Skyway SKS2GPK214 or 224
Page 1 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 Lamp T5 or T5HO
Features
• Aesthetically pleasing triple lens design.
• Curved high light transmission frost white acrylic side lenses.
• Clear acrylic conical prismatic center lens.
• Internal reflector coated with 95% reflective white paint.
• 72.8% efficient 2 Lamp 14 watt T5.
• 74.6% efficient 2 Lamp 24 watt T5HO.
• 5" deep body.
• Black housing exterior for cooler ballast operating temperature.
• Eyeleted heat removal vents in fixture ends.
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Door jamb finished black on four sides for positive light stop.
• True mitered corner aluminum lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Construction to meet NYC Code Requirements or Chicago Plenum is available.
Mounting Methods Dimensions
24" (610mm)
2" max.
24"
Exposed T-grid ceiling.
G
earthquake clip installed (lay-in grid)
15/16"
9/16"
5"
(127mm)
2" max.
or
T
Drywall Kit, Catalog Number: FK92X2.
24"
Exposed Slot T-grid ceiling
Skyway
Fixture
15/16"
or
9/16"
Support (by others)
Drywall Kit
(See Options)
Drywall
(by others)
Air supply slots
(SKA Only)
2" X 2-1/2" Access Plate with (2)
7/8" (73mm) Dia. KO’s
5"
(127mm)
23-7/8"
(606mm)
15-11/16"
(398mm)
Job Information Type:
Job Name:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 08/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Cat. No.:
Lamp(s):
Volts/Ballast:
Section 5/Folio MA12-12 Rev. A

Skyway SKS2GPK214 or 224
Page 2 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 Lamp T5 or T5HO
Model No. SKS2GPK214UNVPG
LER = FP - 56.4 IW - 32.5 BF - 1.05
Comparative yearly lighting energy cost per
1000 lumens = $4.25
Report Number: G2008325
Catalog Number: SKS2GPK214UNVPG
Lamps: (2) F14T5/835/ALTO
Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly.
Ballast: ICN-2S28-SC
Report is based on 1200 Lumens per lamp.
Efficiency: 72.8%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.600 21.600
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 80 77 74 72 70 68 69 68 66
02 73 68 63 64 60 57 62 59 56
03 67 60 55 57 53 49 55 51 48
04 62 54 48 51 46 43 50 45 42
05 57 49 42 46 41 37 45 40 37
06 53 44 38 42 37 33 41 36 33
07 49 40 34 38 33 29 37 33 29
08 46 37 31 35 30 26 34 30 26
09 43 34 28 33 28 24 32 27 24
10 41 31 26 3O 25 22 30 25 22
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 748 748 748
5 743 742 742 71
15 704 705 705 199
25 633 643 669 299
35 533 578 612 358
45 405 420 414 323
55 263 269 251 237
65 151 153 142 154
75 79 76 68 82
85 19 18 15 23
90 562
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 568 23.7 32.6
00-040 927 38.6 53.1
00-060 1487 62.0 85.2
00-090 1746 72.8 100.0
90-180 0000 0.0 000.0
00-180 1746 72.8 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1902. 1973. 1944.
55 1523. 1558. 1453.
65 1187. 1202. 1116.
75 1014. 975. 873.
85 724. 686. 572.
Model No. SKS2GPK224UNVPG
LER = FP - 52.4 IW - 51.3 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $4.58
Report Number: G2008179
Catalog Number: SKS2GPK224UNVPG
Lamps: (2) F24T5HO
Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly.
Ballast: ICN-2S24
Report is based on 1800 Lumens per lamp.
Efficiency: 74.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.600 21.600
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 82 79 76 74 72 70 71 69 68
02 75 70 65 66 62 59 63 60 58
03 69 62 56 59 54 51 57 53 50
04 64 55 49 53 48 44 51 47 43
05 59 50 44 48 42 38 46 42 38
06 55 45 39 43 38 34 42 37 34
07 51 41 35 40 34 30 39 34 30
08 47 38 32 36 31 27 35 31 27
09 44 35 29 34 28 25 33 28 25
10 42 32 27 31 26 23 30 26 23
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1153 1153 1153
5 1145 1145 1146 109
15 1087 1094 1101 309
25 977 1007 1055 467
35 822 901 954 557
45 625 648 639 497
55 399 412 384 362
65 224 231 215 231
75 113 113 103 122
85 26 24 21 21
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 885 24.6 32.9
00-040 1442 40.0 53.7
00-060 2301 63.9 85.7
00-090 2685 74.6 100.0
90-180 0000 0.0 000.0
00-180 2685 74.6 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2935. 3043. 3001.
55 2310. 2385. 2223.
65 1760. 1815. 1689.
75 1450. 1450. 1322.
85 991. 914. 800.
Ordering Information
Explanation of Catalog Number. Example: SKS2GPK214UNVPG
K
Center Lens:
K= Pattern 19
.156 Virgin
Acyrlic Lens
Skyway
Recessed
Fluorescent
SK
SY
2
Body Style:
S = Static
A = Air
Standard Skyway
For NYC Code – I.B.E.W. Manufactured
Fixture
Width
Ceiling Type:
G = Standard
Grid
T = Slot Grid
P
Side Lens:
P= Frost White
Acrylic Lens
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications
Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77.
To reduce glare the average brightness at 65° shall not exceed 1202 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 67.4%.
Air Handling: (SKA only) side air passages for air supply or air return. Supply air is
discharged vertically. Optional side closure strips. Air return is also provided through the
lamp compartment through fixture body ends.
2
Lamp
Quantity
2=2 Lamp
Specifications (continuned)
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
hemmed over and housing ends turned-in for safe handling.
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating. Reflectors-
95% reflective white powder coated.
Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org
Job Information Type:
Lamp:
(By Others)
14=T5 14W
24=T5HO 24W
(Nominal 24")
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
2 Lamp Elec. T5 – PG ††
(14 Watt)
2 Lamp Elec. T5HO – PG ††
(24 Watt)
††Program Rapid Start (UNV only)
<20THD < 10THD
Options:
Add appropriate suffix
to catalog no., ie: (A)
has side rails
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 08/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 5/Folio MA12-12 Rev. A