1 Gang 1 Way Dimmer 250w
Operation Manual
Model No: JSJS LW250
OVERVIEW:
connect
Blue LED ‘ON’ Amber LED ‘OFF’
IMPORTANT: PLEASE RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE AND FOR GUIDANCE ON
THE ASSOCIATION OF REMOTE HANDSETS. FOR
HELP AND SETUP GUIDANCE PLEASE VISIT
www.lightwaverf.com
It is important to install this product in accordance
with the tting instructions below. Failure to do so
may render your guarantee void.

FITTING AND WIRING INSTRUCTIONS:
Important Things to Consider Before you Begin
1). Before commencing work, ALWAYS isolate the
mains power supply and remove the fuse in the fuse
box or switch o the circuit breaker in the consumer
unit.
2). If unit is to be used as a replacement for an existing
product, remove existing unit from its location and
disconnect the wiring. Ensure that the wall (back) box
has a minimum depth of 25mm.
3). Certain items in the range will not t into a 4-lug
box. If such a box has been previously installed the
North-South lugs should be removed or bent back to
avoid contact with the new product.
4). Connect the wires as shown in appropriate wiring
diagrams. Use green/yellow sleeving on any earth
conductors not insulated. Ensure terminals are
properly tightened and no bare wire is visible. When
mounting products into mounting boxes make sure
conductors are not trapped.
5). When screwing the unit to the mounting box, do
not over-tighten xing screws. Fixing screws are
supplied with this product.
6). To reduce the risk of discolouration or tarnishing,
avoid installation on wet plaster.
7). Products must be installed in accordance with the
latest building and IEE wiring regulations. If in any
doubt, please contact a qualied electrician.

Compatibility
The LightwaveRF Slave Dimmer is compatible with:
• Standard mains voltage incandescent & low energy
incandecent lighting (min 40W, max 250W)
• Dimmable Electronic Low Voltage Transformers
• GU10 and equivalent HI spot mains halogen bulbs
The 1 gang LightwaveRF Slave Dimmer is NOT
compatible with:
• Wire-wound transformers (generally older models)
• Electric Motors
Please Note:
• Master units must be installed
• Units can ONLY be operated manually: the slave unit
will not operate with a LightwaveRF RF remote.
For a full, up to date list of all compatible bulbs,
including LEDs and CFLs, please refer to
www.lightwaverf.com.
Installation Guide
1. Turn o mains electrical supply.
2. Ensure that the wall (back) box has a minimum
depth of 25mm.
3. Remove the existing light switch and disconnect
the wiring.
4. Gently remove plate by inserting a at screwdriver
into the slots/s of the plate and lift away from the
unit.

5. Strip the cable as shown then connect the wiring
as per the diagrams below, ensure terminals are
properly tightened and no bare wire is visible.
Additional slave units (maximum of 6 in line) will
allow for 2-way / multi-way operation (units can only
be operated manually).
Max: 8mm
Min: 13mm
2-Way Switching

Multi-Way
6. Screw the dimmer switch to the mounting box and
ensure that the screws are suciently tight to support
the product, but please do not over tighten as this
may cause some damage. Ensure that the plastic
spacer is correctly aligned and that no wires are
trapped between the dimmer switch and the back of
the wall box.

7. Replace the plate – a ‘click’ sound should be heard
to signify that the plate has been correctly replaced.
OPERATION:
Please Note:
• At least one master unit must be installed in order
for slave unit to operate.
• The LED indicators on master unit and slave unit
ash simultaneously.
Switch ‘ON/OFF’
Manual ‘ON’ Button
Press once to switch ‘ON’ (Blue LED indicator will
illuminate).
Manual ‘OFF’ Button
Press once to switch ‘OFF’ (Amber LED indicator will
illuminate).

Dimming Control on the Receiver
Lowering Dim Level
1. Make sure the light is switched on.
2. Hold down the ‘OFF’ button.
3. After 1 sec. the light will start to dim down.
4. At the desired brightness level release the ‘OFF’
button.
NOTE: If the ‘OFF’ button is not released, the light will
continue to dim until no light is emitted and stop,
although the switch remains on, illustrated by the
illuminated blue LED.
Raising Dim Level
1. Make sure the light is switched on.
2. Hold down the ‘ON’ button.
3. After 1 second the light will start to become
brighter.
4. At the desired brightness release the ‘ON’ button.
NOTE: If the ‘ON’ button is not released, the light level
will increase until it stops at the maximum possible
level of brightness.
If after setting a dim level the light is then switched
o, the next time the light is switched on the light
level will automatically return to the same setting.

SPECIFICATION (per module):
Input rating: 220-240V~ 50Hz.
Output rating: 40~250W Max.
Incandescent lamp, 200VA Max.
Low voltage lighting electronic transformers.
Manual ON/OFF with dimmer function.
Birmingham Science Park Aston
Faraday Wharf
Holt Street
Birmingham
B7 4BB
Tel: 01902 500 562
Email: support@jsjsdesigns.com