Lightolier SPECPLUS SPS2GFSVA32U, SpecplusSPS2GFSVA317, Specplus SPS2GFSVA32U12003 Specification

Specplus SPS2GFSVA32U or 317
Page 1 of 2 2' x 2' Recessed Fluorescent, Lens Frame Troffer
Static, 2 or 3 Lamp T8, 1-5/8"U or 2' Lamp
Features
• 5" deep body.
• 3-1/16" lamp to lens for better lamp obscuration.
• 67.9% efficient (3–1-5/8"U Lamp).
• Clean contoured interior, no holes.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Slimline door frame with 475 square inch lens opening.
• Door jamb finished black on four sides for positive light stop.
• True mitered corner steel lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Flat and regressed aluminum doors available.
• Sky lens options avalible.
• Construction to meet NYC Code or Chicago Plenum requirements is available.
Mounting Methods Dimensions
exposed T-grid ceiling.
G
(with flat aluminum frame)
plaster ceiling/flanged.
F
(with regressed aluminum frame)
Standard VA Lens
Optional Sky Lens
5" (127mm)
1/4" max.
24"
drywall kit (see options)
Type “G”
FIxture
Order Catalog Number: FK92X2.
1-1/2" max.
15/16"
or 1"
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
Plaster
Opening
24-1/8"
24-11/16"
exposed T-grid ceiling (with flat steel frame)
24"
1/4" max.
1-1/8" min. 3-3/4" max.
13/16"
1-1/2" max.
15/16" or 1"
24" (610mm)
24" (610mm)
5"
(127mm)
2"x 2-1/2" access plate with two K.O.s (7/8" dia.)
Job Information Type:
Job Name:
15-11/16"
(398mm)
5" (127mm)
23-7/8"
(606mm)
earthquake clip
before
installation
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group
earthquake clip
installed
(lay-in grid)
Section 1A/Folio E60-24 Rev. B
Cat. No.:
Lamp(s):
Volts/Ballast:
Specplus SPS2GFSVA32U or 317
Page 2 of 2 2' x 2' Recessed Fluorescent, Lens Frame Troffer
Static, 2 or 3 Lamp T8, 1-5/8"U or 2' Lamp
Photometry Sky Lens Options
Model No. SPS2GFSVA32U12003
LER = FP - 64.1 IW - 76.2 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $3.74
Report Number: G00057 Catalog Number: SPS2GFSVA32U12003 Lamps: (3) U6T8 Luminaire: 2' x 2' SpecPlus with regressed
aluminum door frame and extruded virgin acrylic shielding .095" nominal
thickness (similar to pattern 12). Ballast: REL-3P32-SC Report is based on 2725 Lumens per lamp.
Efficiency: 67.9% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.875 21.875
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 75 72 69 67 65 63 65 63 62 02 69 63 59 60 57 54 58 55 53 03 63 56 51 53 49 46 52 48 45 04 58 51 45 48 44 40 46 43 39 05 54 46 40 43 39 35 42 38 35 06 50 41 36 39 35 31 38 34 31 07 46 38 32 36 31 28 35 31 28 08 43 34 29 33 28 25 32 28 25 09 40 32 26 31 26 23 30 26 23
10 38 29 24 28 24 21 28 24 21
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 2391 2391 2391
5 2376 2376 2382 226
15 2269 2289 2315 647
25 2056 2106 2160 971
35 1728 1799 1877 1126
45 1277 1361 1467 1051
55 786 840 909 755
65 434 411 460 434
75 219 201 264 244
85 82 87 109 98
90 000
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 5803. 6184. 6666. 55 4403. 4705. 5092. 65 3300. 3125. 3497. 75 2719. 2495. 3277. 85 3023. 3207. 4018.
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1844 22.6 33.2 00-040 2970 36.3 53.5 00-060 4776 58.4 86.0 00-090 5552 67.9 100.0
90-180 0000 0.0 000.0
00-180 5552 67.9 100.0
S1
S2
Ordering Information
Explanation of Catalog Number. Example: SPS2GFSVA32UUNVH3
S
Specplus:
Recessed
fluorescent
troffer
SP
SX
Options/Accessories
Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight
per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per square foot. Substitute S1 or S2 for VA (standard) = further details).
Plaster Frame: Catalog Number: PF22. Continuous Row Installation: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: 2FC TRIM CSP (each joint). Radio Interference Filter:
Fusing: Internal fast-blow fusing. SUFFIX A.
Internal slow-blow fusing. SUFFIX C. Electrical Wiring Options: Consult factory. Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A). Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 3 lamp 31W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .72. To prevent glare the VCP shall be not less than 35 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 3497 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.8%.
Static
Standard Specplus Plus
For NYC Code – Local 3 Manufactured
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
2
Fixture
Width
Ceiling Type:
G= Grid
(lay-in T bar)
F= Flanged (over
lap) Z spline and plaster frame
FS = Flat steel
RA= Regressed
FA = Flat aluminum
Sky Acrylic Lens (see Sky Lens sell sheet for
Lens Frame:
frame.
aluminum frame.
frame.
Lens Shielding
VA=Virgin acrylic
S1=Sky lens 1 S2=Sky lens 2
See options and
consult factory
Type:
(standard)
Lamp
Quantity
2=2 Lamp 3=3 Lamp
Specifications (continued)
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Lenses: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. aver­age weight per square foot. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W. UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Lamp Type/
Fixture Length:
2U=T8, 1-5/8"U Lamp 17=T8, 2' Lamp
(Nominal 24")
Note: For Linear T5 Lamp option,
consult factory
Voltage:
120, 277 or
UNV=120-277
1 & 2 Lamp Elec. T8 SO * H 1–3 Lamp Elec. T8 O3 * H3 *
LOL T8 Dimming PS *Instant Start Standard Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use H
Ballast Type:
<20THD <10THD
I
, H3 Ballast Code.
Job Information Type:
Options:
Add appropriate suffix
to catalog no., ie: (A)
I *
with side rails hemmed
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group
Section 1A/Folio E60-24 Rev. B
Loading...