Lightolier XA Series User Manual

Lens Recessed XP/XA Series
Page 1 of 2 Static, 2' x 2', Recessed Fluorescent, Flat Steel Lens Frame (XP)
Regressed Aluminum Lens Frame (XA), 2 Lamp TT5
Features
Efficiency 84.1% (TT5 lamps)
• One piece housing
• Only 3-1/2" nominal deep body
• Flat steel full-size lens frame
• Regressed extruded aluminum lens frame
• Cam-action latches
• UL-Listed twin knockout access plate for easy closed lens frame wiring
Mounting Methods Dimensions
XP
Exposed T-grid ceiling.
Acoustical material
by others
XA
Exposed T-grid ceiling.
Acoustical material
by others
3-1/2"
(89mm)
24" (610mm)
24"
15/16" Exposed T-bar byothers
Flat steel lens frame Regressed aluminum lens frame
24"
15/16" Exposed T-bar by others
3-14""
(83mm)
24"
(610mm)
24" (610mm)
Job Information Type:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier is a Philips group brand
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group
Section 1A/Folio F60-55 Rev. A
03/08
Lens Recessed XP/XA Series
Page 2 of 2 Static, 2' x 2', Recessed Fluorescent, Flat Steel Lens Frame (XP)
Regressed Aluminum Lens Frame (XA), 2 Lamp TT5
Photometry Model No. XP2GVA2FT120SB
G03129 XP2GVA2FT120SB
THIS REPORTIS BASED ONPUBLISHED INDUSTRYPROCEDURES • FIELDPERFORMANCE MAY VARYFROM LABORATORY PERFORMANCE.
LER = FL - 74.3 IW - 58 BF - 0.87 Comparative yearly lighting energy cost per 1000 lumens = $3.24
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 92 85 89 83 81 78 80 78 76 2 85 78 73 74 70 66 71 68 65 3 78 69 63 66 61 56 63 59 55 4 72 62 55 59 53 49 57 52 48 5 66 56 49 53 47 43 52 46 42 6 61 51 43 48 42 38 47 42 37 7 57 46 39 44 38 34 43 37 33
room cavity ratio
8 53 42 35 40 34 30 39 34 30 9 50 39 32 37 31 27 36 31 27
10 47 36 29 35 29 25 34 29 25
visual comfort probability (rated lumens per lamp 2850.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 53 57 65 74 51 55 62 70
20 30 46 50 54 62 43 47 52 59 20 40 43 45 49 54 39 42 46 51 20 60 40 42 45 49 35 38 41 45
30 20 55 58 64 71 53 57 62 69 30 30 47 50 54 60 45 48 52 57 30 40 43 45 48 52 39 42 46 50 30 60 39 42 43 47 35 38 40 44 30 80 38 40 41 44 34 36 37 40
40 20 56 60 65 71 55 59 64 69 40 30 49 52 55 59 46 50 53 57 40 40 44 45 49 52 41 44 47 50 40 60 40 42 44 47 36 39 40 44 40 80 38 40 40 43 34 36 37 40 40 100 38 39 39 41 34 35 35 38
60 30 49 53 55 60 48 52 54 58 60 40 45 47 49 52 42 45 48 51 60 60 40 43 44 47 37 40 41 44 60 80 38 40 40 43 35 37 37 40 60 100 38 39 38 41 34 35 35 37
100 40 47 50 51 55 46 48 50 54 100 60 43 45 45 49 41 43 43 47 100 80 41 42 42 44 38 39 39 42 100 100 39 40 39 42 36 37 36 38
luminaries lengthwise
luminaries crosswise
Ordering Information
Explanation of Catalog Number. Example: XP2GVA2FT120SBGLR
G2 FTVA 2
XP = Recessed
Fluorescent with Flat Steel Lens Frame
XA = Recessed
Fluorescent with Regressed Aluminum Lens Frame
Options/Accessories
Special Lens: Substitute VY for .125" nominal pattern 12 with 7.8 oz. average weight per
square foot. Substitute VI for .125" normal pattern 12 with 6.8 oz. average weight per square foot. Access Plates: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP CSP.
Electrical Wiring Options: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture: Suffix: R. One per ballast: Suffix: B. Drywall Kit: G type fixtures for drywall or plaster ceilings. Order Catalog Number: FK92X2.
Specifications
Performance: In an installation of 2 lamps 40 W luminaires in a room cavity ratio of 1,
with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .89. To reduce glare the VCP shall not be less than 37 either lengthwise or crosswise (at 100 fc level) and the average brightness at 65 shall not exceed 3956 footlamberts. To control veil­ing reflections, luminaire output in the 30°-90° zone shall be not less than 68%.
Fixture Width Ceiling Type:
G = Grid (lay-in)
T-bar
Internal slow-blow fusing. Suffix: GMF.
Lens Shielding
Type:
VA = Virgin Acrylic
(standard) see options and consult factory
Lamp
Quantity:
(By others)
2 = 2 Lamp
-
Lamp Fixture Length:
FT = Twin Tube (T5)
(Nominal 24")
Specifications (continued)
Materials: Chassis parts are die-formed code gauge cold rolled steel. Lens frames (XP) flat full-size steel frame, (XA) regressed full-size aluminum frame. Finish: Chassis exterior—white baked polyester enamel. Cavity—white baked polyester
enamel minimum 86% reflectance. Phosphate undercoating. Lens: Extruded virgin acrylic 3/16" square based female cones, running 45° to the panel edge. .095" nominal thickness (similar to pattern 12). Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with­in 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
1-2 Lamp Elec. (TT5) SB* IB* LOL TT5 Dimming PB
*Instant Start Standard Other dimming options. Consult factory.
<20THD <10THD
Options:
Lamps Flex Fuse
(Consult your
representative)
Section 1A/Folio F60-55 Rev. A
Lightolier is a Philips group brand