Lightolier VPA2G12PP317 User Manual

VP PARABOLIC VPA2G12PP317
Page 1 of 2 2'x2' RECESSED FLUORESCENT, 4" DEEP, 12 CELL (3x4) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)
MOUNTING METHODS DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-22 REV. A
Features
• Meets IES RP1 for lighting VDT areas with intense use.
• 62.1% efficient (T8).
• 1.4 spacing mounting ratio.
• Only 6" deep body.
• One-piece housing.
• Specular low iridescence pre-anodized louver.
• Spring-loaded latches.
• Concealed “T” hinges.
• Louver frame with integral positive light stop.
• Earthquake clips included.
• Louver has protective film dust guard.
• Air closure strips (optional).
• UL-Listed twin knockout access plate.
• Construction to meet Chicago Plenum Code is available.
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
concealed Z-spline ceiling.
F
plaster ceiling/flanged.
T
direct concealed two directional T-grid ceiling. (see options for splay trim).
drywall kit (see options).
1/4" max.
1-1/2" max.
1-7/8" max.
24"
24"
9/16"
15/16"
or 1"
Type “G” Fixture
Support (by others)
24-5/16"
Ceiling
Opening
Drywall (by others)
15/16"
1/4" max.
1-7/8" max.
24"
13/16"
24-11/16"
24-11/16"
1-1/8" min. 3-3/4" max.
1-1/8" min. 3-3/4" max.
Air supply slots (VPA only)
3-1/2”
(89mm)
15-11/16"
(398mm)
23-31/22"
(608mm)
6" (152mm)
2"x 2-1/2" access plate with two K.O.s (7/8" dia.)
5"
(127mm)
24" (610mm)
VP PARABOLIC VPA2G12PP317
Page 2 of 2 2'x2' RECESSED FLUORESCENT, 4" DEEP, 12 CELL (3x4) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G05-22 REV. A
Job Information Type:
OPTIONS & ACCESSORIES
PLASTER FRAME: Catalog Number: PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL WIRING OPTIONS: Consult factory. AIR CLOSURE STRIP: SUFFIX ACS2 (factory installed). DRYWALL KIT: Order Catalog Number: FK92X2.
(Request Folio OA30-10)
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 17W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .68 with a spacing to mounting ratio of 1.4 perpendicular to the lamps. To meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba­bility) shall not be less than 90 either crosswise or lengthwise and the maximum average brightness at 55°, 65°, 75° and 85° shall not exceed 637, 32, 13 and 0 candelas per square meter respectively in the 0°, 45°, and 90° horizontal planes.
SPECIFICATIONS (continued)
AIR HANDLING: (VPA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com­partment through fixture body ends.
MATERIALS: Chassis parts are die formed code gauge cold rolled steel. Housing side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak®or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked
polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence specular anodized vertical grain aluminum reflector sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY MODEL NO. VPA2G12PP317SO
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1706867 646362 626160 2666360 605856 585655 3625855 555351 545250 4595349 514846 504745 5554945 474441 464341 6514541 444037 433937 7484137 403634 393633 8443733 363330 363230 9413429 332926 322926
10 38 31 26 30 26 23 29 26 23
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 89 93 92 83 98 98 98 93
20 30 89 93 92 83 98 99 98 94 20 40 89 93 92 84 98 99 98 94 20 60 90 94 92 84 98 99 98 94
30 20 89 93 92 86 98 99 98 94 30 30 90 94 92 87 98 99 98 94 30 40 90 94 92 87 98 99 98 94 30 60 90 94 92 87 98 99 98 94 30 80 90 94 92 87 98 99 98 95
40 20 89 93 92 86 98 99 98 94 40 30 90 94 92 87 98 99 98 94 40 40 90 94 92 87 98 99 98 94 40 60 90 94 93 87 98 99 98 95 40 80 90 94 93 87 98 99 98 95 40 100 90 94 93 87 98 99 98 95
60 30 90 94 92 87 98 99 98 94 60 40 90 94 93 87 98 99 98 95 60 60 90 94 93 87 98 99 98 95 60 80 90 94 93 87 98 99 98 95 60 100 90 94 93 87 98 99 98 95
100 40 90 94 93 87 98 99 98 95 100 60 90 94 93 87 98 99 98 95 100 80 90 94 93 87 98 99 98 95 100 100 90 94 93 88 98 99 98 95
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FP - 49.0 IW - 47.0 BF - 0.90 Comparative yearly lighting energy cost per 1000 lumens = $4.89
VP
VP:
4" Deep
Pre-anodized
Aluminum
Louver
For Intense
VDT Use
BODY STYLE: A=Air Handling S=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
F=Flanged
(overlap)
Z spline and plaster frame
T=Slot grid or
two-directional concealed T (see options)
12
NUMBER OF
CELLS:
(3 rows of
4 cells)
P
LOUVER FINISH*:
P=Low
Iridescence Specular
P
DUAL “V”
REFLECTOR
3
LAMP
QUANTITY
17
LAMP TYPE/
FIXTURE LENGTH:
17=T8, 2' Lamp
(Nominal 24")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix to catalog
no, ie: (GLR)
BALLAST TYPE:
<20THD <10THD
1&2 Lamp Elec. T8 SO* H
I*
1-3 Lamp Elec. T8 O3* H3* LOL T8 Dimming PS
*Instant Start Standard
ORDERING INFORMATION Explanation of Catalog Number. Example: VPA2G12PP317120SOGLR
Other dimming options. Consult factory.
Loading...