Lightolier VPA2G27PP332 User Manual

VP PARABOLIC VPA2G27PP332
Page 1 of 2 2'x4' RECESSED FLUORESCENT, 4" DEEP, 27 CELL (3x9) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)
MOUNTING METHODS DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-30 REV. A
Features
• Meets IES RP1 for lighting VDT areas with intense use.
• 66% efficient (T8).
• 1.5 spacing mounting ratio.
• Only 6" deep body.
• One-piece housing.
• Specular low iridescence pre-anodized louver.
• Spring-loaded latches.
• Concealed “T” hinges.
• Louver frame with integral positive light stop.
• Earthquake clips included.
• Louver has protective film dust guard.
• Air closure strips (optional).
• Air flow pattern dampers (optional).
• UL-Listed twin knockout access plate.
• Construction to meet Chicago Plenum Code is available.
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
concealed Z-spline ceiling.
F
plaster ceiling/flanged.
T
direct concealed two directional T-grid ceiling. (see options for splay trim).
drywall kit (see options).
1/4" max.
1-1/2" max.
1-7/8" max.
24"
24"
9/16"
15/16"
or 1"
Type “G” Fixture
Support (by others)
24-5/16"
Ceiling
Opening
Drywall (by others)
15/16"
1/4" max.
1-7/8" max.
24"
13/16"
24-11/16"
24-11/16"
1-1/8" min. 3-3/4" max.
1-1/8" min.
3-3/4" max.
6" (152mm)
Air supply slots (VPA only)
3-1/2"
(89mm)
39-1/4" (997mm)
47-31/32" (1218mm)
24" (610mm)
6" (152mm)
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
VP PARABOLIC VPA2G27PP332
Page 2 of 2 2'x4' RECESSED FLUORESCENT, 4" DEEP, 27 CELL (3x9) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-30 REV. A
Job Information Type:
OPTIONS & ACCESSORIES
PLASTER FRAME: Catalog Number: PF24. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ24 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory. AIR CLOSURE STRIPS: SUFFIX ACS4 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X4. Request Folio OA30-10. CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 3 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .72 with a spacing to mounting ratio of 1.5 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba­bility) shall not be less than 90 either crosswise or lengthwise and the maximum average brightness at 55°, 65°, 75° and 85° shall not exceed 745, 0, 0 and 0 can­delas per square meter respectively in the 0°, 45°, and 90° horizontal planes. AIR HANDLING: (VPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.
SPECIFICATIONS (continued)
MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing
side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak®or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence specular anodized vertical grain aluminum reflector sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY MODEL NO. VPA2G27PP332O3
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1747270 686765 666463 2706663 636058 615957 3656056 575452 565351 4615551 534946 514846 5575046 484542 474441 6534641 454138 444037 7504238 413734 403734 8473934 383431 373331 9443632 353128 343128
10 41 34 29 33 29 26 32 28 26
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 89 95 92 83 97 97 97 90 20 30 90 95 93 83 97 97 97 91 20 40 90 95 93 83 97 97 97 91 20 60 90 95 93 83 97 98 97 91
30 20 90 95 93 86 97 97 97 92 30 30 90 95 93 86 97 98 97 92 30 40 90 95 93 86 97 98 97 92 30 60 90 95 93 87 97 98 97 92 30 80 90 95 93 87 97 98 97 92
40 20 90 95 93 86 97 97 97 92 40 30 90 95 93 86 97 98 97 92 40 40 90 95 93 87 97 98 97 92 40 60 90 95 93 87 97 98 97 92 40 80 90 95 93 87 97 98 97 92 40 100 90 95 93 87 97 98 97 92
60 30 90 95 93 86 97 98 97 92 60 40 90 95 93 87 97 98 97 92 60 60 90 95 93 87 97 98 97 92 60 80 91 95 91 87 97 98 97 92 60 100 91 95 91 87 97 98 98 93
100 40 90 95 93 87 97 98 97 92 100 60 91 95 91 87 97 98 97 92 100 80 91 95 91 87 97 98 98 93 100 100 91 95 91 87 97 98 98 93
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VPA2G27PP332120O3GLR
LER = FP - 46.1 IW - 116.4 BF - 95.1 Comparative yearly lighting energy cost per 1000 lumens = $5.20
VP
VP:
4" Deep Pre-
anodized
Aluminum
Louver
For Intense
VDT Use
BODY STYLE: A=Air Handling S=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
F=Flanged
(overlap)
Z spline and plaster frame
T=Slot grid or
two-directional concealed T (see options)
27
NUMBER OF
CELLS:
(3 rows of
9 cells)
P
LOUVER
FINISH*:
P=Low
Iridescence Specular
P
DUAL “V”
REFLECTORS
3
LAMP
QUANTITY
LAMP TYPE/
FIXTURE LENGTH:
32=T8 34=T12
(Nominal 48")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix to catalog
no, ie: (GLR)
BALLAST TYPE:
1 & 2 Lamp Mag. T12 LE
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I*
1-3 Lamp Elec. T8 O3* H3* LOL T8 Dimming PS
*Instant Start Standard
Other dimming options consult factory.
Loading...