Lightolier SKS2GPK217, SKS2GPK317 User Manual

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 a Philips Group Section 5/Folio MA12-14
Lightolier is a Philips group brand
01/09
Job Information Type:
Cat. No.:
Lamp(s):
Volts/Ballast:
Features
• Aesthetically pleasing triple lens design.
• Curved high light transmission frost white acrylic side lenses.
• Clear acrylic conical prismatic center lens.
• Internal reflector coated with 95% reflective white paint.
• 70.7% efficient 2 Lamp 17 watt T8.
• 72.9% efficient 3 Lamp 17 watt T8.
• 5" deep body.
• Black housing exterior for cooler ballast operating temperature.
• Eyeleted heat removal vents in fixture ends.
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips (patent no. 5,072,344).
• Door jamb finished black on four sides for positive light stop.
• True mitered corner aluminum lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Construction to meet NYC Code Requirements or Chicago Plenum is available.
Skyway SKS2GPK217 or 317
Page 1 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 or 3 Lamp T8
5"
(127mm)
2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s
23-7/8"
(606mm)
24" (610mm)
5"
(127mm)
Mounting Methods Dimensions
Exposed T-grid ceiling.
24"
15/16"
or
9/16"
2" max.
earthquake clip installed (lay-in grid)
Exposed Slot T-grid ceiling
2" max.
24"
Skyway Fixture
Support (by others)
Drywall Kit (See Options)
Drywall
(by others)
Drywall Kit, Catalog Number: FK92X2.
G
T
15/16"
or
9/16"
15-11/16"
(398mm)
Air supply slots
(SKA Only)
5"
(127mm)
24" (610mm)
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 a Philips Group Section 5/Folio MA12-14
Job Information Type:
Lightolier is a Philips group brand
Skyway SKS2GPK217 or 317
Page 2 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 or 3 Lamp T8
Ordering Information
Explanation of Catalog Number. Example: SKS2GPK217UNVHI
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications
Performance: In an installation of 2 lamp 17W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To reduce glare the average brightness at 65° shall not exceed 1375 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 67.6%. Air Handling: (SKA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provid­ed through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
has side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating.
Reflectors- 95% reflective white powder coated.
Specifications (continuned)
Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix to catalog
no., ie: (A)
Skyway
Recessed
Fluorescent
Body Style:
S = Static
A = Air
2
Fixture
Width
Ceiling Type:
G = Standard
Grid
T = Slot Grid
P
Side Lens:
P= Frost White
Acrylic Lens
17
K
Center Lens: K= Pattern 19
.156 Virgin Acyrlic Lens
0.0 45.0 90.0 FLUX
0 845 845 845
5 839 838 839 80
15 796 797 801 225
25 714 727 752 337
35 602 648 695 405
45 459 477 474 367
55 297 308 287 270
65 171 175 162 175
75 89 86 79 94
85 21 24 17 26
90 773
Model No. SKS2GPK217UNVHI
LER = FP - 58.1 IW - 31.7 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $4.13
Report Number: G2008293 Catalog Number: SKS2GPK217UNVHI Lamps: (2) F17T8/TL835/PLUS/ALTO Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly. Ballast: ICN-2P32-SC Report is based on 1400 Lumens per lamp.
Efficiency: 70.7% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2156. 2240. 2226. 55 1720. 1783. 1662. 65 1344. 1375. 1273. 75 1142. 1103. 1014. 85 800. 914. 648.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01787572706866676664 02716661625956605754 03655953555148535047 04605247504541484441 05564741454036443936 06524337413632403532 07483933373229363228 08453630342926332926 09423327322723312623
10 39 30 25 29 25 21 29 24 21
ZONE LUMENS % LAMP % FIXT
00-030 642 22.9 32.4 00-040 1047 37.4 52.9 00-060 1684 60.1 85.1 00-090 1979 70.7 100.0
90-180 0000 0.0 000.0
00-180 1979 70.7 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 1391 1391 1391
5 1384 1378 1381 131
15 1312 1309 1315 370
25 1175 1172 1166 539
35 984 952 956 602
45 720 714 732 553
55 447 475 435 412
65 260 274 249 269
75 140 131 125 145
85 33 35 28 39
90 12 13 5
Model No. SKS2GPK317UNVH3
LER = FP - 46.8 IW - 46.6 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $5.13
Report Number: G2008296 Catalog Number: SKS2GPK317UNVH3 Lamps: (3) F217T8.TL835/PLUS/ALTO Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly. Ballast: ICN-3P32-SC Report is based on 1400 Lumens per lamp.
Efficiency: 72.9% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.1 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3382. 3353. 3438. 55 2588. 2750. 2519. 65 2043. 2153. 1957. 75 1796. 1681. 1604. 85 1257. 1334. 1067.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01807774727068696866 02746864646158625956 03686155575349555249 04625448514743504642 05584943474238454137 06534438423733413733 07504034393430383330 08463731363127353027 09443429332824322824
10 41 32 26 31 26 22 30 25 22
ZONE LUMENS % LAMP % FIXT
00-030 1040 24.8 34.0 00-040 1642 39.1 53.7 00-060 2607 62.1 85.2 00-090 3060 72.9 100.0
90-180 00000.0000.0
00-180 3060 72.9 100.0
ZONAL LUMEN SUMMARY
SK
Standard Skyway
SY
For NYC Code – I.B.E.W. Manufactured
NK
For NYC Code – Local 3 Manufactured
Lamp:
(By Others)
17 =T8 17W
(Nominal 24")
Lamp
Quantity 2=2 Lamp 3=3 Lamp
Ballast Type:
Ballast
<20THD <10THD Factor
1 or 2 Lamp Elec. T8 SO* H
I* 0.88
1-3 Lamp Elec. T8 O3* H3* 0.88 Advance Optanium
1 or 2 Lamp Elec. T8 C5* 0.80 1 - 3 Lamp Elec. T8 C6* 0.81
LOL Dimming T8 PS* *Instant Start Standard Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use H
I
OR H3 Ballast Code.
Loading...