Linak DL12, DB12, DL17 systemwith CBD4, CBD5, CBD6 User Manual

...
Page 1 of 36
USER MANUAL
DL12, DB12, DL14, DB14, DL17 system with CBD4, CBD5 or CBD6
To learn more about LINAK, please visit:
WWW.LINAK.COM
Page 2 of 36
Page 3 of 36
Contents
Preface ............................................................................................................................................... 4
Important information ....................................................................................................................... 5
Safety instructions .............................................................................................................................. 5
General .......................................................................................................................................... 5
Before installation, reinstallation or troubleshooting ........................................................................ 6
Before start-up ............................................................................................................................... 6
During operation ............................................................................................................................ 6
Misc. .............................................................................................................................................. 6
Only for EU markets........................................................................................................................ 7
Only for Non EU markets ................................................................................................................ 7
Misuse ............................................................................................................................................ 7
Repairs ............................................................................................................................................... 8
Manufacturer’s declaration ................................................................................................................ 8
Misc. on the DESKLINE
®
system ......................................................................................................... 9
Warranty ........................................................................................................................................ 9
Maintenance .................................................................................................................................. 9
Description of the DESKLINE
®
system ............................................................................................. 10
Mounting guidelines for the DL14 system ...................................................................................... 11
Mounting top .............................................................................................................................. 11
Mounting foot ............................................................................................................................. 13
Mounting guidelines for the column DL12 .................................................................................... 14
Mounting top .............................................................................................................................. 14
Mounting foot ............................................................................................................................. 14
Mounting guidelines for the column DL17 .................................................................................... 15
Mounting top .............................................................................................................................. 15
Mounting foot ............................................................................................................................. 15
Mounting guidelines for DB12 and DB14 ...................................................................................... 16
Mounting guidelines for the CBD4/CBD5/CBD6S ........................................................................... 18
Electrical connection of the DB/DL system ..................................................................................... 19
Initialisation of the DESKLINE parallel system ................................................................................ 20
Anti-Collision
TM
.................................................................................................................................. 21
PIEZO
TM
: description of the feature ................................................................................................ 22
Accessories and repair ...................................................................................................................... 23
Disposal of LINAK products .............................................................................................................. 24
Labels ............................................................................................................................................. 25
Drawing appendix ............................................................................................................................ 27
Declaration of conformity ................................................................................................................ 33
Addresses .......................................................................................................................................... 36
Page 4 of 36
Preface
We are delighted that you have chosen a product from LINAK A/S. LINAK systems are high-tech products based on many years of experience in the manufacture and development of actuators, electric control boxes, controls, and chargers.
We are also constantly improving our products to meet customer requirements.
This User Manual will tell you how to install, use and maintain your LINAK DESKLINE
®
products.
We are sure that the DESKLINE
®
products will give you many years of problem-free operation. Before our products leave the factory they undergo full function and quality testing. Should you nevertheless experience problems with your systems, you are always welcome to contact our service departments or service centres.
LINAK subsidiaries and distributors all over the world have authorised service centres, which are always ready to help you.
LINAK provides a warranty on all its products. This warranty, however, is subject to correct use in accordance with the specifications, maintenance being done correctly and any repairs being carried out at a service centre, which is authorised to repair LINAK products.
Changes in installation and use of LINAK systems can affect their operation and durability. Changes must therefore only be made by agreement with LINAK A/S and are made at your own risk.
LINAK A/S
Page 5 of 36
Safety instructions
General
Important information
Important information on LINAK
®
products can be found under the
following headings:
Warning!
Failure to comply with these instructions may result in accidents involving serious personal injury.
Failing to follow these instructions can result in the product being damaged or being destroyed.
Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed.
Failure to comply with instructions marked with the ”NOTE” symbol may result in serious damage to the system or one of its components.
It is important for everyone who is to connect, install or use the systems to have the necessary information and access to this User Manual. Follow the instructions for mounting – risk of injury if these instructions are not followed.
The appliance is not intended for use by young children or infirm persons without supervision.
If there is visible damage on the product, it must not be installed.
Note that during construction of applications, in which the actuator is to be fitted, there must be no possibility of personal injury, for example squeezing of fingers or arms.
Assure free space for movement of applications in both directions to avoid blockade.
Page 6 of 36
Before installation, reinstallation, or troubleshooting
• Stop the DB/DL.
• Switch off the power supply and pull out the mains plug.
• Relieve the DB/DL of any loads, which may be released during the work.
Before start-up:
• Make sure that the system has been installed as instructed in this User Manual.
• Make sure that the voltage at the control box is correct before the system is connected to the mains.
• System connection. The individual parts must be connected before the control box is connected to the mains. See the User Manual for LINAK actuators, if necessary.
During operation:
• If the control box makes unusual noises or smells, switch off the mains voltage immediately.
• Take care that the cables are not damaged.
• Unplug the mains cable on mobile equipment before it is moved.
Misc.
The actuator system has a sound level below 55dB(A) in typical applications.
Updated manuals and declarations can always be found here:
www.linak.com/deskline
Page 7 of 36
Only for EU markets
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Only for Non EU markets
Persons who do not have the necessary experience or knowledge of the product/products must not use the product/products. Besides, persons with reduced physical, sensory or mental abilities must not use the product/products, unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons.
Moreover, children must be under surveillance to ensure that they do not play with the product.
It is the operator’s responsibility to ensure that there is free space for the application to move without risk for the operator or bystanders before operating the application.
Misuse
Do not overload the actuators – this can cause danger of personal injury and damage to the system.
Do not use the actuator system for lifting persons. Do not sit or stand on a table while operating – risk of personal injury.
Do not use the system in environments other than the intended indoor use
Page 8 of 36
Repairs
In order to avoid the risk of malfunction, all DESKLINE® repairs must only be carried out by authorised LINAK workshops or repairers, as special tools must be used and special gaskets must be fitted. Lifting units under warranty must also be returned to authorised LINAK workshops.
Warning!
If any of the DESKLINE
®
products are opened, there will be a risk of subsequent malfunction.
Warning!
The DESKLINE
®
systems do not withstand cutting oil.
Page 9 of 36
Misc. on the DESKLINE® system
Warranty
There is a 36 months’ warranty on DESKLINE products against manufacturing faults from the production date of the individual products (see label). LINAK A/S warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with. Furthermore, the system must not be exposed to violent treatment. In the event of this, the warranty will be ineffective/invalid. For further details, please see standard terms of sale and delivery for LINAK A/S.
Maintenance
Clean dust and dirt on the outside of the system at appropriate intervals and inspect them for damage and breaks. Inspect the connections, cables and plugs and check for correct functioning as well as fixing points.
Service of double insulated products:
Class II
A Class II or double insulated electrical appliance is one which has been designed in such a way that it does not require a safety connection to electrical earth (US: ground). The basic requirement is that no single failure can result in dangerous voltage becoming exposed so that it might cause an electric shock and that this is achieved without relying on an earthed metal casing. This is usually achieved at least in part by having two layers of insulating material surrounding live parts or by using reinforced insulation. There is no earthing/grounding means provided on the product, and no earthing/grounding means is to be added to the product. In Europe, a double insulated appliance must be labelled “Class II”, “double insulated” or bear the double insulation symbol (a square inside another square). Servicing a double-insulated product requires extreme care and knowledge of the system, and is to be done only by qualified service personnel. Replacement parts for a double insulated product must be identical to the parts they replace.
The cleaners and disinfectants must not be highly alkaline or acidic (pH value 6-8).
Page 10 of 36
Description of the DESKLINE® system
Each DESKLINE® actuator/column is equipped with a motor and parallel/memory drive is ensured by means of software in the CBD4/CBD5/CBD6 that also takes account of an oblique load on the desk. Soft start and stop are also part of this software, which ensures a soft start and stop when adjusting the desk.
Application of the DESKLINE
®
system:
Irrespective of the load, the duty cycle 10% ~ 6 min./ hour or max. 2 min. at continuous use stated in the data sheets, must NOT be exceeded as this will result in a superheating of the motor and the control box. Exceeding the duty cycle will result in a dramatic reduction of the life of the system.
The DB/DL system range contains following products:
• 1 control box CBD4/CBD5/CBD6
• DL12, DB12, DL14, DB14 or DL17 (1 - 4)
• 1 exchangeable mains cable
• motor cables (1 - 4)
• 1 DP1U/DPF1M (if memory function is required) DP1C//DPT/DPF1C (if memory function and display are required) or 1 DPA/DPB/DP1K/DP1V/DPFK (if only up/down is required).
Page 11 of 36
Mounting guidelines for the DL14 system
Mounting top
The top of the column is supplied with 4 M6 threaded holes meant for mounting onto the desk frame. We advise you to fasten the desk frame by means of 4 pcs. M6 screws of a good quality (min. 8.8) and of a suitable length, which must not go further than max. 14 mm into the column. The thrust moment must not exceed 10 Nm.
Screw length Min. B + 9 mm Max. B + 14 mm