Specplus SPS2GFSVA26U or 217
Page 1 of 2 2' x 2' Recessed Fluorescent, Lens Frame Troffer
Static, 2 Lamp, T8
Features
• 5" deep body.
• 3-1/16" lamp to lens for better lamp obscuration.
• 71.6% efficient.
• Clean contoured interior, no holes.
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Slimline door frame with 475 square inch lens opening.
• Door jamb finished black on four sides for positive light stop.
• True mitered corner steel lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Flat and regressed aluminum doors available.
• Sky lens options avalible.
• Construction to meet NYC Code or Chicago Plenum requirements is
available.
Mounting Methods Dimensions
exposed T-grid ceiling.
G
(with flat aluminum frame)
plaster ceiling/flanged.
F
(with regressed aluminum frame)
Standard VA Lens
Optional Sky Lens
5" (127mm)
Plaster
1/4" max.
1-1/2" max.
24"
drywall kit (see options) exposed T-grid ceiling
Type “G”
FIxture
Order Catalog Number: FK92X2.
15/16"
or 1"
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
Opening
24-1/8"
24-11/16"
(with flat steel frame)
24"
1/4" max.
1-1/8" min.
3-3/4" max.
13/16"
1-1/2" max.
15/16" or 1"
24" (610mm)
24" (610mm)
5"
(127mm)
2"x 2-1/2" access plate
with two K.O.s (7/8" dia.)
Job Information Type:
Job Name:
15-11/16"
(398mm)
23-7/8"
(606mm)
5" (127mm)
earthquake clip
before
installation
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
earthquake clip
installed
(lay-in grid)
Section 1A/Folio E60-20 Rev. B
Cat. No.:
Lamp(s):
Volts/Ballast:

Specplus SPS2GFSVA26U or 217
Page 2 of 2 2' x 2' Recessed Fluorescent, Lens Frame Troffer
Static, 2 Lamp, T8
Photometry Sky Lens Options
Model No. SPS2GFSVA26U120SO
LER = FP - 58.6 IW - 56.3 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $4.10
Report Number: G00035
Catalog Number: SPS2GFSVA26U120SO
Lamps: (2) U6T8
Luminaire: 2' x 2' SpecPlus with regressed
aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).
Ballast: REL-2P32-SC
Report is based on 2750 Lumens per lamp.
Efficiency: 71.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.875 21.875
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 79 75 73 71 69 67 68 66 65
02 72 67 62 63 59 56 61 58 55
03 66 59 54 56 52 48 54 51 47
04 61 53 47 50 46 42 49 45 41
05 56 48 42 45 40 37 44 40 36
06 52 43 37 41 36 32 40 36 32
07 49 39 33 38 33 29 37 32 29
08 45 36 30 35 30 26 34 29 26
09 42 33 28 32 27 24 31 27 23
10 40 31 25 30 25 21 29 25 21
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1669 1669 1669
5 1659 1658 1661 158
15 1578 1593 1614 451
25 1431 1464 1502 675
35 1212 1249 1309 785
45 913 960 1068 750
55 572 611 673 551
65 318 302 342 319
75 160 146 192 178
85 58 62 78 70
90 000
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 4164. 4410. 4906.
55 3239. 3460. 3811.
65 2444. 2321. 2629.
75 2008. 1832. 2410.
85 2162. 2311. 2907.
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1283 23.3 32.6
00-040 2069 37.6 52.6
00-060 3369 61.3 85.6
00-090 3936 71.6 100.0
90-180 0000 0.0 000.0
00-180 3936 71.6 100.0
S1
S2
Ordering Information
Explanation of Catalog Number. Example: SPS2GFSVA26UUNVHI
S
Specplus:
Recessed
fluorescent
troffer
SP
SX
Options/Accessories
Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per
square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per
square foot. Substitute S1 or S2 for VA (standard) =
further details).
Plaster Frame: Catalog Number: PF22.
Continuous Row Installation: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).
Radio Interference Filter:
Fusing: Internal fast-blow fusing. SUFFIX A.
Internal slow-blow fusing. SUFFIX C.
Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To prevent glare the VCP shall
be not less than 40 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 2629 candelas per square meter. To control veiling reflections, luminaire output inthe
30°-90° zone shall not be less than 67.4%.
Static
Standard Specplus Plus
For NYC Code – Local 3 Manufactured
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
2
Fixture
Width
Ceiling Type:
G= Grid
(lay-in T bar)
F= Flanged (over
lap) Z spline and
plaster frame
FS = Flat steel
RA= Regressed
FA = Flat aluminum
Sky Acrylic Lens (see Sky Lens sell sheet for
Lens Frame:
frame.
aluminum
frame.
frame.
Lens Shielding
VA=Virgin acrylic
(standard)
S1=Sky lens 1
S2=Sky lens 2
See options and
consult factory
2
Type:
Lamp
Quantity
Specifications (continued)
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
over and housing ends turned-in for safe handling.
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating.
Lenses: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the
panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12
with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz.
average weight per square foot.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Lamp Type/
Fixture Length:
6U =
6"U Lamp T8
17 =
T8
(Nominal 24")
Note: For Linear
T5 Lamp option,
consult factory
Job Information Type:
Voltage:
120, 277 or
UNV=120-277
1–2 Lamp Elec. T8 SO * HI *
LOL T8 Dimming PS –
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H
Ballast Type:
<20THD <10THD
I
Ballast Code.
Options:
Add appropriate suffix
to catalog no., ie: (A)
with side rails hemmed
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 1A/Folio E60-20 Rev. B