LEDS: 48 3 Watt LEDs (tricolor 3 in 1 RGB)
Beam angle: 25 º
Control system: DMX-512
DMX channels: 3
DMX connectors: 3 pin XLR
Voltage: 120 VAC 50/60Hz
Max power consumption: 200 Watts
Size (LxWxH): 17 3/8" 12 1/4" x 8 1/4 "
Body material: Cast Aluminum
Body color: Black
Weight: 17.6 lbs
DESCRIPTION
The FXLD348R3I is a RGB LED lighting fixture. It
is suitable for stage, disco, night club, and other artistic
applications. It has several stand alone control modes,
a master/slave mode, and can operate via a DMX-512
external signal.
A double yoke enables it to be operated in several
positions.
INSTALLATION
LOCATION
The FXLD348R3I is rated IP20 and is intended for
INDOOR USE ONLY.
Locate the unit in a well ventilated area away from
moisture and heat. Holes are provided on the yokes to
install a lighting bar pipe clamp. A safety cable should
also be used.
POWER CONNECTIONS
The FXLD348R3Ihas a line cord for connection to a
120 VAC, 15 Amp, 60Hz, grounded service.
RISK OF ELECTRIC SHOCK
CAUTION
The safety ground pin on the power cord must be used.
DMX CONNECTIONS
A system using DMX control should be connected as a
chain of devices. In other words the control signal
cable should proceed from the controller to the first
receiving device and then to others in a continuous
"daisy chain" fashion.
The fixture has a DMX IN and a DMX OUT connector
to be used to connect the chain. The control cable
should NOT be split into a multiple run star
arrangement with a cable running from the controller
directly to each receiving device pack.
DMX CONNECTOR PIN ASSIGNMENTS
There are two different connectors which can be used
for DMX control. They are both XLR type connectors.
Some units use 3 pin connectors. Others use 5 pin
connectors. The FXLD348R3Ireceives a DMX signal
on the 3 pin MALE connector on the back of the unit.
The 3 pin FEMALE connector is used to connect the
next DMX device on the control chain. If your console
uses a 5 pin connector you can make up an adapter
cable to accommodate this. The table below shows the
pin assignments for BOTH the 3 pin and 5 pin
connectors.
DMX TERMINATION
IN # SIGNAL NAME
1 DMX COMMON
2 DMX DATA 3 DMX DATA +
4 NOT USED
5 NOT USED
A DMX chain should be terminated at the last
receiving device on the chain. This is done by
installing a commonly available 1/4 Watt, 120 Ohm
resistor across the DATA - and DATA + wires at the
www.lightronics.com
Lightronics Inc. 509 Central Drive Virginia Beach, Va 234354 757 486 3588
Page 2 of 5
FXLD348R3I LED FIXTURE
Version 0.1 OWNERS MANUAL 02/16/2012
last device. If you have only a few fixtures very close
together and a very short run to the controller then you
may be able to operate without the terminator.
OPERATION
A control panel on one side of the unit is used to set the
operating options. It consists of an LED display and
four buttons
(MENU, UP, DOWN, and ENTER)
CONTROL PANEL
Push
UP
MENU UP DOWNENTER
MENU
to access the operating options. Then use
and
DOWN
to scroll through the available choices.
When you reach the option you want to set or change -
ENTER
push
for the option and/or change it. Push
. Now you can view the current setting
ENTER
to save
your changes and activate the option. See the "MENU
NAVIGATION" diagram for additional details.
There are 7 operation modes: DMX, Blue Level,
Green Level, Red Level, Test Colors, Auto Sequence,
Run Program, and Slave Mode.
DMX OPERATION
Use the d - - - menu to set the starting address of the
unit. You can set the starting address of the unit with
the UP and DOWN buttons.
The fixture uses three channels with allocations as
follows:
CHANNEL 1: 0 - 255 Red level (255 = Maximum)
CHANNEL 2: 0 - 255 Green level (255 = Maximum)
CHANNEL 3: 0 - 255 Blue level (255 = Maximum)
MANUAL OPERATION
For manual operation the red, green, and blue LED
intensity levels may be independently controlled. Use
the Cb - -, Cg - -, and Cr - -, menus to set the
levels. The range is from 00 (OFF) to 30 (Full On).
TEST COLORS
The Test Colors option runs all LEDs at the level
selected in its menu. Use the E - - - menu to set the
level. The range is from 000 to 255. 255 is maximum.
AUTO SEQUENCE
The AUTO SEQUENCE mode switches continuously
through a sequence of all the preset programs . See
the RUN PROGRAM menu for more details. Use the
Au - - menu to set the sequence speed and activate
the option. The range is from 00 to 99. 99 is fastest.
RUN PROGRAM
The unit can operate using 55 preset programs. Preset
0 is "all off". Presets 1 through 7 are solid colors. The
remaining presets are a variety of changing patterns.
Use the Pr - - menu to select and activate a preset
program. The range is from 00 to 55.
MASTER/SLAVE OPERATION
The FXLD348R3I can operate in a Master/Slave mode
where one of the units can synchronize other units of
the same model.
Connect the units together using the DMX IN and
DMX OUT connectors. Set the unit to be the Master
in one of the modes above. Use the SLAV menu to set
a unit as a slave.
www.lightronics.com
Lightronics Inc. 509 Central Drive Virginia Beach, Va 234354 757 486 3588
Page 3 of 5
FXLD348R3I LED FIXTURE
Version 0.1 OWNERS MANUAL 02/16/2012
MAINTENANCE AND REPAIR
TROUBLESHOOTING
Check that you have power applied to the unit.
Check the fuse.
Check the DMX control cable.
Check the address settings of the unit and the
controller.
REPAIR
CAUTION DO NOT OPEN UNIT
RISK OF ELECTRIC SHOCK
RISK OF FIRE
The FXLD348R3I does not contain any user
serviceable parts.
Internal service on the unit by other than Lightronics
authorized agents will void the warranty. If service is
required, contact the dealer from whom you purchased
the item, or contact the Lightronics, Service
Department, 509 Central Drive, Virginia Beach, VA
23454. Tel: 757 486 3588.
PHOTOMETRIC CHARACTERISTICS
Distance Illuminance Beam Diam.
(ft) (Lux) (ft)
6.5 7800 3
20 620 10
30 290 15
www.lightronics.com
Lightronics Inc. 509 Central Drive Virginia Beach, Va 234354 757 486 3588
Page 4 of 5
FXLD348R3I LED FIXTURE
Version 0.1 OWNERS MANUAL 02/16/2012
MENU NAVIGATION
www.lightronics.com
Lightronics Inc. 509 Central Drive Virginia Beach, Va 234354 757 486 3588
Y
This product is warranted for a period of TWO YEARS from the date of purchase against
defects in materials and workmanship.
This warranty is subject to the following restrictions and conditions:
A) If service is required, you may be asked to provide proof of purchase from an authorized
Lightronics dealer.
B) This warranty is valid only for the original purchaser of the unit.
C) This warranty does not apply to damage resulting from abuse, misuse, accidents, shipping,
and repairs or modifications by anyone other than an authorized Lightronics service
representative.
D) This warranty is void if the serial number is removed, altered or defaced.
E) This warranty does not cover loss or damage, direct or indirect arising from the use or
inability to use this product.
F) Lightronics reserves the right to make any changes, modifications, or updates as deemed
appropriate by Lightronics to products returned for service. Such changes may be made
without prior notification to the user and without incurring any responsibility or liability for
modifications or changes to equipment previously supplied. Lightronics is not responsible
for supplying new equipment in accordance with any earlier specifications.
G) This warranty is the only warranty either expressed, implied, or statutory, upon which the
equipment is purchased. No representatives, dealers or any of their agents are authorized
to make any warranties, guarantees, or representations other than expressly stated herein.
H) This warranty does not cover the cost of shipping products to or from Lightronics for
service.
I) Lightronics Inc. reserves the right to make changes as deemed necessary to this warranty
without prior notification.
WARRANT
Lightronics Inc. 509 Central Drive Virginia Beach, VA 23454 20100211
www.lightronics.com
Lightronics Inc. 509 Central Drive Virginia Beach, Va 234354 757 486 3588