PRODUCT DATA SHEET
HB80 HANDSET
Features:
• Handset for up to 5 actuators
• Coiled or straight cable
• Colour: Dark grey (RAL 7016), grey (RAL 7035) or black (RAL 9005) (only plastic housing, check available cables and front covers)
• Protection class: IP54
• Up to 12 easy-touch buttons for OPENBUS™ and Matrix (CB20 and CB14)
Options:
• Customised front cover
• Memory options
• Simultaneous drive of actuators
• Background lighting blue or green (for use with the Openbus™ system)
• IP66 Washable
Usage:
• Approved according to: EN 60601-1 as part of a LINAK actuator system
The HB80 is a new handset with an optimised ergonomic design and switch activation.
The HB80 handset is designed in 2 versions.
One has up to 10 big activation bottons. This can be used for almost all kinds of MEDLINE and CARELINE applications.
For advanced MEDLINE applications such as spe­cial hospital beds a 6 row version is available with 12 activation bottons.
The HB80 has an option of blue or green back­ground lighting for use with the LINAK CB20 control box (Openbus applications).
The HB80 is available in several different stand­ard versions with a variation of bed symbols for easy interaction with end-users.
Page 2
Dimensions (mm): HB81 - HB85
Dimensions (mm): HB86
Precautions:
• The HB86 version has a shorter distance between the buttons and cannot be approved according to EN 1970.
HB80
Ordering example:
HB8 1 0 01
5+01006
Cable ID
Box colour
Front cover
Background light
Functionality
0x (HB40 like) for: CB6, (CB6 with 3 ch. = ch.1, 3 and 4) CB7, CB8, CB18
(max. 3 channels) TDC, CBJH, sometimes CB9..AX and CB12 - see also Hx
Ex (Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14 EF (Matrix) for: CB140 Hx (HB40 like, common gnd) for: CB9..Ax and CB12 with simultaneous drive EW (Memory / Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14 Vx (OPENBUS™ functionality)
Cable length
ID Total Coiled Color Plug
01 850 mm 600 mm Grey DIN 8P 03 850 mm 600 mm Black DIN 8P 11 750 mm 500 mm Grey DIN 8P (7 wires max. HB83) 13 750 mm 500 mm Black DIN 8P (7 wires max. HB83) 21 2400 mm 0 mm Grey DIN 8P (7 wires max. HB83) 23 2400 mm 0 mm Black DIN 8P (7 wires max. HB83) 31 2400 mm 0 mm Grey DIN 8P 33 2400 mm 0 mm Black DIN 8P 45 850 mm 600 mm Dark Grey MJ RJ45 10P (not for OPENBUS) 61 850 mm 600 mm Grey MJ RJ45 10P (6 wires) 63 850 mm 600 mm Black MJ RJ45 10P (6 wires)
+
=
Grey - RAL7035 (not for CB6)
-
=
Black (not for CB6)
=
=
Dark grey - RAL7016 (Only for CB6)
See later pages
0 = no 1 = green (ONLY Openbus™) 2 = blue (ONLY Openbus™)
Housing
IP rating
Number of rows (exclusive rows for memory)
HB-type
5 ROW based - big bottons only 1 - 5 ROWs
5
6 ROW based - small bottons
6
IP54
4
IP66 washable
9
1 - 5 rows - Big bottoms 6 rows - Small bottoms
Page 3
x
x
2
x
x
2
x
x
2
x
x
2
x
x
7
Precautions
Cables: ID4x used for CB6 ID6x used for OPENBUS™ and CBJH
Functionality overview for HB8x :
0x (HB40 like) for: CB6 (CB6 with 3 ch. = ch.1,3 and 4), CB7, CB8, CB18 (max. 3 channels), TDC, CBJH, sometimes CB9..AX and CB12 - see also Hx Ex (Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14 EF (Matrix) for: CB140 Hx (HB40 like, common gnd) for: CB9..Ax and CB12 with simultaneous drive EW (Memory / Matrix) for: CB9..Px (not CB9..PM/..PN) and CB14 Vx (OPENBUS™ functionality)
Functionality explanation:
The digits above along with the functionality drawings are to be used as part of the product item number.
• In the ordering example, there is a space reserved for 2 “functionality” digits.
• I.e. if you need an HB82 you can e.g. choose between “00” and “E0” functionalities.
• “00” functionality is compatible with CB6, CB7, CB8,…… ;
• “Hx” functionality is compatible with CB9..AX and CB12 with sim. drive.
Functionalities:
Simultaneous/Trend
HB82
02/H
HB83
02/H
HB84
02/H
HB85
02/H
HB85
07/H
3+4U 3+4D 1U 1D 1U 1D 1U 1D
3D4U 3U4D 3+4U 3+4D 2U 2D 2U 2D
3D4U 3U4D 3+4U 3+4D 1+2U 1+2D
3D4U 3U4D 3+4U 3+4D
3D4U 3U4D
1U 1D
3+4U 3+4D
2U 2D
1+2U 1+2D
3D4U 3U4D
Page 4
Functionalities:
x
x
0
x
x
0
x
x
0
x
x
0
x
x
x
x
x
x
C
x
x
C
x
xEW
x
xEW
x
x
F
6
9
HB81
00/E
1U 1D 1U 1D 1U 1D 1U 1D
HB82
00/E
2U 2D 2U 2D 2U 2D
HB83
00/E
HB84
00/E
HB85
E0/E
01/E1 HB83
HB82
HB86
2U 2D
1U 1D
01/E1
3U 3D 3U 3D
4U 4D
HB81
0C/E
1U 1D 1U 1D 2U 2D
D4U4
HB82
0C/E
2U 2D 1U 1D
4U 4D
5U 5D
HB85
3U 3D
12
3S
D3U3
3U 3D
4U 4D
12
3S
Jumbo functionalities
HB82xx0
CBJ2/CBJH
HB83xx0
HB83xx0A
U1U1U1
D1D1D1
2U 2D 2U 2D
CBJH
CBJ2
HB83xx0B
1U slow
(1U) (2U)
1D slow
(1D) (2D)
2U 2D
(3U) (3D)
CBJ1
1U fast
1D fast
Page 5
Functionalities:
x
x
3
x
x
3
x
x
3
x
x
5
x
x
5
x
x
5
x
x
x
x
x
x
6
x
x
7
x
x
7
x
x
x
x
x
x
Simultaneous
HB82
03/H
HB83
03/H
HB84
03/H
HB84
04/H4 HB85
04/H4
1U 1D 1U 1D 1U 1D
3+4U 3+4D 2U 2D 3U 3D
3+4U 3+4D 4U 4D
3+4U 3+4D
05/H
HB82
3U 3D 3U 3D 3U 3D
1+2U 1+2D 1+2U 1+2D 1+2U 1+2D
HB84
07/H
HB83
05/H
4U 4D 4U 4D
HB84
0A/HA HB85
HB84
05/H
3+4U 3+4D
0A/HA HB85
2U 2D 2U 2D
1U 1D 1U 1D
3U 3D 3U 3D
2+3U 2+3D 2+3U 2+3D
4U 4D
HB84
06/H
HB83
07/H
D4+3U4+3
0B/HB
1U 1D 1U 1D 1U 1D
3U 3D 3U 3D 3U 3D
2U 2D 2U 2D 2U 2D
D2+1U2+1
1+2U 1+2D 1+2U 1+2D 1+2U 1+2D
D4D4U4
Page 6
x
xV0
x
x
x
xV2
x
xV0
x
x
x
xV2
x
xV0
x
x
x
xV2
Functionalities:
x
xV0
x
x
x
xV2
x
xV0
x
x
x
xV2
x
xV0
x
x
x
xV2
HB81
HB82
HB81
V1 HB81
HB83
HB83
V1 HB83
HB82
HB82
HB84
V1
HB84
V1 HB84
HB86
HB86
H2 H3 H12 H13 H22 H23
H0 H1 H10 H11 H20 H21
H4 H5 H14 H15 H24 H25
H6 H7 H16 H17 H26 H27
H8 H9 H18 H19 H28 H29
H28 H29 H30 H31 H30 H31
V1 HB86
HB85
H2 H3 H12 H13 H22 H23
H0 H1 H10 H11 H20 H21
H4 H5 H14 H15 H24 H25
H6 H7 H16 H17 H26 H27
H8 H9 H18 H19 H28 H29
HB85
V1 HB85
For more functionalities contact LINAK.
Page 7
Various HB standard front covers
1
2
A
8
-
B
0
H
0
0
00HB861B-001 00HB861B-00200HB841A-001 00HB851A-002 00HB841A-002
0
2
00HB811A-001
00HB821A-002 00HB831A-002 00HB841A-003 00HB851A-005
Page 8
Various HB standard front covers
00HB851D-001 00HB831A-001
00HB821A-001
00HB811A-004
HB80 Standard front covers - when ordering check that the handset functionality corresponds to the symbols on the front cover. The last 2 digits in the front cover code are to be used in the ordering example (xx).
For all types attention should be given to ensure that the channels shown correspond to the channels on the chosen control box.
It is the responsibility of the product user to determine the suitability of LINAK A/S products for a specific application. LINAK will at point of delivery replace/repair defective products covered by the warranty if promptly returned to the factory. No liability is assumed beyond such replacement/repair.
LINAK 2008.02 . MA M9-02-226-B . Chapter 9.18
©
Copyright
Specifications subject to change without prior notice.
Loading...