QVS2GPTOS232
ALTER METALYTE
2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 LAMP, T8, 5 1/2” DEEP MICROPERFORATED MESH LAMP SHIELD STATIC
Efficiency 44.8%. Semi-specular aluminum reflectors with
lengthwise ridges. Swing down microperforated lamp shield
for easy relamping and maintenance. Alter soft white film on inside of mesh conceals
lamp image and provide balance between reflected light and direct light.
Fully recessed luminaire and lamp compartment.
Specular interior reflector. One piece body for easy installation. Easy access to ballast through lamp
compartment. Fits standard T-Grid ceilings. Optional acrylic drop-down visual element.
MOUNTING METHODS/FEATURES DIMENSIONS
Ceiling compatibility
Suited to standard exposed T-grid ceilings
Swing down optical system for easy relamping and maintenance
Microperforated mesh lamp shields
Suited to standard exposed Slot T-grid ceilings
FIXTURE TYPE
Semi-specular aluminum reflector with lengthwise ridges
Genlyte Thomas Company
VOLTS
L30-50
JOB INFORMATION:
QVS2GPTOS232
Genlyte Thomas Company
ALTER METALYTE
2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT
ORDERING INFORMATION Explanation of Catalogue Number Example: QVS2GPTOS232120SO
QVS
QUALITY
VISUAL
STATIC Recessed direct indirect soft light optical system
SPECIFICATIONS
MATERIALS: One piece chassis constructed from die formed
20 gauge cold rolled steel. Reflectors - Semi-specular matte aluminum reflector with lenghtwise ridges. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte high reflectance paint finish.
2
FIXTURE
WIDTH
2’
G
CEILING
TYPE
Standard exposed T-grid ceilings
PT
LAMP
SHIELD
PT=Semi-
specular matte
reflector /
Microperforated
mesh
lamp shield
OS 2 32
CLEAR POLISHED
ACRYLIC DROP
DOWN VISUAL ELEMENT OS =Open slot (no acrylic)
OP =One Piece (no center slot) GC =Clear acrylic GG =Clear acrylic / Green projected color face GB =Clear acrylic / Blue projected color face GR = Clear acrylic / Red projected color face
LAMP
QUANTITY
ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL
LAMP/FIXTURE
LENGTH
(NOMINAL 24”) 32 = 32W T8
120
VOLTAGE
120,277
347
BALLAST SO: 2 LPB T8 Elect. PS: T8 PowerSpec HDF Dimming † DA: iGEN DALI †
† Not available in 347V.
SO
OPTIONS
R =Radio Interface Filter O =Emergency Lighting System (for Canada) N =Emergency Lighting System (for U.S.)
We reserve the right to change, materials and finish in any way that will not alter installed appearance or reduce function and performance.