LightwaveRF JSJSLW452 Instruction Manual

Page 1
lightwaveRF
Connect Series
2-Way Dimmer (2 Gang)
Model Nos. JSJSLW452
Instruction Manual
www.megamanuk/lightwaverf.com
Page 2
Page 3
Get Started
How do I get started?
If the Dimmer has already been installed, refer to the quick setup guide on the following pages to get going. If you are planning to install the Dimmer, please refer to the installation instruc­tions that follow quick setup. This will guide you through the installation process.
Help Video
You can scan this QR code with your smartphone. It will take you to a video that will help guide you through setup and installation.
To install the Dimmer, you will need to remove and replace the existing lightswitch. This is usually straightforward, but you must ensure that there is a suitably deep housing (backbox) and understand how to safely turn o the electricity supply. You will also need suitable electrical screwdrivers.
Page 4
IMPORTANT: Please retain these instructions for guidance on how to link Remote Handsets and other LightwaveRF Controllers. For additional guidance please visit www.megamanuk.com/lightwaverf
Amber LED.
When illuminated,
Dimmer is o.
‘On’ Button.
Hold to raise light
level.
‘O’ Button.
Hold to lower light
level.
Blue LED. When
illuminated,
Dimmer is on.
Overview
Quick Setup Guide
Page 5
Quick Setup
Quick Setup Guide
Tap either ‘on’ (top) button once to switch the Dimmer on (Blue LED indicator will illuminate). Press and hold the on button to raise the light level.
Tap either ‘o’ (bottom) button once to switch the Dimmer o (Amber LED indicator will illuminate). Press and hold to lower the light level.
Manual Dimming
Page 6
Quick Start Guide
NOTE: it is important to install this product in accordance with the following instructions. Failure to do so may void your warranty.
LightwaveRF is fully legal to install in your own home. However, if in doubt, always consult a qualified electrician.
Installation
Switched live
(live out)
Screw
Mounting
hole
Live in
2-Way
Switching
Connection
Installation
Page 7
The 2-Way Dimmers use standard 3-core connecting cables; however, because they are electronic dimmers, they utilise one of the cores as a signal cable (‘S’) running between the Dimmers (as shown on the diagram). This is low voltage only and should not be connected to 230V mains; serious damage will occur.
Up to six 2-Way Dimmers (six gangs) can be connected to a standard LightwaveRF Dimmer Switch. Each 2-Way can be connected directly to the standard Dimmer, or connected to each other in a ‘daisy-chain’. This provides an alternative to using intermediate switches (maximum cable length of 100m).
VERY IMPORTANT
A LightwaveRF 2-Way Dimmer (each gang) needs to be used in conjunc­tion with a standard LightwaveRF Dimmer to perform 2-Way Switching. The
LightwaveRF 2-Way Dimmer cannot be used in conjunction with a standard lightswitch. This will cause damage to the Dimmer.
Never install and run power to a 2-Way Dimmer before first installing and connecting the corresponding standard LightwaveRF Dimmer. Serious damage could be caused to the unit.
Installation
Page 8
1. IMPORTANT: Turn o the mains electrical supply.
2. Ensure that the wall (back) box has a minimum depth of 35mm.
3. Remove and disconnect the existing light switch (if applicable). It may be
useful at this point to mark out or take a photograph of the connections to the existing switch so that the correct wires can easily be transferred to the new Dimmer. Some existing wiring configurations can be complex so take care.
4. Gently remove Dimmer faceplate by inserting a screwdriver into the
bottom slot/s and lifting away from the unit as shown.
Installation
Page 9
5. Connect the wiring as per the wiring diagram on the following page.
Ensure that the terminals are properly tightened and that no bare wire is visible. Be aware that existing wiring circuits are not always correctly coloured, and that there may be other wired connections present in the back box; if in doubt, always seek the advise of a qualified electrician.
NOTE: The 2-Way Dimmer does NOT require a mains neutral wire to be connected; it only requires ‘live in’, ‘switched live out’ and a ‘signal’ connection.
7. Screw the Dimmer Switch to the
mounting box and ensure that the screws are suciently tight to support the product, but do not over tighten as this may cause the chassis to bend. Ensure that the plastic spacer is correctly aligned and that no wires are trapped between the Dimmer Switch and the back of the back box.
6. Any earth wires present must be attached either to the earth terminal
located in the back box or capped with a strip connector. The Dimmers are double insulated so are not required to be earthed directly.
Installation
Page 10
Installation
IMPORTANT: The signal cable input marked ‘S’ must ONLY be connected to the wire running to the other Dimmer NOT live mains; this will cause irreparable damage.
3-Core Cable
From Lighting Circuit
Live
Live
Earth
Switched Live
Signal Cable
Switched Live
Standard Dimmer 2-Way Dimmer
Page 11
8. Replace the plate – a ‘click’ sound
should be heard to signify that the plate has been correctly replaced.
Important things to Consider
Wattage ratings for the Dimmers are
per gang. The maximum circuit
load for each 2-Way Dimmer Gang is equal to the maximum load on the standard LightwaveRF Dimmer it is connected to (i.e. 250W or 210W).
Installation
ONLY Dimmable lamps can be used even if the Dimmers are used solely to switch between the on and o states without dimming. This is because the technology used in an electronic dimmer is fundamentally dierent to that of a simple on/o switch and requires compatible lamp technology.
NOTE: Compatibility between electronic Dimmers and LEDs can be aected if the total circuit loading is very small. Total LED load decreases (relatively) as it is shared between a greater number of connected Dimmers; therefore, as more 2-Way Dimmers (up to 6) are added to a single circuit, it is possible that LED performance may become less stable.
Page 12
Compatibility
Ensuring the compatibility of your lamps (bulbs) with LightwaveRF Dimmers will ensure that you get the best experience from your lighting setup.
LightwaveRF Dimmers are compatible with
• Standard mains voltage incandescent, Eco Halogen & low energy
incandescent lighting (min 20W, max 250W)
• GU10 and equivalent HI spot mains halogen lamps
• Dimmable Electronic Low Voltage Transformers (20W - 250W max.)
• Inductive Transformers (40 – 170VA max.)
• Selected dimmable (only) LED lamps (see www.lightwaverf.com for
compatibility guide).
LightwaveRF Dimmers are NOT compatible with
• Wirewound transformers (generally older style)
• Electric motors
• Non dimmable LEDs
• CFLs
• CFL tube arrays
Compatibility & Lamps
Page 13
Troubleshooting
Problem: The 2-Way Dimmer will not operate the lights and the LEDs on
the Dimmer do not light up.
Solution: Firstly, check that there is power to the Dimmer. Make sure that
the connected lamps (bulbs) are functioning correctly; the Dimmer Switch will not run unless it has a functioning lamp/s to complete the circuit. Ensure that the maximum LED/incandescent loading has not been exceeded (if so this may have damaged the Dimmer). Check that the wiring is correct; it is important that the live, switched live and signal wires are attached to the correct terminals; a common mistake is to reverse the live and switched live connections. Remember, the signal terminal must NOT be
connected to 230V mains. If these measures fail, contact technical support
via www.lightwaverf.com.
Problem: The 2-Way Dimmer has power (LEDs on) but will not turn on
the
Lights/turns on then o by itself/ will not operate from the other Dimmer.
Solution: Check that the wiring is correct; it is important that the live,
switched live and signal wires are attached to the correct terminals; a common mistake is to reverse the live and switch live connections which may cause the 2-Way Dimmer to function improperly. Remember, the signal terminal must NOT be connected to 230V mains. If these measures fail, contact technical support via www.lightwaverf.com.
Page 14
Problem: The LED/CFL lamps that I am using flash / do not dim properly. Solution: Ensure that the lamps being used are dimmable; non dimmable
lamps are not compatible with LightwaveRF Dimmers. If the problem persists, the LED/CFL lamps may not be compatible with the Dimmers; please contact technical help (via www.lightwaverf.com) for further advice.
Problem: The 2-Way Dimmer will not link to a LightwaveRF controller. Solution: The 2-Way Dimmer is not designed to link to a LightwaveRF
controller and therefore does not contain an RF radio module. This is because it takes direct commands, instead, from the corresponding standard LightwaveRF Dimmer via the connected signal wire. The standard LightwaveRF Dimmer can be linked to a controller and passes on commands to the 2-Way Dimmer automatically.
Problem: The Dimmer keeps turning o automatically / will not turn o. Solution: The connected standard LightwaveRF Dimmer may be Locked.
This may have been done using a Socket Locker or from the LightwaveRF App. If it is locked on, then the 2-Way Dimmer will not turn o manually. If it is locked o, it will be possible to turn the Dimmer on, but it will automatically turn o again after five minutes. To unlock the Dimmer, press the unlock button on the Socket Locker or Smartphone App. If this is not possible, the Dimmers can be reset by turning of mains power to the circuit for a period of 30 seconds.
Troubleshooting
Page 15
Q. Can I link the 2-Way Dimmer to a LightwaveRF controller? A. No. The 2-Way Dimmer is designed to take wired commands directly
from the standard Dimmer that it is connected to. It does not contain an RF module and will not enter linking mode.
Q. How do I know that the Dimmer Switch will fit?
A. The Dimmer is the same size as a standard lightswitch - it will fit all back
boxes (standard lightswitch housing) over 35mm deep.
Q. Is it legal for me to install the Dimmer?
A. Yes, LightwaveRF is fully legal for you to install in your own home.
Q. Is there a maximum number of lamps I can control with the Dimmer?
A. You can control any number of lamps (bulbs) as long as they do not exceed
the maximum loading in total. Note: Max. load diers for LED/incandescent.
Q. How many devices can I have on the LightwaveRF system?
A. Each device has 6 memory slots for up 6 controllers (one of these can be
the Lightwave Link allowing up to 6 smartphones to control hundreds of
devices.
Q. Can I use LED or CFL lamps?
A. Most LEDs can be controlled as long as the lamps are dimmable variants
(see www.lightwaverf.com for guidance). CFLs are not compatible.
FAQs
Page 16
Q. Can I use non dimmable lamps (bulbs) if I don’t dim them?
A. No. The lamps must be dimmable even if they are not dimmed; the
technology in the lamp must be compatible with that of the Dimmer.
Q. What if I need a switch to operate on/o only?
A. A LightwaveRF Relay in conjunction with a Wire-free Switch can be used
for on/o switching in place of the Dimmer (see www.lightwaverf.com).
Q. Can I separate and change individual switches in multigang Dimmers?
A. Multigang Dimmers are not designed to have their switch modules
separated and interchanged; disconnecting and removing Dimmer Modules will invalidate the warranty.
Q. What Happens after a power cut?
A. Standard LightwaveRF Dimmers default to the o position after a power
cut. The 2-Way Dimmer will, therefore, also default to o. This can be overrid­den using the Lightwave Link to set default status for devices on power up. See www.lightwaverf.com for details.
Q. Is it normal for the Dimmer to get warm when it is turned on?
A. Yes it is perfectly normal for Dimmer Switches to feel warm to the touch if
left on for a period of time close to maximum load. It is completely safe.
FAQs
Page 17
Specification
Input rating: 220-240V~ 50Hz.
Output rating: 3W~250W max (per gang)
Incandescent Load: 20W min 250W max (per gang)
Back Box Depth: 35mm min.
Earthing Requirement: Not essential (double insulated)
Standby Energy Use: Less than 1W (per gang)
Wiring: Neutral wire NOT required
Warranty: 2 year standard warranty
Technical Specification
Page 18
www.megamanuk.com/lightwaverf
lightwaveRF
2 Quadrant Park
Mundells
Welwyn Garden City
Herts
AL7 1FS
01707 386035
Loading...