LightwaveRF LW931 Instruction Manual

Page 1
Professional Series
www.lightwaverf.house
Instruction Manual
Version 2.1
Magnetic Trigger
Model No. LW931
Page 2
EC DECLARATION OF CONFORMITY
Tel: +44 (0)121 250 3625 Email: enquiries@lightwaverf.com
Model Number(s): JSJSLW931 Description: Magnetic Trigger Directives this equipment Complies with: 2006/95/EC The Low Voltage Directive N/A 2004/108/EEC The Electromagnetic Compatibility Directive 1999/5/EC R&TTE Directive 93/68/EEC CE Marking Directive
Standards Applied in order to verify compliance
Safety: BS EN 60730-1: 2011
Health: R&TTE: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08) EN 300 220-1 V2.1.1: 2006, EN 300 220-2 V2.1.2: 2007 EMC: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08), EN 55022: 2010, EN 61000-3-2: 2006 +A1: 2009 +A2: 2009 Class A, EN 61000-3-3: 2008, EN61000-4-2: 2009, EN 61000-4-3: 2006 +A1: 2008 +A2: 2010, EN 61000-4-4: 2012, EN 61000-4-5: 2006, EN 61000-4-6: 2009, EN 61000-4-11: 2004
For and on behalf of LightwaveRF PLC
---------------------------------------­Name J Shermer Position Managing Director
Page 3
How does it work?
How do I get started?
The following setup guide will explain how to install and use the Magnetic Trigger with other LightwaveRF heating devices.
The Magnetic Trigger can directly link to and control LightwaveRF heating devices such as the Thermostatic Radiator Valve (TRV), Home or Room Thermostat or Electric Switch. When the door or window that the trigger is attached to is opened or closed, the radiator in the room will be turned o or on.
Help video & further guidance
For additional guidance, and to watch a video that will help guide you through the installation process, please visit the support section on
www.lightwaverf.com
Get Started
Page 4
IMPORTANT: Please retain these instructions for guidance on how to link other LightwaveRF devices to the Magnetic Trigger. For additional guidance please visit www.lightwaverf.com
Battery
compartment
catch
LED indicator
Overview
Linking button
Magnet section
Line up the dots
when two sections
are attached to a
window / door
Main section
Installation
Page 5
2 x AAA batteries can be inserted under the battery cover at the rear of the device. This can be removed by pulling down on the catch and gently unhooking the cover from the hooks at the base of the unit.
IMPORTANT: In the battery compartment there is a slider switch marked A/B. Setting the switch to position A causes an ‘o’ command to be sent when a window or door is opened. Setting it to position B will cause an ‘on’ command to be sent.
Inserting the batteries
Attaching to a door or window and frame
The Magnetic Trigger can be attached to a window frame using adhesive pads provided or by using suitable screws inserted through the mounting holes in the back cover.
IMPORTANT: When mounting, the two dots on each sections must line up vertically with no more than 2-3mm between the sections (as in the picture). The two dots also need to be within 10mm of each other in terms of depth. The indicator LED will light up on opening / closing if the sections have been mounted correctly.
2-3mm
Installation
Page 6
How to use the Magnetic Trigger
Each LightwaveRF Magnetic Trigger can be used to turn on and o a LightwaveRF TRV, Electric Switch or Thermostat if a window or door is opened or closed.
The trigger will automatically setback a TRV, an Electric Switch or Thermostat (default of 11 degrees) if a window is opened and return them to their previous set temperature when the window is closed again. The trigger will interupt any set schedule for the LightwaveRF heating device if activated, but return to the schedule once closed.
Device setup
Page 7
To directly control a LightwaveRF TRV, Thermostat or Electric Switch using a Magnetic Trigger, you will need to ‘link’ them. The trigger can be linked to these devices using the following method:
1. Press and release the ‘Linking’ button on the Magnetic
Trigger (the LED will flash).
2. Press and release the Linking button on the TRV,
Electric Switch or Thermostat that you wish to link to. The ‘on’ LED should flash to indicate a successful link.
Note: linking mode lasts for 12 seconds; if no linking command is received within this time, then linking mode will time out and the process will have to be re-initiated.
To completely clear the memory of the Switch and unlink any linked devices, press and release the Linking button to enter linking mode (the LEDs will flash). Then, hold the Linking button until the LEDs flash rapidly. Finally, press and release the Linking button once more. The LED will flash more slowly to confirm that the memory has been cleared.
Linking the trigger to a TRV, Electric Switch or Thermostat
Device setup
Page 8
Lightwave Link
(runs the show)
Electric Switch
(controls electric radiators)
Heating Remote
(sets house temp.)
Magnetic Trigger
(open window turns o TRV)
TRV
(controls radiator)
Room by room radiator control
Lightwave App
(control from anywhere)
Boiler OR Electric Switch
(turns boiler on/o)
Home Thermostat
(monitors house temp.)
Home or Away button
(turn house on/o)
Add other heating devices
Page 9
Problem: The LED does not illuminate when the window / door is opened.
Solution: The trigger is not mounted correctly. Ensure that the two dots line
up on each section, that there is less than 10mm difrerence in the depth of the dots, and ensure that there is only a 2-3 gap (max) between the sections when closed.
Problem:
The trigger no longer functions and the LED does not illuminate.
Solution: Check the batteries. The average battery life should be at least
one year, although this will vary depending on use. The LED indicator will flash ten times to report a low battery status. If this measure fails, there may be a fault. Please contact technical support via www.lightwaverf.com.
Problem: The trigger turns the TRV on rather than o when opened.
Solution: This is because the A/B Switch inside the battery compartment is
switched to position B rather than position A. Moving the slider to position A will reverse the on/o commands and turn the TRV o when the window is open.
Troubleshooting
Page 10
Q. How do I know that the trigger will fit my window frame? A. The Trigger can be mounted to most window or door frames and has a
degree of flexibility to accomodate dierent types. As long as the two sections of the Trigger can be made to match up together, the device will work.
Q. Can I link more than one TRV to a trigger? A. You can currently only link one TRV directly. .
Q. Is it legal for me to install a LightwaveRF devices myself? A. Yes, LightwaveRF products are fully legal to install in your own home.
Q. How long do the batteries last? A. This can vary, but a minimum of one year can be expected with normal use.
FAQs
Page 11
Specification
RF frequency: 868 MHz
Batteries: 2 x 1.5V (AAA)
Warranty: 2 year standard warranty
Technical Specification
Page 12
Version 2.1
2 Quadrant Park
Mundells
Welwyn Garden City
Herts
AL7 1FS
01707 386035
www.lightwaverf.house
Loading...