Specplus SPS2GFSVA2FT or 3FT
Page 1 of 2 2' x 2' Recessed Fluorescent, Lens Frame Troffer
Static, 2 or 3 Lamp, Twin Tube T5
Features
• 5" deep body.
• 3-1/4" lamp to lens for better lamp obscuration.
• 76.8% efficient (3 lamp TT5).
• Clean contoured interior, no holes.
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Slimline door frame with 475 square inch lens opening.
• Door jamb finished black on four sides for positive light stop.
• True mitered corner steel lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Flat and regressed aluminum doors available.
• Sky lens options avalible.
• Construction to meet NYC Code or Chicago Plenum requirements is
available.
Mounting Methods Dimensions
exposed T-grid ceiling.
G
(with flat aluminum frame)
plaster ceiling/flanged.
F
(with regressed aluminum frame)
Standard VA Lens
Optional Sky Lens
5" (127mm)
1/4" max.
24"
drywall kit (see options)
Type “G”
FIxture
Order Catalog Number: FK92X2.
1-1/2" max.
15/16"
or 1"
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
Plaster
Opening
24-1/8"
24-11/16"
exposed T-grid ceiling
(with flat steel frame)
24"
1/4" max.
1-1/8" min.
3-3/4" max.
13/16"
1-1/2" max.
15/16" or 1"
24" (610mm)
24" (610mm)
5"
(127mm)
2"x 2-1/2" access plate
with two K.O.s (7/8" dia.)
Job Information Type:
Job Name:
5" (127mm)
15-11/16"
(398mm)
23-7/8"
(606mm)
earthquake clip
before
installation
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
earthquake clip
installed
(lay-in grid)
Section 1A/Folio E60-22 Rev. B
Cat. No.:
Lamp(s):
Volts/Ballast:

Specplus SPS2GFSVA2FT or 3FT
Page 2 of 2 2' x 2' Recessed Fluorescent, Lens Frame Troffer
Static, 2 or 3 Lamp, Twin Tube T5
Photometry Sky Lens Options
Model No. SPS2GFSVA3FT120X3
LER = FP - 58.6 IW - 56.3 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $4.10
Report Number: G00045
Catalog Number: SPS2GFSVA3FT120X3
Lamps: (3) F40
Luminaire: 2' x 2' SpecPlus with regressed
aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).
Ballast: C340I120
Report is based on 3150 Lumens per lamp.
Efficiency: 76.8%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.875 21.875
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 84 81 78 76 74 72 73 71 70
02 78 72 67 68 64 61 65 62 60
03 71 64 58 61 56 52 58 55 51
04 66 57 51 54 49 45 53 48 45
05 61 52 45 49 44 40 48 43 39
06 56 47 40 45 39 35 44 39 35
07 53 43 36 41 36 32 40 35 31
08 49 39 33 38 32 28 37 32 28
09 46 36 30 35 29 26 34 29 26
10 43 33 28 32 27 24 32 27 23
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 3132 3132 3132
5 3115 3117 3135 297
15 2973 3016 3061 852
25 2697 2795 2882 1286
35 2265 2385 2465 1485
45 1677 1773 1880 1367
55 1027 1081 1151 971
65 565 528 585 557
75 285 261 341 316
85 106 113 143 128
90 000
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 7620. 8056. 8542.
55 5753. 6055. 6448.
65 4295. 4014. 4448.
75 3538. 3240. 4233.
85 3908. 4166. 5272.
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 2435 25.8 33.5
00-040 3920 41.5 54.0
00-060 6258 66.2 86.2
00-090 7260 76.8 100.0
90-180 0000 0.0 000.0
00-180 7260 76.8 100.0
S1
S2
Ordering Information
Explanation of Catalog Number. Example: SPS2GFSVA3FTUNVIB
S
Specplus:
Recessed
fluorescent
troffer
SP
SX
Options/Accessories
Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight
per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per
square foot. Substitute S1 or S2 for VA (standard) =
details).
Plaster Frame: Catalog Number: PF22.
Continuous Row Installation: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).
Radio Interference Filter:
Fusing: Internal fast-blow fusing. SUFFIX A.
Internal slow-blow fusing. SUFFIX C.
Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 3 lamp 40W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .81. To prevent glare the VCP shall
be not less than 29 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 4447 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 66.5%.
Static
Standard Specplus Plus
For NYC Code – Local 3 Manufactured
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
2
Fixture
Width
Ceiling Type:
G= Grid
(lay-in T bar)
F= Flanged (over
lap) Z spline and
plaster frame
Lens Frame:
FS = Flat steel
frame.
RA= Regressed
aluminum
frame.
FA = Flat aluminum
frame.
Sky Acrylic Lens (see Sky Lens sell sheet for further
Lens Shielding
VA=Virgin acrylic
S1=Sky lens 1
S2=Sky lens 2
See options and
consult factory
FT
Type:
(standard)
Lamp
Quantity
2=2 Lamp
3=3 Lamp
Specifications (continued)
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
over and housing ends turned-in for safe handling.
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating.
Lenses: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the
panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12
with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Lamp Type/
Fixture Length:
(Nominal 24")
Twin Tube T5
Note: For Linear
T5 Lamp option,
consult factory
Job Information Type:
Voltage:
120, 277 or
UNV=120-277
1–2 Lamp Elec. TT5 SB *
(40 Watt)
1–3 Lamp Elec. TT5 X3 *
(40 Watt)
LOL TT5 Dimming PB –
(40 Watt)
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For TT5 UNV, you must use
Ballast Type:
<20THD <10THD
IB,I
3 Ballast Code.
Options:
Add appropriate suffix
to catalog no., ie: (A)
IB *
I3 *
with side rails hemmed
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 1A/Folio E60-22 Rev. B