Lightolier VRA2G9LS26USO User Manual

VR PARABOLIC VRA2G9LS26U
Page 1 of 2 2'x2' RECESSED FLUORESCENT, 4" DEEP, 9 CELL (3x3) PARABOLIC LOUVER
AIR SUPPLY/RETURN/HEAT EXTRACTION, IES RP1 FOR NORMAL VDT USE
MOUNTING METHOD DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-40 REV. A
Features
• Meets IES RP1 for lighting VDT areas with normal use.
• 57.1% efficient (T8).
• 1.3 spacing mounting ratio.
• Only 6" deep body.
• One-piece housing.
• Semi-specular low iridescence pre-anodized louver.
• Spring-loaded latches.
• Concealed “T” hinges.
• Louver frame with integral positive light stop.
• Earthquake clips included.
• Louver has protective film dust guard.
• Air closure strips (optional).
• Air flow pattern dampers (optional).
• UL-Listed twin knockout access plate.
• Construction to meet Chicago Plenum Code is available.
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
concealed Z-spline ceiling.
F
plaster ceiling/flanged.
T
direct concealed two directional T-grid ceiling. (see options for splay trim).
drywall kit (see options).
1/4" max.
1-1/2" max.
1-7/8" max.
24"
24"
15/16"
or 1"
9/16"
Type “G” Fixture
Support (by others)
24-5/16"
Ceiling
Opening
Drywall (by others)
15/16"
1/4" max.
1-7/8" max.
24"
13/16"
24-11/16"
24-11/16"
1-1/8" min. 3-3/4" max.
1-1/8" min.
3-3/4" max.
6" (152mm)
5"
(127mm)
15-11/16"
(398mm)
23-31/32"
(608mm)
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
24" (610mm)
Air supply
slots
(VRA only)
VR PARABOLIC VRA2G9LS26U
Page 2 of 2 2'x2' RECESSED FLUORESCENT, 4" DEEP, 9 CELL (3x3) PARABOLIC LOUVER
AIR SUPPLY/RETURN/HEAT EXTRACTION, IES RP1 FOR NORMAL VDT USE
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-40 REV. A
Job Information Type:
OPTIONS & ACCESSORIES
PLASTER FRAME: Catalog Number: PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures, Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL WIRING OPTIONS: Consult factory. AIR CLOSURE STRIPS: SUFFIX ACS2 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10.) CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .62 with a spacing to mounting ratio of 1.3 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba­bility) shall not be less than 93 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 357, 130, and 38 cande­las per square meter respectively in the 0°, 45°, and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 1521.
SPECIFICATIONS (continued)
AIR HANDLING: (VRA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com­partment through fixture body ends.
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak@ or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked
polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflec­tor sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY
MODEL NO. VRA2G9LS26USO
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1646260 585756 565554 2595653 535149 514948 3555047 484543 474442 4514642 444038 424037 5484137 403633 393633 6443833 363330 353230 7423430 332927 322927 8383227 302724 302624 9362925 282422 282422
10 34 27 23 26 22 20 26 22 20
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 91 85 77 77 92 90 85 76 20 30 92 87 81 77 92 90 88 81 20 40 92 89 84 80 92 90 88 84 20 60 92 89 86 82 92 91 88 84
30 20 91 85 81 78 92 91 87 77 30 30 92 88 84 78 92 91 89 81 30 40 92 89 87 81 92 91 89 83 30 60 92 89 88 83 92 91 89 84 30 80 93 90 88 83 92 90 89 84
40 20 91 85 81 81 92 91 87 79 40 30 92 88 84 81 92 91 89 83 40 40 92 89 87 83 92 91 89 85 40 60 93 90 88 85 93 90 89 84 40 80 93 90 88 85 93 90 89 84 40 100 93 90 88 85 93 90 89 84
60 30 92 83 84 81 92 91 89 83 60 40 93 90 87 83 92 90 89 84 60 60 93 90 88 85 93 90 89 84 60 80 93 90 88 85 93 90 89 83 60 100 93 90 88 85 93 90 89 83
100 40 93 90 87 83 93 90 89 84 100 60 93 90 88 85 93 90 89 83 100 80 93 90 88 85 93 90 89 84 100 100 93 90 88 85 93 90 89 84
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VRA2G9LS26U120SOGLR
LER = FP - 47.8 IW - 59.2 BF - 93.6 Comparative yearly lighting energy cost per 1000 lumens = $5.02
VR
VR:
4" Deep
Pre-anodized
Aluminum
Louver
For Normal
VDT Use
BODY STYLE: A=Air Handling S=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
F=Flanged
(overlap)
Z spline and plaster frame
T=Slot grid or
two-directional concealed T (see options)
9
NUMBER OF
CELLS:
(3 rows of
3 cells)
LOUVER FINISH*:
L=Low
Iridescence Semi-specular (standard)
P=Low
Iridescence Specular
S
SINGLE “V” REFLECTOR
2
LAMP
QUANTITY
6U
LAMP TYPE/
FIXTURE LENGTH:
6"U LAMP
T8 OR T12
(Nominal 24")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix to catalog
no, ie: (GLR)
BALLAST TYPE:
1-2 Lamp Mag. T12 LE
<20THD <10THD
1-2 Lamp Elec. T8 SO* H
I*
LOL T8 Dimming PS – *Instant Start Standard
Other dimming options consult factory.