13A 2 Gang Switched Socket
Operation Manual
Model No: JSJS LW270
OVERVIEW:
connect
IMPORTANT: PLEASE RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE AND FOR GUIDANCE ON
THE ASSOCIATION OF REMOTE HANDSETS. FOR
HELP AND SETUP GUIDANCE PLEASE VISIT
www.lightwaverf.com
It is important to install this product in accordance
with the tting instructions below. Failure to do so
may render your guarantee void.

FITTING AND WIRING INSTRUCTIONS:
Important Things to Consider Before you Begin
1). Before commencing work, ALWAYS isolate the
mains power supply and remove the fuse in the fuse
box or switch o the circuit breaker in the consumer
unit.
2). If unit is to be used as a replacement for an existing
product, remove existing unit from its location and
disconnect the wiring. Ensure that the wall (back) box
has a minimum depth of 25mm.
3). Certain items in the range will not t into a 4-lug
box. If such a box has been previously installed the
North-South lugs should be removed or bent back to
avoid contact with the new product.
4). Connect the wires as shown in appropriate wiring
diagrams. Use green/yellow sleeving on any earth
conductors not insulated. Ensure terminals are
properly tightened and no bare wire is visible. When
mounting products into mounting boxes make sure
conductors are not trapped.
5). When screwing the unit to the mounting box, do
not over tighten xing screws. Fixing screws are
supplied with this product.
6). To reduce the risk of discolouration or tarnishing,
avoid installation on wet plaster.
7). Products must be installed in accordance with the
latest Building and IEE wiring regulations. If in any
doubt, please contact a qualied electrician.

Installation Guide
1. Turn o mains electrical supply.
2. Ensure that the wall (back) box has a minimum
depth of 25mm.
3. Remove the existing socket and disconnect the
wiring.
4. Gently remove plate by inserting a at screwdriver
into the slots/s of the plate and lift away from the
unit.

Max: 8mm
Min: 13mm
4. Connect the wiring as per the diagrams below,
making sure all wires are fully inserted into the
terminals and fully tightened.
NOTE: Bare each individual wire approximately
8-13mm, and then screw in tightly into the
terminals.

Additional slave units (maximum of 6 in line) will
allow for 2-way / multi-way operation (units can only
be operated manually).
5. Gently screw the socket into the wall (back) box,
making sure that the plastic spacers are correctly
aligned and that no wires are trapped between the
socket and the back of the wall box.

6. Replace the plate – a ‘click’ sound should be heard
to signify that the plate has been correctly replaced.
SETUP:
Pairing with handheld Remote transmitters
Each socket can pair with up to 6 dierent remote
transmitters at any one time as it has a maximum of
6 memories.
NOTE: If the RF range between the transmitter and
receiver is too great to achieve reliable operation,
the LightwaveRF SIGNAL BOOSTER may be used in
conjunction with this product to increase the signal
strength over greater distances.

Pairing using LEARNING MODE:
1. Ensure the socket is connected the amber LED will
be illuminated.
2. Press and hold down the ‘MANUAL’ button on the
socket to be paired, until the blue and amber LEDs
ash alternately (this refers to either the left OR the
right socket depending on which of the ‘MANUAL’
buttons was pressed). The socket is now in learning
mode.
3. Using a LightwaveRF Connect Remote press one of
the ‘ON’ buttons; the blue light on the socket will ash
to conrm that the remote is now paired.
NOTE: Learning Mode lasts for 6 seconds; if no signal
is received from a remote handset during this time
then the socket will automatically exit learning mode
without pairing the device.
If, when expecting a blue LED ash to conrm pairing,
amber ash is received instead, then this means that
the socket memory is FULL and no further remotes
may be paired with it unless one of the existing
remotes is rst unpaired (see below).
Unpairing Remotes & clearing the Socket memory
Removing single Device:
1. Ensure the socket is connected, the amber LED will
be illuminated.
2. Press and hold down the ‘MANUAL’ button on the
socket until the blue and amber LEDs ash alternately.
The socket is now in learning mode.

3. Using a LightwaveRF Connect Remote press one of
the ‘OFF’ buttons; the amber light on the socket will
ash to conrm that the remote is now unpaired.
Clearing Memory (will remove all paired remotes):
1. Ensure the socket is connected and ready with a
mains power line and load.
2. Press and hold down the ‘MANUAL’ button on the
socket until the blue and amber LEDs ash
alternately. The socket is now in learning mode.
3. On the socket press and hold down the ‘MANUAL’
button again until the blue and amber LEDs ash
simultaneously, then press (don’t hold) the ‘MANUAL’
button a further time; the amber LED will ash
conrm that the memory has been cleared.
OPERATION:
Switch ‘ON/OFF’
‘MANUAL’ Buttons (switch ‘ON/OFF’ function)
Press once to switch ‘ON’ (Blue LED indicator will light
ON).
Press once again to switch ‘OFF’ (Amber LED indicator
will light ON).

SPECIFICATION:
220~240V~50Hz
Max. 13A
Resistive Load
RF frequency: 433.92 MHz
BS1363
Amber / Blue LED indicator.
Manual ON / OFF function.
Birmingham Science Park Aston
Faraday Wharf
Holt Street
Birmingham
B7 4BB
Tel: 01902 500 562
Email: support@jsjsdesigns.com