have a digital display controller (4). Wait 30 minutes until the display
shows 85 Deg C. Load with pre-heated food. Adjustment between 75-95 Deg C is
available by pressing and holding the ‘Set’ button and using the buttons marked <<-
< and >->>.
Note: The temperature display relates to the air temperature inside the
cabinet – not the food temperature.
Humidity feature - Fig 3
Fig 3
The integral water bath B with lid A is intended to be used to keep food moist when
the appliance is lightly loaded. Fill with warm water. To prevent condensation, do
not over-load shelves with food. Check the water level – be aware the water bath
will become hot during use.
Adjusting shelf positions
Disconnect from electricity supply and allow appliance to cool. Slide the doors to
the centre and lift up and out of the bottom runners to remove. Remove the
shelves. Use the Allen key provided to adjust the shelf supports. At the rear, the
shelf supports are situated behind the cable panel. Remove the screws in the cable
panel and open the panel until adjustment of the shelf supports can be made. Do
not completely remove the cable panel. Replace the panel, ensuring cables are
not trapped.
CLEANING
Do not use a water jet or steam cleaner, and do not immerse this appliance.
IS 282 ECN 3607 Page 7 of 8
Remove the rear doors, shelves and base plates. Brush crumbs into the tray Fig 3 C. Shelves and supports may be washed in a dishwasher.
Clean all panels with warm water and mild detergent, do not use abrasive materials.
Dry with a soft cloth.
SERVICING, MAINTENANCE AND COMPONENT REPLACEMENT
Replacing a light tube
Disconnect the appliance from the supply. Allow tube to cool. Use the Allen key provided to remove the end caps from the light unit. Remove the diffuser from the clips. Rotate the tube 900 and pull down until released. Replace the starter if necessary by rotating anticlockwise and removing. Fit the new tube by reversal of the above sequence.
All other servicing, maintenance and component replacement on this appliance
should be carried out by one of our recommended service engineers.
Please refer to the Service Help Desk number on the final page of this manual.
Part Number
Description
Used on
BU171
Light tube
All
EL218
Element
D3
EL162 (75 models)
Element
D5 C6 EL161 (100 models)
Element
GL68
Starter
All
HP17 (75 models)
Base plate
C6
HP18 (100 models)
Base plate
C6
HP19 (100 models)
Base plate
D5
HP20 (75 models)
Base plate
D5
HP21
Base plate
D3
KN203
Control knob
D3 D5
SH93
Shelf
D3
SH91(75 models)
Shelf
D5
SH92 (100 models)
Shelf
D5
SH97 (75 models)
Shelf
C6
SH98 (100 models)
Shelf
C6
S/M0085
Self service door knob
D5 C6
FAULT FINDING
SPARE PARTS LIST
IS 282 ECN 3607 Page 8 of 8
For help with the installation, maintenance and use of your Lincat equipment,
please contact our service department:
UK: 01522 875520
For non-UK customers, please contact your local Lincat dealer
All service work, other than routine cleaning should be carried out by one of our
authorised service agents. We cannot accept responsibility for work carried out by
other persons.
To ensure your service enquiry is handled as efficiently as possible, please tell us:
Brief details of the problem
Product code
All available on serial plate
Type number
Serial number
Lincat reserve the right to carry out any work under warranty, given reasonable
access to the appliance, during normal working hours, Monday to Friday, 08:30 to
17:00.
GUARANTEE
This unit carries a comprehensive UK mainland 2 year warranty. The guarantee is
in addition to, and does not diminish your statutory or legal rights.
The guarantee does not cover:
Accidental damage, misuse or use not in accordance with the manufacturer’s
instructions
Consumable items (such as filters, glass, bulbs, slot toaster elements and door
seals.)
Damage due to incorrect installation, modification, unauthorised service work or
damage due to scale, food debris build-up, etc.
The manufacturer disclaims any liability for incidental, or consequential damages.
Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work.
Service calls to equipment under warranty will be carried out in accordance with the conditions of sale. Unless otherwise specified, a maximum of 15 minutes of administrative time, not spent directly carrying out servicing work, is provided for within the warranty. Any requirement for staff attending the call to spend greater time than 15 minutes due to administrative requirements, such as on health and safety risk assessments, will be chargeable at the prevailing rate.
SERVICE INFORMATION
Loading...