Lightolier ST4WA232120SO, ST4WA254UNVPG, ST4WA232UNVHI Specification

Sealatron Enclosed Industrial Fluorescent STW Series
Page 1 of 2 Wet /Damp Locations, Rapid Start, Slimline/High Output
1 or 2 Lamp T5, T5HO, T8, T8HO or T12HO
Wet Location-Areas of high humidity, water vapor, rain, incidental water spray, or other non-corrosive or non-flammable liquid. (UL-Listed)
• NSF Certified for Non-Food Zone installation.
• IP67 rating.
• Acceptable for outdoor as well as indoor installations.
• One-piece impact resistant, non-conductive, non-corrosive housing, reinforced polyester fiberglass housing.
• Smooth exterior surface for easy cleaning.
• Lighting channel has high reflectance baked white enamel finish.
• Two gasketed threaded (1/2" trade size) wet location hubs installed on ends.
• High impact DRacrylic molded lens.
• Crepe pattern inner surface lens.
• Continuous, compressible, closed-cell neoprene gasket bonded to housing.
• ABS lock-tight plastic molded cam-action tension latches.
• K.O.’s provided throughout for easy access.
• Can be surface (wall/ceiling) or suspended mounted unless otherwise specified.
Mounting brackets available, order separately.
Mounting Methods Dimensions
virgin acrylic lens opens easily, hinges either side
cam action tension latches
Shallow Lens Version
(Standard)
Deep Lens Version for high ambient, or when 800mA lamps are operated on T12HO ballasts.
Job Information Type:
Job Name:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 05/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Cat. No.:
Lamp(s):
Volts/Ballast:
Section7/Folio Q20-32 REV. F
Sealatron Enclosed Industrial Fluorescent STW Series
Page 2 of 2 Wet /Damp Locations, Rapid Start, Slimline/High Output
1 or 2 Lamp T5, T5HO, T8, T8HO or T12HO
Model No. ST4WA232120SO
LER = FP - 79 IW - 54 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $3.04
Report Number: 20017 Catalog Number: ST4WA232120SO Lamps: F32T8 Luminaire: Sealatron, enclosed industrial with high impact DR acrylic lens for wet/damp locations. Ballast: Triad B232I120RH Report is based on 2850 Lumens per lamp.
Efficiency: 85.1% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.5
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 70 50
RW 70 50 30 70 50 30 50 30
01 88 82 78 84 80 76 75 71 02 79 70 64 76 68 61 64 58 03 70 60 53 68 58 52 56 48 04 65 54 45 61 52 44 48 41 05 58 47 39 56 46 38 42 36 06 55 42 34 53 40 34 39 32 07 51 38 29 48 36 29 34 28 08 46 34 27 45 34 27 32 26 09 44 32 25 41 30 23 28 23
10 40 28 22 40 28 22 27 20
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 5162. 5457. 5986. 55 4608. 5337. 6090. 65 3872. 5287. 6339. 75 3090. 5685. 6743. 85 2194. 5573. 6459.
0
CANDELA DISTRIBUTION
ZONAL LUMEN SUMMARY
0.0 45.0 90.0
0 1109 1109 1109
5 1102 1105 1104
15 1066 1096 1116
25 988 1063 1117
35 871 1007 1110
45 717 921 1065
55 528 796 973
65 336 661 867
75 174 552 739
85 53 369 511
95 19 199 323
105 15 112 190
115 7 56 83
125 3 28 39
135 2 13 23
145 4713
155 446
165 557
175 678
ZONE LUMENS % LAMP % FIXT
00-030 0905 15.9 18.7 00-040 1532 26.9 31.6 00-060 2923 51.3 60.3 00-090 4438 77.9 91.5
90-180 0412 7.2 008.5
00-180 4850 85.1 100.0
Model No. ST4WA254UNVPG
LER = FP - 62.7 IW - 110.7 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.83
Report Number: 26075 Catalog Number: ST4WA254UNVPG Lamps: (2) F54T5 HO Luminaire: Sealatron, enclosed industrial
with high impact DR acrylic lens for
wet/damp locations. Ballast: ICN-2S54-90C Report is based on 4400 Lumens per lamp.
Efficiency: 78.8% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.5
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 82 77 73 70 67 64 66 63 61 02 73 66 59 60 55 51 56 52 49 03 66 57 49 52 46 41 49 44 40 04 60 50 42 46 39 35 43 28 33 05 55 44 36 41 34 29 38 33 29 06 51 40 32 36 30 25 34 29 25 07 47 36 28 33 27 22 31 26 22 08 44 32 25 30 24 20 29 23 19 09 41 30 23 28 22 18 26 21 17
10 38 27 21 25 20 16 24 19 16
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 8406. 9317. 8990.
55 7591. 9086. 8836.
65 6234. 8819. 9246.
75 4808. 10613. 10659.
85 3284. 10864. 9351.
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1621 1621 1621
5 1605 1644 1605 155
15 1550 1632 1620 455
25 1429 1579 1610 717
35 1270 1488 1576 915
45 1055 1350 1477 1011
55 786 1145 1312 985
65 489 911 1185 886
75 245 822 1108 776
85 72 535 716 522
90 31 383 570
95 32 285 476 294
105 24 106 181 122
115 10 65 61 49
125 3 33 46 25
135 3 16 25 11
145 5815 6
155 6673
165 8772
175 8881
180 888
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1328 15.1 19.1 00-040 2242 25.5 32.3 00-060 4238 48.2 61.6 00-090 6422 73.0 92.6
90-120 465 5.3 6.7 90-130 490 5.6 7.1 90-150 507 5.8 7.3 90-180 513 5.8 7.4
00-180 6934 78.8 100.0
Ordering Information
Explanation of Catalog Number. Example: ST4WA232UNVHI
ST W A
Sealatron
Enclosed Industrial
Fluorescent
‡No product change. New Catalog Number Designation.
Options/Accessories
Water Tight Kits: One installed each end of fixture. For additional kits, order Catalog Number: STW-DC2. Electrical/Wiring Options: Consult factory. Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture. Suffix: R; One per ballast. Suffix: B. Fusing:Internal fast-blow fusing. Suffix: A.; Internal slow-blow fusing. Suffix: C.
Specifications
Materials: Inner Chassis parts are die-formed code gauge cold rolled steel, 1-5/8" deep x 4-5/8"
channel width. Lens: Molded, one-piece impact resistant .125" starting thickness smooth virgin acrylic with crepe on inner surface. Lens enclosure shall be fully gasketed to seal fixture from dirt, moisture and other cont­aminents.
Latches: Lock-tight molded cam-action tension latches, securely clamp to fixture. Finish: Inner chassis exterior–baked white polyester enamel, 84% minimum reflectance.
Fixture Length:
2=24" 4=48" 8=96"
(Nominal)
Wet/Damp
Location
W= Wet
Location
A=DR Acrylic
Crepe Lens
Two Top Mounting Brackets: Order Catalog Number:
STW TOP BRKT.
Two Surface or Chain Mounting Brackets:: Order Catalog Number:
STW END BRKTS.
Number of
Lamps
in Width: 1=1 Lamp
1 Lamp in Tandem
96" Unit
2=2 Lamp
2 Lamp in Tandem
96" Unit
Lamp/Fixture Length/Watts:
17 = 17W T8 2' Length
32 = 32W T8 4' Length 44HO = 44W T8, 380mA, 4' Length 48HO = 60W T12, 800mA, 4' Length
28 = 28W T5 4' Length
54 = 54W T5 4' Length
59SL = 59W SL T8, 8' Length 86HO = 86W T8, 380mA, 8' Length 96HO = 120W T12, 800mA, 8' Length
(1 or 2 Lamps in Tandem
for 8' Fixtures)
(Nominal 48")
Voltage:
120, 277 or
UNV=120-277
1 or 2 Lamp Elec. T12 SS – 1 or 2 Lamp Elec. T8 SO * HI * 1-4 Lamp Elec. T8 O4 * H4 * 1 & 2 Lamp 28W Elec. T5 PI 1 & 2 Lamp 28W Elec. T5 PG †† 1 & 2 Lamp 54W Elec. T5 PG †† 1-4 Lamp 54W Elec. T5 PV †† LOL T8 dimming PS
Other dimming options. Consult Factory. * Instant Start Standard † Instant Start (120, 277) †† Program Rapid Start (UNV only)
NOTE: For T8 UNV, you must use HI, H4 Ballast Code.
BALLAST:
<20THD <10THD
OPTIONS:
Add appropriate suffix to
catalog no., ie: (R)
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 05/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section7/Folio Q20-32 REV. F
Loading...