Lightolier XA, XP User Manual

Lens Recessed XP/XA Series
Page 1 of 2 Static, 2' x 2', Recessed Fluorescent, Flat Steel Lens Frame (XP)
Regressed Aluminum Lens Frame (XA), 2 Lamp T8 or T12
Features
Efficiency 71.7% (T8 lamps)
• One piece housing
• Only 3-1/2" nominal deep body
• Flat steel full-size lens frame
• Regressed extruded aluminum lens frame
• Cam-action latches
• UL-Listed twin knockout access plate for easy closed lens frame wiring
Mounting Methods Dimensions
XP
Exposed T-grid ceiling.
Acoustical material
by others
XA
Exposed T-grid ceiling.
Acoustical material
by others
3-1/2"
(89mm)
24" (610mm)
24"
15/16" Exposed T-bar byothers
Flat steel lens frame Regressed aluminum lens frame
24"
15/16" Exposed T-bar by others
3-14""
(83mm)
24"
(610mm)
24" (610mm)
Job Information Type:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier is a Philips group brand
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group
Section 1A/Folio F60-50 Rev. A
03/08
Lens Recessed XP/XA Series
Page 2 of 2 Static, 2' x 2', Recessed Fluorescent, Flat Steel Lens Frame (XP)
Regressed Aluminum Lens Frame (XA), 2 Lamp T8 or T12
Photometry Model No. XP2GVA26U120SO
G2004002 XP2GVA26U120SO
LER = FL - 62.3 IW - 55.3 BF - 0.87 Comparative yearly lighting energy cost per 1000 lumens = $3.85
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 79 76 73 71 69 67 68 67 65 2 72 67 62 63 60 57 61 58 55 3 66 59 54 56 52 48 54 51 48 4 61 53 47 50 46 42 49 45 41 5 56 48 42 45 40 37 44 40 36 6 52 43 37 41 36 32 40 36 32 7 49 39 33 38 33 29 37 32 29
room cavity ratio
8 45 36 30 35 30 26 34 29 26 9 42 33 27 32 27 23 31 27 23
10 40 31 25 30 25 21 29 24 21
visual comfort probability (rated lumens per lamp 2850.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 62 66 72 80 59 63 69 77
20 30 56 59 63 70 52 56 60 66 20 40 53 55 59 63 48 51 55 60 20 60 50 52 54 58 45 48 50 54
30 20 63 67 72 78 61 65 69 76 30 30 56 59 63 68 53 57 60 65 30 40 53 55 57 61 49 51 54 58 30 60 50 52 53 56 45 47 49 52 30 80 49 50 50 53 44 46 46 49
40 20 65 68 73 77 64 67 71 76 40 30 58 61 64 67 55 59 61 65 40 40 53 56 58 60 50 53 55 58 40 60 50 52 53 55 46 48 49 52 40 80 49 50 50 532 45 46 46 49 40 100 49 50 49 50 45 45 44 46
60 30 59 62 64 68 57 60 63 66 60 40 54 56 58 61 52 54 56 59 60 60 51 52 53 55 47 49 50 53 60 80 49 50 50 52 45 46 46 49 60 100 49 49 48 50 45 45 44 46
100 40 57 59 60 63 55 57 59 62 100 60 53 54 54 57 51 52 52 55 100 80 52 52 51 53 49 49 48 50 100 100 51 51 49 51 48 47 46 47
luminaries lengthwise
luminaries crosswise
Ordering Information
Explanation of Catalog Number. Example: XP2GVA26U120SOGLR
G2 6UVA 2
XP = Recessed
Fluorescent with Flat Steel Lens Frame
XA = Recessed
Fluorescent with Regressed Aluminum Lens Frame
Options/Accessories
Special Lens: Substitute VY for .125" nominal pattern 12 with 7.8 oz. average weight per
square foot. Substitute VI for .125" normal pattern 12 with 6.8 oz. average weight per square foot. Access Plates: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP CSP.
Electrical Wiring Options: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture: Suffix: R. One per ballast: Suffix: B. Drywall Kit: G type fixtures for drywall or plaster ceilings. Order Catalog Number: FK92X2.
Specifications
Performance: In an installation of 2 lamps 32 W luminaires in a room cavity ratio of 1,
with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .76. To reduce glare the VCP shall not be less than 47 either lengthwise or crosswise (at 100 fc level) and the average brightness at 65 shall not exceed 2775 footlamberts. To control veil­ing reflections, luminaire output in the 30°-90° zone shall be not less than 67.7%.
Fixture Width Ceiling Type:
G = Grid (lay-in)
T-bar
Lens Shielding
Type:
VA = Virgin Acrylic
(standard) see options and consult factory
Lamp
Quantity:
(By others)
2 = 2 Lamp
-
Lamp Fixture Length:
6U = 6", U Lamp
T8 or T12
Specifications (continued)
Materials: Chassis parts are die-formed code gauge cold rolled steel. Lens frames—(XP) flat full-size steel frame, (XA) regressed full-size aluminum frame. Finish: Chassis exterior—white baked polyester enamel. Cavity—white baked polyester enamel minimum
86% reflectance. Phosphate undercoating. Lens: Extruded virgin acrylic 3/16" square based female cones, running 45° to the panel edge. .095" nominal thickness (similar to pattern 12). Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group
Voltage:
120, 277 or
UNV=120-277
1-2 Lamp Magnetic (T12) LE
1-2 Lamp Elec. (T8) SO* HI* LOL T8 Dimming PS
*Instant Start Standard Other dimming options. Consult factory.
Ballast Type:
<20THD <10THD
Options:
Lamps Flex EM Pack Fuse
(Consult your
representative)
Section 1A/Folio F60-50 Rev. A