Lightolier WLRN244120SB User Manual

Wal-Lyter WLRN244120SB
Page 1 of 2 High Performance, 4', Recessed Wallwasher/Accent Light
Two Twin-Tube T5 Lamps
Features
• Low iridescent specular reflective system for precise controlled light output.
• Evenly lights vertical surfaces or displays.
• 87% energy savings vs. incandescent.
• 20,000 hours lamp life requires less maintenance than incandescent.
• Fits all lay-in grid ceiling systems.
• One-piece body and adjustable integral hanger for easy, quick installation.
• UL-Listed access plate.
• Meets NYC Code requirements.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K10-12 Rev. A
9/05
narrow grid. slot grid
standard grid
1-1/2"
1-3/16"
Features Dimensions
1-1/2"
Mounting Methods
Ballast
Wall
4 low iridescent specular
aluminum reflectors
20,000 hour Biax type lamp (22-1/2" long)
23-3/8"6"
17-5/8"
2" x 3" access plate
2-7/8"
22-1/16"
opening
adjustable integral hanger
0' 1' 2' 3' 4' 5' 6' 7' 8' 0
Ceiling
8' 111. 101. 75.5 47.8 28.3 18.1 13.2 10.4 0.87 124. 119. 104. 95.4 104. 119. 124. 7' 113. 104. 81.7 55.7 35.5 23.5 16.6 12.5 09.8 130. 127. 117. 111. 117. 127. 130. 6' 86.4 81.0 66.9 49.8 34.8 24.6 17.7 13.4 10.4 104. 106. 102. 100. 102. 106. 104. 5' 62.5 59.1 51.4 41.6 31.9 24.3 18.4 13.9 16.7 81.1 83.5 83.2 83.2 83.2 83.4 81.1 4' 50.5 48.6 42.9 35.6 28.7 22.6 18.0 14.3 11.1 68.8 71.3 71.6 71.3 71.6 71.3 68.8 3' 39.7 38.5 34.9 30.0 25.1 20.6 16.9 14.1 11.4 56.8 59.2 60.0 59.9 60.0 59.2 56.8 2' 31.1 30.3 28.1 25.0 21.7 18.5 15.7 13.4 11.1 47.0 48.8 49.7 50.0 49.7 48.8 47.0 1' 24.2 23.6 22.5 20.8 18.7 16.5 14.6 12.8 11.0 38.8 40.2 41.1 41.5 41.1 40.2 38.8
Floor
INDIVIDUAL WAL-LYTER
MULTIPLE UNITS
Wal-Lyter WLRN244120SB
Page 2 of 2 High Performance, 4', Recessed Wallwasher/Accent Light
Two Twin Tube T5 Lamps
Lightolier a Genlyte Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section5/Folio K10-12 Rev. A
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: WLRN244120SBGLR
Options/Accessories
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF. Lens: .187, pattern 19 lens. Catalog Number: WLRKIT-4 CSP to be field installed. Radio Interference Filter: To order one RIF per fixture, Suffix: R. To order one RIF per ballast, Suffix: B. Electrical/Wiring Options: Consult factory. Fluorescent Emergency Lighting System: Factory-installed emergency power battery pack with charger and inverter. Suffix: EM. Drywall Frame: Catalog Number: WL4DF/UNV.
Specifications
Materials: Chassis parts are die-formed 20 gauge cold rolled steel with
integral adjustable hanger clamp.
Reflectors–low iridescent specular aluminum are standard. Finish: Chassis exterior–phosphate undercoating, baked white acrylic enamel. Reflector–low iridescent specular is standard.
Lens: Virgin acrylic .187 pattern 19 with square based male conical prisms (rotates for easy lamp replacement).
Electrical: Rapid start HPF, thermally protected class “P” ballast (Biax type). If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry
Model No. WLRN244120SB
WL
Wal-Lyter:
Low iridescent
specular
wallwash
R
Recessed
Reflector:
N= Low iridescent
specular aluminum standard
K = Pattern 19 virgin
acrylic lens installed at factory
2
Lamps
4
Length:
4=48"
Watts:
1=18 Watts 2=24 Watts 4=40 Watts 5=50 Watts 6=55 Watts
Voltage:
120 or 277
Options:
Add appropriate suffix to catalog
no, ie: (GLR)
LER = FP - 47.5 IW - 85 BF - 0.95 Comparative yearly lighting energy cost per 1000 lumens = $5.05
coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
1737067 656361 636159 2666156 575350 555249 3605347 504542 484441 4554740 443935 423835 5504134 393329 373329 6463630 342925 332825 7423226 312521 302521 8382922 272218 262118 9352519 241915 231915
10 32 23 17 22 17 13 21 16 13
room cavity ratio
FOOTCANDLES ON WALL Fixtures 3 feet from wall to outside trim on lamp side of fixture
6'
0' 1' 2' 3' 4' 5' 6' 7' 8'
0Ceiling
8' 120. 111. 88.6 65.7 56.5 65.8 88.6 111. 120. 181. 182. 183. 183. 184. 183. 183. 182, 181. 7' 124. 117. 98.4 79.0 70.9 79.1 98.4 117. 124. 200. 201. 203. 203. 203. 203. 203. 201. 200. 6' 97.7 94.8 84.7 74.4 69.6 74.4 84.7 94.8 97.7 173. 175. 176. 177. 177. 177. 176. 175, 173. 5' 74.1 73.5 69.9 66.0 63.8 66.0 69.9 73.5 74.1 143. 146. 147. 148. 148. 148. 147. 146. 143. 4' 62.6 63.4 61.2 58.3 57.3 58.3 61.1 63.4 62.6 125. 128. 129. 130. 130. 130. 129. 128. 125. 3' 51.9 53.0 52.1 50.6 50.2 50.6 52.0 53.1 51.9 108. 110. 111. 112. 113. 112. 111. 110. 108. 2' 43.0 44.1 43.9 43.4 43.2 43.4 43.9 44.0 43.0 91.9 03.0 05.2 05.9 96.3 95.9 95.2 93.9 91.9 1' 35.7 36.6 37.0 37.2 37.2 37.2 37.0 36.6 35.7 78.7 80.3 81.4 82.1 82.5 82.0 81.4 80.3 78.7
Floor
MULTIPLE UNITS
CONTINUOUS ROW
8'
Ballast Type:
<
20THD <10THD
2 Lamp Magnetic (TT5) BX*
(40 Watt)
2 Lamp Electronic (TT5) BA*
(18 Watt)
2 Lamp Electronic (TT5) BB*
(24 Watt)
2 Lamp Electronic (TT5) SB*
IB*
(40 Watt)
2 Lamp Electronic (TT5) BE* BP
(50 Watt)
2 Lamp Electronic (TT5) –* BF
(55 Watt)
LOL (TT5) Dimming PB**
(40 Watt)
*Instant Start Standard
optional drywall frame WL4DF/UNV.
Loading...