Lightolier VTS2GPK332 User Manual

VIDEO TELECONFERENCE LUMINAIRE VTS2GPK332
Page 1 of 2 2'x4' RECESSED FLUORESCENT
MOUNTING METHODS DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 5/Folio K05-15
Features
• Provides soft vertical illumination for comfortable televising of par­ticipants.
• Shields the camera from light sources and eliminates glare on the projection screen.
• Integrated specular parabolic blades and prismatic acrylic lens assembly for directional brightness control.
• 86 minimum VCP in rooms with less than 10' ceiling (3 lamp T8).
• Spring-loaded latches.
• Concealed “T” hinges.
• Louver/lens assembly with positive light stop.
• Four earthquake clips standard.
• UL-Listed twin knockout access plate.
• Construction to meet NYC Code Requirements and Chicago Plenum Code is available.
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
1/4" max.
1-1/2" max.
1-7/8" max.
24"
24"
15/16"
or 1"
9/16"
6" (152mm)
24" (610mm)
6" (152mm)
39-1/4" (997mm)
47-31/32" (1218mm)
2" x 2-1/2" access plate with two K.O.s (7/8" dia.)
TELECONFERENCE LIGHTING RECOMMENDATIONS
1. I.E.S. recommends 50 maintained footcandles for telecon­ferencing.
2. 3000K lamps with C.R.I. of 82 suggested for better skin tone.
3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpendicular to the wall that the viewing screen is on.
4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram).
5. Side and back walls should be illuminated to reduce contrast vs. other vertical surfaces. Use wall lighting luminaires where nec­essary. 5:1 maximum luminance ratio suggested.
NOTE: For wall lighting, request Folio K20-05.
6' Min.
Lamp Direction
End of Fixture
Viewing Screen
TELECONFERENCING ORIENTATION
VIDEO TELECONFERENCE LUMINAIRE VTS2GPK332
Page 2 of 2 2'x4' RECESSED FLUORESCENT
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 5/Folio K05-15
Job Information Type:
OPTIONS & ACCESSORIES
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory. DRYWALL KIT: Order Catalog Number: FK92X4. (Request Folio OA30-10). CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Parabolic Blades–pre-anodized specular aluminum (Coilzak® or equal). Lens–High quality glare control lens with square based male conical prisms. FINISH: Chassis exterior–black baked polyester enamel. Cavity–white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc listed.
PHOTOMETRY MODEL NO. VTS2GPK332120O3
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1676563 616059 595857 2635956 565452 545251 3585450 514846 504745 4554945 474441 464340 5514540 433937 423936 6484137 403633 393533 7453833 373330 363230 8423531 343027 333027 9393228 312825 312725
10 37 30 26 29 26 23 29 25 23
visual comfort probability (rated lumens per lamp 2850.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 97 96 96 92 90 86 85 84
20 30 97 96 96 92 91 87 83 81 20 40 97 96 96 92 91 88 84 80 20 60 97 96 96 93 91 88 86 82
30 20 97 96 96 92 90 86 88 85 30 30 97 96 96 92 91 87 86 82 30 40 98 96 96 93 91 88 86 81 30 60 98 96 96 93 91 88 88 82 30 80 97 96 96 93 91 88 88 82
40 20 97 96 96 92 90 87 88 88 40 30 98 96 96 93 91 87 87 84 40 40 98 97 96 93 91 88 87 83 40 60 97 97 97 93 91 88 88 84 40 80 97 97 97 93 91 88 88 84 40 100 98 97 97 93 91 88 88 84
60 30 98 97 97 93 91 87 87 84 60 40 97 97 97 93 91 88 87 83 60 60 97 97 97 93 91 88 88 84 60 80 97 97 97 93 91 88 88 84 60 100 98 97 97 93 91 88 88 84
100 40 97 97 97 93 91 88 87 83 100 60 97 97 97 94 91 88 88 84 100 80 97 97 97 94 91 88 88 84 100 100 97 97 97 94 91 89 88 84
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VTS2GPK332120O3GLR
Other dimming options consult factory.
LER = FP - 54.6 IW - 83.5 BF - 0.89 Comparative yearly lighting energy cost per 1000 lumens = $4.39
VT
VT:
Video
Teleconference
Luminaire
S
BODY STYLE:
S=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
T= Slot Grid
Blank=Standard N=NYC Code
PK
INTEGRATED
SHIELDING
LAMP
QUANTITY:
2=2 Lamp 3=3 Lamp 4=4 Lamp
LAMP TYPE/
FIXTURE LENGTH:
32=T8
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix to catalog
no, ie: (GLR)
BALLAST TYPE:
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I*
1-3 Lamp Elec. T8 O3* H3* 1-4 Lamp Elec. T8 O4* H4*
LOL T8 Dimming PS *Instant Start Standard
VTS2GPK332120O3
Loading...