Lightolier STA 1'x4' 2 LAMP, STA 1x4 Specification

STACKLYTE STA 1'x4' 2 LAMP
Page 1 of 2 1'x4' RECESSED FLUORESCENT, 3" DEEP, 8 OR 12 CELL PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
Features
• Excellent for lighting library bookshelves, 97.5% of fixtures distribu­tion is in the 0°-60° zone.
• Meets IES RP1 for lighting VDT areas with normal use.
• 68.4% efficient (T8 - 8 cell).
• Semi-specular low iridescence pre-anodized louver.
• Vertical grain on louver eliminates reflected lamp image on cross baffle.
• Louver frame with integral positive light stop.
• Spring loaded latches (self centering).
• Louver has protective dust guard.
• Black housing exterior for cooler ballast operating temperature.
• Turned-in edges for safe handling.
• Built-in earthquake clip.
• UL-Listed twin knockout access plate.
• Air closure strips (optional).
• Construction to meet NYC Code or Chicago Plenum is available.
MOUNTING METHODS DIMENSIONS
exposed T-grid ceiling.
G
12"
plaster ceiling/flanged.
F
Plaster Opening 12-1/8"
12-11/16"
1/4" max.
9/16" to 1"
Exposed T-bar by others
1-1/8" min 3-3/4" max.
13/16"
Aluminum flange trim
Acoustical material by others
Plaster frame must be ordered separately
Plaster by others
exposed slot T-grid ceiling.
T
12"
direct concealed two directional T-
T
grid ceiling.
12"
Exposed slot T-bar by others
9/16"
1/4" max.
1-7/8" max.
3/8"
1-1/2" max.
Acoustical material by others
Acoustical material by others
6-5/8"
(168mm)
Job Information Type:
Job Name:
Cat. No.:
12"
(305mm)
earthquake clip
before
installation
earthquake clip
installed
Lamp(s):
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902
Section 2/Folio G40-16 REV. A
STACKLYTE STA 1'x4' 2 LAMP
Page 2 of 2 1'x4' RECESSED FLUORESCENT, 3" DEEP, 8 OR 12 CELL PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902
Section 2/Folio G40-16 REV. A
Job Information Type:
OPTIONS & ACCESSORIES
ACCESS PLATE: Top Wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify sepa­rately. Order Catalog Number: ACP CSP.
ELECTRICAL WIRING OPTIONS: Consult factory. FUSING: Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 . PLASTER FRAMES: F type fixtures do not include plaster frames. For individual or continuous mounting, specify PF14 universal frame per fixture. AIR CLOSURE STRIPS: SUFFIX ACS4 (factory installed). DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10. CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: Luminaire distribution is to be a minimum of 97.5% in the 0°-
60° zone. In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80 with a spacing to mounting ratio of 1.6 perpendicular to the lamps. To meet IES RP1 recommended (basic) requirements for VDT areas the VCP (visual comfort probabili­ty) shall not be less than 90 either crosswise or lengthwise, and the maximum
SPECIFICATIONS (continued)
average brightness at 65°, 75° and 85° shall not exceed 617, 191 and 162 can­delas per square meter respectively in the 0°, 45° and 90° horizontal planes. AIR HANDLING: (STA only) side air passages for air supply or air return. Optional side closure strips. Air return is also provided through the lamp com­partment through fixture body ends.
MATERIALS: Chassis parts are die-formed embossed cold rolled steel. Housing is embossed for rigidity with all edges turned-in for safe handling. LOUVER: Pre-anodized aluminum (Coilzak® or equal). FINISH: Louver—semi-specular low iridescence pre-anodized reflector sheet. Reflector—95% reflective specular. Phosphate undercoating. Chassis exterior—black baked polyester enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY MODEL NO. STA1G8LR232120SO
coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1777472 706867 676665 2716764 646159 615957 3666156 585452 565351 4625550 534946 514845 5575045 484441 474340 6534640 444036 433936 7504237 403633 393532 8473833 373329 363229 9443530 343027 343027
10 41 33 28 32 27 24 31 27 24
room cavity ratio
ORDERING INFORMATION
Explanation of Catalog Number. Example: STA1G8LR232120SOGLR
To meet NYC Code requirements prefix catalog number with (N).
BLANK = Standard N = NYC Code
ST
STACKLYTE:
3" Deep
Precision
Contoured
Pre-
anodized
Aluminum
Louver
BODY STYLE:
A=Air Handling S=Static
1
FIXTURE
WIDTH
CEILING TYPE:
G= Grid (lay-in T bar) F=Flanged (overlap)
Z spline and plaster frame
T=Slot grid or
two-directional concealed T (see options)
NUMBER OF
CELLS:
8=1 row of
8 cells
12=1 row of
12 cells
LOUVER FINISH:
L=Low
Iridescence Semi-specular (standard)
P=Low iridescence
specular
R
REFLECTOR:
R=Specular
95% Reflective
2
LAMP
QUANTITY
LAMP/
FIXTURE LENGTH:
32=T8 34=T12
(Nominal 48")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix to catalog
no, ie: (GLR)
VERTICAL FOOTCANDLES ON BOOK SHELVES
Ceiling 1' 2' 3' 4'
1.00 84.9 85.1 85.2 85.0 84.8 85.0 85.1 85.1 84.9
2.00 64.5 63.9 64.1 64.2 64.3 64.2 64.1 63.8 64.5
3.00 50.1 50.2 50.1 50.1 50.2 50.1 50.1 50.2 50.1
4.00 41.3 41.2 41.3 41.3 41.3 41.3 41.3 41.2 41.2
5.00 36.8 36.7 36.8 36.7 36.7 36.7 36.8 36.7 36.8
6.00 32.1 32.1 32.1 32.1 32.1 32.1 32.1 32.1 32.1
7.00 28.9 28.9 28.9 28.9 28.9 28.9 28.9 28.9 28.9
8.00 27.5 27.5 27.5 27.5 27.4 27.5 27.5 27.5 27.5
9.00 25.9 25.8 25.8 25.8 25.8 25.8 25.8 25.8 25.9
10.00 23.9 23.8 23.8 23.8 23.8 23.8 23.8 23.8 23.8
11.00 21.1 21.1 21.1 21.1 21.1 21.1 21.1 21.1 21.1
12.00 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5
0' 1' 2' 3' 4'
Book shelf aisle width, 36"
Floor
LER = FL - 55.0 IW - 61.9 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $4.36
BALLAST TYPE:
1 Lamp Mag. T12 LE
<20THD <10THD
1 Lamp Elec. T8 SO* H
I*
LOL Dimming PS – *Instant Start Standard
Other dimming options. Consult factory.