Lights Lucid sirius 190, Lucid sirius 290, Lucid sirius 490, Lucid sirius DALI, Lucid sirius 1-10 V Operation, Installation And Service Instructions

LIGHTS 4 Europe GmbH & Co. KG ∙ Gaildorfer Str. 6 ∙ D-71522 Backnang Tel. +49 7191 323020 ∙ Fax +49 7191 323029 ∙ info@lights.de
1
www.lights.de
Operation, installation and service instructions
Lucid sirius | LED luminaire
Please read these instructions before installing the luminaires,
using them for the first time, storage or handling.
These installation and service instructions, edition V3.0, apply to the LED
luminaire Lucid sirius 190 / Lucid sirius 290 / Lucid sirius 490 /
Lucid sirius DALI / Lucid sirius 1-10 V
2
www.lights.de
LIGHTS 4 Europe GmbH & Co. KG ∙ Gaildorfer Str. 6 ∙ D-71522 Backnang Tel. +49 7191 323020 ∙ Fax +49 7191 323029 ∙ info@lights.de
IG_Lucid_
sirius_DE_23
.06.2017_V3.0 - Similar to illustrations, technical data are subject to change
Introduction
Dear customer, Many thanks for buying this product from us and for the trust you have placed in us.
Please read these operating, installation and service instructions carefully before using the product.
These instructions are aimed at suitable qualified persons (e.g. electricians, installers or engineers) tasked with installation and maintenance of this product. It applies for all versions of the Lucid sirius LED luminaire. LED luminaire in the Lucid sirius range are intended for professional use indoors.
Technical personnel must be familiar with all technical electrical directives and safety precautions, and apply these appropriately in each case.
These instructions are not suitable or intended for users and consumers without specialist technical knowledge.
For questions concerning handling the luminaire, which are not answered in these instructions, please contact:
LIGHTS 4 Europe GmbH & Co. KG
Gaildorfer Str. 6 71522 Backnang Germany Telephone +49 7191 323020 Telefax +49 7191 323029 Email: info@lights.de
We wish your every success with our product and hope you enjoy saving energy
3
www.lights.de
LIGHTS 4 Europe GmbH & Co. KG ∙ Gaildorfer Str. 6 ∙ D-71522 Backnang Tel. +49 7191 323020 ∙ Fax +49 7191 323029 ∙ info@lights.de
IG_Lucid_
sirius_DE_23
.06.2017_V3.0 - Similar to illustrations, technical data are subject to change
Product description & applications
The LED luminaire in the Lucid sirius range come complete with an integrated power supply / driver for op­erating the luminaire.
The Lucid sirius is suitable for professional use in industrial, production and warehouse buildings and for working areas.
The Lucid sirius is subject to quality checks in accordance with European standards. The luminaire stand out not only because of their modern design, but above all because of a number of special technical fea­tures, which guarantee the best possible technical performance. These include highly-efficient lens optics, high-quality housing materials, constant current control, temperature monitoring, as well as lifelong regula­tion of luminous flux. The working temperature of -30 to 40 °C facilitates a wide range of applications.
Test standards
The Lucid sirius was tested by the TÜV SÜD and ENEC and fulfils the requirements of the European guide­lines EN55015:2006/A2:2009, EN 61547:2009, EN, 60598-1: 2008 +A11: 2009, EN 60589-2-1:1985 and EN 60589-1:2015.
Labels
To help precise identification of the product, you will find information about the model and item number on the type plate. We recommend you make a note of this information so it is available if you have any ques­tions later. This will help us handle your query more quickly.
4
www.lights.de
LIGHTS 4 Europe GmbH & Co. KG ∙ Gaildorfer Str. 6 ∙ D-71522 Backnang Tel. +49 7191 323020 ∙ Fax +49 7191 323029 ∙ info@lights.de
IG_Lucid_
sirius_DE_23
.06.2017_V3.0 - Similar to illustrations, technical data are subject to change
Symbols
By using the CE mark, the manufacturer confirms that the product conforms to the ap­plicable, product specific European directives.
None of the components in this product exceeds the permissible thresholds for use of hazardous materials in accordance with the RoHS directive 2011/65/EU
The ENEC (European Norms Electrical Certification) is a test mark referring to lumi­naires (with the exception of emergency lighting) for office, multimedia and household devices and confirms the conformance with the European statutory requirements and enables an easier market access in these product areas within the EU, the EFTA coun­tries and in many countries in Eastern Europe.
The IP protection classification system categories the level of protection which a hous­ing for electrical devices offers against solids (e.g. dust) and liquids (water, oil etc.). IP66 means 6 = dust-proof and 5= Protected against ingress of water jets from any angle
The luminaires is only to be used indoors
All electrically conductive housing components in the equipment are connected to the protective conductor system of the fixed electrical installation, which is at earth poten­tial.
An electrical product marked with this symbol may not be disposed of in domestic waste.
5
www.lights.de
LIGHTS 4 Europe GmbH & Co. KG ∙ Gaildorfer Str. 6 ∙ D-71522 Backnang Tel. +49 7191 323020 ∙ Fax +49 7191 323029 ∙ info@lights.de
IG_Lucid_
sirius_DE_23
.06.2017_V3.0 - Similar to illustrations, technical data are subject to change
Installation - general safety instructions
CAUTION - DANGER OF ELECTROCUTION
Only appropriate technical personnel may work on electrical systems. There is a risk of fatal electrocution. Before working on electrical systems and switching units, they should be removed from the power supply and secured against accidental re-connection. Before touching conductive components and cables, use ap­propriate equipment to confirm they are actually isolated from the power supply.
First read the operating instructions through completely, as they contain important information for correct
fitting and operation.
Any damage caused by non-compliance with these operating instructions invalidates the warranty/guar-
antee! We do not accept any liability for direct or consequential damages!
We do not accept any liability for personal or property damage caused by improper use or non-compli-
ance with the safety instructions! In these cases, the warranty/guarantee is invalidated!
The product may not be opened (please also read the instructions in the chapter MAINTENANCE).  The light source in these luminaires is not replaceable. When the light source has reached the end of its
life, the whole light must be replaced
Do not install the product on a damp or conductive surface.  To avoid any hazard, a damaged outer flexible lead on this light may only be replaced by the manufac-
turer, their representative or a comparable qualified person.
Only install the product in switched-off mode.  Only install the product in intended electrical systems and voltage ranges. Check and compare the infor-
mation on this on the product’s type plate.
If a fault occurs, disconnect the product from the mains power supply and any other connected devices.
Then ensure neither can be switched on again accidentally.
If you cannot guarantee that the product can be operated without any danger, disconnect the product
immediately from the mains power supply and any other connected devices. Once more, ensure neither can be switched on again accidentally. It is not possible to guarantee that the product can be operated without any danger when, for example, the housing or power cable is damaged, or if any foreign objects have penetrated it.
Use suitable, approved power cables and cable connectors / clips of an adequate size. Make sure the
cables sit firmly in the connectors. Any loose or exposed cables represent an extremely high risk of elec­tric shock and fire.
When working under roofs, on masts or any other high fitting sites, ensure you are on a solid base by
using approved, certified ladders, or risers, as well as fall protection for personnel, tools and the product to be installed. Cordon off the area under the installation area adequately.
Caution: Please consult specialists before using the luminaires in high ambient temperatures or chemi-
cally polluted environments.
Loading...
+ 10 hidden pages