Lightolier SL403A User Manual

Spectral Architectural Lighting SL403A
01-03
Zylinder Wall Spectral
Optic Forms Architectural Lighting
1-150W T7 Ceramic Metal Halide
SL403A
01-03
Zylinder Wall Spectral
Optic Forms Architectural Lighting
SL403A
Page 1 of 2 Zylinder Wall Optic Forms 1-150W T7 Ceramic Metal Halide
9 1/4"
(235 mm)
10 1/4"
(260 mm)
Ordering Guide (complete unit only)
1 1/2"
(38 mm)
7 1/8"
(181 mm)
15 1/4"
(387 mm)
5 7/8"
(150 mm)
Cat. No. Lamp (Clear) Volt Finish
SL403AH1 1-150W T6 CMH (M142) (clear) 120V (electronic) Stainless Steel & Etched Glass SL403AH2 1-150W T6 CMH (M142) (clear) 277V (electronic) Stainless Steel & Etched Glass SL403AHT 1-150W T6 CMH (M142) (clear) 120/277/347V (magnetic) Stainless Steel & Etched Glass
Features
1. Optical System: Single lamp powers an upper wide spaced indirect optic
and a lower narrow spaced direct sand-blasted optic. Glass shield redirects light into the space. Upper wide spaced spun Alzak® optic with clear glass micro switch protected. Narrow spacing spun Alzak® downlight optic. Bottom glass sandblasted outer ring with clear centre.
2. Stainless Steel Construction: Quality all stainless steel form and
hardware.
3. Hardware: Exposed hardware adds high design element to the form.
5. Ballast Compartment: Perforated stainless steel construction with
removeable ballast cover Hollow rods shield wiring to optical chamber.
6. Optical Chamber: Circular brushed stainless steel construction and all
stainless steel hardware.
7. Ceramic lamp source: CMH lamp source assures stable color over the life
of the lamp and longer lamp life.
8. Wall Plate: Stainless steel construction with additional holes for securing
the installation and provided with an overlapping support for Ballast Compartment.
9. Flange: Stainless steel that separate Wall Plate and Ballast Compartment..
Electrical (continued)
H1: Electronic Ceramic MH / CMH 120V H2: Electronic Ceramic MH / CMH 277V
Magnetic Ballast: CWA (Constant Wattage Autotransformer) with triple tap
120/277/347 volts operation. Ballast maintains steady lamp operating character­istics for longer lamp life and color stability.
HT: Magnetic CWA MH 120/277/347V
Options and Accessories
For pendant unit, see Zylinder Glas SL402.
Fuse: 2 Amps internal fusing. Consulting your Lightolier representative. Add code (-F1) for 120 volts, (-F2) for 277 volts or (-F3) for 347 volts.
Finish
Stainless steel: brushed high quality stainless steel alloy.
Labels
UL “c/us” Listed. For dry locations only.
Mounting
Mounting: Suitable for mounting on standard octogonal box. Must be held in
place by additional hardware to support heavy weight luminaire.
Luminaire Weight: 12.5 lbs. (magnetic), 9 lbs. (electronic)
Electrical
Lampholder: RX7s, double-ended base.
Electronic Ballast: Electronic Ceramic MH ballast maintains constant lamp
characteristics throughout the life of the lamp and through a wide range of oper­ating voltages. Ballasts available for 120 and 277 volts operation. No universal ballast option.
Microswitch: Remote, turn off electricity during maintenance into the lamp compartment.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
Spectral Architectural Lighting SL403A
01-03
Zylinder Wall Spectral
Optic Forms Architectural Lighting
1-150W T7 Ceramic Metal Halide
SL403A
ZONE DEG
0 22,5 45 67,5 90
0 261 261 261 261 261
5 267 265 264 262 261
10 280 277 274 270 266
15 299 297 292 277 269
20 317 316 306 283 273
25 328 332 315 291 273
30 335 340 330 301 278
35 334 341 332 305 278
40 324 332 331 307 282
45 308 317 322 306 275
50 276 293 309 298 268
55 226 250 287 286 257
60 152 187 250 273 236
65 74 106 191 251 214
70 24 41 112 212 181
75 9 16 43 156 143
80 49 39 23 68 93
85 99 83 53 36 42
90 143 137 97 59 15
95 236 236 180 106 27
100 337 337 260 150 61
105 439 432 335 191 99
110 532 520 406 223 134
115 615 601 464 261 170
120 687 666 866 302 199
125 748 709 555 324 231
130 785 739 577 351 264
135 803 752 578 364 294
140 801 744 574 378 311
145 766 712 890 381 326
150 708 658 526 381 339
155 628 595 484 375 335
160 551 522 439 365 335
165 457 439 398 357 324
170 382 374 358 348 324
175 341 339 333 323 305
180 318 318 318 318 318
CANDLEPOWER
50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .56 .56 .56 .56 .49 .49 .49 .49 .37 .37 .37 .25 .25 .25 .15 .15 .15 .10
1 .52 .50 .48 .46 .46 .44 .43 .41 .33 .32 .32 .23 .23 .22 .14 .14 .14 .10
2 .48 .44 .42 .39 .42 .39 .37 .35 .30 .29 .27 .22 .21 .20 .14 .13 .13 .10
3 .44 .40 .37 .34 .39 .36 .33 .31 .28 .26 .24 .20 .19 .18 .13 .13 .12 .10
4 .41 .36 .33 .30 .37 .33 .29 .27 .25 .23 .22 .19 .18 .17 .13 .12 .12 .09
5 .38 .33 .29 .26 .34 .30 .27 .24 .23 .21 .20 .18 .16 .16 .12 .12 .11 .09
6 .36 .30 .27 .24 .32 .27 .24 .22 .22 .20 .18 .17 .15 .15 .12 .11 .11 .09
7 .34 .28 .24 .22 .30 .25 .22 .20 .20 .18 .17 .16 .14 .14 .11 .11 .11 .09
8 .32 .26 .22 .20 .28 .23 .20 .18 .19 .17 .16 .15 .14 .13 .11 .11 .10 .09
9 .30 .24 .21 .18 .27 .22 .19 .17 .18 .16 .15 .14 .13 .12 .11 .10 .10 .09
10 .28 .23 .19 .17 .25 .21 .18 .16 .17 .15 .14 .14 .12 .12 .10 .10 .10 .08
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
LUMINAIRES INPUTS WATTS = 168.6
ROOM CAVITY RATIO
ZONAL CAVITY METHOD • EFFECTIVE FLOOR CAV ITY REFLECTANCE = .20
COEFFICIENTS OF UTILIZATION
Wall Reflectance
80 70
DISTRIBUTION
Zone Lumens % Lamp % Luminaire
0-30 1291 9.75 17.24
0-40 1318 9.95 17.60
0-60 1318 9.95 17.60
0-90 1318 9.95 17.60
90-120 0 0.00 0.00
90-150 0 0.00 0.00
90-180 6173 46.59 82.40
0-180 7492 56.54 100.00
REPORT NO: C9680.IES CAT. NO: SL403AH1
1 x 150W T7 at 13250 lumens
Efficienc
y
: 56.5%. Indirect Maximum candela: 657
7
Indirect Peak at 175º . Candela at Nadir: 11625
90°
180°
1
1
0
0
0
2
7
5
0
5
5
0
0
8
2
5
0
01-03
Zylinder Wall Spectral
Optic Forms Architectural Lighting
SL403A
Page 2 of 2 Zylinder Glas Optic Forms 1-150W T7 Ceramic Metal Halide
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Loading...