Lightolier RTR12 User Manual

GUARDSMAN GVS SERIES 2X2
Page 1 of 2 VANDAL RESISTANT, 2'x2' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12
MOUNTING METHODS DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 6A/Folio P20-51
Features
• Excellent for locations where vandal resistance is required.
• Prismatic lens is 3/16" thick pattern 12, minimum impact strength, 130 foot pounds.
• Full perimeter gasketing (closed cell Neoprene) between door frame and lens.
• Tamper resistant holt head screws secure lens to housing.
• 5" deep body.
• 69.3% efficient (T8).
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips (patent no. 5,072,344).
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
exposed T-grid ceiling (with flat steel frame)
FG
plaster ceiling/flanged. (with regressed aluminum frame)
earthquake clip
installed
(lay-in grid)
earthquake clip
before
installation
23-7/8"
(606mm)
15-11/16"
(398mm)
5"
(127mm)
2"x 2-1/2" access plate with two K.O.s (7/8" dia.)
drywall kit (see options) gasketing detail
Gasketing
(Close Cell Neoprene)
Door Frame
Latch
Fixture
Lens
Holt Head Screw
Type “G”
FIxture
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
15/16"
15/16" or 1"
1-1/2" max.
1/4" max.
1-1/8" min. 3-3/4" max.
13/16"
24"
Ceiling Opening
24-5/16" x 24-5/16"
Plaster
Opening
24-1/8"
24-11/16"
24" (610mm)
5" (127mm)
VOLTAGE:
120 or 277
BALLAST TYPE:
1-2 Lamp Mag. T12 LE
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I*
1-2 Lamp Elec. T8 SO* H
I*
1-2 Lamp Elec. TT5 SB*
IB*
(40 Watt)
1-3 Lamp Elec. TT5 X3*
I3*
1-4 Lamp Elec. T8 O4* H4* LOL Dimming (T8) PS LOL Dimming (TT5) PB
*Instant Start Standard
OPTIONS:
Add appropriate suffix to
catalog no., ie: (GLR)
GUARDSMAN GVS SERIES 2X2
Page 2 of 2 VANDAL RESISTANT, 2'x2' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902
Section 6A/Folio P20-51
Job Information Type:
OPTIONS & ACCESSORIES
SCREWDRIVER: For holt head screw. Order Catalog Number LP156737. PLASTER FRAME: Catalog Number PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. FUSING: Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF. ELECTRICAL/WIRING OPTIONS: Consult factory. DRYWALL KIT: Order Catalog Number: FK92X2.
Request Folio OA30-10.
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .73. To prevent glare the VCP shall be not less than 40 either length­wise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2144 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.0%.
SPECIFICATIONS (continued)
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing with side rails hemmed over and housing ends turned-in for safe han­dling. FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENS: (VK) prismatic lens is 3/16" thick, pattern 12, minimum impact strength, 130 foot pounds. ELECTRICAL: Thermally protected class "P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY MODEL NO. GVS2GFSVK26U
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1767371 696765 666463 2706561 615855 595654 3655853 555147 535047 4605246 494541 484441 5554741 454036 433936 6514337 413632 403532 7483933 373229 363229 8443630 342926 332926 9423327 322724 312723
10 39 30 25 29 25 22 29 24 21
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 65 69 76 81 64 68 74 79 20 30 58 62 68 73 56 60 66 71 20 40 54 58 63 66 51 55 61 65 20 60 51 55 58 62 46 51 55 59
30 20 66 70 75 80 65 69 74 78 30 30 58 62 67 71 56 60 66 69 30 40 54 57 61 64 50 54 59 63 30 60 50 53 56 59 46 50 53 57 30 80 49 51 53 56 44 47 49 53
40 20 67 71 76 80 66 71 75 79 40 30 59 63 67 71 57 62 66 70 40 40 54 57 61 64 51 55 59 63 40 60 50 53 55 58 46 50 53 57 40 80 49 51 52 55 44 47 49 52 40 100 48 50 50 53 43 45 46 50
60 30 60 64 67 71 58 63 67 70 60 40 55 58 61 64 52 56 59 63 60 60 51 53 55 58 47 50 52 56 60 80 49 51 51 54 44 47 48 52 60 100 48 49 49 52 43 45 45 49
100 40 57 60 62 66 56 59 61 65 100 60 53 55 56 59 50 53 54 58 100 80 50 52 52 55 47 49 50 53 100 100 49 50 49 52 45 46 46 48
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: GVS2GFSVK26U120SOGLR
GV
GUARDSMAN
VANDAL
RESISTANT
S
STATI C
2
FIXTURE
WIDTH
CEILING TYPE: G= Grid (lay-in T bar) F=Flanged (overlap) Z spline
and plaster frame
FS
LENS FRAME:
FS= Flat steel frame
VK
LENS/SHIELDING TYPE:
VK=High impact
Prismatic lens (standard)
LAMP QUANTITY:
2=2 Lamp 3=3 Lamp
(Not with 6" spacing)
4=4 Lamp
(T8, 2' Lamp Only)
LAMP/
FIXTURE LENGTH: 6U=6"U Lamp T8 or T12 2U=T8, 1-5/8" U Lamp FT=Twin Tube T5 17=T8, 2' Lamp
(Nominal 24")
Other dimming options. Consult factory.
LER = FL - 58.9 IW - 56.4 BF - 0.87 Comparative yearly lighting energy cost per 1000 lumens = $4.07