Lika SMAG-GA-100-...+MTAG-300, SMAG-GA-100-...+MTAG-370, SMAG-GA-50-...+MTAG-650, SMAG -GA-100-, SMAG-GA-100-... +MTAG-220 User Manual

...
User's guide
SMAG + MTAG
SMAG absolute linear encoder
MTAG guided profile unaffected by dust and liquids
Measuring length from 115 to 570 mm
Resolution range from 0.1 mm to 0.005 mm
SSI interface, LSB Right Aligned protocol
SMAG -GA-100-...
SMAG -GA-50-...
SMAG -GA-10-...
SMAG -GA-5-...
Table of Contents
Preliminary information 5 1 – Safety summary 6 2 - Identification 8 3 – Mechanical installation 9 4 – SSI interface 12 5 - Maintenance 19
Lika Electronic Tel. +39 0445 806600 info@lika.biz www.lika.biz
Smart encoders & actuators
This publication was produced by Lika Electronic s.r.l. 2017. All rights reserved. Tutti i diritti riservati. Alle Rechte vorbehalten. Todos los derechos reservados. Tous droits réservés.
This document and information contained herein are the property of Lika Electronic s.r.l. and shall not be reproduced in whole or in part without prior written approval of Lika Electronic s.r.l. Translation, reproduction and total or partial modification (photostat copies, film and microfilm included and any other means) are forbidden without written authorisation of Lika Electronic s.r.l.
The information herein is subject to change without notice and should not be construed as a commitment by Lika Electronic s.r.l. Lika Electronic s.r.l. reserves the right to make all modifications at any moments and without forewarning.
This manual is periodically reviewed and revised. As required we suggest checking if a new or updated edition of this document is available at Lika Electronic s.r.l.'s website. Lika Electronic s.r.l. assumes no responsibility for any errors or omissions in this document. Critical evaluation of this manual by the user is welcomed. Your comments assist us in preparation of future documentation, in order to make it as clear and complete as possible. Please send an e-mail to the following address info@lika.it for submitting your comments, suggestions and criticisms.

Table of contents

User's guide......................................................................................................................................................... 1
Table of contents............................................................................................................................................ 3
Typographic and iconographic conventions..............................................................................................4
Preliminary information................................................................................................................................ 5
1 – Safety summary....................................................................................................................................... 6
1.1 Safety.......................................................................................................................................................................................... 6
1.2 Electrical safety.......................................................................................................................................................................6
1.3 Mechanical safety..................................................................................................................................................................7
2 - Identification............................................................................................................................................ 8
3 – Mechanical installation.......................................................................................................................... 9
3.1 Overall dimensions (Figure 1)...........................................................................................................................................9
3.2 Mounting instructions.........................................................................................................................................................9
3.3 Sensor (Figure 2)..................................................................................................................................................................10
3.4 Profile of the magnetic tape (Figure 2).....................................................................................................................11
3.5 Measuring length (Figure 1)...........................................................................................................................................11
3.6 Standard counting direction (Figure 2).....................................................................................................................11
4 – SSI interface........................................................................................................................................... 12
4.1 Electrical connections.......................................................................................................................................................12
4.1.1 M8 cable specifications............................................................................................................................................12
4.1.2 M12 8-pin connector specifications...................................................................................................................12
4.1.3 Connection of the shield.........................................................................................................................................13
4.1.4 Ground connection....................................................................................................................................................13
4.1.5 Zero setting input.......................................................................................................................................................13
4.1.6 Counting direction input.........................................................................................................................................14
4.2 SSI (Synchronous Serial Interface)...............................................................................................................................15
4.3 LSB Right Aligned protocol.............................................................................................................................................16
4.4 Recommended transmission rates...............................................................................................................................18
4.5 Recommended SSI circuit................................................................................................................................................18
5 - Maintenance........................................................................................................................................... 19

Typographic and iconographic conventions

In this guide, to make it easier to understand and read the text the following typographic and iconographic conventions are used:
parameters and objects both of the device and the interface are coloured in GREEN;
alarms are coloured in RED;
states are coloured in FUCSIA.
When scrolling through the text some icons can be found on the side of the page: they are expressly designed to highlight the parts of the text which are of great interest and significance for the user. Sometimes they are used to warn against dangers or potential sources of danger arising from the use of the device. You are advised to follow strictly the instructions given in this guide in order to guarantee the safety of the user and ensure the performance of the device. In this guide the following symbols are used:
This icon, followed by the word WARNING, is meant to highlight the parts of the text where information of great significance for the user can be found: user must pay the greatest attention to them! Instructions must be followed strictly in order to guarantee the safety of the user and a correct use of the device. Failure to heed a warning or comply with instructions could lead to personal injury and/or damage to the unit or other equipment.
This icon, followed by the word NOTE, is meant to highlight the parts of the text where important notes needful for a correct and reliable use of the device can be found. User must pay attention to them! Failure to comply with instructions could cause the equipment to be set wrongly: hence a faulty and improper working of the device could be the consequence.
This icon is meant to highlight the parts of the text where suggestions useful for making it easier to set the device and optimize performance and reliability can be found. Sometimes this symbol is followed by the word EXAMPLE when instructions for setting parameters are accompanied by examples to clarify the explanation.

Preliminary information

This guide is designed to provide the most complete information the operator needs to correctly and safely install and operate the linear encoders with guided profile of the SMAG series that provide SSI interface and Gray output code. The SMAG sensors are engineered to measure linear displacements in industrial machines and automation lines. The measuring system consists of a magnetic tape mounted on a rigid profile and a magnetic sensor. The tape has a coded sequence of poles; the distance between two poles is referred to as “pole pitch”. The sensor moves along the magnetic tape (or, on the contrary, the magnetic tape is moved under the sensor), thus the sensor detects the displacement and issues an output signal equivalent to the one generated by an absolute encoder or an optical linear scale. The sensor must be compulsorily paired with the MTAG magnetic tape. The measuring length is from 115 mm (4.528”) to 570 mm (22.441”), see the order code.
For technical specifications please refer to the product datasheet.
To make it easier to read the text, this guide can be divided into some main sections.
In the first section (from chapter 1 to chapter 3) some general information concerning the safety, the mechanical installation and the electrical connection as well as tips for setting up and running properly and efficiently the SMAG linear encoder + MTAG are provided.
In the second section, entitled SSI Interface (chapter 4), you can find detailed information on the SSI interface.
SMAG + MTAG SSI

1 – Safety summary

1.1 Safety

Always adhere to the professional safety and accident prevention regulations
applicable to your country during device installation and operation;
installation and maintenance operations have to be carried out by qualified
personnel only, with power supply disconnected and stationary mechanical devices;
device must be used only for the purpose appropriate to its design: use for
purposes other than those for which it has been designed could result in serious personal and/or the environment damage;
high current, voltage and moving mechanical parts can cause serious or fatal
injury;
warning ! Do not use in explosive or flammable areas;failure to comply with these precautions or with specific warnings elsewhere
in this manual violates safety standards of design, manufacture, and intended use of the equipment;
Lika Electronic assumes no liability for the customer's failure to comply with
these requirements.

1.2 Electrical safety

Turn OFF the power supply before connecting the device;connect according to the explanation in the ”4.1 Electrical connections”
section on page 12;
connect Zero Setting input to 0Vdc, if not used; to zero set the encoder,
connect Zero setting input to +Vdc for 100 µs at least, then disconnect +Vdc; normally voltage must be at 0Vdc; zero set must be performed after Counting direction setting; we suggest performing the zero set when the encoder is in stop;
connect Counting direction input to 0Vdc, if not used; to have count up
information when the measuring system moves as shown in Figure 2 (see the arrows) = connect to 0Vdc; to have count up information when the measuring system moves in the direction opposite to the movement shown in Figure 2 (see the arrows) = connect to +Vdc;
in compliance with 2014/30/EU norm on electromagnetic
compatibility, following precautions must be taken:
- before handling and installing the equipment, discharge electrical charge from your body and tools which may come in touch with the device;
- power supply must be stabilized without noise; install EMC filters on device power supply if needed;
- always use shielded cables (twisted pair cables whenever possible);
- avoid cables runs longer than necessary;
- avoid running the signal cable near high voltage power cables;
- mount the device as far as possible from any capacitive or inductive noise source; shield the device from noise source if needed;
- to guarantee a correct working of the device, avoid using strong magnets on or near by the unit;
MAN SMAG GA E 1.3.odt 1 – Safety summary 6 of 20