Lightolier VRA2G18LP332 User Manual

VR PARABOLIC VRA2G18LP332
Page 1 of 2 2'x4' RECESSED FLUORESCENT, 4" DEEP, 18 CELL (3x6) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
MOUNTING METHODS DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-64 REV. A
Features
• Meets IES RP1 for lighting VDT areas with normal use.
• 64.5% efficient (T8).
• 1.4 spacing mounting ratio.
• Only 6" deep body.
• One-piece housing.
• Semi-specular low iridescence pre-anodized louver.
• Spring-loaded latches.
• Concealed “T” hinges.
• Louver frame with integral positive light stop.
• Earthquake clips included.
• Louver has protective film dust guard.
• Air closure strips (optional).
• UL-Listed twin knockout access plate.
• Construction to meet Chicago Plenum Code is available.
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
concealed Z-spline ceiling.
F
plaster ceiling/flanged.
T
direct concealed two directional T-grid ceiling. (see options for splay trim).
drywall kit (see options).
1/4" max.
1-1/2" max.
1-7/8" max.
24"
24"
15/16"
or 1"
9/16"
Type “G” Fixture
Support (by others)
24-5/16"
Ceiling
Opening
Drywall (by others)
15/16"
1/4" max.
1-7/8" max.
24"
13/16"
24-11/16"
24-11/16"
1-1/8" min. 3-3/4" max.
1-1/8" min. 3-3/4" max.
6" (152mm)
3-1/2"
(89mm)
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
Air supply slots (VRA only)
39-1/4" (997mm)
47-31/32" (1218mm)
6" (152mm)
24" (610mm)
VR PARABOLIC VRA2G18LP332
Page 2 of 2 2'x4' RECESSED FLUORESCENT, 4" DEEP, 18 CELL (3x6) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-64 REV. A
Job Information Type:
OPTIONS & ACCESSORIES
PLASTER FRAME: Catalog Number: PF24. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures, Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ24 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL WIRING OPTIONS: Consult factory. AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X4. Request Folio OA30-10. CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 3 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .70 with a spacing to mounting ratio of 1.4 perpendicular to the lamps. To meet IES RP1 recommended (basic) requirements for VDT areas the VCP (visual comfort probability) shall not be less than 94 either crosswise or lengthwise and the maximum average brightness at 65°, 75° and 85° shall not exceed 304, 147, and 0 candelas per square meter respectively in the 0°, 45°, and 90° horizontal planes.
SPECIFICATIONS (continued)
AIR HANDLING: (VRA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com­partment through fixture body ends.
MATERIALS: Chassis parts are die-formed embossed cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak@ or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked
polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflec­tor sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY MODEL NO. VRA2G18LP332O3
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1727068 666563 646261 2676460 605856 585654 3635854 555249 535148 4585248 504644 494643 5544843 464239 454138 6514439 423835 413735 7474035 383431 383431 8443732 353128 353128 9423429 332926 322826
10 39 31 27 30 26 24 30 26 24
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 90 86 79 79 98 96 97 93 20 30 92 88 83 78 98 97 97 94 20 40 92 89 86 81 98 97 97 94 20 60 93 90 87 83 98 97 97 94
30 20 90 86 84 82 98 97 97 92 30 30 92 89 86 81 98 97 97 94 30 40 93 90 88 83 98 97 97 94 30 60 93 91 89 85 98 97 97 94 30 80 93 91 90 86 98 97 97 94
40 20 90 86 84 85 98 97 97 92 40 30 93 90 86 84 98 97 97 93 40 40 93 91 88 84 98 97 97 93 40 60 94 91 90 86 98 97 97 94 40 80 94 91 90 87 98 97 97 94 40 100 94 91 90 88 98 97 97 94
60 30 93 90 86 83 98 97 97 93 60 40 93 91 89 84 98 97 97 93 60 60 94 92 90 87 98 97 97 94 60 80 94 92 90 88 98 97 97 94 60 100 94 92 91 88 98 97 97 94
100 40 93 91 89 84 98 97 97 94 100 60 94 92 90 87 98 97 97 94 100 80 94 92 91 88 98 97 97 95 100 100 93 92 91 89 97 97 97 95
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VRA2G18LP332120SOGLR
LER = FP - 55.0 WATTS - 85 BF - 0.85 Comparative yearly lighting energy cost per 1000 lumens = $4.36
VR
VR:
4" Deep
Pre-anodized
Aluminum
Louver
For Normal
VDT Use
BODY STYLE: A=Air Handling S=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
F=Flanged
(overlap)
Z spline and plaster frame
T=Slot grid or
two-directional concealed T (see options)
18
NUMBER OF
CELLS:
(3 rows of
6 cells)
LOUVER FINISH*:
L=Low
Iridescence Semi-specular (standard)
P=Low
Iridescence Specular
P
DUAL “V”
REFLECTOR
3
LAMP
QUANTITY
LAMP TYPE/
FIXTURE LENGTH:
32=T8 34=T12
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix to catalog
no, ie: (GLR)
BALLAST TYPE:
1 & 2 Lamp Mag. LE
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I*
1-3 Lamp Elec. T8 O3* H3* LOL T8 Dimming PS
*Instant Start Standard
Other dimming options. Consult factory.