Linak DL12, DB12, DL17 systemwith CBD4, CBD5, CBD6 User Manual

...
Page 1
Page 1 of 36
USER MANUAL
DL12, DB12, DL14, DB14, DL17 system with CBD4, CBD5 or CBD6
To learn more about LINAK, please visit:
WWW.LINAK.COM
Page 2
Page 2 of 36
Page 3
Page 3 of 36
Contents
Preface ............................................................................................................................................... 4
Important information ....................................................................................................................... 5
Safety instructions .............................................................................................................................. 5
General .......................................................................................................................................... 5
Before installation, reinstallation or troubleshooting ........................................................................ 6
Before start-up ............................................................................................................................... 6
During operation ............................................................................................................................ 6
Misc. .............................................................................................................................................. 6
Only for EU markets........................................................................................................................ 7
Only for Non EU markets ................................................................................................................ 7
Misuse ............................................................................................................................................ 7
Repairs ............................................................................................................................................... 8
Manufacturer’s declaration ................................................................................................................ 8
Misc. on the DESKLINE
®
system ......................................................................................................... 9
Warranty ........................................................................................................................................ 9
Maintenance .................................................................................................................................. 9
Description of the DESKLINE
®
system ............................................................................................. 10
Mounting guidelines for the DL14 system ...................................................................................... 11
Mounting top .............................................................................................................................. 11
Mounting foot ............................................................................................................................. 13
Mounting guidelines for the column DL12 .................................................................................... 14
Mounting top .............................................................................................................................. 14
Mounting foot ............................................................................................................................. 14
Mounting guidelines for the column DL17 .................................................................................... 15
Mounting top .............................................................................................................................. 15
Mounting foot ............................................................................................................................. 15
Mounting guidelines for DB12 and DB14 ...................................................................................... 16
Mounting guidelines for the CBD4/CBD5/CBD6S ........................................................................... 18
Electrical connection of the DB/DL system ..................................................................................... 19
Initialisation of the DESKLINE parallel system ................................................................................ 20
Anti-Collision
TM
.................................................................................................................................. 21
PIEZO
TM
: description of the feature ................................................................................................ 22
Accessories and repair ...................................................................................................................... 23
Disposal of LINAK products .............................................................................................................. 24
Labels ............................................................................................................................................. 25
Drawing appendix ............................................................................................................................ 27
Declaration of conformity ................................................................................................................ 33
Addresses .......................................................................................................................................... 36
Page 4
Page 4 of 36
Preface
We are delighted that you have chosen a product from LINAK A/S. LINAK systems are high-tech products based on many years of experience in the manufacture and development of actuators, electric control boxes, controls, and chargers.
We are also constantly improving our products to meet customer requirements.
This User Manual will tell you how to install, use and maintain your LINAK DESKLINE
®
products.
We are sure that the DESKLINE
®
products will give you many years of problem-free operation. Before our products leave the factory they undergo full function and quality testing. Should you nevertheless experience problems with your systems, you are always welcome to contact our service departments or service centres.
LINAK subsidiaries and distributors all over the world have authorised service centres, which are always ready to help you.
LINAK provides a warranty on all its products. This warranty, however, is subject to correct use in accordance with the specifications, maintenance being done correctly and any repairs being carried out at a service centre, which is authorised to repair LINAK products.
Changes in installation and use of LINAK systems can affect their operation and durability. Changes must therefore only be made by agreement with LINAK A/S and are made at your own risk.
LINAK A/S
Page 5
Page 5 of 36
Safety instructions
General
Important information
Important information on LINAK
®
products can be found under the
following headings:
Warning!
Failure to comply with these instructions may result in accidents involving serious personal injury.
Failing to follow these instructions can result in the product being damaged or being destroyed.
Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed.
Failure to comply with instructions marked with the ”NOTE” symbol may result in serious damage to the system or one of its components.
It is important for everyone who is to connect, install or use the systems to have the necessary information and access to this User Manual. Follow the instructions for mounting – risk of injury if these instructions are not followed.
The appliance is not intended for use by young children or infirm persons without supervision.
If there is visible damage on the product, it must not be installed.
Note that during construction of applications, in which the actuator is to be fitted, there must be no possibility of personal injury, for example squeezing of fingers or arms.
Assure free space for movement of applications in both directions to avoid blockade.
Page 6
Page 6 of 36
Before installation, reinstallation, or troubleshooting
• Stop the DB/DL.
• Switch off the power supply and pull out the mains plug.
• Relieve the DB/DL of any loads, which may be released during the work.
Before start-up:
• Make sure that the system has been installed as instructed in this User Manual.
• Make sure that the voltage at the control box is correct before the system is connected to the mains.
• System connection. The individual parts must be connected before the control box is connected to the mains. See the User Manual for LINAK actuators, if necessary.
During operation:
• If the control box makes unusual noises or smells, switch off the mains voltage immediately.
• Take care that the cables are not damaged.
• Unplug the mains cable on mobile equipment before it is moved.
Misc.
The actuator system has a sound level below 55dB(A) in typical applications.
Updated manuals and declarations can always be found here:
www.linak.com/deskline
Page 7
Page 7 of 36
Only for EU markets
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Only for Non EU markets
Persons who do not have the necessary experience or knowledge of the product/products must not use the product/products. Besides, persons with reduced physical, sensory or mental abilities must not use the product/products, unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons.
Moreover, children must be under surveillance to ensure that they do not play with the product.
It is the operator’s responsibility to ensure that there is free space for the application to move without risk for the operator or bystanders before operating the application.
Misuse
Do not overload the actuators – this can cause danger of personal injury and damage to the system.
Do not use the actuator system for lifting persons. Do not sit or stand on a table while operating – risk of personal injury.
Do not use the system in environments other than the intended indoor use
Page 8
Page 8 of 36
Repairs
In order to avoid the risk of malfunction, all DESKLINE® repairs must only be carried out by authorised LINAK workshops or repairers, as special tools must be used and special gaskets must be fitted. Lifting units under warranty must also be returned to authorised LINAK workshops.
Warning!
If any of the DESKLINE
®
products are opened, there will be a risk of subsequent malfunction.
Warning!
The DESKLINE
®
systems do not withstand cutting oil.
Page 9
Page 9 of 36
Misc. on the DESKLINE® system
Warranty
There is a 36 months’ warranty on DESKLINE products against manufacturing faults from the production date of the individual products (see label). LINAK A/S warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with. Furthermore, the system must not be exposed to violent treatment. In the event of this, the warranty will be ineffective/invalid. For further details, please see standard terms of sale and delivery for LINAK A/S.
Maintenance
Clean dust and dirt on the outside of the system at appropriate intervals and inspect them for damage and breaks. Inspect the connections, cables and plugs and check for correct functioning as well as fixing points.
Service of double insulated products:
Class II
A Class II or double insulated electrical appliance is one which has been designed in such a way that it does not require a safety connection to electrical earth (US: ground). The basic requirement is that no single failure can result in dangerous voltage becoming exposed so that it might cause an electric shock and that this is achieved without relying on an earthed metal casing. This is usually achieved at least in part by having two layers of insulating material surrounding live parts or by using reinforced insulation. There is no earthing/grounding means provided on the product, and no earthing/grounding means is to be added to the product. In Europe, a double insulated appliance must be labelled “Class II”, “double insulated” or bear the double insulation symbol (a square inside another square). Servicing a double-insulated product requires extreme care and knowledge of the system, and is to be done only by qualified service personnel. Replacement parts for a double insulated product must be identical to the parts they replace.
The cleaners and disinfectants must not be highly alkaline or acidic (pH value 6-8).
Page 10
Page 10 of 36
Description of the DESKLINE® system
Each DESKLINE® actuator/column is equipped with a motor and parallel/memory drive is ensured by means of software in the CBD4/CBD5/CBD6 that also takes account of an oblique load on the desk. Soft start and stop are also part of this software, which ensures a soft start and stop when adjusting the desk.
Application of the DESKLINE
®
system:
Irrespective of the load, the duty cycle 10% ~ 6 min./ hour or max. 2 min. at continuous use stated in the data sheets, must NOT be exceeded as this will result in a superheating of the motor and the control box. Exceeding the duty cycle will result in a dramatic reduction of the life of the system.
The DB/DL system range contains following products:
• 1 control box CBD4/CBD5/CBD6
• DL12, DB12, DL14, DB14 or DL17 (1 - 4)
• 1 exchangeable mains cable
• motor cables (1 - 4)
• 1 DP1U/DPF1M (if memory function is required) DP1C//DPT/DPF1C (if memory function and display are required) or 1 DPA/DPB/DP1K/DP1V/DPFK (if only up/down is required).
Page 11
Page 11 of 36
Mounting guidelines for the DL14 system
Mounting top
The top of the column is supplied with 4 M6 threaded holes meant for mounting onto the desk frame. We advise you to fasten the desk frame by means of 4 pcs. M6 screws of a good quality (min. 8.8) and of a suitable length, which must not go further than max. 14 mm into the column. The thrust moment must not exceed 10 Nm.
Screw length Min. B + 9 mm Max. B + 14 mm
Page 12
Page 12 of 36
As the desktop amplifies the sound, we advise you to place a vibration/shock absorbing material between the desktop and the desk frame.
Table top Absorbing material
Height of the DL in the lowest position
Min. desk height
Floor level
LINAK recommends that the DESKLINE® DL system should be used in push applications.
(Example of how to mount a 2-parallel DESKLINE
®
DL system)
Page 13
Page 13 of 36
Mounted with 2 x M8
Mounted with 4 x M6
Mounting guidelines for the column DL14
Mounting foot
The DL14 is supplied with 4 M6 threaded holes and 2 M8 screws for mounting of the foot. You can either use 2 M8 screws or 4 M6 screws dependent on your foot design. We advise you to use screws of a good quality min. 8.8 and of a suitable length, which must not go further than 16 mm into the DL14 column. The thrust moment must not exceed 10 Nm in the bottom plate thread. The holes in the foot ought to be sufficiently larger than ø6 so that it is possible to bring the foot to a level line at assembly/mounting of the table.
Page 14
Page 14 of 36
Mounting guidelines for the column DL12
Min. 12 mm
MC6
Mounting foot
The DL12 is supplied with 4 x M6 threaded holes. We advise you to use screws of a good quality min.
8.8 and of a suitable length. The length needs to be minimum 9 mm. The screw torque must not exceed 10 Nm in the bottom plate thread. The holes in the foot ought to be sufficiently larger than ø6 so that it is possible to bring the foot to a level line at assembly/mounting of the table.
Min. 9 mm
SECTION SKRUE_BUND-SKRUE_BUND
MC6
As the desktop amplifies the sound, we advise you to place a vibration/shock absorbing material between the desktop and the desk frame.
(Example of how to mount the DESKLINE
®
system)
Mounting top
The top of the column is supplied with 4 x M6 threaded holes meant for mounting onto the desk frame. We advise you to fasten the desk frame by means of 4 x M6 screws of a good quality (min. 8.8) and of a suitable length, minimum 12 mm. The screw torque must not exceed 10 Nm.
Page 15
Page 15 of 36
Mounting guidelines for the column DL17
Mounting foot
The DL17 is supplied with 4 x MG threaded holes and 2 x M8 screws for mounting of the foot. You can use either 2 x M8 screws or 4 x MG screws dependent on your foot design. We advise you to use screws of a good quality min. 8.8 and of a suitable length, which must not go into the DL7 column further than 16 mm. The screw torque must not exceed 10 Nm in the bottom plate thread. The holes in the foot ought to be sufficiently larger than (1)6 so that it is possible to bring the foot to a level line at assembly/mounting of the table.
Mounting top
The top of the column is supplied with 4 x MG threaded holes meant for mounting onto the desk frame . We advise you to fasten the desk frame by means of 4 x MG screws of a good quality (min. 8.8) and of a suitable length of minimum 10 mm and must not go into the column further than maximum 14 mm. The screw torque must not exceed 10 Nm
Min. 10 mm
Max. 14 mm
MC 6
Top Plate
Min 10 mm
Max. 16 mm
Min. 10 mm
Max. 16 mm
Min. 10 mm
Max. 14 mm
MC 6
MC 8
Bottom Plate
MC 6
Top Plate
As the desktop amplifies the sound, we advise you to place a vibration/shock absorbing material between the desktop and the desk frame.
(Example of how to mount the DESKLINE
®
system)
Page 16
Page 16 of 36
Mounting guidelines for DB12 and DB14
For detailed information on how to mount the DB12 or the DB14, please contact LINAK A/S.
The top of the motor is supplied with holes for the self-tapping special screws.These screws together with the 2 rubber washers are supplied with the DB12/DB14. On the top of the motor there is the special rubber suspension, which should always be used when the DB12/ DB14. is mounted in a column. The top flange where the motor is mounted must be 4 mm thick ±1 mm, and the 2 mounting holes should be ø12 mm with a centre distance of 36 mm. The screw torque must be 2 Nm ±0.1 Nm.
Middle tube: For detailed information on how to mount the middle tube of your column, please contact LINAK A/S
Bottom: At the bottom of the DB12 or the DB14 the inner spindle should be mounted by means of a 22-teeth spline profile and a M5 screw in the bottom of the spindle.
Top:
Special screws
Rubber washer
Rubber suspension
Motor
Page 17
Page 17 of 36
The DB12/DB14 gives the possibility of synchronous drive of the middle profile - to make sure that the profiles are in the right place, you have to secure that both the hollow and the massive spindles are driven in the bottom position. For detailed information on how to mount the DB12/DB14, please contact LINAK A/S.
From the factory, the DB12/DB14 is delivered with the hollow spindle driven into end position. Please observe that the solid spindle may roll out during transportation/handling, but it must be rolled back to end position before mounting in the profile.
As the desktop amplifies the sound,we advise you to place a vibration/shock absorbing material between the desktop and the desk frame
Do not drive the DB12/DB14 to the outer end position before mounting. This will result in damaging the DB.
Example of how to mount the DESKLINE
®
system
Page 18
Page 18 of 36
The CBD must not be packed in heat insulating material, but must be placed so that it can emit waste heat into the surroundings. There are no ventilation holes to consider, the CBD emits heat through the surface. The plug must be visible when the CBD is mounted so that the supply to the CBD can be disconnected at replacement, if any. The mounting screws on the control box must be fastened with a max. torque of 1 Nm. The mounting surface to which the control box is attached should have a surface evenness of better than ±0.5 mm.
CBD5/CBD6 - bottom with cable grooves
The bottom of the CBD5/CBD6 is equipped with two cable grooves improving the cable management when mounting. The grooves can be used to bypass the CBD for both motor cables and the mains cable (EU version only) from one side to the other, giving a cleaner design.
Remember to lead the cables through the grooves before mounting the control box.
For mounting and operation of the desk panel, please see the separate user manual for desk panels.
Mounting guidelines CBD4/CBD5/CBD6
The control box is to be fastened with 4 screws (3 screws for the CBD5 and theCBD6) with a head diameter between ø 8 and ø 10 mm. Out of regard for the surface tension ø 10 mm is preferable due to lower surface tension. See drawing appendix for placing of mounting holes and the space the CBD takes up.
CBD4 - Control box
CBD5 - Control box
CBD6 - Control box
Page 19
Page 19 of 36
Figure 7
DP/WDPL
Mains cable
DL/DB
Hook for cable relief
Electrical connection of the DB/DL system
The DB/DL system is to be connected as shown on figure 7. The DB/DL is to be connected to the sockets on the control box by means of the motor cables, which have a 6-pin plug in each end.
Finally, the mains cable is to be mounted and power switched on. Please note that the control box must only be connected to the voltage stated on the label.
CBD4/CBD5/CBD6 with earth
The CBD4/CBD5/CBD6 earth cable to be mounted on the desk construction (typically the top frame)in a way that ensures good electrical contact. The function of the earth cable is to earth the desk and ground static electricity. The earth connection does not protect other electrical products.
CBD4/CBD5 with mains cut-off (non ZERO models)
If the power cable is damaged it has to be replaced by an authorized LINAK service centre to avoid any danger.
Page 20
Page 20 of 36
Initialisation of the DESKLINE parallel system
The DESKLINE system is initialised by pressing the down button once or twice and holding it down until the DB/DL runs into end stop. It will then automatically run approx. 5 mm out again and hereafter slowly run in again. Only release the down button when the movement has stopped completely.
If the button is released before the sequence is completed, the initialisation is interuppted and must be started again from the beginning.
The first two times the system runs into the outward end stop, it will automatically run approx. 3 mm back in inward direction.
Approx. 5 mm
The CBD5 and the CBD6 can control the DL5 and the DL6 in 2 parallel while the CBD4 can control the DL5 and the DL6 in 2, 3, and 4-parallel so that the desk is always kept horizontal.
Page 21
Page 21 of 36
Anti-Collision™
The function (anti-collision) is an option for the standard CBD4/CBD5/CBD6 advanced/control box software 0077432 version 1.66 and later. A system with anti-collision can limit material damages on a desk if a collision with a solid object should occur.
Enabling the anti-collision
To enable the anti-collision function a little plug called a dongle must be mounted in one of the 2 control ports. The function is only active when the dongle is mounted. – If you remove the dongle again, you disable the function.
Method of operation
When the DLs/DBs are running the CBD4/CBD5/CBD6 monitors the current consumption on each channel using a special algorithm. If the current consumption on one channel is increased by more than a predefined slope, a collision is assumed and all channels are stopped immediately and all DLs/DBs will start to run in the opposite direction (approx. 50 mm). This return drive is done automatically and continues with or without any control key pressed (for max. 2.5 sec.).
The anti-collision sensitivity is different in upward and downward direction. Upwards the force is approx. 20 kg. Downwards the load will be approx. 40 kg + the load on the DL/DB (the desk + what is on top of the desk). The 40 kg are needed to activate the anti-collision function.
Situations where the anti-collision does not work
There are situations where the anti-collision will not be activated. These situations are:
• If the collision happens during the initialisation phase
• If the collision happens within the first 1000 msec or after the control button has been released
• If the collision happens between the floor and the table and the load on the desk + the weight of the legs are lower than 40 kg
• If the collision happens over too long time, e.g. if the collision is with a soft object.
Page 22
Page 22 of 36
PIEZO™: description of the feature
For optimised safety against squeezing and blocking on a desk, LINAK has developed the DBs and columns with an integrated sensor, called PIEZO. The option minimises the risk for damages on a desk caused by squeezing or blocking of obstacles in up and down direction. Examples could be driving down into an office chair or into a container or up into a windowsill. To a certain extent, the system also increases the personal safety, but it does not comply with legislation describing personal safety.
PIEZO allows the DBs or columns to have the standard built-in dimension and the standard stroke length. There are no visible changes to the column.
Examples where PIEZO avoids squeezing situations.
Page 23
Page 23 of 36
Accessories and repair
Ordering accessories
Order from your nearest LINAK® dealer or subsidiary.
Accessories
Please contact your nearest LINAK dealer for information.
Repairs
Systems should only be repaired by an authorised LINAK service centre or an engineer. Systems to be repaired under warranty must be sent to an authorised LINAK service centre.
Warning!
By unauthorised opening of the system there is a risk that it may malfunction at a later date.
Spare parts
Please contact your nearest LINAK dealer for information on spare parts.
Page 24
Page 24 of 36
Disposal of LINAK products
As LINAK customers often ask us how our products can be disposed of or scrapped, we have prepared this guidance that enables a classification to different waste fractions for recycling or combustion.
Guidance
We recommend that our products be disassembled as much as possible and divided into different waste groups for recycling or combustion. For example, waste can be sorted into metals, plastics, cable scrap, combustible materials and recoverable resources.
Some of these main groups can be further divided into subgroups; e.g. metal can be divided into steel/ aluminium/copper and plastic can be divided into ABS/PA/PE/PP.
As an example, the table below breaks down the different components in LINAK products to various recycling groups:
Product Components Recycling group
Columns/ Actuator : Spindle and motor
Plastic housing Cable PC boards
Metal scrap Plastic recycling or combustion Cable scrap or combustion Electronic scrap
Control Box : PC boards
Plastic housing Cable Transformer
Electronic scrap Plastic recycling or combustion Cable scrap or combustion Metal scrap
Handset/Control : Plastic housing
Cable PC boards
Plastic recycling or combustion Cable scrap or combustion Electronics scrap
By now, almost all our casted plastic parts are supplied with an interior code for plastic types and fibre contents, if any.
Main groups of disposal
Product main groups Metal scrap Cable scrap Electronics scrap Plastic recycling
or combustin
Comments
DL12
DB12 X X X X
DL14 X X X X
DB14 X X X X
DL17
CBD4/CBD5/CBD6 X X X X
DPXX X X X
Disposal of batteries
Details regarding safe disposal of used and leaking batteries: Batteries should be disposed in accordance with appropriate federal, state and local regulations. LINAK recommends that used or leaking batteries are disposed through local recycling systems. Please do not throw used or leaking batteries in normal household waste or in nature. This will cause damage to the enviroment.
How to deal with leaking batteries
Leaking batteries should be disposed as described above. If leaking batteries are discovered in the product, the batteries must be removed at once to minimise damage to the product. If leaking batteries are left in the product, it might become defective. It is recommended to use plastic gloves when handling leaking batteries. The contents of leaking batteries can cause chemical burns and respiratory irritation. If exposed to the contents of a leaking battery, please wash with soap and water. If irritation persists, please seek medical attention. In case of eye contact, please flush eyes thoroughly with water for 15 minutes and seek medical attention."
Page 25
Page 25 of 36
Label for DL14
Label for DB14 Label for DL17Label for DL12Label for DB12
Label for CBD6
Label for CBD5
Label for CBD4
Page 26
Page 26 of 36
LINAK APPLICATION POLICY
The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware, software, technical advice, etc. related to an existing or a new customer application.
LINAK products as defined above are applicable for a wide range of applications within the Medical, Furniture, Desk and Industry areas. Yet, LINAK cannot know all the conditions under which LINAK products will be installed, used, and operated, as each individual application is unique.
The suitability and functionality of the LINAK product and its performance under varying conditions (application, vibration, load, humidity, temperature, frequency, etc.) can only be verified by testing, and shall ultimately be the responsibility of the LINAK customer using any LINAK product.
LINAK shall be responsible solely that LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specific LINAK product can be used for the application in question.
Page 27
Page 27 of 36
DRAWING APPENDIX
DL12
60
+1
0
100
+1
0
89.6
49.6
545 3.5
518
3.5
94.8
54.8
1178 1205
Page 28
Page 28 of 36
DL14
Page 29
Page 29 of 36
DL17
57.2
63.6
70
+1
0
70
+1
0
518 3.5
57.2
63.6
1178
+6.5
-4.5
Page 30
Page 30 of 36
DB12
DB14
Nominal lenght 500 3 mm
Minimum lenght retracted at max. load 496
3 mm
12
4
42
48
36
Page 31
Page 31 of 36
CBD4
3
2
1
B
A
C
B
4
278
80
100.6
119
62
51
247
5.5
5.5
CBD5
Page 32
Page 32 of 36
CBD6
Page 33
Page 33 of 36
Page 34
Page 34 of 36
Page 35
Page 35 of 36
Page 36
Page 36 of 36
Copyright
©
LINAK 2013.10 MA-M9-02-503 LINAK A/S reserve the right to make technical alterations
Terms of use
The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK. All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK.
FACTORIES
CHINA
LINAK (Shenzhen) Actuator Systems, Ltd. Phone: +86 755 8610 6656 Fax: +86 755 8610 6990 E-mail: [email protected]
www.linak.cn
SUBSIDIARIES
AUSTRALIA
LINAK Australia Pty. Ltd Phone: +61 3 8796 9777 Fax: +61 3 8796 9778 E-mail: [email protected]
www.linak.com.au
AUSTRIA
LINAK Repräsentanz Österreich (Wien) Phone: +43 (1) 890 7446 Fax: +43 (1) 890 744615 E-mail: [email protected]
www.linak.at
BELGIUM & LUXEMBOURG
LINAK Actuator-Systems NV/SA Phone: +32 (0)9 230 01 09 Fax: +32 (0)9 230 88 80 E-mail: [email protected]
www.linak.be
BRAZIL
LINAK Do Brasil Comércio De Atuadores Ltda. Phone: +55 (11) 2832 – 7070 Fax: +55 (11) 2832 – 7060 E-mail: [email protected]
www.linak.com.br
CANADA
LINAK Canada Inc. Phone: +1 502 253 5595 Fax: +1 416-255-7720 E-mail: [email protected]
www.linak-us.com
CZECH REPUBLIC
LINAK C&S S.R.O. Phone: +420581741814 Fax: +420581702452 E-mail: [email protected]
www.linak.cz
DISTRIBUTORS
ARGENTINA
Novotec Argentina SRL Phone: +[54] (11) 4303-8900 +[54] (11) 4303-8989 Fax: +[54] (11) 4032-0184 E-mail: [email protected]
www.novotecargentina.com
AUSTRALIA
Ballarat Industrial Supplies
www.ballind.com.au
BL Shipways & Co
www.blshipway.com.au
Gas Strut Marine and Industrial www.gasstrutmarine.com.au
Prime Motion & Control www.primehyd.com.au
West Vic Industrial Supplies
www.westvicindustrial.com.au
COLOMBIA
MEM Ltda Phone: +[57] (1) 334-7666 Fax: +[57] (1) 282-1684 E-mail: [email protected] www.memltda.com.co
INDONESIA
Pt. Himalaya Everest Jaya Phone: +6 221 544 8956, +6 221 544 8965 Fax: +6 221 619 4658, +6 221 619 1925 E-mail: [email protected]
www.hej.co.id
DENMARK
LINAK A/S - Group Headquarters, Guderup Phone: +45 73 15 15 15 Fax: +45 74 45 80 48 Fax: +45 73 15 16 13 (Sales) E-mail: [email protected]
www.linak.com
SLOVAKIA
LINAK Slovakia s.r.o. Phone: +421 51 75 63 414 Fax: +421 51 75 63 410 E-mail: [email protected]
www.linak.com
USA
LINAK U.S. Inc. North and South American Headquarters Phone: +1 502 253 5595 Fax: +1 502 253 5596 E-mail: [email protected]
www.linak-us.com
DENMARK
LINAK Danmark A/S Phone: +45 86 80 36 11 Fax: +45 86 82 90 51 E-mail: [email protected]
www.linak.dk
FINLAND
LINAK OY Phone: +358 10 841 8700 Fax: +358 10 841 8729 E-mail: [email protected]
www.linak.fi
FRANCE
LINAK France E.U.R.L Phone: +33 (0) 2 41 36 34 34 Fax: +33 (0) 2 41 36 35 00 E-mail: [email protected]
www.linak.fr
GERMANY
LINAK GmbH Phone: +49 6043 9655 0 Fax: +49 6043 9655 60 E-mail: [email protected]
www.linak.de
INDIA
LINAK A/S India Liaison Office Phone: +91 120 4393335 Fax: +91 120 4273708 E-mail: [email protected]
www.linak.in
IRELAND
LINAK UK Limited - Ireland Phone: +44 (0)121 544 2211 Fax: +44 (0)121 544 2552 +44 (0)796 855 1606 (UK Mobile) +35 387 634 6554 (Republic Of Ireland Mobile) E-mail: [email protected]
www.linak.co.uk
ITALY
LINAK Italia S.r.l. Phone: +39 02 48 46 33 66 Fax: +39 02 48 46 82 52 E-mail: [email protected]
www.linak.it
JAPAN
LINAK K.K. Phone: 81-45-533-0802 Fax: 81-45-533-0803 E-mail: [email protected]
www.linak.jp
MALAYSIA
LINAK Actuators Sdn. Bhd. Phone: +60 4 210 6500 Fax: +60 4 226 8901 E-mail: [email protected]
www.linak.my
NETHERLANDS
LINAK Actuator-Systems B.V. Phone: +31 76 5 42 44 40 Fax: +31 76 5 42 61 10 E-mail: [email protected]
www.linak.nl
NEW ZEALAND
LINAK New Zealand Ltd. Phone: +64 9580 2071 Fax: +64 9580 2072 E-mail: [email protected]
www.linak.co.nz
NORWAY
LINAK Norge AS Phone: +47 32 82 90 90 Fax: +47 32 82 90 98 E-mail: [email protected]
www.linak.no
POLAND
LINAK Polska Phone: +48 (22) 500 28 74 Fax: +48 (22) 500 28 75 E-mail: [email protected]
www.linak.pl
REPUBLIC OF KOREA
LINAK Korea Ltd. Phone: +82-(0)2-6231-1515 Fax: +82-(0)2-6231-1516 E-mail: [email protected]
www.linak.kr
RUSSIAN FEDERATION
000 LINAK Phone: +7 495 280 14 26 Fax: +7 495 687 14 26 E-mail: [email protected]
www.linak.ru
SPAIN
LINAK Actuadores, S.L.u Phone: +34 93 588 27 77 Fax: +34 93 588 27 85 E-mail: [email protected]
www.linak.es
SWEDEN
LINAK Scandinavia AB Phone: +46 8 732 20 00 Fax: +46 8 732 20 50 E-mail: [email protected]
www.linak.se
SWITZERLAND
LINAK AG Phone: +41 43 388 31 88 Fax: +41 43 388 31 87 E-mail: [email protected]
www.linak.ch
TAIWAN
LINAK A/S Taiwan Representative Office Phone: +886 2 27290068 Fax: +886 2 27290096 Mobile: +886 989292100 E-mail: [email protected]
www.linak.com.tw
TURKEY
LINAK İth. İhr. San. ve Tic. A.Ş. Phone: + 90 312 4726338 Fax: + 90 312 4726635 E-mail: [email protected]
www.linak.com.tr
UNITED KINGDOM
LINAK UK Limited Phone: +44 (0)121 544 2211 Fax: +44 (0)121 544 2552 E-mail: [email protected]
www.linak.co.uk
IRAN
Bod Inc. Phone: +98 2188998635-6 Fax: +98 2188954481 E-mail: [email protected]
www.bod.ir
PERU
Percy Martin Del Aguila Ubillus Phone: +51 99-883-9879
RUSSIAN FEDERATION
000 FAM Phone: +7 812 3319333 Fax: +7 812 3271454 E-mail: [email protected]
www.fam-drive.ru
SINGAPORE
Servo Dynamics Pte. Ltd. Phone: +65 6844 0288 Fax: +65 6844 0070 E-mail: [email protected]
www.servo.com.sg
SOUTH AFRICA
Industrial Specialised Applications CC Phone: +27 11 312 2292 or +27 11 2077600 (Switch Board) Fax: +27 11 315 6999 E-mail: [email protected] www.isaza.co.za
UNITED ARAB EMIRATES
Mechatronics Phone: +971 4 267 4311 Fax: +971 4 267 4312 E-mail: [email protected] www.mechatronics.ae
For contact details on other countries please visit www.linak.com or contact:
LINAK INTERNATIONAL
Phone: +45 73 15 15 15 Fax: +45 74 45 90 10 Fax: +45 73 15 16 13 (Sales) E-mail: [email protected]
www.linak.com
Loading...