Lightwave JSJSLW400 Instruction Manual

Connect Series
www.lightwaverf.com
Dimmer Switch (1 Gang)
Model No. JSJSLW400
Instruction Manual
Version 2
EC DECLARATION OF CONFORMITY
Tel: +44 (0)121 250 3625 Email: enquiries@lightwaverf.com
Model Number(s): JSJSLW400 Description: Dimmer Switch Directives this equipment Complies with: 2006/95/EC The Low Voltage Directive N/A 2004/108/EEC The Electromagnetic Compatibility Directive 1999/5/EC R&TTE Directive 93/68/EEC CE Marking Directive
Standards Applied in order to verify compliance
Safety: BS EN 60730-1: 2011
Health: R&TTE: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08) EN 300 220-1 V2.1.1: 2006, EN 300 220-2 V2.1.2: 2007 EMC: EN 301 489-1 V1.9.2: (2011-09), EN 301 489-3 V1.4.1: (2002-08), EN 55022: 2010, EN 61000-3-2: 2006 +A1: 2009 +A2: 2009 Class A, EN 61000-3-3: 2008, EN61000-4-2: 2009, EN 61000-4-3: 2006 +A1: 2008 +A2: 2010, EN 61000-4-4: 2012, EN 61000-4-5: 2006, EN 61000-4-6: 2009, EN 61000-4-11: 2004
For and on behalf of LightwaveRF PLC
---------------------------------------­Name J Shermer Position Managing Director
Get Started
What do I need?
How do I get started?
To install the dimmer, you will need to remove and replace the existing lightswitch. This is usually straightforward, but you must ensure that there is a suitably deep housing (backbox) and understand how to safely turn o the electricity supply. You will also need suitable electrical screwdrivers.
Please refer to the following installation and setup instructions. This will guide you, step by step, through the installation and setup process.
Help video & further guidance
For additional guidance, and to watch a video that will help guide you through the installation process, please visit the support section on
www.lightwaverf.com
Amber LED.
When illuminated,
dimmer is o.
‘On’ button.
Hold to raise light
level.
‘O’ button.
Hold to lower light
level.
Blue LED. When
illuminated, the
dimmer is on.
Overview
Installation
IMPORTANT: All LightwaveRF products can be legally DIY installed in your own home; however, if in doubt, always consult a qualified electrician or heating engineer. It is important to install this product in accordance with the following instructions. Failure to do so may void your warranty.
Switched live
(live out)
Screw
mounting
hole
Live in
2-Way
switching
connection
Installation
IMPORTANT: If conducting an insulation resistance test, all LightwaveRF products must be disconnected from the mains, or damage will occur.
Quick Start Guide
Installation
1. IMPORTANT: Turn o the mains electrical supply.
2. Ensure that the wall (back) box has a minimum depth of 35mm.
3. Remove and disconnect the existing lightswitch (if applicable). It may be
useful at this point to mark out or take a photograph of the connections to the existing switch so that the correct wires can easily be transferred to the new dimmer. Some existing wiring configurations can be complex so take care.
4. Gently remove the dimmer faceplate by inserting a screwdriver into one
of the bottom slots and lifting away from the unit as shown.
Installation
5. Connect the wiring as per the wiring diagram on the following page.
Ensure that the terminals are properly tightened and that no bare wire is visible. Be aware that existing wiring circuits are not always correctly coloured, and that there may be other wired connections present in the back box; if in doubt, always seek the advice of a qualified electrician.
NOTE: LightwaveRF dimmers do NOT require a mains neutral wire to be connected; they only require ‘live in’ and ‘switched live out’.
7. Screw the dimmer switch to the
mounting box and ensure that the screws are suciently tight to support the product, but do not over tighten as this may cause the chassis to bend. Ensure that the plastic spacer is correctly aligned and that no wires are trapped between the dimmer switch and the back box.
6. Any earth wires present must be attached either to the earth terminal
located in the back box or capped with a strip connector. The dimmers are double insulated so are not required to be earthed directly.
Installation
Signal cable connection for use with LightwaveRF 2-Way Dimmer only (LOW VOLTAGE: Do not connect to live mains!)
Earth wire connects to terminal in back box (can be capped o instead if no terminal present)
Live wire In. This should be brown or red in colour.
Switched live Wire Out. This should be blue or black in colour.
The switched live may be marked by brown/red tape to emphasise that it is not a neutral wire.
Installation
8. Replace the plate – a ‘click’ sound
should be heard to signify that the plate has been correctly replaced.
It is recommended that LightwaveRF devices be positioned at least 30cm apart in order to prevent the risk of any radio conflict that could disrupt remote operation.
Suitable lamps must be used with the dimmer or it will not function correctly. See next section for compatibility information.
Important things to consider
In a multigang dimmer, to be able to operate any gang, mains electricity must always be connected to all of the dimmer terminals.