Lightolier SN STRIP User Manual

SN SERIES SN STRIP
Page 1 of 2 NARROW WIDTH CHANNEL
2 1/2" WIDE x 1 13/16" DEEP x 18", 24", 36", 48", 72", 96" LENGTHS, ONE LAMP, T8 OR T12
Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 3A/Folio H110-40
Features
• Fixtures suitable for individual, row, surface, or suspension mounting.
• Efficiency 94% (T8).
• Quarter turn latch secures channel cover for easy wireway access.
• Heavy duty channel of code gauge die formed steel.
• Only 2-1/2" wide.
• Fully enclosed wiring.
• U.L. Listed snap-on end caps.
• Combination end cap for continuous row mounting.
• Green grounding screw installed in channel.
• UL listed for direct mounting on low density ceilings and damp locations.
SN SERIES SN STRIP
Page 2 of 2 NARROW WIDTH CHANNEL
2 1/2" WIDE x 1 13/16" DEEP x 18", 24", 36", 48", 72", 96" LENGTHS, ONE LAMP, T8 OR T12
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 3A/Folio H110-40
Job Information Type:
SPECIFICATIONS
MATERIALS: Chassis parts are die-formed heavy gauge cold rolled steel,
1-13/16" deep x 2-1/2" channel width.
BALLAST COVER: Code gauge steel secured with 1/4" turn fasteners. FINISH: Chassis exterior phosphate undercoating, baked white polyester enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved,
non-PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and ULc Listed.
ORDERING INFORMATION Explanation ot Catalog Number Example: SN4S130LPF120SOGLR
OPTIONS/ACCESSORIES
FUSING: Internal fast-blow fusing.
SUFFIX: GLR. Internal slow-blow fusing.
SUFFIX: GMF. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. FLUORESCENT EMERGENCY LIGHTING SYSTEM: Factory-installed emergency power battery pack with charger and inverter. SUFFIX: EM. STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24")
CANOPY SPACER: Suspends fixture 1-1/2" from surface. Order Catalog Number: AC1 CSP
GROUNDED CONVENIENCE OUTLET: 120 volt only. SUFFIX: CO. 4' WIRE GUARD: Catalog Number: AWG1W CSP. REFLECTORS: Order Catalog Number: SYMMETRICAL: NSYMC20 CSP (24")
NSYMC30 CSP (36") NSYMC40 CSP (48")
ASYMMETRICAL: NASYC20 CSP (24")
NASYC30 CSP (36") NASYC40 CSP (48")
Loading...