Lightolier VTS2GPK3FT User Manual

VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT
Page 1 of 2 2'x2' RECESSED FLUORESCENT
MOUNTING METHODS DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 5/Folio K05-10
Features
• Provides soft vertical illumination for comfortable televising of participants.
• Shields the camera from light sources and eliminates glare on the projection screen.
• Integrated specular parabolic blades and prismatic acrylic lens assembly for directional brightness control.
• 77 minimum VCP in rooms with less than 10' ceiling (3 lamp TT5).
• Spring-loaded latches.
• Concealed “T” hinges.
• Louver/lens assembly with positive light stop.
• Four earthquake clips standard.
• UL-Listed twin knockout access plate.
• Construction to meet NYC Code Requirements and Chicago Plenum Code is available.
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
1/4" max.
1-1/2" max.
1-7/8" max.
24"
24"
15/16"
or 1"
9/16"
6" (152mm)
24" (610mm)
23-7/8"
(606mm)
15-11/16"
(398mm)
5"
(127mm)
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
TELECONFERENCE LIGHTING RECOMMENDATIONS
1. I.E.S. recommends 50 maintained footcandles for teleconferencing.
2. 3000K lamps with C.R.I. of 82 suggested for better skin tone.
3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpen­dicular to the wall that the viewing screen is on.
4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram).
5. Side and back walls should be illuminated to reduce contrast vs. other vertical sur­faces. Use wall lighting luminaires where necessary. 5:1 maximum luminance ratio suggested.
NOTE: For wall lighting, request Folio K20-05.
6'
Lamp Direction
End of Fixture
Viewing Screen
TELECONFERENCING ORIENTATION
VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT
Page 2 of 2 2'x2' RECESSED FLUORESCENT
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 5/Folio K05-10
Job Information Type:
OPTIONS & ACCESSORIES
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory. DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10). CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Parabolic Blades–pre-anodized specular aluminum (Coilzak® or equal). Lens–High quality glare control lens with square based male conical prisms. FINISH: Chassis exterior–black baked polyester enamel. Cavity–white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc listed.
PHOTOMETRY MODEL NO. VTS2GPK3FT120X3
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1626059 575554 555453 2585552 525048 504947 3545047 484543 464442 4514642 444139 434038 5484238 403735 393734 6453935 373431 363331 7423632 353129 343129 8393329 322926 312826 9373127 302724 292624
10 35 29 25 28 25 22 27 24 22
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 94 92 89 81 82 77 76 75
20 30 95 93 92 85 84 78 72 70 20 40 96 93 92 87 86 80 73 69 20 60 96 94 93 85 87 82 76 70
30 20 94 91 89 81 82 79 80 76 30 30 95 92 91 85 86 80 75 71 30 40 95 93 91 85 88 83 76 69 30 60 95 93 93 85 89 84 79 70 30 80 95 94 93 85 89 86 81 70
40 20 94 92 90 81 83 79 80 79 40 30 95 92 92 85 86 80 77 74 40 40 96 93 92 85 99 93 78 72 40 60 96 94 93 85 89 85 80 73 40 80 95 94 93 85 90 86 82 73 40 100 95 94 94 85 90 87 84 73
60 30 95 93 92 85 86 80 77 74 60 40 96 93 92 86 88 83 78 72 60 60 96 94 93 86 90 85 81 74 60 80 95 94 93 86 90 87 83 75 60 100 95 94 94 86 90 88 85 75
100 40 96 93 92 87 88 83 78 73 100 60 96 94 92 87 90 86 81 74 100 80 95 94 93 87 91 88 84 75 100 100 95 94 94 87 91 89 85 76
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VTS2GPK3FT120X3GLR
Other dimming options. Consult factory.
LER = FP - 42.9 WATTS - 102.6 BF - 0.85 Comparative yearly lighting energy cost per 1000 lumens = $5.59
VT
VT:
Video
Teleconference
Luminaire
S
BODY STYLE:
S=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
T= Slot Grid
PK
INTEGRATED
SHIELDING
LAMP
QUANTITY
2=2 Lamp 3=3 Lamp
LAMP TYPE/
FIXTURE LENGTH:
6U=6"U Lamp T8
(2 Lamp Only)
FT=
Twin Tube T5
(Nominal 24")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix to catalog
no, ie: (GLR)
BALLAST TYPE:
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I*
1 & 2 Lamp Elec. TT5 SB*
IB*
(40 watt) 1-3 Lamp Elec. T8 O3* H3* 1-3 Lamp Elec. TT5 X3*
I3*
(40 watt) LOL T8 Dimming PS LOL TT5 Dimming PB
*Instant Start Standard
Blank=Standard N=NYC Code
G02032 VTS2GPK3FT120X3
Loading...