1 Gang 1 Way Dimmer 250w
Operation Manual
Model No: JSJS LW250
OVERVIEW:
connect
Blue LED ‘ON’ Amber LED ‘OFF’
It is important to install this product in accordance with the tting instructions below. Failure to do so may render your guarantee void.
Page 2
FITTING AND WIRING INSTRUCTIONS:
Important Things to Consider Before you Begin
1). Before commencing work, ALWAYS isolate the mains power supply and remove the fuse in the fuse box or switch o the circuit breaker in the consumer unit.
2). If unit is to be used as a replacement for an existing product, remove existing unit from its location and disconnect the wiring. Ensure that the wall (back) box has a minimum depth of 25mm.
3). Certain items in the range will not t into a 4-lug box. If such a box has been previously installed the North-South lugs should be removed or bent back to avoid contact with the new product.
4). Connect the wires as shown in appropriate wiring diagrams. Use green/yellow sleeving on any earth conductors not insulated. Ensure terminals are properly tightened and no bare wire is visible. When mounting products into mounting boxes make sure conductors are not trapped.
5). When screwing the unit to the mounting box, do not over-tighten xing screws. Fixing screws are supplied with this product.
6). To reduce the risk of discolouration or tarnishing, avoid installation on wet plaster.
7). Products must be installed in accordance with the latest building and IEE wiring regulations. If in any doubt, please contact a qualied electrician.
Page 3
Compatibility
The LightwaveRF Slave Dimmer is compatible with:
• Standard mains voltage incandescent & low energy
incandecent lighting (min 40W, max 250W)
• Dimmable Electronic Low Voltage Transformers
• GU10 and equivalent HI spot mains halogen bulbs
The 1 gang LightwaveRF Slave Dimmer is NOT compatible with:
• Wire-wound transformers (generally older models)
• Electric Motors
Please Note:
• Master units must be installed
• Units can ONLY be operated manually: the slave unit
will not operate with a LightwaveRF RF remote.
For a full, up to date list of all compatible bulbs, including LEDs and CFLs, please refer to www.lightwaverf.com.
Installation Guide
1. Turn o mains electrical supply.
2. Ensure that the wall (back) box has a minimum depth of 25mm.
3. Remove the existing light switch and disconnect the wiring.
4. Gently remove plate by inserting a at screwdriver into the slots/s of the plate and lift away from the unit.
Page 4
Page 5
5. Strip the cable as shown then connect the wiring as per the diagrams below, ensure terminals are properly tightened and no bare wire is visible.
Additional slave units (maximum of 6 in line) will allow for 2-way / multi-way operation (units can only be operated manually).
Max: 8mm Min: 13mm
2-Way Switching
Page 6
Multi-Way
6. Screw the dimmer switch to the mounting box and ensure that the screws are suciently tight to support the product, but please do not over tighten as this may cause some damage. Ensure that the plastic spacer is correctly aligned and that no wires are trapped between the dimmer switch and the back of the wall box.
Page 7
7. Replace the plate – a ‘click’ sound should be heard to signify that the plate has been correctly replaced.
OPERATION:
Please Note:
• At least one master unit must be installed in order
for slave unit to operate.
• The LED indicators on master unit and slave unit
ash simultaneously.
Switch ‘ON/OFF’
Manual ‘ON’ Button
Press once to switch ‘ON’ (Blue LED indicator will illuminate).
Manual ‘OFF’ Button Press once to switch ‘OFF’ (Amber LED indicator will illuminate).
Page 8
Dimming Control on the Receiver
Lowering Dim Level
1. Make sure the light is switched on.
2. Hold down the ‘OFF’ button.
3. After 1 sec. the light will start to dim down.
4. At the desired brightness level release the ‘OFF’ button.
NOTE: If the ‘OFF’ button is not released, the light will continue to dim until no light is emitted and stop, although the switch remains on, illustrated by the illuminated blue LED.
Raising Dim Level
1. Make sure the light is switched on.
2. Hold down the ‘ON’ button.
3. After 1 second the light will start to become brighter.
4. At the desired brightness release the ‘ON’ button.
NOTE: If the ‘ON’ button is not released, the light level will increase until it stops at the maximum possible level of brightness.
If after setting a dim level the light is then switched o, the next time the light is switched on the light level will automatically return to the same setting.
Page 9
SPECIFICATION (per module):
Input rating: 220-240V~ 50Hz. Output rating: 40~250W Max. Incandescent lamp, 200VA Max.